Prophylactic balloon occlusion of internal iliac arteries, common iliac arteries and infrarenal abdominal aorta in pregnancies complicated by placenta accreta: a retrospective cohort study.

Abstract:

OBJECTIVES:To evaluate the efficacy of prophylactic balloon occlusion (PBO), and to compare haemostatic effects and perioperative outcomes of PBO of the internal iliac arteries (IIA), common iliac arteries (CIA) and infrarenal abdominal aorta (IAA) in patients with placenta accreta. METHODS:One hundred and ninety-nine patients with placenta accreta were retrospectively reviewed. One hundred and twelve cases who underwent PBO were allocated into PBO group, and 87 cases without endovascular intervention were classified as the control group. According to different methods, 112 patients in the PBO group were divided into IIA (n = 37), CIA (n = 42) and IAA (n = 33) subgroups. RESULTS:Patients in the PBO group had decreased estimated blood loss (EBL) and blood transfusion volume (BTV), as well as improved other perioperative outcomes. PBO (vs controls) could independently predict less EBL. As to comparison among subgroups, patients had decreased EBL and BTV, as well as improved other perioperative outcomes in CIA and IAA subgroups compared to the IIA subgroup. Further validation by multivariate analysis revealed that PBO of IIA (vs others) could independently predict more EBL. CONCLUSIONS:PBO reduces intraoperative blood loss and improves other perioperative outcomes in patients with placenta accreta, and PBO of the CIA and IAA is more effective compared to PBO of IIA. KEY POINTS:• PBO of IIA, CIA and IAA is effective in placenta accreta. • PBO of CIA and IAA is more effective. • PBO could independently predict less EBL. • Accreta depth was an independent risk factor for EBL.

journal_name

Eur Radiol

journal_title

European radiology

authors

Li K,Zou Y,Sun J,Wen H

doi

10.1007/s00330-018-5527-7

subject

Has Abstract

pub_date

2018-12-01 00:00:00

pages

4959-4967

issue

12

eissn

0938-7994

issn

1432-1084

pii

10.1007/s00330-018-5527-7

journal_volume

28

pub_type

杂志文章
  • A novel approach to digital breast tomosynthesis for simultaneous acquisition of 2D and 3D images.

    abstract:OBJECTIVE:The complexity of anatomical structure within the breast represents the ultimate limit to signal detection on a mammogram. To increase lesion conspicuity Digital Breast Tomosynthesis (DBT) has been recently proposed and several manufacturers are currently performing clinical trials. In this study we investiga...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-2041-y

    authors: Vecchio S,Albanese A,Vignoli P,Taibi A

    更新日期:2011-06-01 00:00:00

  • Benchmarking pediatric cranial CT protocols using a dose tracking software system: a multicenter study.

    abstract:OBJECTIVES:To benchmark regional standard practice for paediatric cranial CT-procedures in terms of radiation dose and acquisition parameters. METHODS:Paediatric cranial CT-data were retrospectively collected during a 1-year period, in 3 different hospitals of the same country. A dose tracking system was used to autom...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-016-4385-4

    authors: De Bondt T,Mulkens T,Zanca F,Pyfferoen L,Casselman JW,Parizel PM

    更新日期:2017-02-01 00:00:00

  • Quantitative CT detects progression in COPD patients with severe emphysema in a 3-month interval.

    abstract:OBJECTIVES:Chronic obstructive pulmonary disease (COPD) is characterized by variable contributions of emphysema and airway disease on computed tomography (CT), and still little is known on their temporal evolution. We hypothesized that quantitative CT (QCT) is able to detect short-time changes in a cohort of patients w...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06577-y

    authors: Konietzke P,Wielpütz MO,Wagner WL,Wuennemann F,Kauczor HU,Heussel CP,Eichinger M,Eberhardt R,Gompelmann D,Weinheimer O

    更新日期:2020-05-01 00:00:00

  • Evidence-based recommendations for musculoskeletal kinematic 4D-CT studies using wide area-detector scanners: a phantom study with cadaveric correlation.

    abstract:PROPOSE:To establish evidence-based recommendations for musculoskeletal kinematic 4D-CT on wide area-detector CT. MATERIALS AND METHODS:In order to assess factors influencing image quality in kinematic CT studies, a phantom consisting of a polymethylmethacrylate rotating disk with round wells of different sizes was im...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4362-y

    authors: Gondim Teixeira PA,Formery AS,Hossu G,Winninger D,Batch T,Gervaise A,Blum A

    更新日期:2017-02-01 00:00:00

  • Meta-analysis: adjusted indirect comparison of drug-eluting bead transarterial chemoembolization versus 90Y-radioembolization for hepatocellular carcinoma.

    abstract:OBJECTIVE:To investigate comparative effectiveness of drug-eluting bead transarterial chemoembolization (DEB-TACE) versus Yttrium-90 (90Y)-radioembolization for hepatocellular carcinoma (HCC). METHODS:Studies comparing conventional (c)TACE versus 90Y-radioembolization or DEB-TACE for HCC treatment were identified usin...

    journal_title:European radiology

    pub_type: 杂志文章,meta分析

    doi:10.1007/s00330-016-4548-3

    authors: Ludwig JM,Zhang D,Xing M,Kim HS

    更新日期:2017-05-01 00:00:00

  • Assessment of calcium scoring performance in cardiac computed tomography.

    abstract::Electron beam tomography (EBT) has been used for cardiac diagnosis and the quantitative assessment of coronary calcium since the late 1980s. The introduction of mechanical multi-slice spiral CT (MSCT) scanners with shorter rotation times opened new possibilities of cardiac imaging with conventional CT scanners. The pu...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-002-1746-y

    authors: Ulzheimer S,Kalender WA

    更新日期:2003-03-01 00:00:00

  • CT assessment-based direct surgical resection of part-solid nodules with solid component larger than 5 mm without preoperative biopsy: experience at a single tertiary hospital.

    abstract:OBJECTIVES:To retrospectively evaluate the feasibility of CT assessment-based direct surgical resection of part-solid nodules (PSNs) with solid components > 5 mm without preoperative percutaneous transthoracic needle biopsies (PTNBs). METHODS:From January 2009-December 2014, 85 PSNs with solid components > 5 mm on CT ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-4917-6

    authors: Lee SM,Park CM,Song YS,Kim H,Kim YT,Park YS,Goo JM

    更新日期:2017-12-01 00:00:00

  • Short tau inversion recovery and proton density-weighted fat suppressed sequences for the evaluation of osteoarthritis of the knee with a 1.0 T dedicated extremity MRI: development of a time-efficient sequence protocol.

    abstract::Aim of this study was to develop a time-efficient sequence protocol for a 1.0 T dedicated MR system to be used for whole-organ scoring of osteoarthritis (OA). Thirty-four knees were examined using a protocol that included fat suppressed fast spin echo proton density weighted sequences (PDFS) in three planes plus a cor...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-004-2608-6

    authors: Roemer FW,Guermazi A,Lynch JA,Peterfy CG,Nevitt MC,Webb N,Li J,Mohr A,Genant HK,Felson DT

    更新日期:2005-05-01 00:00:00

  • Re-exposure to low osmolar iodinated contrast media in patients with prior moderate-to-severe hypersensitivity reactions: A multicentre retrospective cohort study.

    abstract:OBJECTIVES:To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). METHODS:We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-016-4682-y

    authors: Park HJ,Park JW,Yang MS,Kim MY,Kim SH,Jang GC,Nam YH,Kim GW,Kim S,Park HK,Jung JW,Park JS,Kang HR

    更新日期:2017-07-01 00:00:00

  • Detection and characterisation of liver metastases.

    abstract::Modern liver imaging of cancer patients requires an imaging modality that is not only highly sensitive in detecting lesions but also provides reliable characterisation of lesions and thus allows differentiation of metastases from frequently found benign lesions. Conventional ultrasound (US) has a relatively poor sensi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s10406-004-0088-z

    authors: Albrecht T,Hohmann J,Oldenburg A,Skrok J,Wolf KJ

    更新日期:2004-10-01 00:00:00

  • Post-imaging pulmonary nodule mathematical prediction models: are they clinically relevant?

    abstract:OBJECTIVES:Post-imaging mathematical prediction models (MPMs) provide guidance for the management of solid pulmonary nodules by providing a lung cancer risk score from demographic and radiologists-indicated imaging characteristics. We hypothesized calibrating the MPM risk score threshold to a local study cohort would r...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-019-06168-x

    authors: Uthoff J,Koehn N,Larson J,Dilger SKN,Hammond E,Schwartz A,Mullan B,Sanchez R,Hoffman RM,Sieren JC,COPDGene Investigators.

    更新日期:2019-10-01 00:00:00

  • Five-year survival in 309 patients with colorectal liver metastases treated with radiofrequency ablation.

    abstract::There is little published long-term survival data for patients with colorectal liver metastases treated with radiofrequency ablation (RFA). We present a multivariate analysis of 5-year survival in 309 patients (198 male, aged 64 (24-92)) treated at 617 sessions. Our standard protocol used internally cooled electrodes ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-008-1258-5

    authors: Gillams AR,Lees WR

    更新日期:2009-05-01 00:00:00

  • Smart chest X-ray worklist prioritization using artificial intelligence: a clinical workflow simulation.

    abstract:OBJECTIVE:The aim is to evaluate whether smart worklist prioritization by artificial intelligence (AI) can optimize the radiology workflow and reduce report turnaround times (RTATs) for critical findings in chest radiographs (CXRs). Furthermore, we investigate a method to counteract the effect of false negative predict...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07480-7

    authors: Baltruschat I,Steinmeister L,Nickisch H,Saalbach A,Grass M,Adam G,Knopp T,Ittrich H

    更新日期:2020-11-21 00:00:00

  • Imaging of aortic dissection by helical computed tomography (CT).

    abstract::Aortic dissection is the most frequent cause of aortic emergency, and its outcome is still frequently fatal. The management of this pathology has changed with the development of endovascular means. Nowadays, imaging modalities are helpful in management decision-making by providing information such as identification of...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-004-2441-y

    authors: Willoteaux S,Lions C,Gaxotte V,Negaiwi Z,Beregi JP

    更新日期:2004-11-01 00:00:00

  • Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

    abstract:OBJECTIVE:To examine the association between the appearance of hyperechoic marks (HEMs) during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules and nodule shrinkage at 6 months. METHODS:One hundred and thirty-six patients who underwent HIFU for benign thyroid nodule were analysed. An indepen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5207-z

    authors: Lang BHH,Woo YC,Chiu KW

    更新日期:2018-06-01 00:00:00

  • Larger corpus callosum and reduced orbitofrontal cortex homotopic connectivity in codeine cough syrup-dependent male adolescents and young adults.

    abstract:OBJECTIVES:To characterize interhemispheric functional and anatomical connectivity and their relationships with impulsive behaviour in codeine-containing cough syrup (CCS)-dependent male adolescents and young adults. METHODS:We compared volumes of corpus callosum (CC) and its five subregion and voxel-mirrored homotopi...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-016-4465-5

    authors: Qiu YW,Lv XF,Jiang GH,Su HH,Ma XF,Tian JZ,Zhuo FZ

    更新日期:2017-03-01 00:00:00

  • TACE with degradable starch microspheres (DSM-TACE) as second-line treatment in HCC patients dismissing or ineligible for sorafenib.

    abstract:OBJECTIVES:To date, there is no approved second-line treatment for patients dismissing sorafenib or ineligible for this treatment, so it would be useful to find an effective alternative treatment option. The aim of our study was to evaluate safety, feasibility and effectiveness of transarterial chemoembolisation with d...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-018-5692-8

    authors: Iezzi R,Pompili M,Rinninella E,Annicchiarico E,Garcovich M,Cerrito L,Ponziani F,De Gaetano A,Siciliano M,Basso M,Zocco MA,Rapaccini G,Posa A,Carchesio F,Biolato M,Giuliante F,Gasbarrini A,Manfredi R,HepatoCatt Study G

    更新日期:2019-03-01 00:00:00

  • Dynamic MR imaging of osteoid osteomas: correlation of semiquantitative and quantitative perfusion parameters with patient symptoms and treatment outcome.

    abstract:OBJECTIVE:To evaluate the relationship between multiple MR perfusion parameters and symptoms of patients with osteoid osteomas after percutaneous laser therapy. METHODS:MR perfusion studies of 20 patients diagnosed with an osteoid osteoma, treated with CT-guided percutaneous laser therapy, were retrospectively evaluat...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-013-2867-1

    authors: Teixeira PA,Chanson A,Beaumont M,Lecocq S,Louis M,Marie B,Sirveaux F,Blum A

    更新日期:2013-09-01 00:00:00

  • Comparison of transient severe motion in gadoxetate disodium and gadopentetate dimeglumine-enhanced MRI: effect of modified breath-holding method.

    abstract:OBJECTIVES:To compare the occurrence of transient severe motion (TSM) between gadoxetate disodium- and gadopentetate dimeglumine-enhanced MRI and between gadoxetate disodium-enhanced MRI scans obtained with and without the application of a modified breath-holding technique. METHODS:We reviewed 80 patients who underwen...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-017-5070-y

    authors: Song JS,Choi EJ,Park EH,Lee JH

    更新日期:2018-03-01 00:00:00

  • Use of dual-energy CT for renal mass assessment.

    abstract::Although dual-energy CT (DECT) may prove useful in a variety of abdominal imaging tasks, renal mass evaluation represents the area where this technology can be most impactful in abdominal imaging compared to routinely performed contrast-enhanced-only single-energy CT exams. DECT post-processing techniques, such as cre...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-020-07426-z

    authors: Thiravit S,Brunnquell C,Cai LM,Flemon M,Mileto A

    更新日期:2020-11-18 00:00:00

  • Automatic bolus tracking in monophasic spiral CT of the liver: liver-to-lesion conspicuity.

    abstract::The aim of this study was to evaluate the value of automatic bolus tracking for monophasic spiral CT of the liver and to assess the liver-to-lesion conspicuity in comparison with time-delay examinations. In 40 patients scheduled for therapy control of known hypovascular hepatic metastases a monophasic spiral CT was co...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300000637

    authors: Mehnert F,Pereira PL,Trübenbach J,Kopp AF,Claussen CD

    更新日期:2001-01-01 00:00:00

  • Standardizing percutaneous Microwave Ablation in the treatment of Lung Tumors: a prospective multicenter trial (MALT study).

    abstract:OBJECTIVES:To prospectively assess reproducibility, safety, and efficacy of microwave ablation (MWA) in the treatment of unresectable primary and secondary pulmonary tumors. METHODS:Patients with unresectable primary and metastatic lung tumors up to 4 cm were enrolled in a multicenter prospective clinical trial and un...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-020-07299-2

    authors: Iezzi R,Cioni R,Basile D,Tosoratti N,Posa A,Busso M,Cappelli C,Margaritora S,Ambrogi MC,Cassano A,Scandiffio R,Calandri M,Crocetti L,Valentini V,Manfredi R,Veltri A

    更新日期:2020-09-30 00:00:00

  • Three-dimensional dynamic magnetic resonance angiography for the evaluation of radiosurgically treated cerebral arteriovenous malformations.

    abstract::We assessed the value of three-dimensional (3D) dynamic magnetic resonance angiography (MRA) for the follow-up of patients with radiosurgically treated cerebral arteriovenous malformations (AVMs). Fifty-four patients with cerebral AVMs treated by radiosurgery (RS) were monitored using conventional catheter angiography...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-005-0011-6

    authors: Gauvrit JY,Oppenheim C,Nataf F,Naggara O,Trystram D,Munier T,Fredy D,Pruvo JP,Roux FX,Leclerc X,Meder JF

    更新日期:2006-03-01 00:00:00

  • Accuracy of helical CT for acute pulmonary embolism: ROC analysis of observer performance related to clinical experience.

    abstract::The aim of this study was to test the influence of observer experience on the accuracy for interpreting helical CT for acute pulmonary embolism (PE) and to identify sources of observer errors. Three observers of different expertise blindly assessed 147 helical CT scans for suspected PE (true status regarding absence o...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300050526

    authors: van Rossum AB,van Erkel AR,van Persijn van Meerten EL,Ton ER,Rebergen SA,Pattynama PM

    更新日期:1998-01-01 00:00:00

  • Impact of 64-slice coronary CT on the management of patients presenting with acute chest pain: results of a prospective two-centre study.

    abstract:OBJECTIVE:Our two-centre prospective study evaluates the usefulness of 64-slice coronary computed tomography (CCT) to rule out significant coronary artery stenosis in patients admitted in emergency departments (ED) for acute coronary syndromes (ACS) with low-to-intermediate risk score. METHODS:Patients (175) admitted ...

    journal_title:European radiology

    pub_type: 杂志文章,多中心研究

    doi:10.1007/s00330-011-2354-5

    authors: Christiaens L,Duchat F,Boudiaf M,Tasu JP,Fargeaudou Y,Ledref O,Soyer P,Sirol M

    更新日期:2012-05-01 00:00:00

  • Impact of high resolution 3 tesla MR neurography (MRN) on diagnostic thinking and therapeutic patient management.

    abstract:OBJECTIVE:To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. METHODS:IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatm...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-015-3958-y

    authors: Chhabra A,Belzberg AJ,Rosson GD,Thawait GK,Chalian M,Farahani SJ,Shores JT,Deune G,Hashemi S,Thawait SK,Subhawong TK,Carrino JA

    更新日期:2016-05-01 00:00:00

  • Correlation of texture analysis of paraspinal musculature on MRI with different clinical endpoints: Lumbar Stenosis Outcome Study (LSOS).

    abstract:OBJECTIVES:The aim of this study was to apply texture analysis (TA) on paraspinal musculature in T2-weighted (T2w) magnetic resonance images (MRI) of symptomatic lumbar spinal stenosis (LSS) patients and correlate the findings with clinical outcome measures. METHODS:Ninety patients were prospectively enrolled in the m...

    journal_title:European radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1007/s00330-018-5552-6

    authors: Mannil M,Burgstaller JM,Held U,Farshad M,Guggenberger R

    更新日期:2019-01-01 00:00:00

  • A rational approach to dose reduction in CT: individualized scan protocols.

    abstract::The aim of this study was to demonstrate that dose reduction and constant image quality can be achieved by adjusting X-ray dose to patient size. To establish the relation between patient size, image quality and dose we scanned 19 patients with reduced dose. Image noise was measured. Four radiologists scored image qual...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s003300101039

    authors: Wilting JE,Zwartkruis A,van Leeuwen MS,Timmer J,Kamphuis AG,Feldberg M

    更新日期:2001-01-01 00:00:00

  • MR-guided endovascular interventions: a comprehensive review on techniques and applications.

    abstract::The magnetic resonance (MR) guidance of endovascular interventions is probably one of the greatest challenges of clinical MR research. MR angiography is not only an imaging tool for the vasculature but can also simultaneously depict high tissue contrast, including the differentiation of the vascular wall and perivascu...

    journal_title:European radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00330-007-0818-4

    authors: Kos S,Huegli R,Bongartz GM,Jacob AL,Bilecen D

    更新日期:2008-04-01 00:00:00

  • Staging of uterine cervical cancer with MRI: guidelines of the European Society of Urogenital Radiology.

    abstract:OBJECTIVE:To design clear guidelines for the staging and follow-up of patients with uterine cervical cancer, and to provide the radiologist with a framework for use in multidisciplinary conferences. METHODS:Guidelines for uterine cervical cancer staging and follow-up were defined by the female imaging subcommittee of ...

    journal_title:European radiology

    pub_type: 杂志文章

    doi:10.1007/s00330-010-1998-x

    authors: Balleyguier C,Sala E,Da Cunha T,Bergman A,Brkljacic B,Danza F,Forstner R,Hamm B,Kubik-Huch R,Lopez C,Manfredi R,McHugo J,Oleaga L,Togashi K,Kinkel K

    更新日期:2011-05-01 00:00:00