Magnetic resonance elastography of skeletal muscle deep tissue injury.

Abstract:

:The current state-of-the-art diagnosis method for deep tissue injury in muscle, a subcategory of pressure ulcers, is palpation. It is recognized that deep tissue injury is frequently preceded by altered biomechanical properties. A quantitative understanding of the changes in biomechanical properties preceding and during deep tissue injury development is therefore highly desired. In this paper we quantified the spatial-temporal changes in mechanical properties upon damage development and recovery in a rat model of deep tissue injury. Deep tissue injury was induced in nine rats by two hours of sustained deformation of the tibialis anterior muscle. Magnetic resonance elastography (MRE), T2 -weighted, and T2 -mapping measurements were performed before, directly after indentation, and at several timepoints during a 14-day follow-up. The results revealed a local hotspot of elevated shear modulus (from 3.30 ± 0.14 kPa before to 4.22 ± 0.90 kPa after) near the center of deformation at Day 0, whereas the T2 was elevated in a larger area. During recovery there was a clear difference in the time course of the shear modulus and T2 . Whereas T2 showed a gradual normalization towards baseline, the shear modulus dropped below baseline from Day 3 up to Day 10 (from 3.29 ± 0.07 kPa before to 2.68 ± 0.23 kPa at Day 10, P < 0.001), followed by a normalization at Day 14. In conclusion, we found an initial increase in shear modulus directly after two hours of damage-inducing deformation, which was followed by decreased shear modulus from Day 3 up to Day 10, and subsequent normalization. The lower shear modulus originates from the moderate to severe degeneration of the muscle. MRE stiffness values were affected in a smaller area as compared with T2 . Since T2 elevation is related to edema, distributing along the muscle fibers proximally and distally from the injury, we suggest that MRE is more specific than T2 for localization of the actual damaged area.

journal_name

NMR Biomed

journal_title

NMR in biomedicine

authors

Nelissen JL,Sinkus R,Nicolay K,Nederveen AJ,Oomens CWJ,Strijkers GJ

doi

10.1002/nbm.4087

subject

Has Abstract

pub_date

2019-06-01 00:00:00

pages

e4087

issue

6

eissn

0952-3480

issn

1099-1492

journal_volume

32

pub_type

杂志文章
  • Dynamic nuclear polarization polarizer for sterile use intent.

    abstract::A novel polarizer based on the dissolution-dynamic nuclear polarization (DNP) method has been designed, built and tested. The polarizer differs from those previously described by being designed with sterile use intent and being compatible with clinical use. The main features are: (1) an integral, disposable fluid path...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1682

    authors: Ardenkjaer-Larsen JH,Leach AM,Clarke N,Urbahn J,Anderson D,Skloss TW

    更新日期:2011-10-01 00:00:00

  • 31P MRS measurement of mitochondrial function in skeletal muscle: reliability, force-level sensitivity and relation to whole body maximal oxygen uptake.

    abstract::The reliability, relation to whole-body maximal oxygen uptake (VO(2max)), and force-level sensitivity of (31)P MRS markers of mitochondrial function were studied in 39 normal-weight women. Following 90 s isometric plantar-flexion exercises at 45, 70 and 100% of maximum voluntary contraction, skeletal muscle mitochondr...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(200002)13:1<14::aid-nbm605

    authors: Larson-Meyer DE,Newcomer BR,Hunter GR,Hetherington HP,Weinsier RL

    更新日期:2000-01-01 00:00:00

  • Short-TE localised 1H MRS of the human brain at 3 T: quantification of the metabolite signals using two approaches to account for macromolecular signal contributions.

    abstract::The goal of this study was to validate metabolite quantification at short TE, with particular focus on how to best account for the macromolecular signal contribution. A robust, short-TE PRESS protocol is presented, which allows reliable quantification, in vivo, of metabolite signals at 3 T in human brain. Water suppre...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1219

    authors: Gottschalk M,Lamalle L,Segebarth C

    更新日期:2008-06-01 00:00:00

  • Phosphorus MR spectroscopy in the treatment of human extremity sarcomas.

    abstract::The application of 31P MR spectroscopy in the characterization and treatment of malignant human extremity tumors is reviewed and placed in the perspective of results obtained in murine sarcomas. Despite the now widespread acquisition of gradient localized spectral maps, the low spatial resolution that can be achieved ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/(sici)1099-1492(1998110)11:7<341::aid-nbm5

    authors: Sijens PE

    更新日期:1998-11-01 00:00:00

  • Differences in metabolism of 5-fluorouracil and 5-fluorouridine and regulation by glucosamine in human colon cancer multicell tumor spheroids.

    abstract::Glucosamine (GlcN) modulates fluoropyrimidine metabolism and enhances cytotoxicity of 5-fluorouridine (FUrd), but not of 5-fluorouracil (FUra), in human tumor models. To elucidate the underlying metabolic differences between FUra and FUrd, by the use of 19F and 31P NMR spectroscopy we studied these drugs in multicell ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199905)12:3<157::aid-nbm55

    authors: Chen TB,Bajzer Z,Macura S,Vuk-Pavlovic S

    更新日期:1999-05-01 00:00:00

  • Carbohydrate metabolism of the rat C6 glioma. An in vivo 13C and in vitro 1H magnetic resonance spectroscopy study.

    abstract::Surface coil 13C nuclear magnetic resonance (NMR) spectroscopy was used to investigate the in vivo carbohydrate metabolism of rat C6 gliomas during and after infusion with [1-13C] glucose. In vivo 1H-decoupled 13C NMR spectra of the glioma following infusion with [1-13C]glucose revealed the direct production of [3-13C...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940010105

    authors: Ross BD,Higgins RJ,Boggan JE,Willis JA,Knittel B,Unger SW

    更新日期:1988-02-01 00:00:00

  • Absolute quantification of metabolites in breast cancer cell extracts by quantitative 2D (1) H INADEQUATE NMR.

    abstract::Metabolomic studies by NMR spectroscopy are increasingly employed for a variety of biomedical applications. A very standardized 1D proton NMR protocol is generally employed for data acquisition, associated with multivariate statistical tests. Even if targeted approaches have been proposed to quantify metabolites from ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1816

    authors: Martineau E,Tea I,Akoka S,Giraudeau P

    更新日期:2012-08-01 00:00:00

  • Clinical ultrashort echo time imaging of bone and other connective tissues.

    abstract::The background underpinning the clinical use of ultrashort echo time, SPRITE and other pulse sequences for imaging bone and other connective tissues with short T2 is reviewed. Features of the basic physics relevant to UTE imaging are described, including the consequences when the radiofrequency pulse duration is of th...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1100

    authors: Robson MD,Bydder GM

    更新日期:2006-11-01 00:00:00

  • Short-echo spectroscopic imaging combined with lactate editing in a single scan.

    abstract::A short-echo spectroscopic imaging sequence extended with a frequency-selective multiple-quantum- coherence technique (Sel-MQC) is presented. The method enables acquisition of a complete water-suppressed proton spectrum with a short echo time and filtering of the J-coupling metabolite, lactate, from co-resonant lipids...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1284

    authors: Melkus G,Mörchel P,Behr VC,Kotas M,Flentje M,Jakob PM

    更新日期:2008-11-01 00:00:00

  • Radio frequency coil technology for small-animal MRI.

    abstract::A review of the theory, technology, and use of radio frequency (RF) coils for small-animal MRI is presented. It includes a brief overview of MR signal-to-noise (S/N) analysis and discussions of the various coils commonly used in small-animal MR: surface coils, linear volume coils, birdcages, and their derivatives. The...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1149

    authors: Doty FD,Entzminger G,Kulkarni J,Pamarthy K,Staab JP

    更新日期:2007-05-01 00:00:00

  • BOLD-specific cerebral blood volume and blood flow changes during neuronal activation in humans.

    abstract::To understand and predict the blood-oxygenation level-dependent (BOLD) fMRI signal, an accurate knowledge of the relationship between cerebral blood flow (DeltaCBF) and volume (DeltaCBV) changes is critical. Currently, this relationship is widely assumed to be characterized by Grubb's power-law, derived from primate d...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1411

    authors: Chen JJ,Pike GB

    更新日期:2009-12-01 00:00:00

  • Estimating the ATP cost of force production in the human gastrocnemius/soleus muscle group using 31P MRS and 1H MRI.

    abstract::Net ATP production rates in exercising human muscle were calculated from 31P MRS kinetic data collected with 1-8 s time resolution. During the exercise, the muscle output was measured using a force transducer. Muscle output (force/unit volume) is then divided by the calculated net ATP used to estimate the ATP cost of ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940040404

    authors: Boska M

    更新日期:1991-08-01 00:00:00

  • The effect of off-resonance radiofrequency pulse saturation on fMRI contrast.

    abstract::This paper describes the use of off-resonance saturation to further manipulate the blood oxygenation level dependent (BOLD) contrast of fMRI. A customized narrow bandwidth radiofrequency pulse, applied with a range of frequency offsets prior to selection of each slice, was designed and incorporated into a gradient ech...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199706/08)10:4/5<208::aid-

    authors: Song AW,Wolff SD,Balaban RS,Jezzard P

    更新日期:1997-06-01 00:00:00

  • Clinical characteristics and biomarkers of breast cancer associated with choline concentration measured by 1H MRS.

    abstract::This study investigated the association between the total choline (tCho) concentration and the clinical characteristics and biomarker status of breast cancer. Sixty-two patients with breast cancer, 1.5  cm or larger in size on MR images, were studied. The tCho concentration was correlated with the MRI features, contra...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1595

    authors: Chen JH,Mehta RS,Baek HM,Nie K,Liu H,Lin MQ,Yu HJ,Nalcioglu O,Su MY

    更新日期:2011-04-01 00:00:00

  • An indirect method for in vivo T2 mapping of [1-13 C] pyruvate using hyperpolarized 13 C CSI.

    abstract::An indirect method for in vivo T2 mapping of 13 C-labeled metabolites using T2 and T2 * information of water protons obtained a priori is proposed. The T2 values of 13 C metabolites are inferred using the relationship to T2 ' of coexisting 1 H and the T2 * of 13 C metabolites, which is measured using routine hyperpola...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3690

    authors: Joe E,Lee H,Lee J,Yang S,Choi YS,Wang E,Song HT,Kim DH

    更新日期:2017-05-01 00:00:00

  • Measurement of tumor blood flow by deuterium NMR and the effects of modifiers.

    abstract::Tumor metabolism is directly coupled to tumor blood flow (TBF) and both metabolism and blood flow may be determinants of tumor response to treatment. Since NMR has been used extensively to monitor tumor metabolism noninvasively, development of NMR-based methods for TBF measurement was motivated by the desire to examin...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1940050516

    authors: Evelhoch JL

    更新日期:1992-09-01 00:00:00

  • Leakage of metabolites from tissue biopsies can result in large errors in quantitation by MRS.

    abstract::The leakage of metabolites from frozen and thawed tissue biopsies was measured semi-quantitatively by high-field (8.5 T) proton MRS. Human prostate and rat brain tissue specimens, frozen within 1 min of collection, lost significant and variable amounts of diagnostic metabolites immediately upon thawing. For prostate t...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.815

    authors: Bourne R,Dzendrowskyj T,Mountford C

    更新日期:2003-04-01 00:00:00

  • Detection of bioradicals by in vivo L-band electron spin resonance spectrometry.

    abstract::The applications of in vivo electron paramagnetic resonance (EPR) or electron spin resonance (ESR) spectroscopy have been impressive over a relatively short period despite the many obstacles which had to be overcome, such as dielectric absorption and biodestruction. The loop-gap resonators and modified loop coil syste...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.898

    authors: Fujii H,Berliner LJ

    更新日期:2004-08-01 00:00:00

  • Glucagon infusion alters the hyperpolarized 13 C-urea renal hemodynamic signature.

    abstract::Renal urea handling is central to the urine concentrating mechanism, and as such the ability to image urea transport in the kidney is an important potential imaging biomarker for renal functional assessment. Glucagon levels associated with changes in dietary protein intake have been shown to influence renal urea handl...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4028

    authors: Qi H,Mariager CØ,Nielsen PM,Schroeder M,Lindhardt J,Nørregaard R,Klein JD,Sands JM,Laustsen C

    更新日期:2019-01-01 00:00:00

  • Dynamic contrast-enhanced MRI model selection for predicting tumor aggressiveness in papillary thyroid cancers.

    abstract::The purpose of this study was to identify the optimal tracer kinetic model from T1 -weighted dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) data and evaluate whether parameters estimated from the optimal model predict tumor aggressiveness determined from histopathology in patients with papillary thyroi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4166

    authors: Paudyal R,Lu Y,Hatzoglou V,Moreira A,Stambuk HE,Oh JH,Cunanan KM,Aramburu Nunez D,Mazaheri Y,Gonen M,Ho A,Fagin JA,Wong RJ,Shaha A,Tuttle RM,Shukla-Dave A

    更新日期:2020-01-01 00:00:00

  • Quantitative MRI and ultrastructural examination of the cuprizone mouse model of demyelination.

    abstract::The cuprizone mouse model of demyelination was used to investigate the influence that white matter changes have on different magnetic resonance imaging results. In vivo T2 -weighted and magnetization transfer images (MTIs) were acquired weekly in control (n = 5) and cuprizone-fed (n = 5) mice, with significant increas...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2992

    authors: Thiessen JD,Zhang Y,Zhang H,Wang L,Buist R,Del Bigio MR,Kong J,Li XM,Martin M

    更新日期:2013-11-01 00:00:00

  • Transcranial direct current stimulation promotes the mobility of engrafted NSCs in the rat brain.

    abstract::Transcranial direct current stimulation (tDCS) is used in numerous clinical studies and considered an effective and versatile add-on therapy in neurorehabilitation. To date, however, the underlying neurobiological mechanisms remain elusive. In a rat model of tDCS, we recently observed a polarity-dependent accumulation...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3244

    authors: Keuters MH,Aswendt M,Tennstaedt A,Wiedermann D,Pikhovych A,Rotthues S,Fink GR,Schroeter M,Hoehn M,Rueger MA

    更新日期:2015-02-01 00:00:00

  • Signal-to-noise ratio of a mouse brain (13) C CryoProbe™ system in comparison with room temperature coils: spectroscopic phantom and in vivo results.

    abstract::MRI and MRS in small rodents demand very high sensitivity. Cryogenic transmit/receive radiofrequency probes (CryoProbes) designed for (1) H MRI of mouse brain provide an attractive option for increasing the performance of small-animal MR systems. As the Larmor frequency of (13) C nuclei is four times lower than that f...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3110

    authors: Sack M,Wetterling F,Sartorius A,Ende G,Weber-Fahr W

    更新日期:2014-06-01 00:00:00

  • Optimization of magnetization transfer experiments to measure first-order rate constants and spin-lattice relaxation times.

    abstract::A recent analysis of the optimization of magnetization transfer experiments to estimate first-order rate constants is extended to the design of experiments for measuring these constants and T1 when both parameters are initially unknown. When the number of measurement times is fixed, an optimal design will consist of a...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(SICI)1099-1492(199605)9:3<135::AID-NBM404

    authors: Katki H,Weiss GH,Kiefer JE,Taitelbaum H,Spencer RG

    更新日期:1996-05-01 00:00:00

  • Quantification of cerebral edema on diffusion tensor imaging in acute-on-chronic liver failure.

    abstract::Cerebral edema is a major complication of acute liver failure but may also be seen in other forms of liver failure such as acute-on-chronic liver failure (ACLF) and chronic liver failure (CLF). ACLF develops in patients with previously well-compensated chronic liver disease following acute hepatitis A or E superimpose...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1249

    authors: Nath K,Saraswat VA,Krishna YR,Thomas MA,Rathore RK,Pandey CM,Gupta RK

    更新日期:2008-08-01 00:00:00

  • High-resolution proton nuclear magnetic resonance spectroscopy of ovarian cyst fluid.

    abstract::Most ovarian tumors are cystic structures containing variable amounts of fluid. Several studies of ovarian cyst fluid focus on one specific metabolite using conventional assay systems. We examined the potential of (1)H-nuclear magnetic resonance spectroscopy in evaluation of the overall metabolic composition of cyst f...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/1099-1492(200008)13:5<297::aid-nbm648>3.0.

    authors: Boss EA,Moolenaar SH,Massuger LF,Boonstra H,Engelke UF,de Jong JG,Wevers RA

    更新日期:2000-08-01 00:00:00

  • Pharmacological FMRI in the development of new analgesic compounds.

    abstract::Chronic pain is a major problem for the individual and for society. Despite a range of drugs being available to treat chronic pain, only inadequate pain relief can be achieved for many patients. There is therefore a need for the development of new analgesic compounds. The assessment of pain depends to date entirely on...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1076

    authors: Schweinhardt P,Bountra C,Tracey I

    更新日期:2006-10-01 00:00:00

  • In vivo detection of d-amino acid oxidase with hyperpolarized d-[1-13 C]alanine.

    abstract::d-amino acid oxidase (DAO) is a peroxisomal enzyme that catalyzes the oxidative deamination of several neutral and basic d-amino acids to their corresponding α-keto acids. In most mammalian species studied, high DAO activity is found in the kidney, liver, brain and polymorphonuclear leukocytes, and its main function i...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4303

    authors: Radaelli A,Gruetter R,Yoshihara HAI

    更新日期:2020-07-01 00:00:00

  • Metabolic changes associated with vacuolation in murine models of scrapie using in vitro 1H-NMR spectroscopy.

    abstract::In this study, metabolic changes in the 79A/C3H, ME7/VM, ME7/C3H, 87V/VM and 22A/SV scrapie mouse models were investigated during the clinical phase of the disease, using in vitro proton nuclear magnetic resonance spectroscopy. N-acetyl-aspartate was found to be significantly reduced in infected mice of the ME7/ C3H (...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(SICI)1099-1492(199612)9:8<359::AID-NBM428

    authors: Chung YL,Williams A,Chong A,Hope J,Williams SC,Bell JD

    更新日期:1996-12-01 00:00:00

  • Feasibility and reproducibility of neurochemical profile quantification in the human hippocampus at 3 T.

    abstract::Hippocampal dysfunction is known to be associated with several neurological and neuropsychiatric disorders such as Alzheimer's disease, epilepsy, schizophrenia and depression; therefore, there has been significant clinical interest in studying hippocampal neurochemistry. However, the hippocampus is a challenging regio...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3309

    authors: Bednařík P,Moheet A,Deelchand DK,Emir UE,Eberly LE,Bareš M,Seaquist ER,Öz G

    更新日期:2015-06-01 00:00:00