Abstract:
:The authors adapted the transport system of a computed tomographic (CT) scanner with continuous rotation capability to examine complete lung subvolumes during a single breath hold. Twenty-four adult patients underwent scanning with up to 12 continuous 1-second rotations, and data acquisition was synchronized with longitudinal patient motion at one section thickness per second. Interpolated planar raw data were obtained retrospectively from any level within the volume, and these afforded high-quality images that were comparable to standard images. Solitary pulmonary nodules were not omitted, their centers could always be depicted, and secondary reformations as well as three-dimensional reconstructions were obtained easily. The authors conclude that spiral volumetric CT, by completely surveying a subvolume of the lung, is an attractive new application of CT.
journal_name
Radiologyjournal_title
Radiologyauthors
Vock P,Soucek M,Daepp M,Kalender WAdoi
10.1148/radiology.176.3.2389050subject
Has Abstractpub_date
1990-09-01 00:00:00pages
864-7issue
3eissn
0033-8419issn
1527-1315journal_volume
176pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:To assess feasibility and reliability of electrocardiographic (ECG)-gated cardiac magnetic resonance (MR) imaging with a simplified reusable electrode design that does not touch the skin. MATERIALS AND METHODS:In this institutional review board-approved, HIPAA-compliant study, a silicon positioner held four EC...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015142318
更新日期:2016-02-01 00:00:00
abstract::The incidental radiation dose of lithium fluoride thermoluminescence dosimeters was recorded during 15 treatments of patients with auricular keloids. Two half-value layers were used, and the results were compared. In both instances, the homolateral lens and thyroid received twice the contralateral dose. The oropharynx...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.144.3.7100490
更新日期:1982-08-01 00:00:00
abstract:PURPOSE:To evaluate selective embolization for management of posttraumatic priapism in preadolescent boys and color Doppler sonography for diagnosis of the causative lesion and for planning embolization. MATERIALS AND METHODS:Five preadolescent boys with posttraumatic priapism underwent selective angiography and embol...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.1.7784590
更新日期:1995-07-01 00:00:00
abstract::The sonograms of 40 patients with second-trimester polyhydramnios were reviewed to determine (a) whether fetal and maternal conditions occur as often during second-trimester polyhydramnios as during third-trimester polyhydramnios, (b) the frequency of persistence of polyhydramnios into the third trimester, and (c) how...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.2.3310100
更新日期:1987-11-01 00:00:00
abstract:PURPOSE:To prospectively determine in swine the effects of cardiac-specific and hypoxia-inducible vascular endothelial growth factor (VEGF) expression gene on angiogenesis and arteriogenesis by using cardiovascular magnetic resonance (MR) imaging for evaluation of infarct resorption and left ventricular (LV) function. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2432060928
更新日期:2007-05-01 00:00:00
abstract::In an effort to minimize distortion and artifacts on magnetic resonance images obtained with electrocardiographic (ECG) gating, the authors tested the use of ECG electrodes and leads made of carbon fiber. These materials caused no image degradation and, because the leads were reinforced with plastic, were less vulnera...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.171.3.2717770
更新日期:1989-06-01 00:00:00
abstract::A system for computerized processing of video image series was utilized for the real-time digitization of arteriograms. There were 256 x 256 picture elements (pixels) per image with a resolution of 256 gray levels. Temporal changes in x-ray absorption at each pixel as induced by contrast media were computed for the ex...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.141.1.7291540
更新日期:1981-10-01 00:00:00
abstract:PURPOSE:To assess the accuracy of glomerular filtration rate (GFR) measurements obtained with low-contrast agent dose dynamic contrast material-enhanced magnetic resonance (MR) renography in patients with liver cirrhosis who underwent routine liver MR imaging, with urinary clearance of technetium 99m ((99m)Tc) pentetic...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11101338
更新日期:2011-05-01 00:00:00
abstract::Fifty-eight patients with focal mass lesions involving the gastrointestinal tract were studied retrospectively. The diagnostic value of CT scans was seen by assessing the barium studies alone, then by combined review of radiographs and CT scans. Patient management decision making was similarly evaluated. CT scanning a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.158.3.3753800
更新日期:1986-03-01 00:00:00
abstract:PURPOSE:To detect regional metabolic differences in amyotrophic lateral sclerosis (ALS) with whole-brain echo-planar spectroscopic imaging. MATERIALS AND METHODS:Sixteen patients with ALS (nine men, seven women; mean age, 56.6 years), five persons suspected of having ALS (four men, one woman; mean age, 62.6 years), an...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13121148
更新日期:2013-06-01 00:00:00
abstract:PURPOSE:To determine the enhancement patterns of the penis at magnetic resonance (MR) imaging. MATERIALS AND METHODS:Sequential contrast material-enhanced MR images of the penis in a flaccid state were obtained in 16 volunteers (12 with normal penile function and four with erectile dysfunction). RESULTS:Subjects with...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.191.1.8134600
更新日期:1994-04-01 00:00:00
abstract::Twelve patients with symptoms of acute cholecystitis underwent heavily T2-weighted and mangafodipir trisodium-enhanced T1-weighted magnetic resonance (MR) cholangiography and cholescintigraphy before they underwent cholecystectomy. On T2-weighted MR cholangiographic images, morphologic evidence of outflow obstruction ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2272020207
更新日期:2003-05-01 00:00:00
abstract::History A 53-year-old man experienced headache and double vision that progressed over 1 year. After a traumatic fall, he was hospitalized, and proptosis was identified at physical examination. Laboratory tests were remarkable for leukocytosis. Hematocrit level, thyroid stimulating hormone level, autoimmune antibody le...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017141151
更新日期:2017-09-01 00:00:00
abstract::Forty computed tomography (CT)-assisted aspirations performed with only hand guidance were prospectively compared with 40 performed with a CT body-stereotaxic system. Although there was no statistically significant difference in lesion size and path length between the two groups, use of stereotaxis compared with hand ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.166.2.3275980
更新日期:1988-02-01 00:00:00
abstract:PURPOSE:To determine the utility of computed tomographic (CT) enteroclysis for characterization of the status of the anastomotic site in patients with Crohn disease who had previously undergone ileocolic resection. MATERIALS AND METHODS:Written informed consent was prospectively obtained from all patients, and the ins...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.09091165
更新日期:2010-03-01 00:00:00
abstract::The National Electrical Manufacturers Association (NEMA) has established a new standard for x-ray tube focal-spot measurements using a focal-spot camera with a slit instead of a pinhole. Measurements from the slit focal-spot camera are compared and star resolution pattern techniques for 50 focal spots. In addition, me...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.165.1.3628780
更新日期:1987-10-01 00:00:00
abstract:PURPOSE:To retrospectively compare the sensitivity of a computer-aided detection (CAD) system for depicting breast cancer in three digital mammographic views. MATERIALS AND METHODS:This study was conducted with institutional review board approval; informed consent was waived. A commercially available CAD system was ap...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051145
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:To prospectively assess which phase of a triple-phase dynamic contrast material-enhanced multi-detector row computed tomography (CT) protocol is optimal for visualization of esophageal cancer. MATERIALS AND METHODS:The study was supported by the local ethical committee; all patients gave written informed conse...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2393050222
更新日期:2006-06-01 00:00:00
abstract:PURPOSE:To quantify tumor perfusion after transcatheter arterial embolization (TAE) with functional computed tomography (CT) and to validate the reproducibility of quantification measurements. MATERIALS AND METHODS:This study was conducted in accordance with an institutional animal care and use committee-approved prot...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2371040526
更新日期:2005-10-01 00:00:00
abstract::Two cases demonstrated that intravenously injected contrast medium entered cystic lesions. It appears that both vascular opacification and transgression of the blood-brain barrier play major roles in contrast enhancement. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.2.345
更新日期:1976-08-01 00:00:00
abstract::We attempted to use hand-held, high-resolution breast sonography to localize for biopsy 11 solid, nonpalpable lesions detected by mammography. Using sonography, we identified and localized only one of four lesions presenting as poorly defined masses and only one of seven lesions presenting as clusters of tiny calcific...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.3890010
更新日期:1985-06-01 00:00:00
abstract:PURPOSE:To examine trabecular microarchitecture with high-resolution flat-panel volume computed tomography (CT) and bone mineral density (BMD) with dual-energy x-ray absorptiometry (DXA) in adolescent girls with anorexia nervosa (AN) and to compare these results with those in normal-weight control subjects. MATERIALS ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2492080173
更新日期:2008-12-01 00:00:00
abstract::Formal ethical approval was granted by the local research ethics committee; all participants gave written consent. The purpose of the study was to prospectively evaluate the feasibility of a noninvasive method of breast tumor localization in 25 participants, based on the coregistration of three-dimensional (3D) ultras...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2452060906
更新日期:2007-11-01 00:00:00
abstract::Shoulder arthrography is a reliable technique for use in the diagnosis of tears of the rotator cuff, although delineation of the precise site and size of tears requires meticulous double-contrast technique and considerable examiner expertise. The authors initiated a prospective evaluation of digital arthrography of th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.168.3.3406400
更新日期:1988-09-01 00:00:00
abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.4001390
更新日期:1985-06-01 00:00:00
abstract::The author reviews the regulatory process through which new cardiovascular interventional devices reach the hands of the interventional radiologist and the cardiologist. The marketing mechanisms are outlined, as are the data requirements. The reader is taken step-by-step from device investigation conducted under an ap...
journal_title:Radiology
pub_type: 临床试验,杂志文章
doi:10.1148/radiology.174.3.174-3-923
更新日期:1990-03-01 00:00:00
abstract::Excretory urography could be performed less frequently if some combinations of genitourinary signs and symptoms were found to be predictive of either a specific disease or normality. To explore this possibility, the authors conducted a prospective study involving more than 3,000 patients at three institutions (a teach...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.3.3969460
更新日期:1985-03-01 00:00:00
abstract::Magnetic resonance images of cranial bone marrow in 238 patients (246 examinations) less than 25 years old were reviewed to establish normal age-related standards. Bone marrow in the clivus and calvaria had uniformly low signal intensity (grade 1) on T1-weighted images in most infants less than 1 year old. The number ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.171.1.2928520
更新日期:1989-04-01 00:00:00
abstract::The Quantitative Imaging Biomarkers Alliance (QIBA) Profile for fluorodeoxyglucose (FDG) PET/CT imaging was created by QIBA to both characterize and reduce the variability of standardized uptake values (SUVs). The Profile provides two complementary claims on the precision of SUV measurements. First, tumor glycolytic a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2019191882
更新日期:2020-03-01 00:00:00
abstract:PURPOSE:To assess the value of magnetic resonance (MR) imaging in the detection of postoperative complications after composite valve graft replacement. MATERIALS AND METHODS:Spin-echo and gradient-echo MR imaging was performed in 52 patients 1/2 to 200 months after composite graft replacement of the ascending aorta (2...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.2.r99au02573
更新日期:1999-08-01 00:00:00