Colorectal hepatic metastases: detection with SPIO-enhanced breath-hold MR imaging--comparison of optimized sequences.

Abstract:

PURPOSE:To compare the accuracy of four breath-hold magnetic resonance (MR) imaging sequences to establish the most effective superparamagnetic iron oxide (SPIO)-enhanced sequence for detection of colorectal hepatic metastases. MATERIALS AND METHODS:Thirty-one patients with colorectal hepatic metastases underwent T1-weighted gradient-echo (GRE) and T2-weighted fast spin-echo (FSE) MR imaging before and after SPIO enhancement. Four sequences were optimized for lesion detection: T2-weighted FSE, multiecho data image combination (MEDIC), T2-weighted GRE with an 11-msec echo time (TE), and T2-weighted GRE with a 15-msec TE. Images were reviewed independently by three blinded observers. The accuracy of each sequence was measured by using alternative free-response receiver operating characteristic analysis. All results were correlated with findings at surgery, intraoperative ultrasonography, or histopathologic examination. Differences between the mean results of the three observers were measured by using the Student t test. RESULTS:Postcontrast T2-weighted GRE sequences were the most accurate and were significantly superior to postcontrast T2-weighted FSE and unenhanced sequences alone (P <.05). For all lesions that were malignant or smaller than 1 cm, respectively, mean accuracies of postcontrast sequences were 0.082 and 0.64 for T2-weighted FSE, 0.90 and 0.78 for MEDIC, 0.92 and 0.80 for GRE with an 11-msec TE, 0.93 and 0.82 for GRE with a 15-msec TE, and 0.81 and 0.62 for unenhanced sequences. CONCLUSION:Optimized SPIO-enhanced T2-weighted GRE combined with unenhanced T2-weighted FSE MR sequences were the most sensitive. Breath-hold FSE postcontrast sequences offer no improvement in sensitivity compared with unenhanced sequences alone.

journal_name

Radiology

journal_title

Radiology

authors

Ward J,Guthrie JA,Wilson D,Arnold P,Lodge JP,Toogood GJ,Wyatt JI,Robinson PJ

doi

10.1148/radiol.2283020376

subject

Has Abstract

pub_date

2003-09-01 00:00:00

pages

709-18

issue

3

eissn

0033-8419

issn

1527-1315

pii

2283020376

journal_volume

228

pub_type

杂志文章
  • Human coronary arteries: projection angiograms reconstructed from breath-hold two-dimensional MR images.

    abstract::The authors sought to render projection magnetic resonance (MR) angiograms depicting a substantial length of human coronary arteries from sequential breath-hold two-dimensional MR images. Tomographic images of the right and left anterior descending coronary arteries were collected with use of a segmented gradient-reca...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.187.3.8497620

    authors: Edelman RR,Manning WJ,Pearlman J,Li W

    更新日期:1993-06-01 00:00:00

  • Measurement of hepatic lipid: high-speed T2-corrected multiecho acquisition at 1H MR spectroscopy--a rapid and accurate technique.

    abstract:PURPOSE:To evaluate the feasibility, accuracy, and reproducibility of a fast breath-hold magnetic resonance (MR) spectroscopic method for T2-corrected hepatic lipid measurement in phantoms and in humans. MATERIALS AND METHODS:All experiments were institutional review board approved and HIPAA compliant; informed consen...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2523082084

    authors: Pineda N,Sharma P,Xu Q,Hu X,Vos M,Martin DR

    更新日期:2009-08-01 00:00:00

  • Scanning slit chest radiography: a practical and efficient scatter control design.

    abstract:PURPOSE:To design a chest radiography unit that eliminates scatter. MATERIALS AND METHODS:A scanning slit radiography unit that also incorporates a conventional grid was designed. The scanning slit geometry defined a 10-mm-wide beam at the image receptor. RESULTS:With a typical heavy-duty radiographic tube, the propo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.2.8284410

    authors: Barnes GT,Wu X,Sanders PC

    更新日期:1994-02-01 00:00:00

  • Association of Preoperative US Features and Recurrence in Patients with Classic Papillary Thyroid Carcinoma.

    abstract:PURPOSE:To investigate whether ultrasonographic (US) features of thyroid nodules are associated with tumor recurrence in classic papillary thyroid carcinoma (PTC). MATERIALS AND METHODS:This retrospective study was approved by the Institutional Review Board, and the need to obtain informed consent was waived. A total ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142470

    authors: Kim SY,Kwak JY,Kim EK,Yoon JH,Moon HJ

    更新日期:2015-11-01 00:00:00

  • Primary non-small cell lung cancer: review of frequency, location, and time of recurrence after radiofrequency ablation.

    abstract:PURPOSE:To review the recurrence patterns in patients with primary non-small cell lung cancer (NSCLC) treated with percutaneous image-guided radiofrequency (RF) ablation. MATERIALS AND METHODS:This retrospective review was institutional review board approved and HIPAA compliant. Informed consent was waived. Data from ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.00000090174

    authors: Beland MD,Wasser EJ,Mayo-Smith WW,Dupuy DE

    更新日期:2010-01-01 00:00:00

  • Distribution of various labeled thioglucoses in rodents.

    abstract::Gold, silver and lead thioglucose were evaluated in rodents to determine the value of organo-metallic compounds in the study of metabolic abnormalities. Increased radioactivity concentration was noted in the hypothalamus with all compounds. Gold thioglucose concentrated in the kidneys and thymus, and 203Pb-thioglucose...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/15.3.723

    authors: Atkins HL,Lambrecht RM,Wolf AP,Ansari AN,Guillaume M

    更新日期:1975-06-01 00:00:00

  • Case 256: Breast Implant-associated Anaplastic Large-Cell Lymphoma.

    abstract::History A 57-year-old woman presented with right breast swelling and enlargement and a palpable mass in the right lower inner breast. There was no history of fever, trauma, skin redness, or nipple discharge. The patient had a history of breast augmentation, with retropectoral silicone implants placed 2.5 years ago. Sc...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018160440

    authors: Eisenberg AM,Eppelheimer CN,Fulop TA,Abramson LL

    更新日期:2018-08-01 00:00:00

  • Percutaneous adrenal biopsy: review of a 10-year experience.

    abstract:PURPOSE:To evaluate the indications for and complications, accuracy, and techniques of percutaneous adrenal biopsy performed from 1982 through 1991 at the authors' institution. MATERIALS AND METHODS:Two hundred seventy-seven percutaneous adrenal biopsies were performed in 270 patients (175 male and 102 female patients...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.193.2.7972740

    authors: Welch TJ,Sheedy PF 2nd,Stephens DH,Johnson CM,Swensen SJ

    更新日期:1994-11-01 00:00:00

  • Comparison of resting intracoronary particulate imaging and stress thallium-201 studies.

    abstract::Stress thallium-201 and resting dual intracoronary particulate imaging were evaluated in 120 patients who underwent coronary angiography. Forty of 42 patients without significant coronary disease had normal stress images and 41 had normal rest studies. Eighty-three stress perfusion defects were identified in 61 of 78 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.7367640

    authors: Kolibash AJ,Call TD,Tetalman MR,Bush CA,Scheu J

    更新日期:1980-05-01 00:00:00

  • Sigmoid diverticulitis: diagnostic role of CT--comparison with barium enema studies.

    abstract::The diagnostic value of computed tomography (CT) and barium enema (BE) studies was evaluated prospectively in hospitalized patients with the presumptive diagnosis of acute sigmoid diverticulitis based on the presence of left-lower-quadrant pain and tenderness, fever, and leukocytosis. Of 56 patients, 11 had sigmoid di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2191360

    authors: Cho KC,Morehouse HT,Alterman DD,Thornhill BA

    更新日期:1990-07-01 00:00:00

  • Sodium nitroprusside in the treatment of ergotism.

    abstract::Severe peripheral vasoconstriction of the legs due to hypersensitivity to small doses of ergotamine tartrate developed in a patient with migraine headaches. The vasospasm was successfully treated with continuous intra-arterial and intravenous infusion of sodium nitroprusside. The contribution of angiography in the dia...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/124.1.73

    authors: O'Dell CW,Davis GB,Johnson AD,Safdi MA,Brant-Zawadzki M,Bookstein JJ

    更新日期:1977-07-01 00:00:00

  • Desirability of roentgen esophageal examination immediately after pneumatic dilatation for achalasia.

    abstract::Although infrequent, esophageal rupture is a serious complication of pneumatic dilatation for the treatment of achalasia. Because of an experience with delayed recognition of esophageal perforation in a patient with achalasia, we now examine the esophagus using a water-soluble contrast medium immediately following eve...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.3.589

    authors: Stewart ET,Miller WN,Hogan WJ,Dodds WJ

    更新日期:1979-03-01 00:00:00

  • Dynamic contrast-enhanced MR imaging measurement of vertebral bone marrow perfusion may be indicator of outcome of acute myeloid leukemia patients in remission.

    abstract:PURPOSE:To examine whether dynamic contrast material-enhanced (DCE) magnetic resonance (MR) imaging measurement of bone marrow perfusion in acute myeloid leukemia (AML) patients in complete remission (CR) is associated with outcome and survival. MATERIALS AND METHODS:After institutional review board approval and infor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10100995

    authors: Chen BB,Hsu CY,Yu CW,Hou HA,Liu CY,Wei SY,Chou WC,Tien HF,Shih TT

    更新日期:2011-03-01 00:00:00

  • Comparison of the Reliability of Acoustic Radiation Force Impulse Imaging and Supersonic Shear Imaging in Measurement of Liver Stiffness.

    abstract:PURPOSE:To compare the reliability of acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI) in measurement of liver stiffness. MATERIALS AND METHODS:This study was approved by the institutional review board, and written informed consent was obtained for all patients. Seventy-nine patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141975

    authors: Woo H,Lee JY,Yoon JH,Kim W,Cho B,Choi BI

    更新日期:2015-12-01 00:00:00

  • Recommendations for the management of subsolid pulmonary nodules detected at CT: a statement from the Fleischner Society.

    abstract::This report is to complement the original Fleischner Society recommendations for incidentally detected solid nodules by proposing a set of recommendations specifically aimed at subsolid nodules. The development of a standardized approach to the interpretation and management of subsolid nodules remains critically impor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12120628

    authors: Naidich DP,Bankier AA,MacMahon H,Schaefer-Prokop CM,Pistolesi M,Goo JM,Macchiarini P,Crapo JD,Herold CJ,Austin JH,Travis WD

    更新日期:2013-01-01 00:00:00

  • Major geometric variations between multiple high-dose-rate applications of brachytherapy in cancer of the cervix: frequency and types of variation.

    abstract:PURPOSE:To evaluate major geometric variations in multiple intracavitary applications for carcinoma of the cervix. MATERIALS AND METHODS:Orthogonal radiographs were reviewed of 17 consecutive patients with carcinoma of the cervix treated with 70 applications of high-dose-rate brachytherapy. In seven patients, consciou...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.2.7724760

    authors: Kim RY,Meyer JT,Plott WE,Spencer SA,Meredith RF,Jennelle RL,Salter MM

    更新日期:1995-05-01 00:00:00

  • Influence of blood-pool contrast media on MR imaging and flow measurements in the presence of pulmonary arterial stents in swine.

    abstract:PURPOSE:To compare the effects of various stents on magnetic resonance (MR) imaging flow volume measurements and to determine the value of a blood-pool MR imaging contrast medium in assessment of vascular stents. MATERIALS AND METHODS:In 11 pigs, six nitinol stents (Memotherm), four platinum stents (NuMed), and one el...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2232010975

    authors: Kuehne T,Saeed M,Moore P,Gleason K,Reddy G,Teitel D,Higgins CB

    更新日期:2002-05-01 00:00:00

  • Hepatocellular carcinoma with portal vein tumor thrombus: embolization of arterioportal shunts.

    abstract:PURPOSE:To evaluate transcatheter arterial embolization in patients with hepatocellular carcinoma, portal vein tumor thrombus, and arterioportal shunts. MATERIALS AND METHODS:Ten patients with hepatocellular carcinoma, portal vein tumor thrombus, and severe arterioportal shunting were identified; in these patients, po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.3.9280260

    authors: Furuse J,Iwasaki M,Yoshino M,Konishi M,Kawano N,Kinoshita T,Ryu M,Satake M,Moriyama N

    更新日期:1997-09-01 00:00:00

  • Prosthetic testicle: appearance at MR imaging.

    abstract::The appearance of testicular prostheses on magnetic resonance (MR) images was studied in six patients with seven silicone implants: two with a fluid consistency and five that were solid. On T1-weighted images, both types of prosthesis demonstrated homogeneous low signal intensity; on T2-weighted images, the fluid impl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2798890

    authors: Semelka R,Anderson M,Hricak H

    更新日期:1989-11-01 00:00:00

  • Congenital hepatic artery aneurysm simulating pancreatic carcinoma.

    abstract::The authors report a case of a hepatic artery aneurysm that simulated a mass in the head of the pancreas. The correct diagnosis was made preoperatively based on several findings: curvilinear calcification within the mass on CT, a well-defined cystic collection on ultrasound, absence of biliary duct dilatation or jaund...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.3.6463240

    authors: Gavin PM,Matalon TA,Petasnick JP,Roseman DL

    更新日期:1984-09-01 00:00:00

  • Rapid change in caliber of the nonobstructed common duct.

    abstract::A case of a postcholecystectomy patient is presented in which an initially grossly dilated common hepatic duct returned to normal size within several minutes. We have tried to explain this phenomenon using known facts abut bile duct elasticity and bile flow, and conclude that such rapid size change probably only occur...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.1.7244220

    authors: Glazer GM,Filly RA,Laing FC

    更新日期:1981-07-01 00:00:00

  • Artificially induced pneumothorax for percutaneous transthoracic radiofrequency ablation of tumors in the hepatic dome: initial experience.

    abstract::After institutional review board approval, informed consent was obtained from six patients (four men and two women, aged 47-74 years) with a total of six tumors of the liver dome. These patients were treated by means of radiofrequency (RF) ablation with computed tomographic (CT) guidance and a transthoracic approach. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2362040992

    authors: de Baère T,Dromain C,Lapeyre M,Briggs P,Duret JS,Hakime A,Boige V,Ducreux M

    更新日期:2005-08-01 00:00:00

  • Pure ductal carcinoma in situ: kinetic and morphologic MR characteristics compared with mammographic appearance and nuclear grade.

    abstract:PURPOSE:To retrospectively compare the kinetic and morphologic characteristics of pure ductal carcinoma in situ (DCIS) lesions depicted on dynamic contrast material-enhanced magnetic resonance (MR) images with the nuclear grade and conventional mammographic appearance of these lesions. MATERIALS AND METHODS:This HIPAA...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2453062061

    authors: Jansen SA,Newstead GM,Abe H,Shimauchi A,Schmidt RA,Karczmar GS

    更新日期:2007-12-01 00:00:00

  • Changes in primary breast cancer heterogeneity may augment midtreatment MR imaging assessment of response to neoadjuvant chemotherapy.

    abstract:PURPOSE:To evaluate whether changes in magnetic resonance (MR) imaging heterogeneity may aid assessment for pathologic complete response (pCR) to neoadjuvant chemotherapy (NACT) in primary breast cancer and to compare pCR with standard Response Evaluation Criteria in Solid Tumors response. MATERIALS AND METHODS:Instit...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14130569

    authors: Parikh J,Selmi M,Charles-Edwards G,Glendenning J,Ganeshan B,Verma H,Mansi J,Harries M,Tutt A,Goh V

    更新日期:2014-07-01 00:00:00

  • Coronary artery stent patency assessed with in-stent contrast enhancement measured at multi-detector row CT angiography: initial experience.

    abstract::The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent car...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2331031564

    authors: Hong C,Chrysant GS,Woodard PK,Bae KT

    更新日期:2004-10-01 00:00:00

  • Age-related apparent diffusion coefficient changes in the normal brain.

    abstract:PURPOSE:To measure the mean diffusional age-related changes of the brain over the full human life span by using diffusion-weighted spin-echo single-shot echo-planar magnetic resonance (MR) imaging and sequential whole-brain apparent diffusion coefficient (ADC) histogram analysis and, secondarily, to build mathematical ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.12112420

    authors: Watanabe M,Sakai O,Ozonoff A,Kussman S,Jara H

    更新日期:2013-02-01 00:00:00

  • Holoprosencephaly in children: diffusion tensor MR imaging of white matter tracts of the brainstem--initial experience.

    abstract:PURPOSE:To evaluate the dimensions of specific white matter tracts in the brainstems (region of brain thought to be least affected) of children with holoprosencephaly by using diffusion tensor magnetic resonance (MR) imaging and to correlate these abnormalities with forebrain malformation severity and neurologic defici...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2233011197

    authors: Albayram S,Melhem ER,Mori S,Zinreich SJ,Barkovich AJ,Kinsman SL

    更新日期:2002-06-01 00:00:00

  • Internal contamination of laboratory personnel by 131I1.

    abstract::Internal contamination by 131I among the personnel in a nuclear medicine laboratory was surveyed from January to July, 1979. Because of the formulation change made by the manufacturer in April to reduce volatility, it was possible to study two different therapeutic solutions of 131I. Internal contamination of personne...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.137.3.7444060

    authors: Nishiyama H,Lukes SJ,Mayfield G,Grossman LW

    更新日期:1980-12-01 00:00:00

  • Adenomyosis: prospective comparison of MR imaging and transvaginal sonography.

    abstract:PURPOSE:To prospectively compare conventional spin-echo magnetic resonance (MR) imaging and transvaginal sonography for the diagnosis of adenomyosis. MATERIALS AND METHODS:Twenty women with clinically suspected adenomyosis underwent MR imaging and transvaginal sonography performed within 3 months of each other. Pathol...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.190.3.8115630

    authors: Ascher SM,Arnold LL,Patt RH,Schruefer JJ,Bagley AS,Semelka RC,Zeman RK,Simon JA

    更新日期:1994-03-01 00:00:00

  • New tools of the trade.

    abstract::The author reviews the regulatory process through which new cardiovascular interventional devices reach the hands of the interventional radiologist and the cardiologist. The marketing mechanisms are outlined, as are the data requirements. The reader is taken step-by-step from device investigation conducted under an ap...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.174.3.174-3-923

    authors: Reamer LA

    更新日期:1990-03-01 00:00:00