Use of a monoclonal antibody for the therapeutic monitoring of cyclosporine in plasma and whole blood.

Abstract:

:The evaluation of a radioimmunoassay (RIA) for the monitoring of cyclosporine (CSA) that utilizes a monoclonal antibody specific for the parent compound is described. The assay exhibited good analytical recovery (greater than 95%), precision (coefficient of variation less than 10%), and linearity in plasma and whole blood specimens. The percentage cross reactivity of the major CSA metabolites M-17, M-1, and M-21 was less than 2%. The RIA gave values that were on average indistinguishable from those obtained by high-pressure liquid chromatography in plasma and whole blood specimens obtained from 49 renal transplant recipients.

journal_name

Ther Drug Monit

authors

Copeland KR,Yatscoff RW

doi

10.1097/00007691-198804000-00013

subject

Has Abstract

pub_date

1988-01-01 00:00:00

pages

453-8

issue

4

eissn

0163-4356

issn

1536-3694

journal_volume

10

pub_type

杂志文章
  • Plasma assay of salbutamol by means of high-performance liquid chromatography with amperometric determination using a loop column for injection of plasma extracts. Application to the evaluation of subcutaneous administration of salbutamol.

    abstract::An isocratic high-performance liquid chromatography method with amperometric detection for the assay of plasma salbutamol is described. The plasma extract is injected into the chromatographic system via a loop column. This insures the purification of the injected extracts and allows a simple and rapid liquid-solid ext...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-199206000-00011

    authors: Tamisier-Karolak L,Delhotal-Landes B,Jolliet-Riant P,Milliez J,Jannet D,Barre J,Flouvat B

    更新日期:1992-06-01 00:00:00

  • Should 6-thioguanine nucleotides be monitored in heart transplant recipients given azathioprine?

    abstract::The commonly used immunosuppressive regimen after orthotopic heart transplantation consists of cyclosporine (CsA), azathioprine (AZA), and steroids. Although AZA therapy is generally regarded as unproblematic, its use can be associated with severe side effects, particularly myelosuppression. Since AZA is a prodrug, wh...

    journal_title:Therapeutic drug monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00007691-199606000-00002

    authors: Schütz E,Gummert J,Mohr FW,Armstrong VW,Oellerich M

    更新日期:1996-06-01 00:00:00

  • Possible interaction between acyclovir and antiepileptic treatment.

    abstract::We report a clinically relevant suspected interaction between acyclovir and the antiepileptic drugs phenytoin (PHT) and valproic acid (VPA). In a child receiving PHT and VPA therapy, a 6-day acyclovir treatment reduced PHT and VPA plasma concentrations to subtherapeutic values. This probably worsened both clinical sta...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:

    authors: Parmeggiani A,Riva R,Posar A,Rossi PG

    更新日期:1995-06-01 00:00:00

  • Assessment of cyclosporin A in whole blood and plasma in five patients with different hematocrits.

    abstract::Measurement of whole blood and plasma levels of cyclosporin A (CsA) by radioimmunoassay in kidney transplant recipients receiving the drug showed that CsA concentrations in plasma increased nonlinearly when whole blood levels of the drug exceeded 1,000 ng/ml. At low plasma levels (less than 200 ng/ml), most of the CsA...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-198503000-00010

    authors: Agarwal RP,McPherson RA,Threatte GA

    更新日期:1985-01-01 00:00:00

  • Δ9-Tetrahydrocannabinol and Cannabidiol Time Courses in the Sera of "Light Cannabis" Smokers: Discriminating Light Cannabis Use from Illegal and Medical Cannabis Use.

    abstract:BACKGROUND:Δ9-tetrahydrocannabinol (THC) and cannabidiol (CBD) time courses in serum and physiological and behavioral effects associated with smoking 1 or 4 "light cannabis" cigarettes were studied. Biomarkers to differentiate light cannabis versus illegal and medical cannabis use were also investigated. METHODS:Sera ...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000683

    authors: Pichini S,Mannocchi G,Berretta P,Zaami S,Pirani F,Pacifici R,Busardò FP

    更新日期:2020-02-01 00:00:00

  • Multicenter analytical evaluation of the automated electrochemiluminescence immunoassay for cyclosporine.

    abstract:BACKGROUND:Cyclosporine A (CsA) is used as a posttransplantation immunosuppressant drug, and careful monitoring of CsA concentration in whole blood is essential. A new automated electrochemiluminescence immunoassay (ECLIA) for CsA measurement has been assessed in a multicenter evaluation. METHODS:Residual EDTA whole b...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/FTD.0000000000000068

    authors: Vogeser M,Shipkova M,Rigo-Bonnin R,Wallemacq P,Orth M,Widmann M,Verstraete AG

    更新日期:2014-10-01 00:00:00

  • Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay.

    abstract::The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT ass...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章,多中心研究

    doi:10.1097/FTD.0b013e3181d46386

    authors: Wallemacq P,Maine GT,Berg K,Rosiere T,Marquet P,Aimo G,Mengozzi G,Young J,Wonigeit K,Kretschmer R,Wermuth B,Schmid RW

    更新日期:2010-04-01 00:00:00

  • Evaluation of therapeutic drug monitoring of methotrexate in saliva of children with rheumatic diseases.

    abstract::Pediatric patients with leukemia, other malignancies, and rheumatological disease receive methotrexate chronically. Because of the documented correlation between methotrexate levels of compliance and clinical outcome, it is conceivable to verify appropriate systemic exposure to the drug. Saliva sampling may be of pote...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-199506000-00006

    authors: Press J,Berkovitch M,Laxer R,Giesbrecht E,Verjee Z,Silverman E,Klein J,Koren G

    更新日期:1995-06-01 00:00:00

  • Prescribing patterns and the use of therapeutic drug monitoring of psychotropic medication in a psychiatric high-security unit.

    abstract::The aim of this study was to investigate the use of psychotropic medication and therapeutic drug monitoring in a high-security psychiatric unit and to compare the doses and serum concentrations both with the recommended intervals and with the doses and serum concentrations in a control group. One hundred thirty-two pa...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0b013e31818622c4

    authors: Castberg I,Spigset O

    更新日期:2008-10-01 00:00:00

  • Tacrolimus Exposure in Obese Patients: A Case-Control Study in Kidney Transplantation.

    abstract:BACKGROUND:Tacrolimus pharmacokinetics in obese patients have been poorly studied. Herein, the authors explored the impact of obesity on tacrolimus exposure in kidney transplant recipients (KTRs) and estimated a more suitable initial dosage in this population. METHODS:A retrospective, observational, monocentric case-c...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000820

    authors: Robert V,Manos-Sampol E,Manson T,Robert T,Decourchelle N,Anne-Sophie G,Quaranta S,Moal V,Legris T

    更新日期:2020-10-05 00:00:00

  • Simultaneous determination of seven tricyclic antidepressant drugs in human plasma by direct-injection HPLC-APCI-MS-MS with an ion trap detector.

    abstract::A sensitive and specific direct-injection high-performance liquid chromatography-atmospheric pressure chemical ionization tandem mass-spectrometry (HPLC-APCI-MS-MS) method has been developed for the rapid identification and quantitation of seven tricyclic antidepressants-amitriptyline, nortriptyline, doxepin, dosulepi...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-200208000-00013

    authors: Kollroser M,Schober C

    更新日期:2002-08-01 00:00:00

  • A simple fluorescence high-performance liquid chromatographic assay for dihydroquinidine in serum.

    abstract::A simple and rapid reversed-phase C-18 high-performance liquid chromatography (HPLC) assay without a prior extraction step for dihydroquinidine (HQD) in serum is described. The method is selective and useful for monitoring HQD and its presumed metabolites, quinidine (QD), N-oxide QD, 3-hydroxy QD (3-OHQD), and 10-11-d...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-198412000-00017

    authors: Camsonne R,Moulin MA,Albessard F,Perault M

    更新日期:1984-01-01 00:00:00

  • Enantioselective analysis of citalopram and metabolites in adolescents.

    abstract::Studies of the antidepressant effect and pharmacokinetics of citalopram have been performed in adults, but the effects on children and adolescents have only been studied to a minor extent despite its increasing use in these age groups. The aim of this study was to investigate a group of adolescents treated for depress...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-200112000-00011

    authors: Carlsson B,Olsson G,Reis M,Walinder J,Nordin C,Lundmark J,Scordo MG,Dahl ML,Bengtsson F,Ahlner J

    更新日期:2001-12-01 00:00:00

  • Impact of Laboratory Practices on Interlaboratory Variability in Therapeutic Drug Monitoring of Immunosuppressive Drugs.

    abstract::The immunosuppressants cyclosporine, tacrolimus, sirolimus, everolimus, and probably also mycophenolic acid require therapeutic drug monitoring (TDM)-guided dosing to ensure that blood concentrations are kept within the target range in transplant patients. Reliable, accurate, and precise test methods are therefore ess...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000205

    authors: Christians U,Vinks AA,Langman LJ,Clarke W,Wallemacq P,van Gelder T,Renjen V,Marquet P,Meyer EJ

    更新日期:2015-12-01 00:00:00

  • Aluminum toxicity in patients with chronic renal failure.

    abstract::During the past two decades, in association with the commencement of chronic dialysis therapy and prolongation of the uremic state, aluminum toxicity has represented a major cause of morbidity and mortality in uremic patients. The uremic patient has been found to be at higher risk of aluminum loading and toxicity from...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00007691-199312000-00025

    authors: Alfrey AC

    更新日期:1993-12-01 00:00:00

  • A simple method for quantifying fentanyl, sufentanil, or morphine in discard syringes from anesthesia procedures.

    abstract::Fentanyl, sufentanil, and morphine are commonly used in the conduct of anesthesia. Medical staff working with these drugs are at high risk of addiction. To detect and prevent diversion, a method was developed to quantify these drugs in discard syringes using the BioRad REMEDi HS Drug Profiling System. For fentanyl, th...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-200210000-00014

    authors: Holth LS,Friesen R,Green C,Krahn J

    更新日期:2002-10-01 00:00:00

  • Risk Assessment of Drug-Drug Interactions of Calcineurin Inhibitors Affecting Sirolimus Pharmacokinetics in Renal Transplant Patients.

    abstract:BACKGROUND:Sirolimus is a mammalian target of rapamycin inhibitor that is being used to prevent organ rejection in kidney transplant patients often in combination with calcineurin inhibitors (CNIs; cyclosporine and tacrolimus). All 3 drugs are metabolized primarily by CYP3As. Clinical drug-drug interaction (DDI) studie...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000314

    authors: Emoto C,Vinks AA,Fukuda T

    更新日期:2016-10-01 00:00:00

  • A prospective evaluation of therapeutic drug monitoring.

    abstract::Since therapeutic drug monitoring is rapidly becoming a widely used tool in clinical medicine, we prospectively assessed 390 serum drug assays over a 4-week period to determine the appropriateness of serum sample collection. The results of appropriately collected samples were used to evaluate the ability of the physic...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-198309000-00002

    authors: Bussey HI,Hoffman EW

    更新日期:1983-01-01 00:00:00

  • Quantification of immunosuppression by flow cytometry in stable renal transplant recipients.

    abstract::The current standard of monitoring transplant patients by drug levels is not optimal because it does not take into account the different and individual effects of immunosuppressive drugs on each patient. In this study, the authors tested immune function assays for monitoring transplant patients. Blood was collected fr...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-200302000-00003

    authors: Stalder M,Bîrsan T,Holm B,Haririfar M,Scandling J,Morris RE

    更新日期:2003-02-01 00:00:00

  • A simple method to calculate cyclosporine dosage to obtain a target C2 drug level.

    abstract::C(2) Cyclosporine (CsA) level, as a surrogate of area under the time-concentration curve (AUC) 0-4 hours, is a good predictor of drug absorption and clinical outcome after kidney transplantation. It has been difficult to define the optimal C(2) level in the individual case and given the broad range of C(2) due to inte...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-200306000-00022

    authors: Morales J,Buckel E,Fierro A,Zehnder C,Herzog C,Mañalich J

    更新日期:2003-06-01 00:00:00

  • Sensitive determination of itraconazole and its active metabolite in human plasma by column-switching high-performance liquid chromatography with ultraviolet detection.

    abstract::A simple and sensitive column-switching high-performance liquid chromatographic method for the simultaneous determination of itraconazole (ITZ) and its active metabolite, hydroxyitraconazole (HIT) in human plasma is described. ITZ, HIT, and an internal standard, R051012, were extracted from 1 mL of alkalinized plasma ...

    journal_title:Therapeutic drug monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00007691-200608000-00007

    authors: Uno T,Shimizu M,Sugawara K,Tateishi T

    更新日期:2006-08-01 00:00:00

  • Quality Assessment of Dried Blood Spots from Patients With Tuberculosis from 4 Countries.

    abstract:BACKGROUND:Dried blood spot (DBS) sampling is a blood collection tool that uses a finger prick to obtain a blood drop on a DBS card. It can be used for therapeutic drug monitoring, a method that uses blood drug concentrations to optimize individual treatment. DBS sampling is believed to be a simpler way of blood collec...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000659

    authors: Zuur MA,Veenhof H,Aleksa A,Vanʼt Boveneind-Vrubleuskaya N,Darmawan E,Hasnain MG,Heysell SK,Jongedijk EM,Koster RA,Magis-Escurra C,Martinez N,Molinas G,Mondal D,Mulyani UA,Perwitasari DA,Tsivunchyk A,Touw DJ,Alffenaar JC

    更新日期:2019-12-01 00:00:00

  • New modified fluorescence polarization immunoassay does not falsely elevate vancomycin concentrations in patients with end-stage renal disease.

    abstract::Recent literature has urged caution in the interpretation of vancomycin serum concentrations in patients with end-stage renal disease (ESRD), because falsely elevated levels in excess of 70% have been reported with the most commonly used fluorescence polarization immunoassay (FPIA). The purpose of this study was to ev...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-199804000-00016

    authors: Smith PF,Petros WP,Soucie MP,Copeland KR

    更新日期:1998-04-01 00:00:00

  • Factors associated with long-term renal allograft survival.

    abstract::Major advances in immunosuppression and reductions in the rates of acute rejection have led to increasing graft and patient survival rates during the past two decades. Chronic dysfunction of the renal allograft, however, remains a major clinical problem and probably represents the end result of the complex interplay b...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00007691-200202000-00007

    authors: Kaplan B,Srinivas TR,Meier-Kriesche HU

    更新日期:2002-02-01 00:00:00

  • No pharmacokinetic but pharmacodynamic interactions between cisapride and bromperidol or haloperidol.

    abstract::Pharmacokinetic and pharmacodynamic interactions between the gastrokinetic drug cisapride and the antipsychotic drugs bromperidol and haloperidol were studied in 29 schizophrenic inpatients. Fourteen patients were taking bromperidol (12-24 mg/d), and 15 were taking haloperidol (12-36 mg/d). Cisapride 10 mg/d was coadm...

    journal_title:Therapeutic drug monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/00007691-199906000-00007

    authors: Mihara K,Otani K,Yasui N,Ishida M,Kondo T,Suzuki A,Furukori H,Nagashima U,Kaneko S,Inoue Y

    更新日期:1999-06-01 00:00:00

  • A Dried Blood Spot Analysis for Solithromycin in Adolescents, Children, and Infants: A Short Communication.

    abstract:BACKGROUND:Solithromycin is a fourth-generation macrolide antibiotic with potential efficacy in pediatric community-acquired bacterial pneumonia. Pharmacokinetic (PK) studies of solithromycin in pediatric subjects are limited, therefore application of minimally invasive drug sampling techniques, such as dried blood spo...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/FTD.0000000000000670

    authors: Beechinor RJ,Cohen-Wolkowiez M,Jasion T,Hornik CP,Lang JE,Hernandez R,Gonzalez D

    更新日期:2019-12-01 00:00:00

  • Clinical implications of thiopurine methyltransferase--optimization of drug dosage and potential drug interactions.

    abstract::Thiopurine methyltransferase (TPMT) is a cytoplasmic enzyme that preferentially catalyzes the S-methylation of aromatic and heterocyclic sulphydryl compounds, such as the thiopurine drugs azathioprine, mercaptopurine, and thioguanine. These drugs form the same terminal metabolites, the thioguanine nucleotides (TGNs). ...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章,评审

    doi:10.1097/00007691-199810000-00014

    authors: Lennard L

    更新日期:1998-10-01 00:00:00

  • Therapeutic drug monitoring of infliximab in spondyloarthritis: an observational open-label study.

    abstract:BACKGROUND:Infliximab is a chimeric monoclonal antibody that binds to human tumor necrosis factor alpha and which is approved for refractory spondyloarthritis (SpA). Individual adjustment of infliximab dosage may help to improve the therapeutic response in SpA. We investigated whether a knowledge of infliximab serum co...

    journal_title:Therapeutic drug monitoring

    pub_type: 临床试验,杂志文章

    doi:10.1097/FTD.0b013e318224f83d

    authors: Méric JC,Mulleman D,Ducourau E,Lauféron F,Miow Lin DC,Watier H,Goupille P,Paintaud G

    更新日期:2011-08-01 00:00:00

  • Desmethylimipramine overdose: nonlinear kinetics in a slow hydroxylator.

    abstract::A case of desmethylimipramine (DMI) overdose is described. The analysis of DMI and its main metabolite, 2-hydroxydesmethylimipramine (2-OH-DMI), in plasma was performed by high performance liquid chromatography with fluorescence detection. Characterization of the elimination kinetics of DMI by using the SAAM 25 comput...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:

    authors: Spina E,Henthorn TK,Eleborg L,Nordin C,Säwe J

    更新日期:1985-01-01 00:00:00

  • Experience with cost-effective in-house reagents for the assay of carbamazepine in serum, using the Abbott TDx.

    abstract::The development of inexpensive in-house reagents for the assay of carbamazepine in serum, using a commercially available derivative and antiserum is described. They were adapted for use on the Abbott TDx as direct replacements for commercial reagents. Comparison with a high-performance liquid chromatography method is ...

    journal_title:Therapeutic drug monitoring

    pub_type: 杂志文章

    doi:10.1097/00007691-199306000-00006

    authors: Colbert DL,Turner GJ

    更新日期:1993-06-01 00:00:00