Comparative evaluation of ballet-type and conventional stent graft configurations for endovascular aneurysm repair: A CFD analysis.

Abstract:

PURPOSE:Cross limb stent graft (SG) configuration technique for endovascular aneurysm repair (EVAR) is employed for splayed aortic bifurcations to avoid device kinking and smoothen cannulation. The present study investigates three types of stent graft (SG) configurations for endovascular aneurysm repair (EVAR) in abdominal aortic aneurysm. A computational fluid dynamic analysis was performed on the pulsatile non-Newtonian flow characteristics in three ideally modeled geometries of abdominal aortic (AA) SG configurations. METHODS:The three planar and crosslimb SG configurations were ideally modeled, namely, top-down nonballet-type, top-down ballet-type, and bottom-up nonballet-type configurations. In top-down SG configuration, most of the device is deployed in the main body in the vicinity of renal artery and the limbs are extended to the iliac artery. While in the bottom-up configuration, some of the SG device is deployed in the main body, the limbs are deployed in aortic bifurcation, and the extra stent graft of the main body is extended to the proximal aorta until the below of the renal artery. The effects of non-Newtonian pulsatile flow on the wall stresses and flow patterns of the three models were investigated and compared. Moreover, the average wall shear stress (AWSS), oscillatory shear stress index (OSI), absolute helicity, pressure distribution, graft displacement and flow visualization plots were analyzed. RESULTS:The top-down ballet-type showed less branch blockage effect than the top-down nonballet-type models. Furthermore, the top-down ballet-type configuration showed an increased tendency to sustain high WSS and higher helicity characteristics than that of the bottom-up and top-down non-ballet type configurations. However, displacement forces of the top-down ballet-type configuration were 40%and 9.6%higher than those of the bottom-up and top-down nonballet-type configurations, respectively. CONCLUSIONS:Some complications such as graft tearing, thrombus formation, limb disconnection during long term follow up periods might be relevant to hemodynamic characteristics according to the configurations of EVAR. Hence, the reported data required to be validated with the clinical results.

authors

Ashraf F,Ambreen T,Park CW,Kim DI

doi

10.3233/CH-200996

subject

Has Abstract

pub_date

2021-01-13 00:00:00

eissn

1386-0291

issn

1875-8622

pii

CH200996

pub_type

杂志文章
  • Contrast-enhanced ultrasonography (CEUS) using early dynamic in microcirculation for localization of pathological parathyroid glands: first-line or complimentary diagnostic modality?

    abstract:BACKGROUND:Contrast-enhanced ultrasonography (CEUS) represents a new diagnostic tool to localize pathological parathyroid glands. The aim of this study was to differentiate the capability of CEUS as first-line or complimentary modality for the detection of hyperfunctioning parathyroid glands. METHODS:Sixty patients wi...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2011-1459

    authors: Hornung M,Jung EM,Stroszczynski C,Schlitt HJ,Agha A

    更新日期:2011-01-01 00:00:00

  • Hemorheology and heart rate variability: is there a relationship?

    abstract::The aim of the present study was to test the relationships between hemorheology and autonomic nervous system (ANS) activity in 23 sickle cell trait (SCT) carriers and 17 control subjects. Hemorheological parameters were assessed at rest. Nocturnal ANS activity was calculated from heart rate variability indices. Impair...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Connes P,Hue O,Hardy-Dessources MD,Boucher JH,Pichot V,Barthélémy JC

    更新日期:2008-01-01 00:00:00

  • Challenges for microcirculation research in developing countries.

    abstract:BACKGROUND:Microvascular dysfunction is a main contributor to morbidity and mortality worldwide. Sophisticated technical tools (e.g. miniaturized hardware, automated software), along with skilled personnel are the prerequisite for quantitative observations of the microvasculature. OBJECTIVE:This review aimed to get an...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:10.3233/CH-190611

    authors: Islam S,Ahmed N,Rivu SF,Khalil M,Tanjia N,Lehmann C

    更新日期:2019-01-01 00:00:00

  • Elevated plasma nitric oxide metabolites in hypertension: synergistic vasodepressor effects of a static magnetic field and nicardipine in spontaneously hypertensive rats.

    abstract::The involvement of plasma nitric oxide metabolites (NO(x)) in hypertension was examined in stroke-resistant spontaneously hypertensive rats during the development of hypertension. Continuous application of a static magnetic field (SMF; a maximum magnetic flux density of 180 millitesla, a peak magnetic gradient of 133 ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Okano H,Ohkubo C

    更新日期:2006-01-01 00:00:00

  • Studies on metabolically depleted erythrocytes.

    abstract::Erythrocytes kept outside the blood circulation undergo progressive changes in metabolism, shape and function, which was the topic of this study. For that purpose, blood anticoagulated with either heparin, citrate or EDTA was incubated at temperatures of 5°C, 22°C or 37°C for 0 h, 24 h and 48 h, respectively. A temper...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-131682

    authors: Reinhart SA,Schulzki T,Bonetti PO,Reinhart WH

    更新日期:2014-01-01 00:00:00

  • Splenic function and red blood cell deformability: The beneficial effects of spleen autotransplantation in animal experiments.

    abstract::Erythrocyte deformability could be a suitable parameter reflecting hyposplenic-asplenic conditions after splenectomy or spleen autotransplantation. The aim of this study was to analyze the efficacy of spleen autotransplantation using filtrometry and ektacytometry for testing erythrocyte deformability, besides complex ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2010-1307

    authors: Miko I,Nemeth N,Sajtos E,Brath E,Peto K,Furka A,Szabo G,Kiss F,Imre S,Furka I

    更新日期:2010-01-01 00:00:00

  • Biochemical relevance between oxidative/carbonyl stress and elevated viscosity of erythrocyte suspensions.

    abstract::The effects of various aldehydes such as secondary products of peroxidized lipids and other aldehydes on rheological parameters and their relation with aging process were studied. Malondialdehyde (MDA) in different concentrations can increase significantly viscosity and plastic viscosity of erythrocytes suspended in p...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Liu X,Qin W,Yin D

    更新日期:2004-01-01 00:00:00

  • The influence of pulsed electromagnetic field therapy (PEMFT) on cutaneous blood flow in healthy volunteers1.

    abstract:BACKGROUND:The biophysical interaction induced by low energy pulsed electromagnetic field therapy (PEMFT) on the capillary microcirculation is not well understood. Several studies indicate a significant effect of PEMFT in patients with chronic medical conditions. OBJECTIVE:The aim of this study was to evaluate the inf...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-209224

    authors: Biermann N,Sommerauer L,Diesch S,Koch C,Jung F,Kehrer A,Prantl L,Taeger CD

    更新日期:2020-01-01 00:00:00

  • Shear resistance of human umbilical endothelial cells on different materials covered with or without extracellular matrix: controlled in-vitro study.

    abstract::A variety of medical grade polymeric materials are used in tissue engineering and biomedical technology. Dense non-porous polymeric foils were used as substrates for endothelial cell layers. Half a the test samples (polymers and control materials) were seeded with bovine corneal endothelial cells (BCEC) which more or ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2009-1230

    authors: Hoepken S,Fuhrmann R,Jung F,Franke RP

    更新日期:2009-01-01 00:00:00

  • Association of hematological parameters with insulin resistance, insulin sensitivity, and asymptomatic cerebrovascular damage: the J-SHIP and Toon Health Study.

    abstract:BACKGROUND:Elevated hematocrit levels have been suggested to be an independent determinant of insulin resistance and type 2 diabetes. To clarify the diagnostic significance of hematocrit level, we investigated the association with hemodynamic profiles, insulin resistance and insulin sensitivity, arterial properties, an...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2012-1634

    authors: Tabara Y,Igase M,Saito I,Nishida W,Kohara K,Sakurai S,Kawamura R,Okada Y,Hitsumoto S,Onuma H,Nagai T,Takata Y,Uetani E,Takita R,Kido T,Ochi N,Osawa H,Tanigawa T,Miki T

    更新日期:2013-01-01 00:00:00

  • Increased hematocrit and reduced blood pressure following control of glycemia in diabetes.

    abstract::In this study we determine the effects of reducing blood glucose on mean arterial blood pressure (MAP) and hematocrit (Hct) in patients with type 2 diabetes who are not responding to conventional treatment in an intensive treatment program 1 year after initiation of treatment. Data on MAP, glucose and Hct was obtained...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 临床试验,杂志文章

    doi:

    authors: Salazar Vázquez BY,Salazar Vázquez MA,Venzor VC,Negrete AC,Cabrales P,Díaz JS,Intaglietta M

    更新日期:2008-01-01 00:00:00

  • Erythrocyte deformability in morbid obesity before bariatric surgery. Influence of abdominal obesity.

    abstract::Although there are several studies dealing with erythrocyte deformability (ED) in obese patients, research on this topic in morbidly obese subjects is scarce. In these studies ED seems to be decreased, although the cause remains unknown. A case-control study in 76 morbid obese subjects (23 women and 53 men, aged 44 ± ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2010-1357

    authors: Vayá A,Cámara R,Hernádez-Mijares A,Romagnoli M,Solá E,Corella D,Laiz B

    更新日期:2010-01-01 00:00:00

  • Chronic pharmacological preconditioning against ischemia.

    abstract::Despite decades of research and thousands of experimental publications, acute preconditioning strategies have yet to be implemented in clinical practice. While some have attributed this to a failure of the experimental studies to mimic the clinical environment, others have suggested that acute preconditioning strategi...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:10.3233/CH-2011-1479

    authors: Luca MC,Liuni A,Muxel S,Münzel T,Forconi S,Gori T,Parker JD

    更新日期:2011-01-01 00:00:00

  • B-flow and B-flow with 3D and SRI postprocessing before intervention and monitoring after stenting of the internal carotid artery.

    abstract:OBJECTIVE:To investigate the extent to which B-flow and B-flow with 3D postprocessing and speckle reduction imaging (SRI) have advantages in appraising the morphology of a high-grade stenosis of the internal carotid artery (ICA) for preinterventional planning and for postinterventional ultrasonographic follow-up. MATE...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Jung EM,Kubale R,Clevert DA,Weskott HP,Prantl L,Herold T,Renz M,Rupp N,Tacke J

    更新日期:2007-01-01 00:00:00

  • Microvascular vasodilatory responses to electric acupuncture in rat brain under acute hemorrhagic hypotension.

    abstract::The present experiment attempted to evaluate the effect of electrical acupuncture on the cerebral microcirculation in anesthetized rats, using fluorescence videomicroscopy. Changes in the pial arteriolar diameter under acute hemorrhagic hypotension were examined quantitatively. The present results suggest that acupunc...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Niimi H,Yamaguchi S,Hu QH,Zhuang FY

    更新日期:2000-01-01 00:00:00

  • Astroglial swelling for removed rat brain enlargement incubated in deoxygenated mock cerebrospinal fluid.

    abstract::The source and target of edema fluid for ischemic brain swelling clinically often observed in "malignant infarction" was examined in ex vivo. Wister rat brain hemispheres were removed and incubated air-tightly in a deoxygenated artificial cerebrospinal fluid at 37 degrees for 30 min. Ionic movement into the brain tiss...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Osada T,Tomita M,Tanahashi N,Takeda H,Nagai T,Suzuki N

    更新日期:2006-01-01 00:00:00

  • Erythrocyte deformability reduction in various pediatric hematologic diseases.

    abstract:BACKGROUND:Previously, hemorheology studies using Rheoscan mainly focused on chronic kidney disease, cardiovascular disease, and endocrine disease in adults. The study using LORCA focused on erythrocyte disease. There were no studies using Rheoscan in children. OBJECTIVE:We aimed to investigate erythrocyte deformabili...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-200817

    authors: Kim YK,Lim YT,Suh JS,Hah JO,Lee JM

    更新日期:2020-01-01 00:00:00

  • Assessment of skin microvascular endothelial function in patients with acute unilateral vestibular syndrome.

    abstract::Abnormalities in labyrinth vasculature, resulting in labyrinth ischemia may be responsible for acute unilateral vestibular syndrome (AVS). However, since no tools for the study of the labyrinth microvasculature are available in clinical settings, labyrinth microvascular abnormalities in AVS patients (AVS-pts) can only...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2012-1554

    authors: Rossi M,Casani AP,Pesce M,Cerchiai N,Santoro G,Franceschini SS

    更新日期:2013-01-01 00:00:00

  • Effect of cytochrome P450-dependent epoxyeicosanoids on Ristocetin-induced thrombocyte aggregation.

    abstract::Epoxyeicosatrienoic acids (EETs) produced by cytochrome P450 (CYP)-dependent epoxidation of arachidonic acid (AA) inhibit thrombocyte adhesion to the vascular wall. Upon dietary omega-3 fatty acid supplementation, EETs are partially replaced by eicosapentaenoic acid (EPA)-derived epoxyeicosatetraenoic acids (EEQs) and...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-2012-1614

    authors: Jung F,Schulz C,Blaschke F,Muller DN,Mrowietz C,Franke RP,Lendlein A,Schunck WH

    更新日期:2012-01-01 00:00:00

  • Erythrocyte deformability and nitric oxide mobilization under pannexin-1 and PKC dependence.

    abstract::The erythrocyte adenosine triphosphate (ATP) is utilised for protein phosphorylation and exported through the pannexin 1 hemichannel (Px1) in the microcirculation. The physiological stimuli for ATP release are dependent of blood shear rate level and of the tissue oxygen content. The deoxygenated and oxygenated states ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-141833

    authors: Silva-Herdade AS,Freitas T,Almeida JP,Saldanha C

    更新日期:2015-01-01 00:00:00

  • μCT based assessment of mechanical deformation of designed PTMC scaffolds.

    abstract:BACKGROUND:Advances in rapid-prototyping and 3D printing technologies have enhanced the possibilities in preparing designed architectures for tissue engineering applications. A major advantage in custom designing is the ability to create structures with desired mechanical properties. While the behaviour of a designed s...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-151931

    authors: Narra N,Blanquer SB,Haimi SP,Grijpma DW,Hyttinen J

    更新日期:2015-01-01 00:00:00

  • Effects of Ramipril and Isradipin on hemorheological profiles in patients with arterial hypertension.

    abstract::In this study, the effect of the angiotensin-converting-enzyme inhibitor (ACE inhibitor) Ramipril (5 mg/day) and calcium antagonist Isradipin (5 mg/day) treatment of two groups of hypertensive patients (n = 22 in each of group) was evaluated. The parameters of the hemorheological profile (blood and plasma viscosity, r...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Muravyov AV,Zaitsev LG,Muravyov AA,Yakusevich VV,Sirotkina AM

    更新日期:1998-07-01 00:00:00

  • Tissular oxygenation and erythrocyte deformability in haemodialyzed patients using different dialytic membranes.

    abstract::We studied the effect of some dialytic membrane on tissular oxygenation (TO) and erythrocyte deformability (ED). Sixteen patients (10 M and 6 F, aged 59 +/- 12 years) have been submitted to bicarbonate dialysis (BD) and subdivided into four groups (GR) of 4 patients each: GR 1 (hemophan membrane, 35 BD), GR 2 (polyacr...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Passavanti G,Cicco G,Baldassarre G,Vicenti P,Soleti F,Stingi GD,Carbonara MC,Coratelli P,Pirrelli A

    更新日期:1999-01-01 00:00:00

  • Hemorheological changes in ischemia-reperfusion: an overview on our experimental surgical data.

    abstract::Blood vessel occlusions of various origin, depending on the duration and extension, result in tissue damage, causing ischemic or ischemia-reperfusion injuries. Necessary surgical clamping of vessels in vascular-, gastrointestinal or parenchymal organ surgery, flap preparation-transplantation in reconstructive surgery,...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章,评审

    doi:10.3233/CH-131648

    authors: Nemeth N,Furka I,Miko I

    更新日期:2014-01-01 00:00:00

  • Vascular rejection in renal transplant: Diagnostic value of contrast-enhanced ultrasound (CEUS) compared to biopsy.

    abstract:BACKGROUND:Despite of the more potent immunosuppressive medication, vascular rejection is still a major issue after renal transplantation. Renal biopsy is the gold standard diagnostic to evaluate acute and chronic allograft rejection. As it is an invasive diagnostic there is the risk of complications like haematoma, ar...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-189115

    authors: Mueller-Peltzer K,Negrão de Figueiredo G,Fischereder M,Habicht A,Rübenthaler J,Clevert DA

    更新日期:2018-01-01 00:00:00

  • Possible involvement of oxidative stress in exercise-mediated platelet activation.

    abstract::In this study, we have attempted to verify whether a single bout of strenuous exercise performed by sedentary healthy individuals may interfere with the mechanisms controlling platelet sensitivity through exercise-related modifications of plasma oxidant/antioxidant equilibrium. Strenuous exercise resulted in an increa...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Di Massimo C,Scarpelli P,Tozzi-Ciancarelli MG

    更新日期:2004-01-01 00:00:00

  • IL-17 predicts the effect of TACE combined with apatinib in hepatocellular carcinoma.

    abstract:OBJECTIVE:IL-17 is considered to be a cancer-promoting gene in hepatocellular carcinoma (HCC). Here, we explored the effect of IL-17 in predicting the therapeutic effect of transcatheter arterial chemoembolization (TACE) combined with apartinib in patients with HCC in this study. METHODS:Established of IL-17 knockdown...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-200857

    authors: Wu Y,Cheng G,Chen H,Wang J,Wang J,Wang W

    更新日期:2020-07-09 00:00:00

  • Expression of MMPs and TIMPs in primary epithelial cell cultures of the upper aerodigestive tract seeded on the surface of a novel polymeric biomaterial.

    abstract:INTRODUCTION:Using standard cell biological and biochemical experimental approaches we were able to test the ability of a particular polymer construct to support the adhesion, proliferation, and the cellular acitivity of pharyngeal cells. The delicate balance between Matrix Metalloproteinases (MMPs) and their endogenou...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:

    authors: Rickert D,Lendlein A,Kelch S,Moses MA,Franke RP

    更新日期:2005-01-01 00:00:00

  • Shear-wave elastography of the testis in the healthy man - determination of standard values.

    abstract:PURPOSE:Real-time shear-wave elastography (SWE) is a newly developed technique for the sonographic quantification of tissue elasticity, which already is used in the assessment of breast and thyroid lesions. Due to limited overlying tissue, the testes are ideally suited for assessment using shear wave elastography. To o...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-162046

    authors: Trottmann M,Marcon J,D'Anastasi M,Bruce MF,Stief CG,Reiser MF,Buchner A,Clevert DA

    更新日期:2016-01-01 00:00:00

  • Laparoscopy-guided percutaneous microwave ablation for symptomatic 12.8 cm hepatic hemangioma with low blood loss and short hospital stay post-operation: A case report and literature review.

    abstract::We described a patient with symptomatic giant hepatic hemangioma (GHH) treated with laparoscopic guided percutaneous microwave ablation (MWA). A 58 years' old woman was referred to our hospital who presented with upper abdominal distension and appetite loss for more than 1 year. The medical history included untreated ...

    journal_title:Clinical hemorheology and microcirculation

    pub_type: 杂志文章

    doi:10.3233/CH-200922

    authors: Zhang HL,Meng HB,Li XL,Sun LP,Lu F,Xu HX,Yu SY

    更新日期:2020-10-13 00:00:00