Subclinical Auditory Neural Deficits in Patients With Type 1 Diabetes Mellitus.

Abstract:

OBJECTIVES:Diabetes mellitus (DM) is associated with a variety of sensory complications. Very little attention has been given to auditory neuropathic complications in DM. The aim of this study was to determine whether type 1 DM (T1DM) affects neural coding of the rapid temporal fluctuations of sounds, and how any deficits may impact on behavioral performance. DESIGN:Participants were 30 young normal-hearing T1DM patients, and 30 age-, sex-, and audiogram-matched healthy controls. Measurements included electrophysiological measures of auditory nerve and brainstem function using the click-evoked auditory brainstem response, and of brainstem neural temporal coding using the sustained frequency-following response (FFR); behavioral tests of temporal coding (interaural phase difference discrimination and the frequency difference limen); tests of speech perception in noise; and self-report measures of auditory disability using the Speech, Spatial and Qualities of Hearing Scale. RESULTS:There were no significant differences between T1DM patients and controls in the auditory brainstem response. However, the T1DM group showed significantly reduced FFRs to both temporal envelope and temporal fine structure. The T1DM group also showed significantly higher interaural phase difference and frequency difference limen thresholds, worse speech-in-noise performance, as well as lower overall Speech, Spatial and Qualities scores than the control group. CONCLUSIONS:These findings suggest that T1DM is associated with degraded neural temporal coding in the brainstem in the absence of an elevation in audiometric threshold, and that the FFR may provide an early indicator of neural damage in T1DM, before any abnormalities can be identified using standard clinical tests. However, the relation between the neural deficits and the behavioral deficits is uncertain.

journal_name

Ear Hear

journal_title

Ear and hearing

authors

AlJasser A,Uus K,Prendergast G,Plack CJ

doi

10.1097/AUD.0000000000000781

subject

Has Abstract

pub_date

2020-05-01 00:00:00

pages

561-575

issue

3

eissn

0196-0202

issn

1538-4667

journal_volume

41

pub_type

杂志文章
  • Effects of channel-to-electrode mappings on speech reception with the ineraid cochlear implant.

    abstract:OBJECTIVE:Research was conducted to assess multichannel saliency with the Ineraid cochlear prosthesis. The goal was to determine whether tonotopically ordered stimulation benefits speech reception. DESIGN:In a single high-performing subject, changes in speech reception were studied during two dramatic alterations to t...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199510000-00002

    authors: Rabinowitz WM,Eddington DK

    更新日期:1995-10-01 00:00:00

  • Relationship Between Diet, Tinnitus, and Hearing Difficulties.

    abstract:OBJECTIVES:Diet may affect susceptibility of the inner ear to noise and age-related effects that lead to tinnitus and hearing loss. This study used complementary single nutrient and dietary pattern analysis based on statistical grouping of usual dietary intake in a cross-sectional analysis of tinnitus and hearing diffi...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000765

    authors: Dawes P,Cruickshanks KJ,Marsden A,Moore DR,Munro KJ

    更新日期:2020-03-01 00:00:00

  • Nonsense syllable test (NST) results and hearing loss.

    abstract::Errors on a nonsense syllable test (NST) were compared to pure-tone thresholds and ages of 109 subjects with normal or sensorineural hearing loss. A strong correlation was found between the number of NST errors and hearing loss at 2000 and 250 Hz. NST errors do not appear to be related to the age of subjects. Excellen...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198702000-00008

    authors: Butts FM,Ruth RR,Schoeny ZG

    更新日期:1987-02-01 00:00:00

  • Hearing aid patients in private practice and public health (Veterans Affairs) clinics: are they different?

    abstract:OBJECTIVE:In hearing aid research, it is commonplace to combine data across subjects whose hearing aids were provided in different service delivery models. There is reason to question whether these types of patients are always similar enough to justify this practice. To explore this matter, this investigation evaluated...

    journal_title:Ear and hearing

    pub_type: 杂志文章,多中心研究

    doi:10.1097/01.aud.0000188188.01311.0b

    authors: Cox RM,Alexander GC,Gray GA

    更新日期:2005-12-01 00:00:00

  • The efficiency of the single- versus multiple-stimulus auditory steady state responses in infants.

    abstract:OBJECTIVES:Multiple auditory steady state responses (ASSRs) will likely be included in the diagnostic test battery for estimating infant auditory thresholds in the near future; however, the effects of single- versus multiple-stimulus presentation in infants has never been investigated. In adults, there are no interacti...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0b013e3181ff352c

    authors: Hatton J,Stapells DR

    更新日期:2011-05-01 00:00:00

  • Psychophysical performance and Mandarin tone recognition in noise by cochlear implant users.

    abstract:OBJECTIVE:The present study was aimed to examine the relationship between psychophysical performance in temporal and spectral resolution and Mandarin tone recognition in noise by cochlear-implant (CI) listeners. DESIGN:Seventeen Nucleus-24 implant users, 10 postlingually deafened and 7 prelingually deafened, participa...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e318031512c

    authors: Wei C,Cao K,Jin X,Chen X,Zeng FG

    更新日期:2007-04-01 00:00:00

  • Single-channel versus bilateral multichannel cochlear implant results: a case report.

    abstract::Pre- and postoperative audiologic findings are compared in a patient who underwent three cochlear implant surgeries: an initial single-channel device in a recently deafened ear with no residual hearing, followed by a multichannel device in a congenitally deafened ear with a severe to profound loss, and subsequent expl...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199112000-00007

    authors: Pijl S

    更新日期:1991-12-01 00:00:00

  • Effects of the number of channels and speech-to-noise ratio on rate of connected discourse tracking through a simulated cochlear implant speech processor.

    abstract:OBJECTIVE:To investigate the effects of number of channels and speech-to-noise ratio on connected discourse tracking (CDT) through simulations of cochlear implant speech processing. Previous studies have used citation-form vowel and consonant materials or simple sentences. CDT rates were expected to be less likely to b...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200110000-00007

    authors: Faulkner A,Rosen S,Wilkinson L

    更新日期:2001-10-01 00:00:00

  • The influence of clicks versus short tone bursts on the vestibular evoked myogenic potentials.

    abstract:OBJECTIVE:Vestibular evoked myogenic potential (VEMP) has become a diagnostic tool to evaluate the integrity of sacculo-collic reflex. To obtain a more consistent VEMP response in normal-hearing subjects, we examine whether clicks or short tone bursts are more effective in eliciting VEMP responses. DESIGN:Prospective ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000069225.80220.CB

    authors: Cheng PW,Huang TW,Young YH

    更新日期:2003-06-01 00:00:00

  • Speech perception using maps based on neural response telemetry measures.

    abstract:OBJECTIVE:To determine how speech perception is affected for Nucleus cochlear implant users when their speech processor is programmed using neural response telemetry (NRT) measures rather than traditional behavioral estimates of threshold and maximum comfort level. DESIGN:Electrically evoked compound action potential ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200202001-00009

    authors: Seyle K,Brown CJ

    更新日期:2002-02-01 00:00:00

  • Objective calibration of bone conductors using otoacoustic emissions.

    abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199910000-00001

    authors: Purcell D,Kunov H,Cleghorn W

    更新日期:1999-10-01 00:00:00

  • The Middle Ear Muscle Reflex in Rat: Developing a Biomarker of Auditory Nerve Degeneration.

    abstract:OBJECTIVES:The long-term goal of this research is to determine whether the middle ear muscle reflex can be used to predict the number of healthy auditory nerve fibers in hearing-impaired ears. In this study, we develop a high-impedance source and an animal model of the middle ear muscle reflex and explore the influence...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000520

    authors: Chertoff ME,Martz A,Sakumura JT,Kamerer AM,Diaz F

    更新日期:2018-05-01 00:00:00

  • Features from normal and sensorineural listeners' nonsense syllable test errors.

    abstract::Identification errors for initial consonants of consonants-vowels-consonants-vowels from lists A and B of the Nonsense Syllable Test were analyzed for 10 normal-hearing and 8 sensorineural hearing-impaired listeners. The Nonsense Syllable Test stimuli were presented binaurally through earphones at 6 increasing sensati...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198105000-00006

    authors: Doyle KJ,Danhauer JL,Edgerton BJ

    更新日期:1981-05-01 00:00:00

  • Design and function: a physical and electrical description of the 3M House cochlear implant system.

    abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Fretz RJ,Fravel RP

    更新日期:1985-05-01 00:00:00

  • Deterioration of Speech Recognition Ability Over a Period of 5 Years in Adults Ages 18 to 70 Years: Results of the Dutch Online Speech-in-Noise Test.

    abstract:OBJECTIVES:The first aim of the present study was to determine the change in speech recognition in noise over a period of 5 years in participants ages 18 to 70 years at baseline. The second aim was to investigate whether age, gender, educational level, the level of initial speech recognition in noise, and reported chro...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000134

    authors: Stam M,Smits C,Twisk JW,Lemke U,Festen JM,Kramer SE

    更新日期:2015-05-01 00:00:00

  • Deaf children's processing of auditory, visual, and combined stimuli.

    abstract::One hundred eighty-four deaf children were presented auditory, visual (speechreading), and combined stimuli. Some subjects showed an enhancement of their processing abilities in the combined mode, some demonstrated no improvement, and others yielded reduced scores. A method of data analysis is proposed which could con...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-198005000-00003

    authors: Holmes DW,Groccia B,Johnson K,Green W

    更新日期:1980-05-01 00:00:00

  • On the Etiology of Listening Difficulties in Noise Despite Clinically Normal Audiograms.

    abstract::Many people with difficulties following conversations in noisy settings have "clinically normal" audiograms, that is, tone thresholds better than 20 dB HL from 0.1 to 8 kHz. This review summarizes the possible causes of such difficulties, and examines established as well as promising new psychoacoustic and electrophys...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0000000000000388

    authors: Pienkowski M

    更新日期:2017-03-01 00:00:00

  • Assessment of ear disorders using power reflectance.

    abstract::This article describes the effect of various pathologies on power reflectance (PR) and absorbance measured in human adults. The pathologies studied include those affecting the tympanic membrane, the middle-ear ossicles, the middle-ear cavity, the inner ear, and intracranial pressure. Interesting pathology-induced chan...

    journal_title:Ear and hearing

    pub_type: 杂志文章,评审

    doi:10.1097/AUD.0b013e31829c964d

    authors: Nakajima HH,Rosowski JJ,Shahnaz N,Voss SE

    更新日期:2013-07-01 00:00:00

  • Reversible sensorineural hearing loss in a stroke patient.

    abstract::A case is presented of a patient with lateral pontine stroke which resulted in a moderate unilateral sensorineural hearing loss. ABR, word recognition scores, acoustic reflexes, neurological evaluation, and CT scan were consistent with brain stem lesion. Recovery of hearing, including acoustic reflexes and word recogn...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:

    authors: Bales JD

    更新日期:1989-04-01 00:00:00

  • Evaluation of a localization training program for hearing impaired listeners.

    abstract:OBJECTIVE:To evaluate the effectiveness of a home-based and a laboratory-based localization training program. DESIGN:This study examined the effectiveness of a localization training program on improving the localization ability of 15 participants with a mild-to-moderately severe hearing loss. These participants had wo...

    journal_title:Ear and hearing

    pub_type: 临床试验,杂志文章

    doi:10.1097/AUD.0000000000000067

    authors: Kuk F,Keenan DM,Lau C,Crose B,Schumacher J

    更新日期:2014-11-01 00:00:00

  • Reinforced active middle ear implant fixation in incus vibroplasty.

    abstract:OBJECTIVES:The active middle ear implant Vibrant Soundbridge® was originally designed to treat mild-to-severe sensorineural hearing losses. The floating mass transducer (FMT) is crimped onto the long incus process. The procedure is termed incus vibroplasty to distinguish from other attachment sites or stimulus modi for...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000078

    authors: Mlynski R,Dalhoff E,Heyd A,Wildenstein D,Hagen R,Gummer AW,Schraven SP

    更新日期:2015-01-01 00:00:00

  • Longitudinal changes in word recognition by patients who use the Ineraid cochlear implant.

    abstract::The time course for reacquisition of spondee word recognition was examined for 27 patients who use the Ineraid cochlear implant. At 1 month postfitting, test scores ranged from 0 to 84% correct. The median score was 10% correct. At 22 to 28 months postfitting, the scores ranged from 0 to 100% correct. The median score...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-199012000-00008

    authors: Dorman MF,Dankowski K,McCandless G,Parkin JL,Smith L

    更新日期:1990-12-01 00:00:00

  • Distortion product otoacoustic emission response characteristics in older adults.

    abstract:OBJECTIVE:The primary purpose of this study was to determine the distortion product otoacoustic emission (DPOAE) and noise response characteristics in a large sample of older adults. Another purpose was to evaluate how specific absolute DPOAE levels or DPOAE/Noise ratios differentiated hearing status in these individua...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/01.AUD.0000051847.66944.2B

    authors: Torre P 3rd,Cruickshanks KJ,Nondahl DM,Wiley TL

    更新日期:2003-02-01 00:00:00

  • Hypercholesterolemia is correlated with an increased risk of idiopathic sudden sensorineural hearing loss: a historical prospective cohort study.

    abstract:OBJECTIVE:Despite the many studies on the associated risk of cardiovascular and cerebrovascular events in patients with hypercholesterolemia (HCh), an association between HCh and the development of idiopathic sudden sensorineural hearing loss (ISSNHL) has been examined in only a few case-control studies. We tested the ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3182a76637

    authors: Chang SL,Hsieh CC,Tseng KS,Weng SF,Lin YS

    更新日期:2014-03-01 00:00:00

  • Neurophysiological Differences in Emotional Processing by Cochlear Implant Users, Extending Beyond the Realm of Speech.

    abstract:OBJECTIVE:Cochlear implants (CIs) restore a sense of hearing in deaf individuals. However, they do not transmit the acoustic signal with sufficient fidelity, leading to difficulties in recognizing emotions in voice and in music. The study aimed to explore the neurophysiological bases of these limitations. DESIGN:Twent...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000701

    authors: Deroche MLD,Felezeu M,Paquette S,Zeitouni A,Lehmann A

    更新日期:2019-09-01 00:00:00

  • Auditory Discrimination of Lexical Stress Patterns in Hearing-Impaired Infants with Cochlear Implants Compared with Normal Hearing: Influence of Acoustic Cues and Listening Experience to the Ambient Language.

    abstract:OBJECTIVES:To assess discrimination of lexical stress pattern in infants with cochlear implant (CI) compared with infants with normal hearing (NH). While criteria for cochlear implantation have expanded to infants as young as 6 months, little is known regarding infants' processing of suprasegmental-prosodic cues which ...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000243

    authors: Segal O,Houston D,Kishon-Rabin L

    更新日期:2016-03-01 00:00:00

  • Cochlear implantation in children with auditory neuropathy spectrum disorder.

    abstract:OBJECTIVE:To report the patient's characteristics, preoperative audiological profiles, surgical outcomes, and postoperative performance for children with auditory neuropathy spectrum disorder (ANSD) who ultimately received cochlear implants (CIs). DESIGN:Prospective, longitudinal study of children with ANSD who receiv...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0b013e3181ce693b

    authors: Teagle HF,Roush PA,Woodard JS,Hatch DR,Zdanski CJ,Buss E,Buchman CA

    更新日期:2010-06-01 00:00:00

  • An investigation of the applicability of the inventory, satisfaction with amplification in daily life, at 2 weeks post hearing aid fitting.

    abstract:OBJECTIVE:To investigate the applicability of the self-report inventory, Satisfaction with Amplification in Daily Life (SADL), at 2 wk postfitting. DESIGN:The SADL was completed by two groups of hearing aid users, one fitted 2 wk before completion, the other at least 1 yr before. All SADLs were completed as a paper an...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/00003446-200108000-00008

    authors: McLeod B,Upfold L,Broadbent C

    更新日期:2001-08-01 00:00:00

  • Monothermal Caloric Screening to Improve Healthcare Value.

    abstract:OBJECTIVES:To evaluate whether monothermal caloric screening can reduce the number of caloric irrigations required in the vestibular testing battery while maintaining diagnostic accuracy. DESIGN:Prospective controlled cohort study. Three hundred and ninety patients referred for vestibular testing at this tertiary refe...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000262

    authors: Thatcher AL,Beckerman ML,Telian SA,King WM

    更新日期:2016-05-01 00:00:00

  • Conversational Interaction Is the Brain in Action: Implications for the Evaluation of Hearing and Hearing Interventions.

    abstract::Humans have evolved the unique capacity to efficiently communicate using the spoken word. Hearing plays a key role as a receiver in this process and dysfunction leads to difficulties in listening and communication. It is widely accepted that effective communication is not adequately captured with current behavioral sp...

    journal_title:Ear and hearing

    pub_type: 杂志文章

    doi:10.1097/AUD.0000000000000939

    authors: Carlile S,Keidser G

    更新日期:2020-11-01 00:00:00