The design and evaluation of a novel low-cost portable ventilator.

Abstract:

:Modern mechanical ventilator technologies broadly consist of digitally-controlled electronic devices and analogue systems driven by compressed gas sources. Drawbacks such as high cost, complex maintenance and the need for cumbersome sources of compressed driving gas hinder adoption in pre-hospital and low-resource environments. We describe the evaluation and testing of a simple, low-cost alternative ventilator that uses a novel pressure-sensing approach and control algorithm. This is designed to provide portable positive-pressure mechanical ventilation at a reduced cost, while autonomously monitoring patient condition and important safety parameters. A prototype ventilator was constructed and evaluated using an anaesthetic test-lung as a patient surrogate. Using a modifiable test-lung and digital pressure sensor, we investigated ventilation pressure waveform circuit leak detection, and compliance and resistance change detection. During intermittent positive-pressure ventilation to the test-lung, the prototype system showed acceptable pressure waveform parameters: all simulated circuit leaks ≥ 6 mm2 in size were detected; compliance changes were detected between 10 ml.cmH2 O-1 , 20 ml.cmH2 O-1 and 50 ml.cmH2 O-1 ; and resistance changes were detected across the available simulated range. These results show this prototype technology has the potential to provide safe emergency ventilation without the use of any complex digital sensors or software while its construction and design enables significant reductions in cost and complexity. The study suggests further work is now justified in progressing the technology to clinical trials.

journal_name

Anaesthesia

journal_title

Anaesthesia

authors

Darwood A,McCanny J,Kwasnicki R,Martin B,Jones P

doi

10.1111/anae.14726

subject

Has Abstract

pub_date

2019-11-01 00:00:00

pages

1406-1415

issue

11

eissn

0003-2409

issn

1365-2044

journal_volume

74

pub_type

杂志文章
  • Decreasing delays in urgent and expedited surgery in a university teaching hospital through audit and communication between peri-operative and surgical directorates.

    abstract::National Confidential Enquiry into Patient Outcome and Death guidelines for urgent surgery recommend a fully staffed emergency operating theatre and restriction of 'after-midnight' operating to immediate life-, limb- or organ-threatening conditions. Audit performed in our institution demonstrated significant decreases...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2008.05441.x

    authors: Cosgrove JF,Gaughan M,Snowden CP,Lees T

    更新日期:2008-06-01 00:00:00

  • A meta-analysis of the accuracy and precision of the ultrasonic cardiac output monitor (USCOM).

    abstract::The ultrasonic cardiac output monitor is a non-invasive, continuous-wave Doppler monitor that can be used to measure cardiac output. Its accuracy and precision in peri-operative and critical care has been assessed with varied results. We conducted a meta-analysis to calculate a pooled mean bias, precision and percenta...

    journal_title:Anaesthesia

    pub_type: 杂志文章,meta分析,评审

    doi:10.1111/j.1365-2044.2012.07311.x

    authors: Chong SW,Peyton PJ

    更新日期:2012-11-01 00:00:00

  • Systemic side-effects of extradural steroids.

    abstract::The use of extradural (epidural) steroids in the management of selected cases of lumbosciatic syndrome is well known. This paper reports the appearance of systemic side-effects in four cases after each had received an injection of 6-10 ml of methylprednisolone and 0.25% bupivacaine into the extradural space at the sit...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1980.tb03858.x

    authors: Knight CL,Burnell JC

    更新日期:1980-06-01 00:00:00

  • Environmental contamination during tracheal suction. A comparison of disposable conventional catheters with a multiple-use closed system device.

    abstract::The extent of airborne environmental bacterial contamination which occurs following tracheal suction has been investigated in patients undergoing intermittent positive pressure ventilation in the intensive therapy unit. Two methods of performing suction, one using a conventional open technique and one using a closed s...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1991.tb09858.x

    authors: Cobley M,Atkins M,Jones PL

    更新日期:1991-11-01 00:00:00

  • Effect of cricoid pressure on the incidence of nausea and vomiting in the immediate postoperative period.

    abstract::This study aimed to evaluate whether the application of cricoid pressure at the time of induction of anaesthesia was associated with a lesser incidence of postoperative nausea or vomiting in the immediate postoperative period compared with a group in which no cricoid pressure was applied, in patients undergoing day ca...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1046/j.1365-2044.2000.055002163.x

    authors: Khan FA,ul Haq A

    更新日期:2000-02-01 00:00:00

  • Impact of right-handedness on anaesthetic sensitivity, intra-operative awareness and postoperative mortality.

    abstract::Anatomical, neurological and behavioural research has suggested differences between the brains of right- and non-right-handed individuals, including differences in brain structure, electroencephalogram patterns, explicit memory and sleep architecture. Some studies have also found decreased longevity in left-handed ind...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.12676

    authors: Rao S,Huverserian AR,Ben Abdallah A,Lees K,Willingham MD,Burnside BA,Villafranca AJ,Glick DB,Jacobsohn E,Avidan MS

    更新日期:2014-08-01 00:00:00

  • Ketamine, midazolam and vecuronium infusion. Anaesthesia for Down's syndrome and congenital heart disease.

    abstract::A ketamine, midazolam and vecuronium infusion was used for total intravenous anesthesia in a patient with Down's syndrome, a ventricular septal defect and pulmonary hypertension. A mixture of ketamine 200 mg, midazolam 5 mg and vecuronium 12 mg in 50 ml of normal saline was infused at 0.5 ml/kg/hour. This simple techn...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1991.tb09356.x

    authors: Riley DP,McBride LJ

    更新日期:1991-02-01 00:00:00

  • Bibliometric analysis of original molecular biology research in anaesthesia.

    abstract::Molecular biology has expanded the horizons of anaesthesia during the last 20 years and has led to an increase of basic science articles that are published in the specialised anaesthetic journals or originate in anaesthetic institutions. We searched for and analysed the specific features, such as year of publication, ...

    journal_title:Anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1111/j.1365-2044.2004.03873.x

    authors: Schreiber K,Girard T,Kindler CH

    更新日期:2004-10-01 00:00:00

  • Evaluation of an insulated Tuohy needle system for the placement of interscalene brachial plexus catheters.

    abstract::Major shoulder surgery can be extremely painful. Interscalene brachial plexus catheters provide excellent postoperative analgesia but are technically difficult to place. A new insulated Tuohy needle system for plexus catheterisation is now available. This prospective study examined its ease of use and the postoperativ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1046/j.1365-2044.2003.03184.x

    authors: Denny NM,Barber N,Sildown DJ

    更新日期:2003-06-01 00:00:00

  • HLA-DR expression and differential trafficking of monocyte subsets following low to intermediate risk surgery.

    abstract::Reduced HLA-DR expression on monocytes has been suggested as a predictive marker of immunosuppression following very high risk surgery, but there are few reports in lower risk surgery. In 32 patients undergoing low to intermediate risk surgery, blood samples were analysed by flow cytometry for HLA-DR expression and nu...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.2009.06161.x

    authors: Handy JM,Scott AJ,Cross AM,Sinha P,O'Dea KP,Takata M

    更新日期:2010-01-01 00:00:00

  • Rapid sequence induction: a questionnaire survey of its routine conduct and continued management during a failed intubation.

    abstract::Two hundred and ten obstetric anaesthetists completed a questionnaire assessing how they would perform a rapid sequence induction of anaesthesia for a Caesarean section and their continued management during a failed tracheal intubation. The survey revealed considerable variation in the timing and application of cricoi...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1046/j.1365-2044.1999.00738.x

    authors: Thwaites AJ,Rice CP,Smith I

    更新日期:1999-04-01 00:00:00

  • Ketamine and the oculocardiac reflex. Dysrhythmia in pediatric strabismus surgery: the role of intravenous atropine.

    abstract::Fifty children in the age-group 1.75-10 years, admitted for cure of strabismus, were anaesthetised with intramuscular ketamine. Half the patients, at random, were given intravenous atropine, while anaesthetised, 5 minutes before operative interference. ECG recording of Lead 2 showed an oculacardiac dysthythmic respons...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1976.tb11740.x

    authors: Apivor D,Ravi PK

    更新日期:1976-01-01 00:00:00

  • Calculating the probability of random sampling for continuous variables in submitted or published randomised controlled trials.

    abstract::In a previous paper, one of the authors (JBC) used a chi-squared method to analyse the means (SD) of baseline variables, such as height or weight, from randomised controlled trials by Fujii et al., concluding that the probabilities that the reported distributions arose by chance were infinitesimally small. Subsequent ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.13126

    authors: Carlisle JB,Dexter F,Pandit JJ,Shafer SL,Yentis SM

    更新日期:2015-07-01 00:00:00

  • Optimisation of the organ donor and effects on transplanted organs: a narrative review on current practice and future directions.

    abstract::Mortality remains high for patients on the waiting list for organ transplantation. A marked imbalance between the number of available organs and recipients that need to be transplanted persists. Organs from deceased donors are often declined due to perceived and actual suboptimal quality. Adequate donor management off...

    journal_title:Anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1111/anae.15037

    authors: Bera KD,Shah A,English MR,Harvey D,Ploeg RJ

    更新日期:2020-09-01 00:00:00

  • The first anaesthetic in Central Africa.

    abstract::The Reverend Doctor Robert Laws (1851-1934) followed in the footsteps of David Livingstone to Central Africa. At the beginning of a long and distinguished career as a medical missionary in Christian service to the country that has since become the Republic of Malawi, he was a prime mover in the setting up of a mission...

    journal_title:Anaesthesia

    pub_type: 传,历史文章,杂志文章

    doi:10.1111/j.1365-2044.1985.tb10611.x

    authors: Conacher ID

    更新日期:1985-11-01 00:00:00

  • Pre-operative analgesia with rectal diclofenac and/or paracetamol in children undergoing inguinal hernia repair.

    abstract::Both rectal diclofenac and paracetamol are commonly used to treat acute postoperative pain in children but combining them to improve the quality of analgesia is controversial. This study aimed to detect whether the pre-operative combined administration of rectal diclofenac and paracetamol is superior to either drug al...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.2007.05248.x

    authors: Riad W,Moussa A

    更新日期:2007-12-01 00:00:00

  • Modified patient-controlled remifentanil bolus delivery regimen for labour pain*.

    abstract::To improve the analgesic efficiency and to simplify the administration of remifentanil for systemic analgesia in labour, we contrived a modified delivery regimen with a specific infusion profile and variable dosing and conducted a single-blind randomised crossover study to compare it with the previous 'classical' regi...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/anae.12038

    authors: Jost A,Ban B,Kamenik M

    更新日期:2013-03-01 00:00:00

  • Comparison of reversal with neostigmine of low-dose rocuronium vs. reversal with sugammadex of high-dose rocuronium for a short procedure.

    abstract::Some short procedures require deep neuromuscular blockade, which needs to be reversed at the end of the procedure. Forty-four patients undergoing elective laryngeal micro-surgery were randomly allocated into two groups: rocuronium 0.45 mg.kg-1 with neostigmine (50 μg.kg-1 with glycopyrrolate 10 μg.kg-1 ) reversal (mod...

    journal_title:Anaesthesia

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/anae.13894

    authors: Choi ES,Oh AY,Koo BW,Hwang JW,Han JW,Seo KS,Ahn SH,Jeong WJ

    更新日期:2017-10-01 00:00:00

  • Aspiration pneumonia and the laryngeal mask airway.

    abstract::A case of aspiration pneumonia is reported after the use of a laryngeal mask airway in a young woman undergoing an elective cholecystectomy. The case illustrates the hazards of regurgitation with the laryngeal mask airway and the need for further evaluation when used with controlled mechanical ventilation. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1990.tb14882.x

    authors: Griffin RM,Hatcher IS

    更新日期:1990-12-01 00:00:00

  • Improved PCO2 measurement in six standard blood gas analysers using a phosphate-buffered solution for gastric tonometry.

    abstract::The measurement of gastric intramucosal pH serves as a non-invasive technique for early detection of gastrointestinal ischaemia in critically ill patients. The method is based on the determination of the partial pressure of carbon dioxide in a 0.9% saline solution using a standard blood gas analyser. However, the use ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1995.tb06047.x

    authors: Knichwitz G,Mertes N,Kuhmann M

    更新日期:1995-06-01 00:00:00

  • Clinical features of neuroleptic malignant syndrome in basal ganglia disease. Spontaneous presentation in a patient with Hallervorden-Spatz disease in the absence of neuroleptic drugs.

    abstract::Hallervorden-Spatz disease is a rare autosomal recessive disorder in which dopaminergic deficiency in the substantia nigra and its nigrostriatal projection has been identified. It is characterised by a slow but progressive course culminating in death. This case report describes a 13-year-old male, with a clinical diag...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1993.tb07070.x

    authors: Hayashi K,Chihara E,Sawa T,Tanaka Y

    更新日期:1993-06-01 00:00:00

  • The accuracy of timed maximum local anaesthetic dose calculations with an electronic calculator, nomogram, and pen and paper.

    abstract::Forty anaesthetists calculated maximum permissible doses of eight local anaesthetic formulations for simulated patients three times with three methods: an electronic calculator; nomogram; and pen and paper. Correct dose calculations with the nomogram (85/120) were more frequent than with the calculator (71/120) or pen...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/anae.13810

    authors: Walker JD,Williams N,Williams DJ

    更新日期:2017-06-01 00:00:00

  • Spontaneous movement after injection of propofol.

    abstract::Spontaneous movement following injection of propofol at induction was studied in 303 patients. Two hundred patients were Caucasians and 103 were Asians. In a pilot study carried out prior to the main study, 26% of the Asians moved at induction as compared with 6% of the Caucasians. The patients were studied in relatio...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1996.tb07850.x

    authors: Chan A,Nickoll E,Thornton C,Doré C,Newton DE

    更新日期:1996-07-01 00:00:00

  • Oesophageal multipurpose monitoring probe.

    abstract::An oesophageal probe which incorporates facilities for pressure, temperature, electrocardiographic and stethoscopic monitoring is described. Actual and potential uses are outlined. ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1983.tb12259.x

    authors: Baker AB,McLeod C

    更新日期:1983-09-01 00:00:00

  • Spinal anaesthesia for outpatient surgery.

    abstract::In a prospective study of 51 young male outpatients given spinal anaesthesia through a 25-gauge needle, we found a 37.2% incidence of postdural puncture headache. In addition, 54.9% complained of backache after surgery. Occurrence of headache significantly prolonged the sick-leave from work. General anaesthesia would ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1985.tb10612.x

    authors: Flaatten H,Raeder J

    更新日期:1985-11-01 00:00:00

  • Airway management guidance for the endemic phase of COVID-19.

    abstract::It is now apparent that severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and coronavirus disease 2019 (COVID-19) will remain endemic for some time. Improved therapeutics and a vaccine may shorten this period, but both are far from certain. Plans must be put in place on the assumption that the virus and its...

    journal_title:Anaesthesia

    pub_type: 杂志文章,评审

    doi:10.1111/anae.15253

    authors: Cook TM,McGuire B,Mushambi M,Misra U,Carey C,Lucas N,O'Sullivan E,Harrop-Griffiths W

    更新日期:2021-02-01 00:00:00

  • Low pressure leakage in anaesthetic machines. Evaluation by positive and negative pressure tests.

    abstract::Positive and negative pressure tests for checking the low pressure section of 36 anaesthetic machines in order to detect gas leaks were prospectively compared. The low pressure section was checked by the soap bubble test as a 'gold standard'. The leakage rate was 86.1%. The sensitivity and specificity of the positive ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1996.tb07792.x

    authors: Somprakit P,Soontranan P

    更新日期:1996-05-01 00:00:00

  • Rectal premedication in children. Comparison of diazepam with a mixture of morphine, scopolamine and diazepam.

    abstract::Two hundred and eight healthy children who were to undergo minor elective surgery during halothane, nitrous oxide, oxygen anaesthesia were studied in a double blind investigation to evaluate the sedative and anticholinergic effects of two rectal premedications. Group I received diazepam 0.75 mg/kg rectally; Group II r...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1985.tb10549.x

    authors: Haagensen RE

    更新日期:1985-10-01 00:00:00

  • Can esmolol manage surgically-induced tachycardia? Bolus esmolol treatment of intra-operative tachycardia due to surgical stimulation.

    abstract::A double-blind, randomised study was conducted to examine the efficacy of a single bolus dose of esmolol in treating surgically-induced tachycardia. Anaesthetic technique was identical in all patients, and consisted of premedication with midazolam and glycopyrronium, induction with thiopentone followed by suxamethoniu...

    journal_title:Anaesthesia

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1111/j.1365-2044.1991.tb09414.x

    authors: Whirley-Diaz J,Gold MI,Helfman SM,deLisser EA

    更新日期:1991-03-01 00:00:00

  • Vecuronium--a variable dose technique.

    abstract::Vecuronium was administered to patients in doses of 100, 150, 200 and 250 micrograms/kg and the duration of action recorded by noting the time to recovery of the first twitch in a train-of-four to 10% of the control twitch. The recovery times ranged from a mean of 28.4 minutes (100 micrograms/kg) to 72.4 minutes (250 ...

    journal_title:Anaesthesia

    pub_type: 杂志文章

    doi:10.1111/j.1365-2044.1987.tb03000.x

    authors: Feldman SA,Liban JB