Carotid angioplasty and stent placement: comparison of transcranial Doppler US data and clinical outcome with and without filtering cerebral protection devices in 509 patients.

Abstract:

PURPOSE:To prospectively evaluate emboli detected at transcranial Doppler ultrasonography (US) and outcome of carotid angioplasty and stent placement and compare these findings in patients treated with the use of filtering cerebral protection devices (CPDs) with the findings in patients treated without the use of filtering CPDs. MATERIALS AND METHODS:This study was approved by the institutional human research committee. Written informed consent was obtained for all patients. Patients were divided into three groups: 161 patients treated before filtering CPDs had become available (group 1), 151 patients treated with filtering CPDs (group 2), and 197 patients treated without CPDs after CPDs had become available (group 3). Clinical end points were cerebral ischemic events and death. Transcranial Doppler US end points included isolated microemboli, microembolic showers, macroemboli, and distal thrombus. The procedure was divided into five phases: wiring, predilation, stent deployment, postdilation, and CPD handling. Data not distributed normally were analyzed with the Mann-Whitney U statistic. For binomial data, the chi(2) test was used. P < .05 indicated statistical significance. RESULTS:For each phase, median and interquartile range (IQR) for isolated microemboli in group 2 versus group 3 were as follows: wiring, 51 (IQR, 31-69) versus 27 (IQR, 15-48); predilation, 19 (IQR, 13-33) versus 13 (IQR, 8-19); stent deployment, 64 (IQR, 46-82) versus 48.5 (IQR, 33.25-66); and postdilation, 24 (IQR, 14-39) versus 16 (IQR, 11-27.5) (P < .001 for each phase). Median and IQR for microembolic showers were as follows: wiring, 0 (IQR, 0-3) versus 0 (IQR, 0-0); predilation, 1.5 (IQR, 0-4) versus 0 (IQR, 0-2); stent deployment, 22 (IQR, 11-36) versus 11 (IQR, 6-17); postdilation, three (IQR, 0-9) versus one (IQR, 0-4); (postdilation phase, P = .001; all other phases, P < .001). Median for isolated microemboli in group 1 versus groups 2 and 3 combined were as follows: predilation, 10 (IQR, 5-22.75) versus 16 (IQR, 9-25) (P = .001); stent deployment, 32 (IQR, 15-58) versus 54 (IQR, 40.5-74) (P < .001); and postdilation, 11 (IQR, 6-19) versus 18 (IQR, 12-33) (P < .001). Median for microembolic showers during stent deployment were six (IQR, 1-14) versus 13 (IQR, 7-26) (P < .001). Five patients died, and five major strokes and 14 minor strokes occurred. Eight macroemboli occurred in unprotected procedures; six distal thrombi occurred in protected procedures. CONCLUSION:Carotid angioplasty and stent placement yielded more microemboli in patients treated with filtering CPDs than in unprotected procedures. The infrequent occurrence of cerebral sequelae did not allow comprehensive statistical comparison between groups.

journal_name

Radiology

journal_title

Radiology

authors

Vos JA,van den Berg JC,Ernst SM,Suttorp MJ,Overtoom TT,Mauser HW,Vogels OJ,van Heesewijk HP,Moll FL,van der Graaf Y,Mali WP,Ackerstaff RG

doi

10.1148/radiol.2342040119

subject

Has Abstract

pub_date

2005-02-01 00:00:00

pages

493-9

issue

2

eissn

0033-8419

issn

1527-1315

pii

2342040119

journal_volume

234

pub_type

杂志文章
  • Can sonographers reliably identify anatomic features associated with Down syndrome in fetuses?

    abstract::To standardize femur measurement for the identification of fetuses at risk for Down syndrome, sonographers of varying professional experience and background measured the femurs of 20 Down syndrome fetuses and 709 normal control fetuses. A regression analysis performed to compare biparietal diameter to femur length on ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.173.2.2529580

    authors: Benacerraf BR,Cnann A,Gelman R,Laboda LA,Frigoletto FD Jr

    更新日期:1989-11-01 00:00:00

  • Suspected anastomotic recurrence of Crohn disease after ileocolic resection: evaluation with CT enteroclysis.

    abstract:PURPOSE:To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS:Written informed consent was prospectively obtained from all patients, and the ins...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.09091165

    authors: Soyer P,Boudiaf M,Sirol M,Dray X,Aout M,Duchat F,Vahedi K,Fargeaudou Y,Martin-Grivaud S,Hamzi L,Vicaut E,Rymer R

    更新日期:2010-03-01 00:00:00

  • Colorectal carcinoma metastases: detection with In-111-labeled monoclonal antibody CCR 086.

    abstract::A phase I/II clinical trial with indium-111-labeled antimucin murine monoclonal antibody (MoAb) CCR 086 was conducted. Seventeen patients with histologically proved colorectal carcinoma and known metastatic disease underwent external scintigraphy after administration of 5.5 mCi (203.5 MBq) of In-111 CCR 086 at doses o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2353080

    authors: Abdel-Nabi HH,Levine G,Lamki LM,Murray JL,Tauxe WN,Shah AN,Patt YZ,Doerr RJ,Klein HA,Gona J

    更新日期:1990-07-01 00:00:00

  • Hepatocellular carcinoma: assessment of resectability by computed tomography and ultrasound.

    abstract::A retrospective review of the CT and ultrasound scans from examinations of 30 patients who had hepatocellular carcinoma (hepatoma) was undertaken with special emphasis placed on evaluation of hepatic distribution of tumor, vascular invasion, and extrahepatic spread. Although both CT and ultrasound detected hepatoma in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6330790

    authors: LaBerge JM,Laing FC,Federle MP,Jeffrey RB Jr,Lim RC Jr

    更新日期:1984-08-01 00:00:00

  • Detection of Prostate Cancer: Quantitative Multiparametric MR Imaging Models Developed Using Registered Correlative Histopathology.

    abstract::Purpose To develop multiparametric magnetic resonance (MR) imaging models to generate a quantitative, user-independent, voxel-wise composite biomarker score (CBS) for detection of prostate cancer by using coregistered correlative histopathologic results, and to compare performance of CBS-based detection with that of s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015151089

    authors: Metzger GJ,Kalavagunta C,Spilseth B,Bolan PJ,Li X,Hutter D,Nam JW,Johnson AD,Henriksen JC,Moench L,Konety B,Warlick CA,Schmechel SC,Koopmeiners JS

    更新日期:2016-06-01 00:00:00

  • Dynamic CT angiography after abdominal aortic endovascular aneurysm repair: influence of enhancement patterns and optimal bolus timing on endoleak detection.

    abstract:PURPOSE:To determine the time course of enhancement patterns in the aorta and endoleaks at dynamic computed tomographic (CT) angiography as well as their effect on the endoleak detection rate in patients who have undergone abdominal aortic endovascular aneurysm repair (EVAR). MATERIALS AND METHODS:This retrospective s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13120197

    authors: Lehmkuhl L,Andres C,Lücke C,Hoffmann J,Foldyna B,Grothoff M,Nitzsche S,Schmidt A,Ulrich M,Scheinert D,Gutberlet M

    更新日期:2013-09-01 00:00:00

  • Laser therapy for breast cancer: MR imaging and histopathologic correlation.

    abstract:PURPOSE:To investigate magnetic resonance (MR) imaging guidance of interstitial laser photocoagulation to treat primary breast cancer. MATERIALS AND METHODS:Twenty female patients with symptomatic breast cancers diagnosed at cytologic examination underwent interstitial laser photocoagulation by means of a single fiber...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.200.3.8756910

    authors: Mumtaz H,Hall-Craggs MA,Wotherspoon A,Paley M,Buonaccorsi G,Amin Z,Wilkinson I,Kissin MW,Davidson TI,Taylor I,Bown SG

    更新日期:1996-09-01 00:00:00

  • An analog patient model derived from computed tomograms for three-dimensional radiotherapy planning.

    abstract::An analog model of the part of a patient's body containing a tumor is constructed by drawing anatomical contours obtained from computed tomograms on a set of transparent plastic sheets. The coverage of radiotherapy fields in the patient is visualized in three dimensions using the model and the light beam from the radi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.1.7384510

    authors: Tatcher M,Elgrabli S,Kuten A,Kleinhaus U

    更新日期:1980-07-01 00:00:00

  • Needle localization of occult breast lesions with a curved-end retractable wire: technique and pitfalls.

    abstract::A series of 100 consecutive occult mammographic abnormalities were localized with a curved-end retractable wire system. A true-positive rate of 24% and a failure rate of 4% for initial excision were found. The pitfalls and advantages of this new needle-wire breast localizer are presented. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.2.3763930

    authors: Homer MJ,Pile-Spellman ER

    更新日期:1986-11-01 00:00:00

  • Work in progress: NMR anatomy of the larynx and tongue base.

    abstract::The normal anatomy of the larynx and base of the tongue as seen on nuclear magnetic resonance (NMR) images was studied. Scans of normal volunteers were obtained using a 3.5 kilogauss (0.35 T) superconductive magnet and a 3.0 kilogauss (0.3 T) permanent magnet. The NMR images were compared with images obtained by CT an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.1.6856830

    authors: Lufkin RB,Larsson SG,Hanafee WN

    更新日期:1983-07-01 00:00:00

  • Lung tumors: percutaneous implantation of I-125 sources with CT treatment planning.

    abstract::Seven patients with lung tumors underwent percutaneous implantation of iodine-125 sources into the tumor. Needle placement and seed implantation were effected with biplane fluoroscopy and a computer planning model based on computed tomography. No complications were encountered. Five of the seven patients underwent the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.164.3.3615870

    authors: Heelan RT,Hilaris BS,Anderson LL,Nori D,Martini N,Watson RC,Caravelli JF,Linares LA

    更新日期:1987-09-01 00:00:00

  • US of the snapping iliopsoas tendon.

    abstract:PURPOSE:To determine the value of ultrasound (US) in the diagnosis of snapping iliopsoas tendon. MATERIALS AND METHODS:In three patients, dynamic US of the hip was performed as the flexed, abducted, and externally rotated hip was extended. The contralateral hip was also evaluated. Hip arthrography was performed in all...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.2.8596860

    authors: Cardinal E,Buckwalter KA,Capello WN,Duval N

    更新日期:1996-02-01 00:00:00

  • Is There an Association between STARD Statement Adherence and Citation Rate?

    abstract::Purpose To determine if adherence to the Standards for Reporting of Diagnostic Accuracy (STARD) is associated with postpublication citation rates. Materials and Methods A comprehensive search of PubMed, EMBASE, and Cochrane Library databases was performed to identify published articles that have evaluated adherence of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016151384

    authors: Dilauro M,McInnes MD,Korevaar DA,van der Pol CB,Petrcich W,Walther S,Quon J,Kurowecki D,Bossuyt PM

    更新日期:2016-07-01 00:00:00

  • Fetal cerebral ventriculomegaly: misidentification of the true medial boundary of the ventricle at US.

    abstract:PURPOSE:To investigate the implications of mistaking the medial surface of the cerebral hemisphere for the medial wall of the lateral ventricle at antenatal ultrasonography (US) and to identify US clues that might help avoid this interpretive error. MATERIALS AND METHODS:In 50 second- and third-trimester fetuses, a di...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.205.3.9393540

    authors: Hertzberg BS,Kliewer MA,Bowie JD

    更新日期:1997-12-01 00:00:00

  • Radiotherapy of orbital pseudotumor.

    abstract::Recent advances in ultrasound and computed tomography have permitted localization of orbital lesions, and sophisticated high-energy irradiation techniques facilitate improved dose distribution without significant damage to normal tissue. Three patients treated for orbital pseudotumor are discussed. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/127.2.507

    authors: Kim RY,Roth RE

    更新日期:1978-05-01 00:00:00

  • Gynecomastoid hyperplasia: imaging findings in six patients.

    abstract::This case series describes the radiologic appearances of gynecomastoid hyperplasia of the breast in our experience. The clinical histories, breast images, and histopathologic findings in six women were reviewed. At mammography, there was no abnormality in two women, an enlarging asymmetric density in three women, and ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.214.2.r00fe24553

    authors: Selland DL,Korbin CD,Lester SC,Lerner MH,Gulizia JA,Kaelin CM,Meyer JE

    更新日期:2000-02-01 00:00:00

  • Radiologic findings of hamartomas of the tuber cinereum and hypothalamus.

    abstract::Five cases, four histologically proved, or hamartoma of the tuber cinereum and hypothalamus in children (age range: 2--12 years) are reported. Three cases had pubertas praecox, and in all of these the hamartoma was located in the basal cistern between the chiasm and pons, and had a collar button shape and size typical...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/127.3.697

    authors: Lin SR,Bryson MM,Gobien RP,Fitz CR,Lee YY

    更新日期:1978-06-01 00:00:00

  • Detection and classification of liquid-filled masses in the breast by gray scale echography.

    abstract::Gray scale ultrasonic visualization of the breast is a simple and safe technique for the detection of liquid-filled masses. Cysts and enlarged ducts as small as 2 mm in diameter can be reliably detected with a greater accuracy than is possible with any other imaging technique. The ultrasonic examination provides consi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.1.205

    authors: Jellins J,Kossoff G,Reeve TS

    更新日期:1977-10-01 00:00:00

  • Quantitative and qualitative evaluations of fetal lung with MR imaging.

    abstract:PURPOSE:To measure both volume and signal intensity of the fetal lung at magnetic resonance (MR) imaging and to evaluate the clinical use of this method to predict fetal pulmonary hypoplasia. MATERIALS AND METHODS:A total of 87 fetuses evaluated with MR imaging at 24-39 weeks of gestation were classified into a contro...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2313021689

    authors: Osada H,Kaku K,Masuda K,Iitsuka Y,Seki K,Sekiya S

    更新日期:2004-06-01 00:00:00

  • Gastric retention of zinc-based pennies: radiographic appearance and hazards.

    abstract:PURPOSE:To determine the radiographic appearance and features of corrosion in U.S. coins exposed to gastric acid. MATERIALS AND METHODS:Six U.S. copper-based pre-1982 pennies, 12 zinc-based post-1982 pennies, a quarter, a nickel, and a dime were exposed to postprandial concentrations of gastric acid (0.15N HCl) for 7 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.1.r99oc36113

    authors: O'Hara SM,Donnelly LF,Chuang E,Briner WH,Bisset GS 3rd

    更新日期:1999-10-01 00:00:00

  • Noxious somatosensory stimulation affects the default mode of brain function: evidence from functional MR imaging.

    abstract:PURPOSE:To investigate whether default mode network (DMN) spatial properties can be directly affected by pain, with a comparison of painful and nonpainful conditions. MATERIALS AND METHODS:The authors performed a functional magnetic resonance (MR) imaging study, approved by the local institutional ethics committee, in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2533090602

    authors: Mantini D,Caulo M,Ferretti A,Romani GL,Tartaro A

    更新日期:2009-12-01 00:00:00

  • Pilomatrixoma (calcifying epithelioma of Malherbe): radiographic features.

    abstract::Pilomatrixomas (calcifying epitheliomas of Malherbe) are benign soft-tissue tumors that occur in the dermis or subcutaneous tissues; about 40% are found in children under 10 years of age. More than 80% have microscopic calcification and/or ossification. Although the incidence of radiographically visible calcification ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.151

    authors: Haller JO,Kassner G,Ostrowitz A,Kottmeler K,Perfschuk LP

    更新日期:1977-04-01 00:00:00

  • Retrosomatic clefts: computed tomographic appearance.

    abstract::A case of bilateral clefts in the pedicles of the L1 vertebra, diagnosed by computed tomography, is presented. The differentiation from other clefts located laterally in the neural arch is briefly summarized, and the possible origin of this entity is discussed. It is improbable that the clefts represent persistent neu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6867340

    authors: Johansen JG,McCarty DJ,Haughton VM

    更新日期:1983-08-01 00:00:00

  • Hippocampal dysfunction in Gulf War veterans: investigation with ASL perfusion MR imaging and physostigmine challenge.

    abstract:PURPOSE:To determine, with arterial spin labeling (ASL) perfusion magnetic resonance (MR) imaging and physostigmine challenge, if abnormal hippocampal blood flow in ill Gulf War veterans persists 11 years after initial testing with single photon emission computed tomography and nearly 20 years after the 1991 Gulf War. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11101715

    authors: Li X,Spence JS,Buhner DM,Hart J Jr,Cullum CM,Biggs MM,Hester AL,Odegard TN,Carmack PS,Briggs RW,Haley RW

    更新日期:2011-10-01 00:00:00

  • Pulmonary embolus: detection and follow-up using magnetic resonance.

    abstract::Magnetic resonance imaging (MRI) of an angiographically confirmed pulmonary embolus was performed. The thrombus appeared as an intense intraluminal signal within the left descending pulmonary artery; this signal was absent on repeat examination after clot lysis. Because MR will not image flowing blood, it provides a p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.2.6484180

    authors: Moore EH,Gamsu G,Webb WR,Stulbarg MS

    更新日期:1984-11-01 00:00:00

  • Duodenum and duodenal-jejunal junction in children: position and appearance after liver transplantation.

    abstract:PURPOSE:To correlate upper gastrointestinal study findings of the position of the duodenum and duodenal-jejunal junction in children after liver transplantation with transplant type, age at transplantation, indication for transplantation, and history of surgery or malrotation. MATERIALS AND METHODS:Upper gastrointesti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.1.9530320

    authors: Benya EC,Ben-Ami TE,Whitington PF,Alonso EM,Millis JM,Yousefzadeh DK

    更新日期:1998-04-01 00:00:00

  • The scanning grid: a novel and effective bucky movement.

    abstract::A grid consisting of a focused array of radiopaque strips has been constructed. No interspace material is employed, and, during an exposure, the arrangement moves so that the grid strips remain focused and a uniform film density is obtained. Preliminary measurements and radiographs of patients indicate that such a dev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.3.7384470

    authors: Barnes GT,Moreland RF,Yester MV,Witten DM

    更新日期:1980-06-01 00:00:00

  • Gastrostomy and gastrojejunostomy tube placements: outcomes in children with gastroschisis, omphalocele, and congenital diaphragmatic hernia.

    abstract:PURPOSE:To retrospectively evaluate the technical success, safety, and outcomes of radiologically guided retrograde percutaneous gastrostomy and gastrojejunostomy tube placements in terms of weight gain and growth in children with gastroschisis, omphalocele, and/or congenital diaphragmatic hernia (CDH). MATERIALS AND ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2481061193

    authors: Rosenberg J,Amaral JG,Sklar CM,Connolly BL,Temple MJ,John P,Chait PG

    更新日期:2008-07-01 00:00:00

  • Objective assessment of mammography systems. Part II: Implementation.

    abstract::A quality control program for mammography units was carried out, based on objective tests of image quality and dose. Results are reported for 31 units, including correlation between various parameters. Satisfactory results were obtained in the case of 21 installations; for the other 10, comparison between measured qua...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.1.4001410

    authors: Hessler C,Depeursinge C,Grecescu M,Pochon Y,Raimondi S,Valley JF

    更新日期:1985-07-01 00:00:00

  • Percutaneous liver biopsy and track embolization with steel coils.

    abstract::Eight patients with liver disease and seriously abnormal blood coagulation underwent biopsy of the liver performed through a percutaneously introduced sheath, followed by embolization of the biopsy track with steel coils. In all cases the biopsy procedure produced profuse bleeding through the sheath. However, the blee...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.1.3420270

    authors: Allison DJ,Adam A

    更新日期:1988-10-01 00:00:00