Major depressive disorder identification by referenced multiset canonical correlation analysis with clinical scores.

Abstract:

:A novel method based on multiset canonical correlation analysis (mCCA) and linear discriminant analysis (LDA) is presented to identify the major depressive disorder (MDD). The new method comprises two parts, namely, the mCCA-rreg and sparse LDA models. The mCCA-rreg model extends the classical canonical correlation model to calculate functional connections by restricting the references to a reference space and adding a spatial regularization term. The reference space is used to ensure that the model extracts important components first from several datasets simultaneously by decreasing the importance of the components in which we are uninterested. The spatial regularization term helps in avoiding the multicollinearity and overfitting problems under the low signal-to-noise ratio circumstance. The sparse LDA model extends the classical LDA model to extract a small subset of discriminative classification features by fusing clinical scores. In the real data experiment, we extract two functional connection modes from 45 subjects by the mCCA-rreg model. Then, we construct classifiers to identify the patients with MDD based on the connections selected by the sparse LDA model. The best accuracy is higher than 95%. The results show that the mCCA-rreg model can retrieve the important components characterized by a preassigned reference space and exclude the noise or components of no interest. The sparse LDA model can extract discriminative classification features related to clinical scores.

journal_name

Med Image Anal

journal_title

Medical image analysis

authors

Lin W,Lv D,Han Z,Dong J,Yang L

doi

10.1016/j.media.2019.101600

subject

Has Abstract

pub_date

2020-02-01 00:00:00

pages

101600

eissn

1361-8415

issn

1361-8423

pii

S1361-8415(18)30159-2

journal_volume

60

pub_type

杂志文章
  • Probe trajectory interpolation for 3D reconstruction of freehand ultrasound.

    abstract::Three-dimensional (3D) freehand ultrasound uses the acquisition of non-parallel B-scans localized in 3D by a tracking system (optic, mechanical or magnetic). Using the positions of the irregularly spaced B-scans, a regular 3D lattice volume can be reconstructed, to which conventional 3D computer vision algorithms (reg...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2007.05.002

    authors: Coupé P,Hellier P,Morandi X,Barillot C

    更新日期:2007-12-01 00:00:00

  • Multi-task exclusive relationship learning for alzheimer's disease progression prediction with longitudinal data.

    abstract::Alzheimer's disease (AD) is a neurodegenerative disorder characterized by progressive impairment of memory and other cognitive functions. Currently, many multi-task learning approaches have been proposed to predict the disease progression at the early stage using longitudinal data, with each task corresponding to a pa...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.01.007

    authors: Wang M,Zhang D,Shen D,Liu M

    更新日期:2019-04-01 00:00:00

  • Cardiac image modelling: Breadth and depth in heart disease.

    abstract::With the advent of large-scale imaging studies and big health data, and the corresponding growth in analytics, machine learning and computational image analysis methods, there are now exciting opportunities for deepening our understanding of the mechanisms and characteristics of heart disease. Two emerging fields are ...

    journal_title:Medical image analysis

    pub_type: 社论,评审

    doi:10.1016/j.media.2016.06.027

    authors: Suinesiaputra A,McCulloch AD,Nash MP,Pontre B,Young AA

    更新日期:2016-10-01 00:00:00

  • Image guidance in orthopaedics and traumatology: A historical perspective.

    abstract::In this note we summarize the history of computer aided surgery in orthopaedics and traumatology from the end of the nineteenth century to currently observable future trends. We concentrate on the two major components of such systems, pre-operative planning and intra-operative execution. The evolution of the necessary...

    journal_title:Medical image analysis

    pub_type: 社论

    doi:10.1016/j.media.2016.06.033

    authors: Székely G,Nolte LP

    更新日期:2016-10-01 00:00:00

  • Robust estimation of carotid artery wall motion using the elasticity-based state-space approach.

    abstract::The dynamics of the carotid artery wall has been recognized as a valuable indicator to evaluate the status of atherosclerotic disease in the preclinical stage. However, it is still a challenge to accurately measure this dynamics from ultrasound images. This paper aims at developing an elasticity-based state-space appr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.01.004

    authors: Gao Z,Xiong H,Liu X,Zhang H,Ghista D,Wu W,Li S

    更新日期:2017-04-01 00:00:00

  • Semi-supervised mp-MRI data synthesis with StitchLayer and auxiliary distance maximization.

    abstract::The availability of a large amount of annotated data is critical for many medical image analysis applications, in particular for those relying on deep learning methods which are known to be data-hungry. However, annotated medical data, especially multimodal data, is often scarce and costly to obtain. In this paper, we...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101565

    authors: Wang Z,Lin Y,Cheng KT,Yang X

    更新日期:2020-01-01 00:00:00

  • Improvement of fully automated airway segmentation on volumetric computed tomographic images using a 2.5 dimensional convolutional neural net.

    abstract::We propose a novel airway segmentation method in volumetric chest computed tomography (CT) and evaluate its performance on multiple datasets. The segmentation is performed voxel-by-voxel by a 2.5D convolutional neural net (2.5D CNN) trained in a supervised manner. To enhance the accuracy of the segmented airway tree, ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.10.006

    authors: Yun J,Park J,Yu D,Yi J,Lee M,Park HJ,Lee JG,Seo JB,Kim N

    更新日期:2019-01-01 00:00:00

  • Dual-core steered non-rigid registration for multi-modal images via bi-directional image synthesis.

    abstract::In prostate cancer radiotherapy, computed tomography (CT) is widely used for dose planning purposes. However, because CT has low soft tissue contrast, it makes manual contouring difficult for major pelvic organs. In contrast, magnetic resonance imaging (MRI) provides high soft tissue contrast, which makes it ideal for...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.05.004

    authors: Cao X,Yang J,Gao Y,Guo Y,Wu G,Shen D

    更新日期:2017-10-01 00:00:00

  • Towards model-based analysis of cardiac MR tagging data: relation between left ventricular shear strain and myofiber orientation.

    abstract::Many cardiac pathologies are reflected in abnormal myocardial deformation, accessible through magnetic resonance tagging (MRT). Interpretation of the MRT data is difficult, since the relation between pathology and deformation is not straightforward. Mathematical models of cardiac mechanics could be used to translate m...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2006.04.001

    authors: Ubbink SW,Bovendeerd PH,Delhaas T,Arts T,van de Vosse FN

    更新日期:2006-08-01 00:00:00

  • A comprehensive study of stent visualization enhancement in X-ray images by image processing means.

    abstract::In this work we propose a comprehensive study of Digital Stent Enhancement (DSE), from the analysis of the requirements to the validation of the proposed solution. First, we derive the stent visualization requirements in the context of the clinical application and workflow. Then, we propose a DSE algorithm combining a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.03.002

    authors: Bismuth V,Vaillant R,Funck F,Guillard N,Najman L

    更新日期:2011-08-01 00:00:00

  • Expert-validated estimation of diagnostic uncertainty for deep neural networks in diabetic retinopathy detection.

    abstract::Deep learning-based systems can achieve a diagnostic performance comparable to physicians in a variety of medical use cases including the diagnosis of diabetic retinopathy. To be useful in clinical practice, it is necessary to have well calibrated measures of the uncertainty with which these systems report their decis...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101724

    authors: Ayhan MS,Kühlewein L,Aliyeva G,Inhoffen W,Ziemssen F,Berens P

    更新日期:2020-08-01 00:00:00

  • Regularized siamese neural network for unsupervised outlier detection on brain multiparametric magnetic resonance imaging: Application to epilepsy lesion screening.

    abstract::In this study, we propose a novel anomaly detection model targeting subtle brain lesions in multiparametric MRI. To compensate for the lack of annotated data adequately sampling the heterogeneity of such pathologies, we cast this problem as an outlier detection problem and introduce a novel configuration of unsupervis...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101618

    authors: Alaverdyan Z,Jung J,Bouet R,Lartizien C

    更新日期:2020-02-01 00:00:00

  • Concurrent tumor segmentation and registration with uncertainty-based sparse non-uniform graphs.

    abstract::In this paper, we present a graph-based concurrent brain tumor segmentation and atlas to diseased patient registration framework. Both segmentation and registration problems are modeled using a unified pairwise discrete Markov Random Field model on a sparse grid superimposed to the image domain. Segmentation is addres...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.02.006

    authors: Parisot S,Wells W 3rd,Chemouny S,Duffau H,Paragios N

    更新日期:2014-05-01 00:00:00

  • SDAE-GAN: Enable high-dimensional pathological images in liver cancer survival prediction with a policy gradient based data augmentation method.

    abstract::High-dimensional pathological images produced by Immunohistochemistry (IHC) methods consist of many pathological indexes, which play critical roles in cancer treatment planning. However, these indexes currently cannot be utilized in survival prediction because joining them with patients' clinicopathological features (...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101640

    authors: Wu H,Gao R,Sheng YP,Chen B,Li S

    更新日期:2020-05-01 00:00:00

  • A novel cortical thickness estimation method based on volumetric Laplace-Beltrami operator and heat kernel.

    abstract::Cortical thickness estimation in magnetic resonance imaging (MRI) is an important technique for research on brain development and neurodegenerative diseases. This paper presents a heat kernel based cortical thickness estimation algorithm, which is driven by the graph spectrum and the heat kernel theory, to capture the...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.01.005

    authors: Wang G,Zhang X,Su Q,Shi J,Caselli RJ,Wang Y,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2015-05-01 00:00:00

  • A comparison of freehand three-dimensional ultrasound reconstruction techniques.

    abstract::Three-dimensional freehand ultrasound imaging produces a set of irregularly spaced B-scans, which are typically reconstructed on a regular grid for visualization and data analysis. Most standard reconstruction algorithms are designed to minimize computational requirements and do not exploit the underlying shape of the...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(99)80028-0

    authors: Rohling R,Gee A,Berman L

    更新日期:1999-12-01 00:00:00

  • Ultrasound-fluoroscopy registration for prostate brachytherapy dosimetry.

    abstract::Prostate brachytherapy is a treatment for prostate cancer using radioactive seeds that are permanently implanted in the prostate. The treatment success depends on adequate coverage of the target gland with a therapeutic dose, while sparing the surrounding tissue. Since seed implantation is performed under transrectal ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.06.001

    authors: Dehghan E,Lee J,Fallavollita P,Kuo N,Deguet A,Le Y,Clif Burdette E,Song DY,Prince JL,Fichtinger G

    更新日期:2012-10-01 00:00:00

  • Piecewise-diffeomorphic image registration: application to the motion estimation between 3D CT lung images with sliding conditions.

    abstract::In this paper, we propose a new strategy for modelling sliding conditions when registering 3D images in a piecewise-diffeomorphic framework. More specifically, our main contribution is the development of a mathematical formalism to perform Large Deformation Diffeomorphic Metric Mapping registration with sliding condit...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.10.001

    authors: Risser L,Vialard FX,Baluwala HY,Schnabel JA

    更新日期:2013-02-01 00:00:00

  • Joint optimization of segmentation and shape prior from level-set-based statistical shape model, and its application to the automated segmentation of abdominal organs.

    abstract::The goal of this study is to provide a theoretical framework for accurately optimizing the segmentation energy considering all of the possible shapes generated from the level-set-based statistical shape model (SSM). The proposed algorithm solves the well-known open problem, in which a shape prior may not be optimal in...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.11.003

    authors: Saito A,Nawano S,Shimizu A

    更新日期:2016-02-01 00:00:00

  • DT-MRI denoising and neuronal fiber tracking.

    abstract::Diffusion tensor imaging can provide the fundamental information required for viewing structural connectivity. However, robust and accurate acquisition and processing algorithms are needed to accurately map the nerve connectivity. In this paper, we present a novel algorithm for extracting and visualizing the fiber tra...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2003.12.001

    authors: McGraw T,Vemuri BC,Chen Y,Rao M,Mareci T

    更新日期:2004-06-01 00:00:00

  • Confhusius: a robust and fully automatic calibration method for 3D freehand ultrasound.

    abstract::This paper describes a new robust and fully automatic method for calibration of three-dimensional (3D) freehand ultrasound called Confhusius (CalibratiON for FreeHand UltraSound Imaging USage). 3D Freehand ultrasound consists in mounting a position sensor on a standard probe. The echographic B-scans can be localized i...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2004.06.021

    authors: Rousseau F,Hellier P,Barillot C

    更新日期:2005-02-01 00:00:00

  • Quantitative analysis of retinal OCT.

    abstract::Clinical acceptance of 3-D OCT retinal imaging brought rapid development of quantitative 3-D analysis of retinal layers, vasculature, retinal lesions as well as facilitated new research in retinal diseases. One of the cornerstones of many such analyses is segmentation and thickness quantification of retinal layers and...

    journal_title:Medical image analysis

    pub_type: 社论

    doi:10.1016/j.media.2016.06.001

    authors: Sonka M,Abràmoff MD

    更新日期:2016-10-01 00:00:00

  • Towards intelligent robust detection of anatomical structures in incomplete volumetric data.

    abstract::Robust and fast detection of anatomical structures represents an important component of medical image analysis technologies. Current solutions for anatomy detection are based on machine learning, and are generally driven by suboptimal and exhaustive search strategies. In particular, these techniques do not effectively...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.06.007

    authors: Ghesu FC,Georgescu B,Grbic S,Maier A,Hornegger J,Comaniciu D

    更新日期:2018-08-01 00:00:00

  • Groupwise registration with global-local graph shrinkage in atlas construction.

    abstract::Graph-based groupwise registration methods are widely used in atlas construction. Given a group of images, a graph is built whose nodes represent the images, and whose edges represent a geodesic path between two nodes. The distribution of images on an image manifold is explored through edge traversal in a graph. The f...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101711

    authors: Fu T,Yang J,Li Q,Ai D,Song H,Jiang Y,Wang Y,Frangi AF

    更新日期:2020-08-01 00:00:00

  • Self-similarity weighted mutual information: a new nonrigid image registration metric.

    abstract::Mutual information (MI) has been widely used as a similarity measure for rigid registration of multi-modal and uni-modal medical images. However, robust application of MI to deformable registration is challenging mainly because rich structural information, which are critical cues for successful deformable registration...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2013.12.003

    authors: Rivaz H,Karimaghaloo Z,Collins DL

    更新日期:2014-02-01 00:00:00

  • Involuntary eye motion correction in retinal optical coherence tomography: Hardware or software solution?

    abstract::In this paper, we review state-of-the-art techniques to correct eye motion artifacts in Optical Coherence Tomography (OCT) imaging. The methods for eye motion artifact reduction can be categorized into two major classes: (1) hardware-based techniques and (2) software-based techniques. In the first class, additional ha...

    journal_title:Medical image analysis

    pub_type: 杂志文章,评审

    doi:10.1016/j.media.2017.02.002

    authors: Baghaie A,Yu Z,D'Souza RM

    更新日期:2017-04-01 00:00:00

  • Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm.

    abstract::In this paper an automatic atlas-based segmentation algorithm for 4D cardiac MR images is proposed. The algorithm is based on the 4D extension of the expectation maximisation (EM) algorithm. The EM algorithm uses a 4D probabilistic cardiac atlas to estimate the initial model parameters and to integrate a priori inform...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2004.06.005

    authors: Lorenzo-Valdés M,Sanchez-Ortiz GI,Elkington AG,Mohiaddin RH,Rueckert D

    更新日期:2004-09-01 00:00:00

  • CATARACTS: Challenge on automatic tool annotation for cataRACT surgery.

    abstract::Surgical tool detection is attracting increasing attention from the medical image analysis community. The goal generally is not to precisely locate tools in images, but rather to indicate which tools are being used by the surgeon at each instant. The main motivation for annotating tool usage is to design efficient sol...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.11.008

    authors: Al Hajj H,Lamard M,Conze PH,Roychowdhury S,Hu X,Maršalkaitė G,Zisimopoulos O,Dedmari MA,Zhao F,Prellberg J,Sahu M,Galdran A,Araújo T,Vo DM,Panda C,Dahiya N,Kondo S,Bian Z,Vahdat A,Bialopetravičius J,Flouty E,Qiu

    更新日期:2019-02-01 00:00:00

  • Noise reduction in diffusion MRI using non-local self-similar information in joint x-q space.

    abstract::Diffusion MRI affords valuable insights into white matter microstructures, but suffers from low signal-to-noise ratio (SNR), especially at high diffusion weighting (i.e., b-value). To avoid time-intensive repeated acquisition, post-processing algorithms are often used to reduce noise. Among existing methods, non-local...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.01.006

    authors: Chen G,Wu Y,Shen D,Yap PT

    更新日期:2019-04-01 00:00:00

  • Nonlinear multiscale regularisation in MR elastography: Towards fine feature mapping.

    abstract::Fine-featured elastograms may provide additional information of radiological interest in the context of in vivo elastography. Here a new image processing pipeline called ESP (Elastography Software Pipeline) is developed to create Magnetic Resonance Elastography (MRE) maps of viscoelastic parameters (complex modulus ma...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2016.05.012

    authors: Barnhill E,Hollis L,Sack I,Braun J,Hoskins PR,Pankaj P,Brown C,van Beek EJR,Roberts N

    更新日期:2017-01-01 00:00:00