Biomechanical aspects: Summary and consensus statements of group 4. The 5th EAO Consensus Conference 2018.

Abstract:

OBJECTIVES:The aim of the present publication was to report on the EAO Workshop group-4 discussions and consensus statements on the five reviews previously prepared. These reviews provided the scientific evidence on the effect of crown-to-implant ratio, on reconstructions with cantilevers in fully and partially edentulous patients, on biological and technical complications of tilted in comparison with straight implants, and on the effects of osseointegrated implants functioning in a residual dentition. MATERIAL AND METHODS:The group discussed, evaluated, corrected where deemed appropriate, and made recommendations to the authors regarding the following five reviews submitted: (a) Is there an effect of crown-to-implant ratio on implant treatment outcomes?; (b) Implant-supported cantilevered fixed dental rehabilitations in fully edentulous patients; (c) and in partially edentulous patients; (d) Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses; (e) What are the adverse effects of osseointegrated implants functioning among natural teeth of a residual dentition? Based on the five manuscripts and the discussion among the group as well as the plenum members, the major findings were summarized, consensus statements were formulated, clinical recommendations were proposed, and areas of future research were identified. RESULTS:Crown-to-implant ratios ranging from 0.9 to 2.2 did not influence the occurrence of biological or technical complications also in single-tooth restorations. Reconstructions with cantilevers for the rehabilitation of fully and partially edentulous jaws showed high implant and reconstruction survival rates. In contrast, the rate of complications-in particular associated with veneering material-was high during the observation period of 5-10 years. The data reported were primarily derived from studies with high risk of bias. The data for single-implant reconstructions were small. There was no evidence that distally tilted implants were associated with higher failure rates and increased amounts of marginal bone loss. The data supporting these findings, however, were at high risk of bias and frequently incompletely reported. Frequent positional changes occurred between the natural teeth and the implant-supported restorations. These changes were more pronounced in younger individuals, and even though they were reduced with age, they still occurred in adult patients. Even though these changes were frequent, potential implications for the patient are unclear. CONCLUSIONS:The use of single-tooth restorations with crown-to-implant ratio in between 0.9 and 2.2 may be considered a viable treatment option. Multiunit reconstructions with cantilevers are a viable treatment option in fully and partially edentulous patients. Clinicians and patients should be aware, however, that complications are frequent and primarily related to resin material used for veneering. There is some evidence that tilting an implant does affect stability of the implant and the surrounding bone. Treatment options to tilted implants should carefully be considered, as the effect on soft tissues and on prosthesis behavior is poorly reported for tilted implants. Positional changes in the dentition in relation to implant-supported restorations occur frequently. The patient should be informed about the possible need for a treatment related to these changes in the long term.

journal_name

Clin Oral Implants Res

authors

Hämmerle CHF,Cordaro L,Alccayhuaman KAA,Botticelli D,Esposito M,Colomina LE,Gil A,Gulje FL,Ioannidis A,Meijer H,Papageorgiou S,Raghoebar G,Romeo E,Renouard F,Storelli S,Torsello F,Wachtel H

doi

10.1111/clr.13284

subject

Has Abstract

pub_date

2018-10-01 00:00:00

pages

326-331

eissn

0905-7161

issn

1600-0501

journal_volume

29 Suppl 18

pub_type

共识发展会议,杂志文章
  • A 7-year life table analysis from a prospective study on ITI implants with special emphasis on the use of short implants. Results from a private practice.

    abstract::This paper reports on a 7-year life table analysis on ITI titanium plasma-sprayed (TPS) and sandblasted and etched (SLA) implants placed in a private practice and loaded for at least 1 year. In 236 patients, 528 (264 TPS and 264 SLA) implants were placed, 351 (66.5%) implants rehabilitated the posterior region and 71....

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2004.00978.x

    authors: Nedir R,Bischof M,Briaux JM,Beyer S,Szmukler-Moncler S,Bernard JP

    更新日期:2004-04-01 00:00:00

  • Retraction.

    abstract::Ramírez-Fernández MP, Calvo-Guirado JL, Arcesio Delgado-Ruiz R, Maté-Sánchez del Val JE, Gómez-Moreno G, Guardia J. Experimental model of bone response to xenografts of bovine origin (Endobon® ): a radiological and histomorphometric study. Clin Oral Impl Res. 2011;22: 727-734. The above article, published online on 29...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,撤回出版物

    doi:10.1111/clr.13085

    authors:

    更新日期:2018-06-01 00:00:00

  • A systematic review of implant outcomes in treated periodontitis patients.

    abstract:OBJECTIVES:To investigate the effect of treated periodontitis on implant outcomes in partially edentulous individuals compared with periodontally healthy patients. MATERIAL AND METHODS:Longitudinal studies reporting on implant survival, success, incidence of peri-implantitis, bone loss and periodontal status, and on p...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,评审

    doi:10.1111/clr.12684

    authors: Sousa V,Mardas N,Farias B,Petrie A,Needleman I,Spratt D,Donos N

    更新日期:2016-07-01 00:00:00

  • Influence of decortication of the donor bone on guided bone augmentation. An experimental study in the rabbit skull bone.

    abstract::The aim of the present study was to evaluate if early access to the endosteal bone compartment by removal of the outer cortical bone plate will enhance bone augmentation in a secluded space. Two titanium cylinders were placed on the skull of each of 8 rabbits. Each cylinder was placed into a circular slit, secured to ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:

    authors: Lundgren AK,Lundgren D,Hämmerle CH,Nyman S,Sennerby L

    更新日期:2000-04-01 00:00:00

  • Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system.

    abstract::It has been documented that the long-term clinical outcome of the Brånemark system is very favourable. However, failures do occur before and after loading. This study examined the differences in marginal bone loss between standard and self-tapping fixtures and attempted to explain excessive marginal bone loss or loss ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1992.030302.x

    authors: Quirynen M,Naert I,van Steenberghe D

    更新日期:1992-09-01 00:00:00

  • Esthetic, clinical and patient-centered outcomes of immediately placed implants (Type 1) and early placed implants (Type 2): preliminary 3-month results of an ongoing randomized controlled clinical trial.

    abstract:AIM:The objective of the study was to compare (i) esthetic, (ii) clinical and (iii) patient-centered outcomes following immediate (Type 1) and early implant placement (Type 2). MATERIAL AND METHODS:Thirty-eight subjects needing a single extraction (premolar to premolar) were randomly allocated to Type 1 or Type 2 impl...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.12577

    authors: Huynh-Ba G,Meister DJ,Hoders AB,Mealey BL,Mills MP,Oates TW,Cochran DL,Prihoda TJ,McMahan CA

    更新日期:2016-02-01 00:00:00

  • Clinical study on survival rate of short implants placed in the posterior mandibular region: resonance frequency analysis.

    abstract:OBJECTIVE:Short implants are increasingly used, but there is doubt about their performance being similar to that of regular implants. The aim of this study was to compare the mechanical stability of short implants vs. regular implants placed in the edentulous posterior mandible. MATERIAL AND METHODS:Twenty-three patie...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12394

    authors: Queiroz TP,Aguiar SC,Margonar R,de Souza Faloni AP,Gruber R,Luvizuto ER

    更新日期:2015-09-01 00:00:00

  • Effect of socket preservation therapies following tooth extraction in non-molar regions in humans: a systematic review.

    abstract:OBJECTIVE:To assess, based on the existing literature, the benefit of socket preservation therapies in patients with a tooth extraction in the anterior or premolar region as compared with no additional treatment with respect to bone level. MATERIAL AND METHODS:MEDLINE-PubMed and the Cochrane Central Register of contro...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0501.2010.02064.x

    authors: Ten Heggeler JM,Slot DE,Van der Weijden GA

    更新日期:2011-08-01 00:00:00

  • Effects of Simvastatin on bone healing around titanium implants in osteoporotic rats.

    abstract:OBJECTIVES:Osteoporosis is known to impair the process of implant osseointegration. The recent discovery that statins (HMG-CoA reductase inhibitors) act as bone anabolic agents suggests that statins can be used as potential agents in the treatment of osteoporosis. Therefore, we hypothesized that statins will promote os...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2008.01630.x

    authors: Du Z,Chen J,Yan F,Xiao Y

    更新日期:2009-02-01 00:00:00

  • Immediate vs. conventional loading of palatal implants in humans.

    abstract:OBJECTIVES:To analyze the clinical performance and bone-to-implant contact (BIC) rate of two loading concepts on successfully healed and explanted palatal implants in humans. METHODS:From 2000 to 2006, two independent groups of patients, requiring maximum anchorage, were treated. Group 1 (n=36) was subjected to immedi...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2009.01732.x

    authors: Göllner P,Jung BA,Kunkel M,Liechti T,Wehrbein H

    更新日期:2009-08-01 00:00:00

  • Protease activities in peri-implant sulcus fluid from patients with permucosal osseointegrated dental implants. Correlation with clinical parameters.

    abstract::The 15 patients included in this study each had 2-6 permucosal Branemark osseointegrated implants that had functioned successfully for 18 months or more. They were given a full oral examination which included measurements of probing depth and gingival, bleeding and plaque indices around the implants. Marginal bone red...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1991.020203.x

    authors: Eley BM,Cox SW,Watson RM

    更新日期:1991-04-01 00:00:00

  • Bone-conditioned medium modulates the osteoconductive properties of collagen membranes in a rat calvaria defect model.

    abstract:OBJECTIVES:Collagen membranes are not limited to be occlusive barriers as they actively support bone regeneration. However, the impact of bone-derived growth factors on their osteoconductive competence has not been examined. METHODS:Twenty adult Sprague Dawley rats were included in the study. Calvaria defects with a d...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13133

    authors: Kuchler U,Rybaczek T,Dobask T,Heimel P,Tangl S,Klehm J,Menzel M,Gruber R

    更新日期:2018-04-01 00:00:00

  • Positive effect of strontium-oxide layer on the osseointegration of moderately rough titanium surface in non-osteoporotic rabbits.

    abstract:OBJECTIVES:To evaluate the effect of strontium-oxide layer on new bone formation and osseointegration of sandblasted large-grit double-acid-etched (SLA) implant. MATERIAL AND METHODS:Strontium-oxide layer on the SLA surface was produced by hydrothermal treatment using a Sr-containing solution. The surface topographies...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12897

    authors: Fan YP,Chen XY,Chen Y,Yang GL,Wang HM,He FM

    更新日期:2017-08-01 00:00:00

  • Soft tissue response to clinically contaminated and thereafter cleaned titanium surfaces. An experimental study in the rat.

    abstract::The aim of the present study was to evaluate the soft tissue response to intra-orally exposed and contaminated titanium surfaces (machined, blasted or polished) after being chemically and/or mechanically cleaned. Eight adult Sprague-Dawley rats were used for histomorphometrical and histological analyses. A total of 44...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.2000.011004370.x

    authors: Ericsson I,Lekholm U,Sennerby L,Holmén A

    更新日期:2000-08-01 00:00:00

  • Effect of plastic-covered ultrasonic scalers on titanium implant surfaces.

    abstract:OBJECTIVES:Maintaining oral health around titanium implants is essential. The formation of a biofilm on the titanium surface will influence the continuing success of the implant. These concerns have led to modified ultrasonic scaler instruments that look to reduce implant damage while maximising the cleaning effect. Th...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2011.02186.x

    authors: Mann M,Parmar D,Walmsley AD,Lea SC

    更新日期:2012-01-01 00:00:00

  • Endoscopically controlled sinus floor augmentation. A preliminary report.

    abstract::Sinus augmentation has been advocated to be a surgical technique with predictable results in peri-implant surgery. Endoscopic surgery of the maxillary sinus so far has been used as diagnostic procedure. In this paper, the use of endoscopy is described as a low invasive adjunctive technique in sinus floor augmentation....

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1997.080612.x

    authors: Engelke W,Deckwer I

    更新日期:1997-12-01 00:00:00

  • 'Bone map' for a safe placement of miniscrews generated by computed tomography.

    abstract:OBJECTIVES:The aim of this manuscript is to provide a bone map that can be used as a general guide to determine the areas where miniscrews can be safely anchored. MATERIALS AND METHODS:Twenty-one computed tomographies (CTs) of maxilla and mandible were taken by the imaging centre ORTOSCAN and two measures were taken: ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2007.01507.x

    authors: Hernández LC,Montoto G,Puente Rodríguez M,Galbán L,Martínez V

    更新日期:2008-06-01 00:00:00

  • The antibiotic of choice determined by antibiogram in maxillary sinus elevation surgery: a clinical study.

    abstract:OBJECTIVES:This study set out to make antibiograms of positive bacteria cultures in samples collected when performing maxillary sinus elevations to determine a specific and effective antibiotic in each case. MATERIAL AND METHODS:A total of 174 patients (90 women and 84 men) with a mean age of 55.92 years underwent 227...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12835

    authors: Carreño Carreño J,Gómez-Moreno G,Aguilar-Salvatierra A,Martínez Corriá R,Menéndez López-Mateos ML,Menéndez-Núñez M

    更新日期:2018-11-01 00:00:00

  • Enhanced osteoblast response to hydrophilic strontium and/or phosphate ions-incorporated titanium oxide surfaces.

    abstract:OBJECTIVE:This study investigated the surface characteristics and in vitro biocompatibility of titanium (Ti) surfaces incorporated with strontium ions (Sr) and/or phosphate ions (P) produced by hydrothermal treatment for future applications as endosseous implant surfaces. MATERIAL AND METHODS:Sr and/or P-incorporated ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2009.01863.x

    authors: Park JW,Kim YJ,Jang JH

    更新日期:2010-04-01 00:00:00

  • Novel bone substitute material in alveolar bone healing following tooth extraction: an experimental study in sheep.

    abstract:OBJECTIVES:Electrospun cotton wool-like nanocomposite (ECWN) is a novel synthetic bone substitute that incorporates amorphous calcium phosphate nanoparticles into a biodegradable synthetic copolymer poly(lactide-co-glycolide). The objectives of this study were to develop a tooth extraction socket model in sheep for bon...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12673

    authors: Liu J,Schmidlin PR,Philipp A,Hild N,Tawse-Smith A,Duncan W

    更新日期:2016-07-01 00:00:00

  • Performance of dental implants after staged sinus floor elevation procedures: 5-year results of a prospective study in partially edentulous patients.

    abstract:OBJECTIVES:The aim of this prospective study was to evaluate the 5-year performance and success rate of titanium screw-type implants with the titanium plasma spray (TPS) or the sand-blasted, large grit, acid-etched (SLA) surface inserted in a two-stage sinus floor elevation (SFE) procedure in the posterior maxilla. MA...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2008.01573.x

    authors: Bornstein MM,Chappuis V,von Arx T,Buser D

    更新日期:2008-10-01 00:00:00

  • Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.

    abstract::In the literature intraoral periapical radiographs are commonly used for densitometric measurements of the mandible with implants. These films give detailed information of the implant and the surrounding bone. However, in extreme mandibular atrophy it can be difficult to obtain intraoral radiographs of adequate diagno...

    journal_title:Clinical oral implants research

    pub_type: 临床试验,杂志文章

    doi:10.1034/j.1600-0501.2000.011005476.x

    authors: Verhoeven JW,Ruijter J,Cune MS,Terlou M

    更新日期:2000-10-01 00:00:00

  • Radiographic changes in height and volume after lateral GBR procedures with different ratios of deproteinized bovine bone mineral and autogenous bone at different time points. An experimental study.

    abstract:OBJECTIVE:Estimate changes in augmentation height and volume after lateral guided bone regeneration (GBR) augmentation with different ratios of deproteinized bovine bone mineral (DBBM) and particulate autogenous bone (PAB) and autogenous bone block (ABB), at different time points. MATERIAL AND METHODS:Twenty-four mini...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13687

    authors: Aludden H,Mordenfeld A,Cederlund A,Dahlin C,Spin-Neto R,Veiss-Pedersen P,Sritharan B,Starch-Jensen T

    更新日期:2020-11-20 00:00:00

  • Characterization of the antioxidant profile of human saliva in peri-implant health and disease.

    abstract:OBJECTIVES:Peri-implant disease is considered to be an inflammatory disease, but many aspects of its pathogenesis remain unknown. At present, peri-implant disease is considered to be initiated and perpetuated by a small group of predominantly Gram-negative, anaerobic, or micro-aerophilic bacteria that colonize the subg...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2006.01296.x

    authors: Liskmann S,Vihalemm T,Salum O,Zilmer K,Fischer K,Zilmer M

    更新日期:2007-02-01 00:00:00

  • Implant-tissue interfaces following treatment of peri-implantitis using guided tissue regeneration: a light and electron microscopic study.

    abstract::This study details the structural and ultrastructural features of the interfaces between titanium implants and their surrounding tissues. The material stemmed from an experiment in dogs in which guided tissue regeneration with Gore-Tex membranes was used to treat peri-implant, ligature-induced tissue breakdown around ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1994.050201.x

    authors: Schüpbach P,Hürzeler M,Grunder U

    更新日期:1994-06-01 00:00:00

  • Radiographic evaluation of conical tapered platform-switched implants in the posterior mandible: 1-year results of a two-center prospective study.

    abstract:OBJECTIVE:Long-term success of dental implants depends on healthy peri-implant soft tissues and adequate bone levels. This prospective study aims to assess bone level changes around implants with internal conical connection and platform-switching abutments in the posterior mandible. MATERIAL AND METHODS:Adult patients...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,多中心研究

    doi:10.1111/clr.12644

    authors: Moergel M,Rocha S,Messias A,Nicolau P,Guerra F,Wagner W

    更新日期:2016-06-01 00:00:00

  • Healing after standardized clinical probing of the perlimplant soft tissue seal: a histomorphometric study in dogs.

    abstract:BACKGROUND/AIMS:Clinical probing of the soft tissues around oral implants has become a frequently used parameter for clinical monitoring. However, the healing of the disruption of the soft tissue seal as a result of probing has not yet been studied. The purpose of this study was to evaluate the healing events in the pe...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.2002.130601.x

    authors: Etter TH,Håkanson I,Lang NP,Trejo PM,Caffesse RG

    更新日期:2002-12-01 00:00:00

  • Primary stability, insertion torque and bone density of cylindric implant ad modum Branemark: is there a relationship? An in vitro study.

    abstract:OBJECTIVES:Protocols of immediate loading have been reported in several studies. It has also been demonstrated that the cause of failure of immediate loaded implants is due to the micromotion on the bone-implant interface induced by immediate loading. There should be a minimum gap between the implant and the peri-impla...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2010.02036.x

    authors: Trisi P,De Benedittis S,Perfetti G,Berardi D

    更新日期:2011-05-01 00:00:00

  • A five-year life-table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice.

    abstract::This paper reports a 5-year life-table analysis on wide neck (WN) ITI implants placed in a private practice. In 212 patients, 263 implants were placed in the posterior region; 97% rehabilitated the molar area. Implants in the mandible and in the maxilla were 61.2% and 38.8%, respectively; the mean implant length was 9...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2006.01271.x

    authors: Bischof M,Nedir R,Abi Najm S,Szmukler-Moncler S,Samson J

    更新日期:2006-10-01 00:00:00

  • Early biocompatibility of poly (ethylene glycol) hydrogel barrier materials for guided bone regeneration. An in vitro study using human gingival fibroblasts (HGF-1).

    abstract:OBJECTIVES:To evaluate the early cellular attachment and viability to modified polyethylene glycol (PEG) hydrogels with the influence of arginine-glycine-aspartic acid (RGD) in an in vitro model system. MATERIAL AND METHODS:Human gingival fibroblasts (HGF-1) were cultured on 6 different modalities of PEG hydrogel in h...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12076

    authors: Dahlin C,Johansson A,Hoffman M,Molenberg A

    更新日期:2014-01-01 00:00:00