Closed-loop regulation of arterial pressure after acute brain death.

Abstract:

:The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is challenging, due to the lack of vasomotor function in BD donors. Closed-loop stabilization therefore has the potential of increasing availability of acceptable donor organs, and serves to indicate feasibility within less demanding patient groups. A dynamic model of nitroglycerine pharmacology, suitable for controller synthesis, was identified from an experiment involving an anesthetized pig, using a gradient-based output error method. The model was used to synthesize a robust PID controller for hypertension prevention, evaluated in a second experiment, on a second, brain dead, pig. Hypotension was simultaneously prevented using closed-loop controlled infusion of noradrenaline, by means of a previously published controller. A linear model of low order, with variable (uncertain) gain, was sufficient to describe the dynamics to be controlled. The robustly tuned PID controller utilized in the second experiment kept the MAP within a user-defined range. The system was able to prevent hypertension, exceeding a reference of 100 mmHg by more than 10%, during 98% of a 12 h experiment. This early work demonstrates feasibility of the investigated modelling and control synthesis approach, for the purpose of maintaining normotension in a porcine BD model. There remains a need to characterize individual variability, in order to ensure robust performance over the expected population.

journal_name

J Clin Monit Comput

authors

Soltesz K,Sjöberg T,Jansson T,Johansson R,Robertsson A,Paskevicius A,Liao Q,Qin G,Steen S

doi

10.1007/s10877-017-0033-z

subject

Has Abstract

pub_date

2018-06-01 00:00:00

pages

429-437

issue

3

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-017-0033-z

journal_volume

32

pub_type

杂志文章
  • A new calibration method that compensates for the effects of O2 and N2 on infrared CO2 analysers.

    abstract:OBJECTIVE:This study evaluates a method for calibrating mainstream CO(2) analysers in which CO(2) partial pressure (P (CO2)) is calculated as a function of the outputs of CO(2) and O(2) analysers. METHODS:Three mass flow controllers were used to generate 25 different reference mixtures of O(2), N(2) and CO(2). Referen...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9005-9

    authors: Tang Y,Turner MJ,Baker AB

    更新日期:2006-04-01 00:00:00

  • Non-invasive cardiac output monitoring by aortic blood flow measurement with the Dynemo 3000.

    abstract::The operating principles and methods for the continuous determination of aortic blood flow (ABF) with the Dynemo 3000 system are described in detail. The system uses a novel transesophageal ultrasonic Echo-Doppler probe simultaneously to measure aortic diameter and blood flow velocity at the same anatomic level, in re...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009902517388

    authors: Boulnois JL,Pechoux T

    更新日期:2000-01-01 00:00:00

  • Application of artificial neural networks as an indicator of awareness with recall during general anaesthesia.

    abstract:OBJECTIVE:Awareness with recall is a rare but serious complication of general anaesthesia with an incidence ranging from 0.1%-0.7%. In the absence of a reliable depth-of-anaesthesia monitor, attempts have been made to predict awareness from intraoperative haemodynamic monitoring data, with little success. Artificial ne...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1015426015547

    authors: Ranta SO,Hynynen M,Räsänen J

    更新日期:2002-01-01 00:00:00

  • Non-invasive electrical cardiometry cardiac output monitoring during prehospital helicopter emergency medical care: a feasibility study.

    abstract:PURPOSE:Introducing advanced hemodynamic monitoring might be beneficial during Helicopter Emergency Medical Service (HEMS) care. However, it should not increase the on-scene-time, it should be easy to use and should be non-invasive. The goal of this study was to investigate the feasibility of non-invasive cardiac outpu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-021-00657-5

    authors: Slagt C,Servaas S,Ketelaars R,van Geffen GJ,Tacken MCT,Verrips CA,Baggen LAM,Scheffer GJ,van Eijk LT

    更新日期:2021-01-23 00:00:00

  • Sympatho-vagal balance, as quantified by ANSindex, predicts post spinal hypotension and vasopressor requirement in parturients undergoing lower segmental cesarean section: a single blinded prospective observational study.

    abstract::Hypotension subsequent to spinal anesthesia occurs in a significant number of parturients undergoing lower segment caesarian section. Currently available methods to predict the incidence of hypotension, its severity and the outcome are sub-optimal. Many workers have used basal heart rate as one of the predictors. But ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9906-9

    authors: Prashanth A,Chakravarthy M,George A,Mayur R,Hosur R,Pargaonkar S

    更新日期:2017-08-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • The influence of basic ventilation strategies on cerebral oxygenation in anesthetized patients without vascular disease.

    abstract:OBJECTIVES:Optimizing cerebral oxygenation is of paramount importance in certain intraoperative situations. There is, however, a paucity of published data pertaining to changes in cerebral oxygenation seen with increases in the inspired fraction of oxygen (FIO2) or end-tidal carbon dioxide (PETCO2) in anesthetized pati...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-010-9265-x

    authors: Picton P,Shanks A,Dorje P,Mashour GA

    更新日期:2010-12-01 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

    abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009990210114

    authors: Tripathi M,Pandey M

    更新日期:2000-01-01 00:00:00

  • Sampling intervals to record severe hypotensive and hypoxic episodes in anesthetised patients.

    abstract:OBJECTIVE:To define the longest sampling interval which will faithfully record the time course of episodes of severe hypotension and hypoxia in anesthetised patients. METHODS:Electronic anesthetic records of 1501 patients were analyzed retrospectively for hypotension where measured systolic blood pressure fell to 60 m...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009978414365

    authors: Derrick JL,Bassin DJ

    更新日期:1998-07-01 00:00:00

  • A system of classification for the clinical applications of capnography.

    abstract::We have attempted to list all the clinical applications of capnography described to date and classify them into categories. From an extensive Pubmed search 46 clinical applications of capnography were listed. To classify these we used six categories- Airway, Breathing, Circulation, Anesthetic Delivery Apparatus, Homeo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-007-9094-8

    authors: Eipe N,Tarshis J

    更新日期:2007-12-01 00:00:00

  • A graphical object display improves anesthesiologists' performance on a simulated diagnostic task.

    abstract:OBJECTIVE:This study tests the hypothesis that a graphical object display (a data display consisting of meaningful shapes) will affect the ability of anesthesiologists to perform a diagnostic task rapidly and correctly. The diagnostic tasks studied were recognition and differentiation of five etiologies of shock--anaph...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009914019889

    authors: Blike GT,Surgenor SD,Whalen K

    更新日期:1999-01-01 00:00:00

  • Capnography to check the safety of Bain circuit.

    abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9212-x

    authors: Kataria S,Subramanyam R

    更新日期:2010-02-01 00:00:00

  • Continuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?

    abstract::Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective s...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9804-6

    authors: Song IK,Lee JH,Kang JE,Park YH,Kim HS,Kim JT

    更新日期:2017-02-01 00:00:00

  • Cardioplegia and ventricular late potentials in cardiac surgical patients.

    abstract:BACKGROUND AND OBJECTIVE:Ventricular late potentials (LP) recording with signal-averaged electrocar- diogram allow identifying patients at risk of sudden death and ventricular tachycardia. Cardiac surgery with cardiopulmonary bypass (CPB) could predispose to the development of myocardial ischemia related to imperfect c...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-011-9305-1

    authors: Schütz N,Romand JA,Yanez ND,Treggiari MM,Bendjelid K

    更新日期:2011-08-01 00:00:00

  • Using EEG to monitor anesthesia drug effects during surgery.

    abstract::The use of processed electroencephalography (EEG) using a simple frontal lead system has been made available for assessing the impact of anesthetic medications during surgery. This review discusses the basic principles behind these devices. The foundations of anesthesia monitoring rest on the observations of Guedel wi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-006-9044-x

    authors: Jameson LC,Sloan TB

    更新日期:2006-12-01 00:00:00

  • Study of light transmission through gauze pad effected by blood or liquids to detect needle dislodgement.

    abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9206-8

    authors: Takeuchi A,Ishida K,Morohoshi Y,Shinbo T,Hirose M,Ikeda N

    更新日期:2010-02-01 00:00:00

  • Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

    abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00481-3

    authors: Al-Halhouli A,Al-Ghussain L,El Bouri S,Liu H,Zheng D

    更新日期:2020-02-22 00:00:00

  • Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

    abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9628-9

    authors: Harms FA,Bodmer SI,Raat NJ,Mik EG

    更新日期:2015-08-01 00:00:00

  • Using physiological models and decision theory for selecting appropriate ventilator settings.

    abstract:OBJECTIVE:To present a decision support system for optimising mechanical ventilation in patients residing in the intensive care unit. METHODS:Mathematical models of oxygen transport, carbon dioxide transport and lung mechanics are combined with penalty functions describing clinical preference toward the goals and side...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-006-9049-5

    authors: Rees SE,Allerød C,Murley D,Zhao Y,Smith BW,Kjaergaard S,Thorgaard P,Andreassen S

    更新日期:2006-12-01 00:00:00

  • The effect of variable arterial transducer level on the accuracy of pulse contour waveform-derived measurements in critically ill patients.

    abstract::We know that a 10 cm departure from the reference level of pressure transducer position is equal to a 7.5 mmHg change of invasive hemodynamic pressure monitoring in a fluid-filled system. However, the relationship between the site level of a variable arterial pressure transducer and the pulse contour-derived parameter...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9756-x

    authors: He HW,Liu DW,Long Y,Wang XT,Zhao ML,Lai XL

    更新日期:2016-10-01 00:00:00

  • Generic and patient-specific models of the arterial tree.

    abstract::Recent advance in imaging modalities used frequently in clinical routine can provide description of the geometrical and hemodynamical properties of the arterial tree in great detail. The combination of such information with models of blood flow of the arterial tree can provide further information, such as details in p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-012-9382-9

    authors: Reymond P,Vardoulis O,Stergiopulos N

    更新日期:2012-10-01 00:00:00

  • The pressure exerted on the tongue during intubation with simultaneous cervical spine immobilisation: a comparison between four videolaryngoscopes and the Macintosh laryngoscope-a manikin study.

    abstract::Excessive pressures exerted on the tongue during intubation may be associated with serious complications and may make intubation more difficult. The aim of this study was to evaluate five different intubating devices in the hands of experienced anaesthetists during simulated conditions of reduced cervical spine mobili...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0095-y

    authors: Aleksandrowicz D,Gaszyński T

    更新日期:2018-10-01 00:00:00

  • Importance of re-calibration time on pulse contour analysis agreement with thermodilution measurements of cardiac output: a retrospective analysis of intensive care unit patients.

    abstract::We assessed the effect of re-calibration time on cardiac output estimation and trending performance in a retrospective analysis of an intensive care unit patient population using error grid analyses. Paired thermodilution and arterial blood pressure waveform measurements (N = 2141) from 222 patient records were extrac...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9749-9

    authors: Scully CG,Gomatam S,Forrest S,Strauss DG

    更新日期:2016-10-01 00:00:00

  • The influence of left lateral position on cardiac output changes after head up tilt measured by impedance cardiography.

    abstract:BACKGROUND:The value of the impedance cardiography (IC) method for measuring cardiac output (CO) with the subject in the left lateral position has not yet been established. We compared the CO after a 30 degrees head-up tilt with the subjects in the supine and left lateral position. METHODS:Thirty healthy young volunte...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009968513512

    authors: Kamenik M

    更新日期:1999-12-01 00:00:00

  • Ventilator-associated pneumonia: current status and future recommendations.

    abstract:OBJECTIVE:Ventilator-associated pneumonia (VAP) is a common hazardous complication in ICU patients. The aim of the current review is to give an update on the current status and future recommendations for VAP prevention. METHODS:This article gives an updated review of the current literature on VAP. The first part brief...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,meta分析,评审

    doi:10.1007/s10877-010-9228-2

    authors: Efrati S,Deutsch I,Antonelli M,Hockey PM,Rozenblum R,Gurman GM

    更新日期:2010-04-01 00:00:00

  • Spinal cord stimulation: principles of past, present and future practice: a review.

    abstract::Electric energy have been in use for the treatment of various ailments, including pain, since the time of Pharaohs. The theoretical basis of electrotherapy of pain was provided by the Gate Control Theory of Melzak and Wall. In 1965, Shealey et al. first introduced electrical stimulation of spinal cord for treating pai...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-009-9201-0

    authors: Kunnumpurath S,Srinivasagopalan R,Vadivelu N

    更新日期:2009-10-01 00:00:00

  • Utility of near infrared light to determine tissue oxygenation during hepato-biliary surgery.

    abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9642-y

    authors: Murphy N,Fröhlich S,Kong T,Boylan JF,Conlon N

    更新日期:2015-10-01 00:00:00

  • Trending algorithm discriminates hemodynamic from injury related TcMEP amplitude loss.

    abstract::Jasiukaitis and Lyon (J Clin Monit Comput, https://doi.org/10.1007/s10877-018-0181-9, 2018) described an motor evoked potential (MEP)amplitude trending system to detect MEP amplitude loss against a background of MEP variability. They found that the end of case value of a running R2 triggered by a set MEP amplitude los...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00272-5

    authors: Jasiukaitis P,Lyon R

    更新日期:2020-02-01 00:00:00

  • Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.

    abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00436-3

    authors: Cammarota G,Verdina F,Santangelo E,Lauro G,Boniolo E,Tarquini R,Spinelli E,Zanoni M,Garofalo E,Bruni A,Pesenti A,Della Corte F,Navalesi P,Vaschetto R,Mauri T

    更新日期:2020-12-01 00:00:00