Interference of imferon in colorimetric assays for iron.

Abstract:

:Imferon (Merrell-National), an iron-dextran complex, is widely used in patients with iron deficiency. It is present in the circulation in appreciable amounts for two to three weeks after administration and interferes with all tested colorimetric iron assays, both with and without deproteinization. The amount of the plasma Imferon iron interference depends primarily on the choice of reductant. With dithionite it is essentially 100%. In the presence of ascorbic acid and hydroxylamine, the interference depends also on assay conditions, especially temperature, but also incubation time and pH. The minimum interference in a homogeneous assay was about 3%. The relative amount of interference from hemoglobin iron under the various assay conditions is different from that of Imferon iron. In the presence of a reducing agent, the dextran-iron complex decomposes--instantaneously with dithionite, and gradually with sulfite, ascorbic acid, and hydroxylamine. The freed iron becomes dialyzable, can react with bathophenanthroline, and elutes on a Sephadex G-50 or G-15 column in the same fractions as an ammonium ferrous sulfate.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Huisman W

subject

Has Abstract

pub_date

1980-04-01 00:00:00

pages

635-7

issue

5

eissn

0009-9147

issn

1530-8561

journal_volume

26

pub_type

杂志文章
  • Seasonal and biological variation of blood concentrations of total cholesterol, dehydroepiandrosterone sulfate, hemoglobin A(1c), IgA, prolactin, and free testosterone in healthy women.

    abstract:BACKGROUND:Concentrations of physiological response variables fluctuate over time. The present study describes within-day and seasonal fluctuations for total cholesterol, dehydroepiandrosterone sulfate (DHEA-S), hemoglobin A(1c) (HbA(1c)), IgA, prolactin, and free testosterone in blood, and estimates within- (CV(i)) an...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Garde AH,Hansen AM,Skovgaard LT,Christensen JM

    更新日期:2000-04-01 00:00:00

  • Review of actual proficiency-testing performance under CLIA '67 (March 14, 1990) rules: perspective from the first year's data.

    abstract::Under the Clinical Laboratory Improvement Act of 1967 the Health Care Financing Administration's proficiency-testing requirement applies to approximately 12,000 hospital, reference, and large-clinic laboratories in the United States. The Wisconsin State Laboratory of Hygiene is approved by the Health Care Financing Ad...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lanphear BJ,Burmeister BJ,Ehrmeyer SS,Laessig RH,Hassemer DJ

    更新日期:1992-07-01 00:00:00

  • Osteocalcin concentrations in plasma prepared with different anticoagulants.

    abstract::We investigated the effects on plasma osteocalcin concentrations of different anticoagulants used to collect the blood samples. Plasma osteocalcin concentrations measured by enzyme immunoassay and radioimmunoassay are influenced by the nature of the anticoagulants used. The most significant difference between concentr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Power MJ,O'Dwyer B,Breen E,Fottrell PF

    更新日期:1991-02-01 00:00:00

  • Design and preliminary performance characteristics of a newly proposed reference cell for ionized calcium in serum.

    abstract::A novel flow-through design for a calcium ion-selective liquid membrane and half-cell is proposed. The membrane is based on a neutral carrier for calcium and has the same quantitative chemical composition as that used in most commercial analyzers for ionized calcium (iCa2+). The membrane and half-cell follow the speci...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: D'Orazio P,Bowers GN Jr

    更新日期:1992-07-01 00:00:00

  • Evaluation of "HemoCue," a new device for determining hemoglobin.

    abstract::Hemoglobinometry according to the International Committee of Standardization in Hematology (ICSH) suffers from imprecision related to high sample dilution and from potential errors owing to sample turbidity. We have evaluated a new instrument, "HemoCue," that measures hemoglobin at two wavelengths as azide methemoglob...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: von Schenck H,Falkensson M,Lundberg B

    更新日期:1986-03-01 00:00:00

  • Clinical evaluation of a lead mobilization test using the chelating agent dimercaptosuccinic acid.

    abstract:BACKGROUND:The lead mobilization test reflects the mobilizable and likely toxicologically active fraction of the lead body burden. We propose a safe and convenient protocol for this test, to assess concomitant copper and zinc excretion and to determine the size of the chelatable lead pool in nonoccupationally exposed a...

    journal_title:Clinical chemistry

    pub_type: 临床试验,杂志文章

    doi:10.1373/clinchem.2005.051128

    authors: Hoet P,Buchet JP,Decerf L,Lavalleye B,Haufroid V,Lison D

    更新日期:2006-01-01 00:00:00

  • Screening of drugs and toxic compounds with liquid chromatography-linear ion trap tandem mass spectrometry.

    abstract:BACKGROUND:In clinical and forensic toxicology, general unknown screening is used to detect and identify exogenous compounds. In this study, we aimed to develop a comprehensive general unknown screening method based on liquid chromatography coupled with a hybrid triple-quadrupole linear ion trap mass spectrometer. MET...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2006.067116

    authors: Sauvage FL,Saint-Marcoux F,Duretz B,Deporte D,Lachatre G,Marquet P

    更新日期:2006-09-01 00:00:00

  • High-pressure liquid-chromatographic separation of lactate dehydrogenase isoenzymes.

    abstract::The isoenzymes of lactate dehydrogenase (EC 1.1.1.27) were separated with excellent resolution in less than 1 h by high-pressure anion-exchange chromatography. These isoenzymes were determined in some tissue extracts and high-activity serum samples by this technique. ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kudirka PJ,Schroeder RR,Hewitt TE,Toren EC Jr

    更新日期:1976-04-01 00:00:00

  • Citramalic acid in cerebrospinal fluid of patients with bacterial meningitis.

    abstract::Cerebrospinal fluid (CSF) from uninfected patients and from patients with bacterial and viral meningitis was analyzed by gas-liquid chromatography, with use of a flame ionization detector, and by gas chromatography-mass spectrometry. The resulting profiles were consistent and reproducible. Hydroxy acids were the compo...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Perlman S,Carr SA

    更新日期:1984-07-01 00:00:00

  • Hemoglobin Görwihl [alpha2beta(2)5(A2)Pro-->Ala], an electrophoretically silent variant with impaired glycation.

    abstract:BACKGROUND:Some of the genetic variants of hemoglobin (Hb) and their chemically modified species are known to affect the measurement of Hb A(1c). The purpose of this study was to characterize Hb species in the blood sample of a 74-year-old German male with an exceptionally low Hb A(1c) value. METHODS:Hemolysates from ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/49.1.137

    authors: Bissé E,Schauber C,Zorn N,Epting T,Eigel A,Van Dorsselaer A,Wieland H,Kister J,Kiger L

    更新日期:2003-01-01 00:00:00

  • Comparison of cystatin C and creatinine as predictors of cardiovascular events in a community-based elderly population.

    abstract:BACKGROUND:Reduced renal function is an established risk factor for cardiovascular events. We compared 3 measures of renal function--serum cystatin C, serum creatinine, and calculated creatinine clearance--as predictors of subsequent cardiovascular events in a community-based population of elderly individuals. METHODS...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2009.135962

    authors: Beilby J,Divitini ML,Knuiman MW,Rossi E,Hung J

    更新日期:2010-05-01 00:00:00

  • Microplate measurement of urinary albumin and creatinine.

    abstract::We describe microplate methods for measurement of human urinary albumin (HUA) by competitive enzyme-linked immunosorbant assay (ELISA) and creatinine with a modified commercial enzymatic kit. Incorporation of substrate mixing into the competitive ELISA changes the dynamic absorbance-concentration response, greatly sim...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Magnotti RA Jr,Stephens GW,Rogers RK,Pesce AJ

    更新日期:1989-07-01 00:00:00

  • The National Glycohemoglobin Standardization Program: Over 20 Years of Improving Hemoglobin A1c Measurement.

    abstract:BACKGROUND:Measurement of hemoglobin A1c (HbA1c) in the blood is integral to and essential for the treatment of patients with diabetes mellitus. HbA1c reflects the mean blood glucose concentration over the preceding 8 to 12 weeks. Although the clinical value of HbA1c was initially limited by large differences in result...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2018.296962

    authors: Little RR,Rohlfing C,Sacks DB

    更新日期:2019-07-01 00:00:00

  • Enzyme immunoassay for human apolipoprotein B, the major protein moiety in low-density- and very-low-density lipoproteins.

    abstract::We used enzyme immunoassay to measure apolipoprotein B concentration in human plasma. Pure lipoprotein B was isolated from serum samples of fasting normolipidemic subjects by sequential preparative ultracentrifugation and coated to a polystyrene tube surface by adsorption. Human serum samples and rabbit antiserum to h...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fruchart JC,Desreumaux C,Dewailly P,Sezille G,Jaillard J,Carlier Y,Bout D,Capron A

    更新日期:1978-03-01 00:00:00

  • Clinical performance of an in-line, ex vivo point-of-care monitor: a multicenter study.

    abstract:BACKGROUND:The management of critically ill infants and neonates includes frequent determination of arterial blood gas, electrolyte, and hematocrit values. An objective of attached point-of-care patient monitoring is to provide clinically relevant data without the adverse consequences associated with serial phlebotomy....

    journal_title:Clinical chemistry

    pub_type: 杂志文章,多中心研究

    doi:

    authors: Billman GF,Hughes AB,Dudell GG,Waldman E,Adcock LM,Hall DM,Orsini EN Jr,Koska AJ,Van Marter LJ,Finer NN,Kulhavy JC,Feld RD,Widness JA

    更新日期:2002-11-01 00:00:00

  • Determination of tamoxifen and four metabolites in serum by low-dispersion liquid chromatography.

    abstract::In this assay of tamoxifen and four metabolites in human serum, the serum samples are deproteinized with an equal volume of acetonitrile, then injected into a small (0.21 X 2 cm) precolumn packed with 5-micron-diameter octadecylsilane (ODS) particles. The samples are concentrated on-column by equilibrating the column ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lien EA,Ueland PM,Solheim E,Kvinnsland S

    更新日期:1987-09-01 00:00:00

  • Multiplex SNaPshot genotyping for detecting loss of heterozygosity in the mismatch-repair genes MLH1 and MSH2 in microsatellite-unstable tumors.

    abstract:BACKGROUND:In the workup of patients with suspected hereditary nonpolyposis colorectal cancer (HNPCC), detection of loss of heterozygosity (LOH) could help pinpoint the mismatch-repair (MMR) gene carrying the germline mutation, but analysis of microsatellite markers has proved unreliable for this purpose. We developed ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.108902

    authors: Bujalkova M,Zavodna K,Krivulcik T,Ilencikova D,Wolf B,Kovac M,Karner-Hanusch J,Heinimann K,Marra G,Jiricny J,Bartosova Z

    更新日期:2008-11-01 00:00:00

  • Choriogonadotropin measured with the Tandem-E immunoenzymetric assay system.

    abstract::We evaluated the Hybritech Tandem-E procedure for quantifying choriogonadotropin (hCG) in human serum. In this "sandwich"-type assay, two monoclonal antibodies directed against different regions of the hCG molecule are used, one coated on a plastic bead, the second conjugated to alkaline phosphatase. The assay can det...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bock JL,Furgiuele J,Segen JC

    更新日期:1985-03-01 00:00:00

  • Comparison between High-Sensitivity Cardiac Troponin T and Cardiac Troponin I in a Large General Population Cohort.

    abstract:BACKGROUND:Few data compare cardiac troponin T (cTnT) and cardiac troponin I (cTnI) in a general population. We sought to evaluate the distribution and association between cTnT, cTnI, and cardiovascular risk factors in a large general population cohort. METHODS:High-sensitivity cTnT and cTnI were measured in serum fro...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2018.292086

    authors: Welsh P,Preiss D,Shah ASV,McAllister D,Briggs A,Boachie C,McConnachie A,Hayward C,Padmanabhan S,Welsh C,Woodward M,Campbell A,Porteous D,Mills NL,Sattar N

    更新日期:2018-11-01 00:00:00

  • Performance characteristics of a novel tandem mass spectrometry assay for serum testosterone.

    abstract:BACKGROUND:Commercial immunoassays for testosterone (Te) may give inaccurate results for samples from women and children, leading to misdiagnosis and inappropriate treatment. We developed a sensitive and specific tandem mass spectrometric assay for measurement of Te at the concentrations encountered in women and childr...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.052167

    authors: Kushnir MM,Rockwood AL,Roberts WL,Pattison EG,Bunker AM,Fitzgerald RL,Meikle AW

    更新日期:2006-01-01 00:00:00

  • Development and evaluation of a urine protein expert system.

    abstract::Based on the quantitative determination of creatinine, total protein, albumin, alpha 1-microglobulin, IgG, alpha 2-macroglobulin, and N-acetyl-beta, D-glucosaminidase in urine in combination with a test strip screening, the findings of hematuria, leukocyturia, and proteinuria can be assigned to prerenal, renal, or pos...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Ivandić M,Hofmann W,Guder WG

    更新日期:1996-08-01 00:00:00

  • Multilayer film analysis for glucose in 1-microL samples of plasma.

    abstract::With the ultramicroanalytical system described here we can measure glucose in 1 microL of plasma or serum. The sample is placed on a dry, multilayer film element (Eastman Kodak), where a colored spot about 3.5 mm in diameter develops. The reflectance of these spots is measured with a reflectance digital matrix photome...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Neeley WE,Zettner A

    更新日期:1983-12-01 00:00:00

  • Clinical and laboratory studies of a new immunoradiometric assay of parathyroid hormone-related protein.

    abstract::Parathyroid hormone-related protein (PTHrP) was measured in plasma by a new immunoradiometric assay (IRMA) from Nichols Institute. The assay is specific for PTHrP and shows excellent parallelism when measuring keratinocyte fluid, samples with high PTHrP content, and PTHrP-supplemented plasma. A precision profile estab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Fraser WD,Robinson J,Lawton R,Durham B,Gallacher SJ,Boyle IT,Beastall GH,Logue FC

    更新日期:1993-03-01 00:00:00

  • Enzyme immunoassays with the miniature centrifugal fast analyzer.

    abstract::We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single c...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Lasky FD,Ahuja KK,Karmen A

    更新日期:1977-08-01 00:00:00

  • Alanine aminopeptidase in serum: automated optimized assay, and effects of age, sex, smoking, and alcohol consumption in a selected population.

    abstract::In the diagnosis of chronic (as opposed to acute) liver diseases, combinations of indicators are needed to improve specificity. Alanine aminopeptidase (AAP; microsomal aminopeptidase, EC 3.4.11.2) activity in serum reportedly is a very sensitive indicator of intrahepatic cholestasis and biliary obstruction; it is also...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Mueller PW,Phillips DL,Steinberg KK

    更新日期:1987-03-01 00:00:00

  • Detection of the factor V Leiden mutation by a modified photo-cross-linking oligonucleotide hybridization assay.

    abstract:BACKGROUND:Our previously developed assay for detection of the factor V Leiden mutation (G1691A) based on a nucleic acid photo-cross-linking technology used two allele-specific capture probes and six fluorescein-modified signal-generating reporter probes. We wished to improve the sensitivity and performance of the meth...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2003.023556

    authors: French C,Li C,Strom C,Sun W,Van Atta R,Gonzalez B,Wood M

    更新日期:2004-02-01 00:00:00

  • Two automated methods for plasma antithrombin III compared, and the clinical significance of the results.

    abstract::Antithrombin III (AT III) activity was determined with two different new chromogenic substances--Chromozym-TH (Tos-Gly-Arg-p-nitroanilide; Boehringer Mannheim) and alpha-N-carbobenzyl-oxy-L-lysine-thiobenzyl ester (Du Pont)--with both a discrete (aca) and a centrifugal analyzer (COBAS BIO). The correlation between the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Prellwitz W,Schmitt KF,Machner M,Schuster CJ,Weilemann L

    更新日期:1982-11-01 00:00:00

  • Use of immunoglobulin heavy- and light-chain measurements compared with existing techniques as a means of typing monoclonal immunoglobulins.

    abstract::Using automated measurements of kappa and lambda light chains and IgG, IgA, and IgM, we assessed the utility of the kappa/lambda ratio and the heavy chain/light chain ratio in characterizing monoclonal immunoglobulins previously identified by sensitive electrophoresis on agarose gel and typed by immunofixation or immu...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Whicher JT,Wallage M,Fifield R

    更新日期:1987-10-01 00:00:00

  • Quantification of tau in cerebrospinal fluid by immunoaffinity enrichment and tandem mass spectrometry.

    abstract:BACKGROUND:Cerebrospinal fluid (CSF) tau is a common biomarker for Alzheimer disease (AD). Measurements of tau have historically been performed using immunoassays. Given the molecular diversity of tau in CSF, the selectivity of these immunoassays has often been questioned. Therefore, we aimed to develop an analytically...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2013.216515

    authors: McAvoy T,Lassman ME,Spellman DS,Ke Z,Howell BJ,Wong O,Zhu L,Tanen M,Struyk A,Laterza OF

    更新日期:2014-04-01 00:00:00

  • Noninvasive Detection of Cocaine and Heroin Use with Single Fingerprints: Determination of an Environmental Cutoff.

    abstract:BACKGROUND:Recent publications have explored the possibility of using fingerprints to confirm drug use, but none has yet dealt with environmental contamination from fingertips. Here we explored the possibility of establishing an environmental cutoff for drug testing from a single fingerprint. METHODS:Fingerprint sampl...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2017.281469

    authors: Ismail M,Stevenson D,Costa C,Webb R,de Puit M,Bailey M