Abstract:
PURPOSE:To investigate tight-frame based iterative reconstruction (TFIR) technique for spectral breast computed tomography (CT) using fewer projections while achieving greater image quality. METHODS:The experimental data were acquired with a fan-beam breast CT system based on a cadmium zinc telluride photon-counting detector. The images were reconstructed with a varying number of projections using the TFIR and filtered backprojection (FBP) techniques. The image quality between these two techniques was evaluated. The image's spatial resolution was evaluated using a high-resolution phantom, and the contrast to noise ratio (CNR) was evaluated using a postmortem breast sample. The postmortem breast samples were decomposed into water, lipid, and protein contents based on images reconstructed from TFIR with 204 projections and FBP with 614 projections. The volumetric fractions of water, lipid, and protein from the image-based measurements in both TFIR and FBP were compared to the chemical analysis. RESULTS:The spatial resolution and CNR were comparable for the images reconstructed by TFIR with 204 projections and FBP with 614 projections. Both reconstruction techniques provided accurate quantification of water, lipid, and protein composition of the breast tissue when compared with data from the reference standard chemical analysis. CONCLUSIONS:Accurate breast tissue decomposition can be done with three fold fewer projection images by the TFIR technique without any reduction in image spatial resolution and CNR. This can result in a two-third reduction of the patient dose in a multislit and multislice spiral CT system in addition to the reduced scanning time in this system.
journal_name
Med Physjournal_title
Medical physicsauthors
Zhao B,Gao H,Ding H,Molloi Sdoi
10.1118/1.4790468subject
Has Abstractpub_date
2013-03-01 00:00:00pages
031905issue
3eissn
0094-2405issn
2473-4209journal_volume
40pub_type
杂志文章相关文献
MEDICAL PHYSICS文献大全abstract::In patients with lymphoma, identification and quantification of the tumor extent on serial CT examinations is critical for assessing tumor response to therapy. In this paper, we present a computer method to automatically match and segment lymphomas in follow-up CT images. The method requires that target lymph nodes in...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2404617
更新日期:2007-01-01 00:00:00
abstract::By design, the range of beam directions in conventional radiosurgery are constrained to an isocentric array. However, the recent introduction of robotic radiosurgery dramatically increases the flexibility of targeting, and as a consequence, beams need be neither coplanar nor isocentric. Such a nonisocentric design per...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2357020
更新日期:2006-11-01 00:00:00
abstract::Volumetric modulated arc therapy (VMAT) has recently been used to improve the dose distribution and efficiency of treatment delivery over the standard intensity-modulated radiotherapy (IMRT) technique. This study compares the dosimetry between RapidArc plan and standard IMRT plan for head and neck cancer. Three head a...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4740174
更新日期:2012-07-01 00:00:00
abstract::An important aspect of heavy charged particle radiotherapy is its ability to localize dose to the target volume. Current techniques generally employ beam delivery schemes which use range modulated beams in which the Bragg peak is spread out over a range of depths. The range modulation is constant over the entire beam ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595419
更新日期:1983-11-01 00:00:00
abstract::Weighting of given doses from parallel opposed fields is a widespread practice in radiation therapy of cancer in the tonsillar region. In order to determine when weighting is useful, dose distributions on the central axis were calculated for various energies (60Co, 4-, 8-, 15-, and MVp photons), weighting factors, and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594276
更新日期:1976-03-01 00:00:00
abstract:PURPOSE:The purpose of this study was to provide updated radiation dose from diagnostic exams performed for pregnant patients suspected of pulmonary embolism (PE) using the recently developed BREP phantoms of pregnant woman and the fetus. Also to challenge the validity of current recommendations suggest that ventilatio...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12558
更新日期:2017-11-01 00:00:00
abstract::The objective of this study was to compare the contrast-detail performance of five different commercial liquid crystal displays (LCDs) to other LCD and cathode-ray tube (CRT) displays for medical applications. A contrast-detail phantom, supplemented with 5 in. of acrylic, was imaged on a commercial digital radiographi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2868780
更新日期:2008-04-01 00:00:00
abstract::A commercial optical system developed by Solid Photography, Inc., has been used to generate precise paraffin--polyethylene tissue compensators. A program with the objective of constructing a medical facility has been undertaken to access patient topology for treatment planning, tissue-compensator fabrication, and pati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.594447
更新日期:1978-11-01 00:00:00
abstract:PURPOSE:Phase contrast imaging, particularly of the breast, is being actively investigated. The purpose of this work is to investigate the x-ray phase contrast properties of breast tissues and commonly used breast tissue substitutes or phantom materials with an aim of determining the phantom materials best representati...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4794503
更新日期:2013-04-01 00:00:00
abstract::A new scheme, called direct aperture deformation (DAD), for online correction of interfraction geometric uncertainties under volumetric imaging guidance is presented. Using deformable image registration, the three-dimensional geometric transformation matrix can be derived that associates the planning image set and the...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.2374675
更新日期:2006-12-01 00:00:00
abstract::When a beam-modifying filter such as a wedge or a compensator is placed in an x-ray beam, scattered photons are generated in the filter material. The magnitude of the dose contribution from these photons for a 4-MV x-ray beam was measured. At a distance of 30 cm from the filter, a copper sheet of 1-cm thickness produc...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.595923
更新日期:1986-01-01 00:00:00
abstract:PURPOSE:To characterize the modulation transfer function (MTF) of proton/carbon radiography using Monte Carlo simulations. To assess the spatial resolution of proton/carbon radiographic imaging. METHODS:A phantom was specifically modeled with inserts composed of two materials with three different densities of bone and...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4819816
更新日期:2013-09-01 00:00:00
abstract::The feasibility of using film dosimetry data as the input data for patient treatment planning was evaluated. The central-axis depth dose and the off-axis ratios obtained from film measurements in a solid phantom were compared with those of ion-chamber measurements in water. Two techniques were used to generate isodose...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596409
更新日期:1989-11-01 00:00:00
abstract::For obliquely incident photon beams, the buildup of dose with depth is markedly different from normally incident beams. However, relatively little data on this topic exists for high-energy photon beams of energy greater than 6 MV. Measurements of dose in the buildup region were made using a plane-parallel ionization c...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596055
更新日期:1987-05-01 00:00:00
abstract:PURPOSE:To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS:Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patt...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3646756
更新日期:2011-11-01 00:00:00
abstract:PURPOSE:Diabetic retinopathy (DR) is one of the most widespread causes of preventable blindness in the world. The most dangerous stage of this condition is proliferative DR (PDR), in which the risk of vision loss is high and treatments are less effective. Fractal features of the retinal vasculature have been previously...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12627
更新日期:2017-12-01 00:00:00
abstract::Positron emission tomography (PET) is increasingly considered as an effective imaging method to support several stages of radiation therapy. The combined usage of functional and morphological imaging in state-of-the-art PET/CT scanners is rapidly emerging to support the treatment planning process in terms of improved ...
journal_title:Medical physics
pub_type: 杂志文章,评审
doi:10.1118/1.4935869
更新日期:2015-12-01 00:00:00
abstract:PURPOSE:To provide a fast computational method, based on the proximal graph solver (POGS) - A convex optimization solver using the alternating direction method of multipliers (ADMM), for calculating an optimal treatment plan in rotating shield brachytherapy (RSBT). RSBT treatment planning has more degrees of freedom th...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.12486
更新日期:2017-10-01 00:00:00
abstract:PURPOSE:Normal patient databases (NPDs) are used to distinguish between normal and abnormal perfusion in SPECT myocardial perfusion imaging (MPI) and have gained wide acceptance in the clinical environment, yet there are limitations to this approach. This study introduces a template-based method for semi-quantitative M...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3595112
更新日期:2011-07-01 00:00:00
abstract:PURPOSE:In MRI-guided needle interventions, such as biopsies and brachytherapy, tissue deformation caused by needle movement may result in localization errors and thus hamper the outcome of the procedure. Monitoring the local tissue deformation provides the ability to compensate for it, e.g., by increasing the needle i...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3633906
更新日期:2011-10-01 00:00:00
abstract:PURPOSE:To evaluate the availability and performance of pencil beam algorithm for fast neutrons radiotherapy dose calculations and to achieve improvements in universality, speed and inhomogeneities corrections. METHODS:Pencil beam (PB) method uses integration of dose kernel cross field size to estimate dose distributi...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4735630
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:Quantitative SPECT imaging is limited by many factors, including penetration of high energy photons through the collimator. Even small peaks of high energy yield extensive contamination in the photopeak energy window. Rotating slat collimators typically offer a 40- to 50-fold increase in geometric detection eff...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3177312
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:Stereotactic body radiation therapy (SBRT) is a radiotherapy technique which uses high dose fractions with multiple coplanar and noncoplanar beams. Due to the large fractional doses, treatments are typically protracted and there are more fields than in conventional radiation treatment schemes. The effect of tem...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4709605
更新日期:2012-06-01 00:00:00
abstract:PURPOSE:To propose a method to calculate the tissue phantom ratio (TPR) using the depth dose and to compare the proposed method with two other methods. METHODS:An analytical dose model from Bjärngard was used to describe the depth dose and the TPR. The parameters of the model were derived from depth dose measurements,...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3570575
更新日期:2011-05-01 00:00:00
abstract::The purpose of this study was to quantify in-stent restenoses with 3D B mode and power Doppler ultrasound (U.S.) imaging. In-stent restenoses were mimicked with vascular phantoms in which a nonferromagnetic prototype stent (Boston Scientific) and a ferromagnetic clinical stainless steel stent (Palmaz P295) were embedd...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3062944
更新日期:2009-02-01 00:00:00
abstract:PURPOSE:To develop a pharmacokinetic modelfree framework to analyze the dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) data for assessment of response of brain metastases to radiation therapy. METHODS:Twenty patients with 45 analyzable brain metastases had MRI scans prior to whole brain radiation thera...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4842556
更新日期:2014-01-01 00:00:00
abstract:PURPOSE:The purpose of this study was to investigate the potential of MR-guided pulsed focused ultrasound (pFUS) for the enhancement of drug uptake in prostate tumors in vivo using doxorubicin (Dox). METHODS:An antitumor drug Dox, an orthotopic animal prostate tumor model using human prostate cancer, LNCaP cell line, ...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.4705346
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:Respiratory motion in the chest region during single photon emission computed tomography (SPECT) is a major degrading factor that reduces the accuracy of image quantification. This effect is more notable when the tumor is very small, or the spatial resolution of the imaging system is less than the respiratory m...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1002/mp.13807
更新日期:2019-11-01 00:00:00
abstract:PURPOSE:The purpose of this study was to characterize the Hounsfield unit (HU) distributions of mesothelioma and other tissues present in contrast-enhanced thoracic CT scans, to compare the HU distributions of mesothelioma, muscle, and liver by scanner and reconstruction filter/kernel combination, and to assess interpa...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.3537610
更新日期:2011-02-01 00:00:00
abstract::Transmission imaging is receiving increasing attention in SPECT due to the need to compensate for nonuniform attenuation in cardiac-chest SPECT. The quality of a transmission image has an important effect on the measured attenuation distribution. To improve image quality, knowledge of the performance characteristics o...
journal_title:Medical physics
pub_type: 杂志文章
doi:10.1118/1.596752
更新日期:1992-09-01 00:00:00