A combination strategy based brain-computer interface for two-dimensional movement control.

Abstract:

OBJECTIVE:Two-dimensional (2D) movement control is an important issue in brain-computer interfaces (BCIs) research because being able to move, for example, a cursor with the brain will enable patients with motor disabilities to control their environment. However, it is still a challenge to continuously control 2D movement with a non-invasive BCI system. In this paper, we developed a 2D cursor control with motor imagery BCI tasks allowing users to move a cursor to any position by using a combination strategy. With this strategy, a user can combine multiple motor imagery tasks, alternatively or simultaneously, to control 2D movements. APPROACH:After a training session, six participants took part in the first control strategy experiment (the center-out experiment) to verify the effectiveness of the cursor control. Three of the six participants performed an additional experiment, in which they were required to move the cursor to hit five targets in a given sequence. MAIN RESULTS:The average hit rate was more than [Formula: see text] and the trajectories were close to the shortest path. The average hit rate was more than 95.6% and the trajectories were close to the shortest path in the center-out experiment. In the additional experiment, three participants achieved a 100% hit rate with a short trajectory. SIGNIFICANCE:The results demonstrated that users were able to effectively control the 2D movement using the proposed strategy. The present system may be used as a tool to interact with the external world.

journal_name

J Neural Eng

authors

Xia B,Maysam O,Veser S,Cao L,Li J,Jia J,Xie H,Birbaumer N

doi

10.1088/1741-2560/12/4/046021

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

046021

issue

4

eissn

1741-2560

issn

1741-2552

journal_volume

12

pub_type

杂志文章
  • Acoustoelectric imaging of deep dipoles in a human head phantom for guiding treatment of epilepsy.

    abstract:OBJECTIVE:This study employs a human head model with real skull to demonstrate the feasibility of transcranial acoustoelectric brain imaging (tABI) as a new modality for electrical mapping of deep dipole sources during treatment of epilepsy with much better resolution and accuracy than conventional mapping methods. AP...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb63a

    authors: Barragan A,Preston C,Alvarez A,Bera T,Qin Y,Weinand M,Kasoff W,Witte RS

    更新日期:2020-10-30 00:00:00

  • Control of a humanoid robot by a noninvasive brain-computer interface in humans.

    abstract::We describe a brain-computer interface for controlling a humanoid robot directly using brain signals obtained non-invasively from the scalp through electroencephalography (EEG). EEG has previously been used for tasks such as controlling a cursor and spelling a word, but it has been regarded as an unlikely candidate fo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/2/012

    authors: Bell CJ,Shenoy P,Chalodhorn R,Rao RP

    更新日期:2008-06-01 00:00:00

  • Evoked haptic sensations in the hand via non-invasive proximal nerve stimulation.

    abstract:OBJECTIVE:Haptic perception of a prosthetic limb or hand is a crucial, but often unmet, need which impacts the utility of the prostheses. In this study, we seek to evaluate the feasibility of a non-invasive transcutaneous nerve stimulation method in generating haptic feedback in a transradial amputee subject as well as...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aabd5d

    authors: Shin H,Watkins Z,Huang HH,Zhu Y,Hu X

    更新日期:2018-08-01 00:00:00

  • The development of neural stimulators: a review of preclinical safety and efficacy studies.

    abstract:OBJECTIVE:Given the rapid expansion of the field of neural stimulation and the rigorous regulatory approval requirements required before these devices can be applied clinically, it is important that there is clarity around conducting preclinical safety and efficacy studies required for the development of this technolog...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac43c

    authors: Shepherd RK,Villalobos J,Burns O,Nayagam DAX

    更新日期:2018-08-01 00:00:00

  • Decoder calibration with ultra small current sample set for intracortical brain-machine interface.

    abstract:OBJECTIVE:Intracortical brain-machine interfaces (iBMIs) aim to restore efficient communication and movement ability for paralyzed patients. However, frequent recalibration is required for consistency and reliability, and every recalibration will require relatively large most current sample set. The aim in this study i...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaa8a4

    authors: Zhang P,Ma X,Chen L,Zhou J,Wang C,Li W,He J

    更新日期:2018-04-01 00:00:00

  • Advantages of soft subdural implants for the delivery of electrochemical neuromodulation therapies to the spinal cord.

    abstract:OBJECTIVE:We recently developed soft neural interfaces enabling the delivery of electrical and chemical stimulation to the spinal cord. These stimulations restored locomotion in animal models of paralysis. Soft interfaces can be placed either below or above the dura mater. Theoretically, the subdural location combines ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaa87a

    authors: Capogrosso M,Gandar J,Greiner N,Moraud EM,Wenger N,Shkorbatova P,Musienko P,Minev I,Lacour S,Courtine G

    更新日期:2018-04-01 00:00:00

  • Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity.

    abstract:OBJECTIVE:Although electrode size should be miniaturized to provide higher selectivity for neural signal recording and to avoid tissue damage, small sized electrodes induce high impedance, which decreases recording quality. In this work, the electrode surface was modified to increase the effective surface area to lower...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056018

    authors: Chung T,Wang JQ,Wang J,Cao B,Li Y,Pang SW

    更新日期:2015-10-01 00:00:00

  • Decoding overt shifts of attention in depth through pupillary and cortical frequency tagging.

    abstract:OBJECTIVE:We have recently developed a prototype of a novel human-computer interface for assistive communication based on voluntary shifts of attention (gaze) from a far target to a near target associated with a decrease of pupil size (Pupillary Accommodative Response, PAR), an automatic vegetative response that can be...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8e8f

    authors: de'Sperati C,Roatta S,Zovetti N,Baroni T

    更新日期:2020-04-29 00:00:00

  • The statistical distribution of noisy transmission in human sensors.

    abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2560/10/1/016014

    authors: Neri P

    更新日期:2013-02-01 00:00:00

  • Myoelectric control with abstract decoders.

    abstract:OBJECTIVE:The objective of this study was to compare the use of muscles appropriate for partial-hand prostheses with those typically used for complete hand devices and to determine whether differences in their underlying neural substrates translate to different levels of myoelectric control. APPROACH:We developed a no...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacbfe

    authors: Dyson M,Barnes J,Nazarpour K

    更新日期:2018-10-01 00:00:00

  • Dynamics and coupling of fractional-order models of the motor cortex and central pattern generators.

    abstract:OBJECTIVE:Fractional calculus plays a key role in the analysis of neural dynamics. In particular, fractional calculus has been recently exploited for analyzing complex biological systems and capturing intrinsic phenomena. Also, artificial neural networks have been shown to have complex neuronal dynamics and characteris...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8dd6

    authors: Lu Q

    更新日期:2020-06-12 00:00:00

  • Intraneural sensory feedback restores grip force control and motor coordination while using a prosthetic hand.

    abstract:OBJECTIVE:Tactile afferents in the human hand provide fundamental information about hand-environment interactions, which is used by the brain to adapt the motor output to the physical properties of the object being manipulated. A hand amputation disrupts both afferent and efferent pathways from/to the hand, completely ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2552/ab059b

    authors: Clemente F,Valle G,Controzzi M,Strauss I,Iberite F,Stieglitz T,Granata G,Rossini PM,Petrini F,Micera S,Cipriani C

    更新日期:2019-04-01 00:00:00

  • Analysis of spontaneous MEG activity in mild cognitive impairment and Alzheimer's disease using spectral entropies and statistical complexity measures.

    abstract::Alzheimer's disease (AD) is the most common cause of dementia. Over the last few years, a considerable effort has been devoted to exploring new biomarkers. Nevertheless, a better understanding of brain dynamics is still required to optimize therapeutic strategies. In this regard, the characterization of mild cognitive...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036007

    authors: Bruña R,Poza J,Gómez C,García M,Fernández A,Hornero R

    更新日期:2012-06-01 00:00:00

  • Decoding multiclass motor imagery EEG from the same upper limb by combining Riemannian geometry features and partial least squares regression.

    abstract:OBJECTIVE:Due to low spatial resolution and poor signal-to-noise ratio of electroencephalogram (EEG), high accuracy classifications still suffer from lots of obstacles in the context of motor imagery (MI)-based brain-machine interface (BMI) systems. Particularly, it is extremely challenging to decode multiclass MI EEG ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba7cd

    authors: Chu Y,Zhao X,Zou Y,Xu W,Song G,Han J,Zhao Y

    更新日期:2020-08-11 00:00:00

  • The use of tungsten as a chronically implanted material.

    abstract::This review paper shows that tungsten should not generally be used as a chronically implanted material. The metal has a long implant history, from neuroscience, vascular medicine, radiography, orthopaedics, prosthodontics, and various other fields, primarily as a result of its high density, radiopacity, tensile streng...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/aaa502

    authors: Shah Idil A,Donaldson N

    更新日期:2018-04-01 00:00:00

  • Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation.

    abstract::We hypothesize that a visual prosthesis capable of evoking high-resolution visual perceptions can be produced using high-electrode-count arrays of penetrating microelectrodes implanted into the primary visual cortex of a blind human subject. To explore this hypothesis, and as a prelude to human psychophysical experime...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/3/035001

    authors: Torab K,Davis TS,Warren DJ,House PA,Normann RA,Greger B

    更新日期:2011-06-01 00:00:00

  • Neuromusculoskeletal model self-calibration for on-line sequential bayesian moment estimation.

    abstract:OBJECTIVE:Neuromusculoskeletal models involve many subject-specific physiological parameters that need to be adjusted to adequately represent muscle properties. Traditionally, neuromusculoskeletal models have been calibrated with a forward-inverse dynamic optimization which is time-consuming and unfeasible for rehabili...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa58f5

    authors: Bueno DR,Montano L

    更新日期:2017-04-01 00:00:00

  • Constant pressure fluid infusion into rat neocortex from implantable microfluidic devices.

    abstract::Implantable electrode arrays capable of recording and stimulating neural activity with high spatial and temporal resolution will provide a foundation for future brain computer interface technology. Currently, their clinical impact has been curtailed by a general lack of functional stability, which can be attributed to...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/4/003

    authors: Retterer ST,Smith KL,Bjornsson CS,Turner JN,Isaacson MS,Shain W

    更新日期:2008-12-01 00:00:00

  • Different classification techniques considering brain computer interface applications.

    abstract::In this work the application of different machine learning techniques for classification of mental tasks from electroencephalograph (EEG) signals is investigated. The main application for this research is the improvement of brain computer interface (BCI) systems. For this purpose, Bayesian graphical network, neural ne...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/2/008

    authors: Rezaei S,Tavakolian K,Nasrabadi AM,Setarehdan SK

    更新日期:2006-06-01 00:00:00

  • Online classification of imagined speech using functional near-infrared spectroscopy signals.

    abstract:OBJECTIVE:Most brain-computer interfaces (BCIs) based on functional near-infrared spectroscopy (fNIRS) require that users perform mental tasks such as motor imagery, mental arithmetic, or music imagery to convey a message or to answer simple yes or no questions. These cognitive tasks usually have no direct association ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae4b9

    authors: Rezazadeh Sereshkeh A,Yousefi R,Wong AT,Chau T

    更新日期:2019-02-01 00:00:00

  • Rhythmic modulation of thalamic oscillations depends on intrinsic cellular dynamics.

    abstract:OBJECTIVE:Rhythmic brain stimulation has emerged as a powerful tool to modulate cognition and to target pathological oscillations related to neurological and psychiatric disorders. However, we lack a systematic understanding of how periodic stimulation interacts with endogenous neural activity as a function of the brai...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaeb03

    authors: Li G,Henriquez CS,Fröhlich F

    更新日期:2019-02-01 00:00:00

  • Functional vagotopy in the cervical vagus nerve of the domestic pig: implications for the study of vagus nerve stimulation.

    abstract:OBJECTIVE:Given current clinical interest in vagus nerve stimulation (VNS), there are surprisingly few studies characterizing the anatomy of the vagus nerve in large animal models as it pertains to on-and off-target engagement of local fibers. We sought to address this gap by evaluating vagal anatomy in the pig, whose ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab7ad4

    authors: Settell ML,Pelot NA,Knudsen BE,Dingle AM,McConico AL,Nicolai EN,Trevathan JK,Ezzell JA,Ross EK,Gustafson KJ,Shoffstall AJ,Williams JC,Zeng W,Poore SO,Populin LC,Suminski AJ,Grill WM,Ludwig KA

    更新日期:2020-04-09 00:00:00

  • Neural correlates of speech quality dimensions analyzed using electroencephalography (EEG).

    abstract:OBJECTIVE:By means of subjective psychophysical methods, quality of transmitted speech has been decomposed into three perceptual dimensions named 'discontinuity' (F), 'noisiness' (N) and 'coloration' (C). Previous studies using electroencephalography (EEG) already reported effects of perceived intensity of single quali...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf122

    authors: Uhrig S,Mittag G,Möller S,Voigt-Antons JN

    更新日期:2019-06-01 00:00:00

  • CO2 sensitivity of the complexity of phrenic neurograms in the piglet during early maturation.

    abstract::In this paper, we investigate the influence of hypercapnia on the dynamics of the phrenic neurogram in the piglet in two different age groups: 3-7 days (n = 11) and 10-16 days (n = 9). The phrenic neurogram was recorded from 17 piglets (3-16 days old) during control (40% O(2) with 3-5% end-tidal CO(2)), mild hypercapn...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/2/004

    authors: Akay M

    更新日期:2005-06-01 00:00:00

  • Speech stream segregation to control an ERP-based auditory BCI.

    abstract:OBJECTIVE:The use of natural sounds in auditory Brain-Computer Interfaces (BCI) has been shown to improve classification results and usability. Some auditory BCIs are based on stream segregation, in which the subjects must attend one audio stream and ignore the other(s); these streams include some kind of stimuli to be...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abdd44

    authors: Velasco-Álvarez F,Fernández-Rodríguez Á,Medina-Juliá MT,Ron-Angevin R

    更新日期:2021-01-19 00:00:00

  • Task-dependent signal variations in EEG error-related potentials for brain-computer interfaces.

    abstract:OBJECTIVE:A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user's mental task was independent of the device operation (e.g., the mental task was motor imagery and the...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/2/026024

    authors: Iturrate I,Montesano L,Minguez J

    更新日期:2013-04-01 00:00:00

  • Object stiffness recognition using haptic feedback delivered through transcutaneous proximal nerve stimulation.

    abstract:OBJECTIVE:Haptic feedback is crucial when we manipulate objects. Information pertaining to an object's stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous elec...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab4d99

    authors: Vargas L,Shin H,Huang HH,Zhu Y,Hu X

    更新日期:2019-12-05 00:00:00

  • Dual stream neural networks for brain signal classification.

    abstract::In this paper we propose a dual stream neural network (DSNN) for classifying arbitrary collections of functional neuroimaging signals for the purpose of brain computer interfaces (BCIs). In the DSNN the first stream is an end-to-end classifier taking raw time-dependent signals as input and generating feature identific...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abc903

    authors: Kuang D,Michoski C

    更新日期:2020-11-10 00:00:00

  • Anatomical and technical factors affecting the neural response to epidural spinal cord stimulation.

    abstract:OBJECTIVE:Spinal cord stimulation (SCS) is a common neurostimulation therapy to treat chronic pain. Computational models represent a valuable tool to study the potential mechanisms of action of SCS and to optimize the design and implementation of SCS technologies. However, it is imperative that these computational mode...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8fc4

    authors: Zander HJ,Graham RD,Anaya CJ,Lempka SF

    更新日期:2020-06-12 00:00:00

  • Performance measurement for brain-computer or brain-machine interfaces: a tutorial.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) have the potential to be valuable clinical tools. However, the varied nature of BCIs, combined with the large number of laboratories participating in BCI research, makes uniform performance reporting difficult. To address this situation, we present a tutorial on performance me...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/3/035001

    authors: Thompson DE,Quitadamo LR,Mainardi L,Laghari KU,Gao S,Kindermans PJ,Simeral JD,Fazel-Rezai R,Matteucci M,Falk TH,Bianchi L,Chestek CA,Huggins JE

    更新日期:2014-06-01 00:00:00