Abstract:
PURPOSE:To quantitatively determine the delivery of systemic liposomal doxorubicin to tumors treated with pulsed high-intensity focused ultrasound and to study the mechanism underlying this delivery in a murine model. MATERIALS AND METHODS:All animal work was performed in compliance with guidelines and approval of institutional animal care committee. C3H mice received subcutaneous injections in the flank of a cell suspension of SCC7, a murine squamous cell carcinoma cell line; mice (n = 32) in drug delivery study received unilateral injections, whereas mice (n = 10) in mechanistic study received bilateral injections. Tumors were treated when they reached 1 cm(3) in volume. In the drug delivery study, doxorubicin hydrochloride liposomes were injected into the tail vein: Mice received therapy with doxorubicin injections and high-intensity focused ultrasound, doxorubicin injections alone, or neither form of therapy (controls). Tumors were removed, and the doxorubicin content was assayed with fluorescent spectrophotometry. In the mechanistic study, all mice received an injection of 500-kDa dextran-fluorescein isothyocyanate into the tail vein, and half of them were exposed to high-intensity focused ultrasound prior to injection. Contralateral tumors served as controls for each group. Extravasation of dextran-fluorescein isothyocyanate was observed by using in vivo confocal microscopy. RESULTS:Mean doxorubicin concentration in tumors treated with pulsed high-intensity focused ultrasound was 9.4 microg . g(-1) +/- 2.1 (standard deviation), and it was significantly higher (124% [9.4 microg . g(-1)/4.2 microg . g(-1)]) than in those that were not treated with high-intensity focused ultrasound (4.2 microg . g(-1) +/- 0.95) (P < .001, unpaired two-tailed Student t test). Extravasation of dextran-fluorescein isothyocyanate was observed in the vasculature of tumors treated with high-intensity focused ultrasound but not in that of untreated tumors. CONCLUSION:Pulsed high-intensity focused ultrasound is an effective method of targeting systemic drug delivery to tumor tissue. Potential mechanisms for producing the observed enhancement are discussed.
journal_name
Radiologyjournal_title
Radiologyauthors
Yuh EL,Shulman SG,Mehta SA,Xie J,Chen L,Frenkel V,Bednarski MD,Li KCdoi
10.1148/radiol.2342030889subject
Has Abstractpub_date
2005-02-01 00:00:00pages
431-7issue
2eissn
0033-8419issn
1527-1315pii
234/2/431journal_volume
234pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::A new catheter system was designed for percutaneous fragmentation of large pulmonary emboli. The device consists of an impeller rotating at high speed at the center of a self-expandable basket at the tip of a 7-F catheter. The highly flexible catheter was able to reach all tested embolus sites in a glass model of the ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.180.1.2052680
更新日期:1991-07-01 00:00:00
abstract:PURPOSE:To compare contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography and multi-detector row computed tomographic (CT) angiography in the same patients for assessment of the aortoiliac and renal arteries, with digital subtraction angiography (DSA) as the standard of reference. MATERI...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2271020014
更新日期:2003-03-01 00:00:00
abstract::The effect of transient renal ischemia on renal concentration and distribution of 99mTc-HEDP, 99mTc-DMSA, and 99mTc-DTPA was compared in rabbits with acute tubular necrosis. Scintigrams were obtained after injection in normal rabbits or ones with unilateral or bilateral ischemia. 99mTc-HEDP concentration in ischemic t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.491
更新日期:1979-05-01 00:00:00
abstract::Perfusion computed tomography (CT) is a relatively new technique that allows rapid qualitative and quantitative evaluation of cerebral perfusion by generating maps of cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT). The technique is based on the central volume principle (CBF = CBV/M...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2313021488
更新日期:2004-06-01 00:00:00
abstract::Fine needle, percutaneous aspiration of suspect lymph nodes was carried out in 29 patients during fluoroscopy. The correct positioning of the needle was assured if the node moved with the tip of the needle. In 29 patients, there were 65 successful aspirations and 29 failures. Anesthesia is recommended but care should ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.1.205
更新日期:1976-07-01 00:00:00
abstract:PURPOSE:To retrospectively determine the long-term outcome (>6 months) of placement of tunneled hemodialysis catheters. MATERIALS AND METHODS:The HIPAA-compliant study protocol was approved by the Committee on Human Research, which waived the requirement for informed consent. The records of patients who underwent hemo...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2411050349
更新日期:2006-10-01 00:00:00
abstract:PURPOSE:To assess combined static-dynamic magnetic resonance (MR) urography in the evaluation of congenital urinary tract dilatation in infants and children. MATERIALS AND METHODS:Sixty-two patients with urinary tract dilatation underwent prospective examination with combined static-dynamic MR urography. A combination...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2243011207
更新日期:2002-09-01 00:00:00
abstract::The CT scans of 18 patients with documented pulmonary septic emboli were reviewed. CT features of septic emboli included multiple peripheral nodules ranging in size from 0.5 to 3.5 cm (15 of 18 patients [83%]), a feeding vessel sign (n = 12; [67%]), cavitation (n = 9; [50%]), wedge-shaped peripheral lesions abutting t...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.174.1.2294550
更新日期:1990-01-01 00:00:00
abstract::Radiological abnormalities of the ribs are reported in 5 newborn infants with myotonic dystrophy. In all 5, the ribs appeared very thin, in contrast to the normal appearance of the rest of the skeleton. This slenderness, which is important for diagnosis and prognosis, seems to be caused by hypotonia of the intercostal...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.3.747
更新日期:1978-06-01 00:00:00
abstract::A patent umbilical vein is a sonographic sign of portal hypertension. The specificity of the sign is not known. In a review of 12 patients with sonographically demonstrated patency of the umbilical vein, we found two patients in whom no clinical evidence existed to suggest the presence of portal hypertension. In six o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.145.2.7134450
更新日期:1982-11-01 00:00:00
abstract:PURPOSE:To compare the antiquated x-ray system of Hoffmans and van Kleef (circa 1896) with modern x-ray equipment in terms of radiation dose, x-ray beam properties, image quality, and electrical parameters. MATERIALS AND METHODS:The antiquated x-ray system consisted of a Ruhmkorff inductor, battery, and Crookes tube. ...
journal_title:Radiology
pub_type: 历史文章,杂志文章
doi:10.1148/radiol.11101899
更新日期:2011-05-01 00:00:00
abstract:PURPOSE:To evaluate retrospectively the presence of complete relaxation of the lower esophageal sphincter (LES) at manometry in patients with achalasia depicted on barium esophagograms. MATERIALS AND METHODS:The institutional review board approved this retrospective study and did not require informed consent. A search...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2353040732
更新日期:2005-06-01 00:00:00
abstract::The purpose of this study was to prospectively use a whole-heart three-dimensional (3D) coronary magnetic resonance (MR) angiography technique specifically adapted for use at 3 T and a parallel imaging technique (sensitivity encoding) to evaluate coronary arterial anomalies and variants (CAAV). This HIPAA-compliant st...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2471070274
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:To compare the postdural puncture headache (PDPH) rates after myelography with use of 22-gauge Whitacre (blunt tip) versus standard 22-gauge Quincke (bevel-tip) spinal needles. MATERIALS AND METHODS:At myelography, 340 patients were randomly assigned to one of two groups in which either the Whitacre (167 patie...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.200.3.8756930
更新日期:1996-09-01 00:00:00
abstract::Alterations in gastric physiology caused by selective embolization and vasopressin infusion of the left gastric artery were evaluated in 29 dogs. Gastric acidity was not significantly altered following Gelfoam embolization but decreased sharply with vasopressin infusion. These results suggest that the segmental occlus...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.3.533
更新日期:1976-09-01 00:00:00
abstract::The American College of Radiology (ACR) convened a "think tank" of experts on aspects of molecular imaging. The purposes of the colloquium were to develop scenarios about how molecular imaging would develop in the future and to make recommendations to the ACR about how to prepare radiologists for this important set of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2222011530
更新日期:2002-01-01 00:00:00
abstract:PURPOSE:To determine the accuracy of helical computed tomography (CT) without the oral, intravenous, or rectal administration of contrast material in confirming suspected acute appendicitis. MATERIALS AND METHODS:Three hundred consecutive patients referred from the departments of surgery and emergency medicine were ex...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiology.213.2.r99nv44341
更新日期:1999-11-01 00:00:00
abstract::An adaptation of the Papillon technique was developed in which a superficial x-ray machine was used for treatment of small superficially invasive rectal carcinomas. Modification of the proctoscope-treatment cone apparatus, including addition of a fiberoptic scope, allows confirmation of accurate cone placement through...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.2.3393680
更新日期:1988-08-01 00:00:00
abstract::Radiographic analysis of 33 cases of trisomy 9p (21 familial, 12 nonfamilial) disclosed consistent abnormalities in the hands, feet, and pelvic bones, with one exception (subsequently considered a misdiagnosis). Most of the abnormalities were present only during the period of epiphyseal growth and occurred with simila...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/130.1.125
更新日期:1979-01-01 00:00:00
abstract::Radiographs and CT images taken during oral cholecystography in dogs were interpreted in an independent, blind fashion by three radiologists on two occasions and visual assessment of gallbladder density compared to the actual CT values. While there was significant intra- and inter-observer variation, the mean scores f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.2.7089280
更新日期:1982-07-01 00:00:00
abstract::Purpose To develop and validate a deep learning algorithm that predicts the final diagnosis of Alzheimer disease (AD), mild cognitive impairment, or neither at fluorine 18 (18F) fluorodeoxyglucose (FDG) PET of the brain and compare its performance to that of radiologic readers. Materials and Methods Prospective 18F-FD...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180958
更新日期:2019-02-01 00:00:00
abstract::The purpose of the study was to prospectively evaluate a whole-body magnetic resonance (MR) imaging protocol to help depict metastases by using unenhanced T2-weighted and contrast material-enhanced T1-weighted real-time sequences during continuous table movement. The study was conducted after approval of the local ins...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2463062017
更新日期:2008-03-01 00:00:00
abstract:PURPOSE:To retrospectively assess virtual autopsy performed with multidetector computed tomography (CT) for the forensic evaluation of gunshot wound victims. MATERIALS AND METHODS:The institutional review board approved this HIPAA-compliant study and did not require informed consent of the next of kin. Thirteen consec...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2402050972
更新日期:2006-08-01 00:00:00
abstract::Endoleaks were detected with helical computed tomographic (CT) angiography in five patients after placement of an aortobiliac stent-graft. The leaks were subsequently evaluated with duplex ultrasonography (US) and, in four patients, with conventional aortography as well. CT angiography revealed a total of seven endole...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2253011806
更新日期:2002-12-01 00:00:00
abstract::Background During the peak of the coronavirus disease 2019 (COVID-19) pandemic, the authors noted an increase in positive lower-extremity CT angiography examinations in patients who presented with leg ischemia. The goal of this study was to determine whether lower-extremity arterial thrombosis was associated with COVI...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020202348
更新日期:2020-11-01 00:00:00
abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2018180924
更新日期:2018-12-01 00:00:00
abstract::Diagnostic quality of radiographs and adverse reactions associated with the use of metrizamide and iohexol as contrast agents in lumbar myelography were compared in a prospective randomized double blind study in 350 patients at seven centers. The contrast media were administered in comparable volumes at a concentratio...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.151.3.6371890
更新日期:1984-06-01 00:00:00
abstract::Lumbar spinal fusion is a commonly performed procedure, and, despite changes in cage types and fixation hardware, radiologists have, over the years, become familiar with the imaging features of typical spinal fusion and many of the complications seen in patients after surgery, including pseudoarthrosis, hardware loose...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.11101104
更新日期:2011-08-01 00:00:00
abstract::Tumors of the skull base frequently have some blood supply from cavernous branches of the internal carotid artery (ICA). Preoperative embolization of such pedicles can expedite the subsequently performed surgery. Sometimes, however, the tumor vessels are multiple and very small so selective catheterizations are not po...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.3.1947090
更新日期:1991-12-01 00:00:00
abstract::A systems approach was employed to improve results of the single-contrast barium enema examination for detection of colonic polyps. Improvements were made in each of the following areas: radiographic-fluoroscopic equipment, fluoroscopic-television images, screen-film combinations, barium suspensions, examination techn...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.164.2.3602370
更新日期:1987-08-01 00:00:00