Analysis of the mechanical properties of locking plates with and without screw hole inserts.

Abstract:

:The purpose of this study was to determine if the use of screw hole inserts in empty locking screw holes improves the strength and failure characteristics of locking plates. Twenty 5-hole 1/3 tubular locking plates (Synthes, Paoli, Pennsylvania) were mounted on an oak dowel with a 1-cm gap simulating a fracture with comminution and bone loss. Ten of the 1/3 tubular plates had a screw hole insert placed in the center hole (centered over the simulated fracture), while 10 of the 1/3 tubular plates remained empty in the center hole. The plate-dowel constructs were placed in an Instron 8800 Material Testing Machine and subjected to a series of loading conditions, replicating physiologic loading. The torsional and axial stiffness of each plate-dowel construct was calculated. All plates were then loaded to failure. No significant differences were found in the mechanical properties of the 2 plate constructs. Both the filled screw-hole plate constructs and unfilled screw hole plate constructs demonstrated the same torsional and axial stiffness, before and after being subjected to a combined cyclic and axial torsional load. Additionally, there was no significant difference in ultimate compressive strength or load to failure. Locking plate technology is a relatively new innovation in orthopedic fracture fixation. The evolution of new and varied applications and implants continues. Persistent, fundamental questions exist concerning the basic locking plate design. This study demonstrates that the addition of screw hole inserts does not significantly change the stiffness, torsional strength, or axial loading strength of 1/3 tubular locking plates.

journal_name

Orthopedics

journal_title

Orthopedics

authors

Eichinger JK,Herzog JP,Arrington ED

doi

10.3928/01477447-20101123-13

subject

Has Abstract

pub_date

2011-01-03 00:00:00

pages

19

issue

1

eissn

0147-7447

issn

1938-2367

journal_volume

34

pub_type

杂志文章
  • Current indications for and the technique of wrist arthroscopy.

    abstract::Since its introduction more than 30 years ago, wrist arthroscopy has become an essential diagnostic and therapeutic tool in hand surgery. This procedure minimizes exposures and allows access to otherwise remotely located anatomic regions with minimal morbidity. Advances in anatomic understanding and wrist scope techno...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20140401-07

    authors: Wagner J,Ipaktchi K,Livermore M,Banegas R

    更新日期:2014-04-01 00:00:00

  • Diagnosis and Management Strategies for Distal Biceps Rupture.

    abstract::Rupture of the distal biceps tendon most commonly is secondary to mechanical overload during eccentric muscle contraction. Due to deficits of strength and endurance, surgical repair usually is recommended. Although both single- and double-incision approaches have been described, double-incision techniques have been sh...

    journal_title:Orthopedics

    pub_type: 杂志文章,评审

    doi:10.3928/01477447-20190723-05

    authors: Holt J,Preston G,Heindel K,Preston H,Hill G

    更新日期:2019-11-01 00:00:00

  • Osteoporotic ankle fractures: an approach to operative management.

    abstract::The incidence of osteoporosis is increasing as the elderly population grows. Because these patients remain active, fragility fractures of the ankle are becoming more common. The literature indicates a relatively high complication rate for non-operative management of ankle fractures in this patient cohort, leading surg...

    journal_title:Orthopedics

    pub_type: 杂志文章,评审

    doi:10.3928/01477447-20131120-07

    authors: McKean J,Cuellar DO,Hak D,Mauffrey C

    更新日期:2013-12-01 00:00:00

  • Chemoprophylaxis without intra-articular wound drainage can replace autotransfusion in primary TKA.

    abstract::We compared outcomes in 2 groups undergoing total knee arthroplasty (TKA) with different blood-saving strategies (ie, chemoprophylaxis vs reinfusion). We hypothesized that chemoprophylaxis would lead to reduced blood loss and fewer transfusions, with no increase in associated complications. Group A was a prospective s...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20110427-11

    authors: Hourlier H,Fennema P

    更新日期:2011-06-14 00:00:00

  • Long-term Functional Outcomes of Nonoperatively Treated Highly Displaced Scapular Body and Neck Fractures.

    abstract::Historically, extra-articular scapular body fractures were treated nonsurgically, but displaced fractures of the glenoid neck can lead to dysfunction. Controversy exists regarding which extra-articular scapular fractures should be treated surgically; however, nonsurgical management of severely displaced scapular body ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20200314-05

    authors: Rajfer RA,Salopek T,Mosier BA,Miller MC,Altman GT

    更新日期:2020-05-01 00:00:00

  • Effect of olecranon resection on joint stability and strain of the medial ulnar collateral ligament.

    abstract::This study aimed to assess the effect of posteromedial olecranon resection on the stability of the elbow joint, forearm kinematics, and strain in the anterior bundle of the medial ulnar collateral ligament. Seven elbows were tested after resecting all soft tissues except the capsuloligamentous structures. Varus-valgus...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Lee YS,Alcid JG,McGarry MH,ElAttrache NS,Lee TQ

    更新日期:2008-07-01 00:00:00

  • Does morbid obesity negatively affect the hospital course of patients undergoing treatment of closed, lower-extremity diaphyseal long-bone fractures?

    abstract::Obesity is prevalent in the developed world and is associated with significant costs to the health care system. The effect of morbid obesity in patients operatively treated for long-bone fractures of the lower extremity is largely unknown. The National Trauma Data Bank was accessed to determine if morbidly obese patie...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20101123-03

    authors: Baldwin KD,Matuszewski PE,Namdari S,Esterhai JL,Mehta S

    更新日期:2011-01-03 00:00:00

  • Soft-tissue chondroma.

    abstract::Soft-tissue chondromas are rare and benign soft-tissue tumors. Over 95% occur in the hands and feet. They are seen in both sexes equally and mainly occur in patients aged 30-60 years. If excised fully, they do not reoccur, and no cases in the literature have reported malignant transformations. ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20070301-13

    authors: Gentles C,Perin J,Berrey H,Griffiths HJ

    更新日期:2007-03-01 00:00:00

  • Comparative study of unilateral and bilateral pedicle screw fixation in posterior lumbar interbody fusion.

    abstract::A prospective, randomized clinical study was performed to determine whether unilateral pedicle screw fixation was comparable with bilateral fixation in 1- or 2-segment lumbar interbody fusion. One hundred eight patients with lumbar degenerative diseases were randomly assigned to the unilateral (n=56) or bilateral (n=5...

    journal_title:Orthopedics

    pub_type: 杂志文章,随机对照试验

    doi:10.3928/01477447-20120919-22

    authors: Xie Y,Ma H,Li H,Ding W,Zhao C,Zhang P,Zhao J

    更新日期:2012-10-01 00:00:00

  • Acid hydrolase activity following allografting.

    abstract::The synovium of dogs receiving an osteochondral allograft of the distal femur has similar characteristics to a rheumatoid synovium. Since it is generally believed that the cartilage destruction in rheumatoid arthritis is related to the release of hydrolases from lysosomes, the following study was performed to determin...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19820701-05

    authors: Yablon IG,Shirahama T

    更新日期:1982-07-01 00:00:00

  • Anatomic and radiographic analysis of arthroscopic tack placement into the anteroinferior glenoid.

    abstract::Tack location within the anteroinferior aspect of the glenoid when performing simulated repairs of anteroinferior capsulolabral avulsions (Bankart lesions) was evaluated anatomically and radiographically. Arthroscopy was performed on six fresh-frozen cadaveric shoulders, and bioabsorbable tacks were placed through an ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Ilahi OA,Younas SA,Trusler ML,Espiritu MT

    更新日期:2003-05-01 00:00:00

  • External fixation in the management of severe musculoskeletal trauma.

    abstract::External fixation was employed in 33 open extremity fractures in 29 patients. These high energy injuries were characterized by massive soft tissue injury, contamination, instability, comminution, and/or segmental bone loss. Initial management consisted of irrigation and debridement, and application of the external fix...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19810401-07

    authors: Hardaker WT,Ward WT,Goldner JL

    更新日期:1981-04-01 00:00:00

  • Once Annealed Highly Cross-Linked Polyethylene Exhibits Low Wear at 9 to 15 Years.

    abstract::A once annealed highly cross-linked polyethylene (HXLPE) was introduced in 1998. Concerns regarding its long-term performance and oxidative resistance exist because of the presence of retained free radicals. The authors studied 48 patients with 50 hip implants having an average age of 62 years. They were followed for ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20160414-03

    authors: D'Antonio J,Capello WN,Ramakrishnan R

    更新日期:2016-05-01 00:00:00

  • Prescription options for the below knee amputee. A review.

    abstract::In 1973 a workshop sponsored by the National Academy of Sciences recommended that "efforts to develop prescription criteria for use of the numerous variants of the BK prosthesis should be intensified." This paper provides a review of the important considerations in the prescription of a below-knee prosthesis. It is in...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Abrahamson MA,Skinner HB,Effeney DJ,Wilson LA

    更新日期:1985-02-01 00:00:00

  • Biological fixation of a modified moore prosthesis.

    abstract::Clinical experience with a poroussurfaced modified Moore prosthesis designed for biological fixation is described. Principles of noncemented arthroplasty including details of patient selection, implant design and selection, and surgical technique are emphasized. Analysis of the first 100 patients with a minimum follow...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19840201-15

    authors: Engh CA,Bobyn JD,Gorski JM

    更新日期:1984-02-01 00:00:00

  • Femoral fixation in primary total hip arthroplasty.

    abstract::We have presented the major advantages of using femoral components that have porous coating over the entire stemmed portion and have a cylindrical distal shape. The advantages of a stem with these design features also are reflected in the changing pattern of hip implant usage. A decade ago, the most frequently used po...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Engh CA Sr,Culpepper WJ 2nd

    更新日期:1997-09-01 00:00:00

  • Proportion of Obese Patients Presenting to Orthopedic Total Joint Arthroplasty Clinics.

    abstract::The purpose of this study is to demonstrate that the percentage of obese individuals initially presenting to total joint arthroplasty clinics in a public, tertiary hospital is greater than the proportion of obese individuals in the general population. In a retrospective, comparative study of patients seen in total joi...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20151222-12

    authors: Welton KL,Gagnier JJ,Urquhart AG

    更新日期:2016-01-01 00:00:00

  • Variation in Optimal Sagittal Alignment of the Femoral Component in Total Knee Arthroplasty.

    abstract::Accurate sagittal alignment of the femoral component in total knee arthroplasty is crucial for prosthesis longevity, improved function, and patient satisfaction. However, there is variation in the techniques used to attain optimal sagittal femoral component placement in total knee arthroplasty. Femoral component flexi...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20161108-04

    authors: Hood B,Blum L,Holcombe SA,Wang SC,Urquhart AG,Goulet JA,Maratt JD

    更新日期:2017-03-01 00:00:00

  • Complications With Long Cemented Stems in Proximal Femoral Replacement.

    abstract::This study attempted to determine whether patients undergoing cemented long-stem proximal femoral replacement had: (1) an increased short-term mortality rate; (2) greater intraoperative hemodynamic instability; (3) a greater need for resuscitation; and (4) a decreased risk of periprosthetic fracture. The current study...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20160404-04

    authors: Naik AA,Lietman SA

    更新日期:2016-05-01 00:00:00

  • Total joint replacement in patients with dementia syndromes: a report of thirteen cases.

    abstract::The hospital course and clinical outcomes of 14 joint replacement surgeries in 13 patients with dementia syndromes were evaluated. Eight patients were disoriented postoperatively. Complications included slow progress in physical therapy, getting out of bed unattended, aggressive behavior, pulling out an intravenous or...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Ritter MA,Harty LD

    更新日期:2004-05-01 00:00:00

  • Fracture of polyethylene tibial component in a total knee replacement. A case report.

    abstract::Aseptic loosening is the most common mode of failure for total knee replacements. Component breakage is rare, usually attributable to errors of design or manufacture. A case is presented in which rotational malplacement of the femoral component resulted in accelerated wear and eventual fracture of the polyethylene tib...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Mowery C,Botte M,Bradley G

    更新日期:1987-02-01 00:00:00

  • Accuracy of navigation: a comparative study of infrared optical and electromagnetic navigation.

    abstract::We evaluated the accuracy of navigation systems for measuring the mechanical axis in patients undergoing total knee arthroplasty and in the synthetic bone model. Infrared optical and electromagnetic navigation systems were compared. Both systems were found to be accurate and reproducible in an experimental environment...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Song EK,Seon JK,Park SJ,Yoon TR

    更新日期:2008-10-01 00:00:00

  • Functional assessment using the step-up-and-over test and forward lunge following ACL reconstruction.

    abstract::This investigation compared lower extremity function of a control group and a group of patients who underwent anterior cruciate ligament (ACL) reconstruction using a repeated measures post-test only control group design. The ACL reconstruction group consisted of 18 patients at least 6 months postoperative (mean 58+/-1...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Mattacola CG,Jacobs CA,Rund MA,Johnson DL

    更新日期:2004-06-01 00:00:00

  • Short-term Medical Complications Following Short Versus Long Cephalomedullary Nails.

    abstract::The purpose of this retrospective cohort study was to evaluate whether there is an increased rate of short-term medical complications following short vs long cephalomedullary nails for the treatment of intertrochanteric hip fractures. A total of 899 patients treated surgically with cephalomedullary nails from January ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20180711-03

    authors: Liu J,Frisch NB,Mehran N,Qatu M,Guthrie ST

    更新日期:2018-09-01 00:00:00

  • MRI of peripheral neurofibromas in children.

    abstract::Magnetic resonance imaging was performed as a preoperative examination in three children with neurofibromatosis and soft-tissue plexiform neurofibromas. In all three patients, MRI showed more widespread soft tissue involvement than was suspected clinically including extension towards the spine in each case. Patient ma...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Glasier CM,Williamson MR,Lange TA

    更新日期:1989-02-01 00:00:00

  • Original technique for noninvasive electric stimulation designed for the hoffmann® fixator.

    abstract::The standard Hoffmann fixator is ideal for electrical stimulation, using the pins as electrodes and the frame for fixation of the fracture and the stimulator. The main problem in this method of stimulation is the corrosion of the pins, which are made of stainless steel. Through 12 years of clinical research on human f...

    journal_title:Orthopedics

    pub_type: 社论

    doi:10.3928/0147-7447-19840301-09

    authors: Jørgensen TE

    更新日期:1984-03-01 00:00:00

  • The Role of Aspirin and Unfractionated Heparin Combination Therapy Immediately After Total Hip and Knee Arthroplasty.

    abstract::Aspirin and unfractionated heparin (UH) are accepted options for venous thromboembolism (VTE) prophylaxis after total joint arthroplasty (TJA). The use of aspirin in addition to UH in preventing VTE after TJA has yet to be studied. The primary objective of this study was to determine VTE rates in patients receiving as...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:10.3928/01477447-20180320-08

    authors: Sobh AH,Koueiter DM,Mells A,Siljander MP,Karadsheh MS

    更新日期:2018-05-01 00:00:00

  • Eight- to ten-year results of a variable geometry stem.

    abstract::This prospective study was conducted on 108 consecutive implantations straight, cementless, taper-designed stem with variable lateral flare (Pegasus; DePuy, Warsaw, Indiana) at an 8- to 10-year follow-up; DEXA scanning was performed at 3 and 12 months on a second cohort of 40 patients. The mean Harris hip score was 94...

    journal_title:Orthopedics

    pub_type: 杂志文章,多中心研究

    doi:10.3928/01477447-20071101-09

    authors: Gallinaro P,Massè A,Leonardi F,Buratti CA,Boggio F,Piana R

    更新日期:2007-11-01 00:00:00

  • The orthopedic and social outcome of open tibia fractures in children.

    abstract::To determine whether the accepted principles of management of open tibia fractures apply to children, 40 consecutive open fractures of the tibial shaft in skeletally immature patients were retrospectively reviewed. Attempts were made to evaluate the functional and social impact of open tibia fractures in children. All...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Levy AS,Wetzler M,Lewars M,Bromberg J,Spoo J,Whitelaw GP

    更新日期:1997-07-01 00:00:00

  • Radiologic case study. Rupture of the long head of the biceps tendon.

    abstract::Rupture of the long head of the biceps tendon frequently is encountered in the setting of coexisting rotator cuff pathology and chronic impingement, but traumatic rupture is occasionally seen, as in this case. Signs and symptoms are not always diagnostic, and MRI or MR arthrography can be a useful tool for evaluation ...

    journal_title:Orthopedics

    pub_type: 杂志文章

    doi:

    authors: Khanna G,Glockner JF,Sundaram M

    更新日期:2000-08-01 00:00:00