Perforation of the inferior vena cava with aortic and vertebral penetration by a suprarenal Greenfield filter.

Abstract:

:Various complications have been reported after insertion of the Greenfield filter. This report describes an unusual complication after suprarenal placement of this filter: spreading of the filter struts, with perforation of the inferior vena cava, and penetration of the aorta and a vertebral body, followed by fracture of one of the struts.

journal_name

Radiology

journal_title

Radiology

authors

Kim D,Porter DH,Siegel JB,Simon M

doi

10.1148/radiology.172.3.2772180

subject

Has Abstract

pub_date

1989-09-01 00:00:00

pages

721-3

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

172

pub_type

杂志文章
  • Treated thymic lymphoma: comparison of MR imaging with CT.

    abstract:PURPOSE:To determine the appearance of treated thymic lymphoma at magnetic resonance (MR) imaging and to compare the results with findings from posttherapy computed tomography (CT) and clinical outcome. MATERIALS AND METHODS:MR images and CT scans in 25 patients with thymic lymphoma were reviewed. Dimensions of residu...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.2.9114090

    authors: Spiers AS,Husband JE,MacVicar AD

    更新日期:1997-05-01 00:00:00

  • Heterogeneity in the campomelic syndromes. Long-and short-bone varieties.

    abstract::Analysis of 9 cases of bilateral bent limbs (campomelia) and dwarfism, as well as a review of the literature, indicate that campomelic syndrome appears to be a well-defined distinct disorder which the authors call long-limbed campomelic syndrome. Other neonates with congenital bent-limbed dwarfism can be classified as...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.3.641

    authors: Khajavi A,Lachman R,Rimoin D,Schimke RN,Dorst J,Handmaker S,Ebbin A,Perreault G

    更新日期:1976-09-01 00:00:00

  • Movable core guide wire: evaluation of improved model.

    abstract::Six commercially available movable core guide wires were compared with each other and with a new design in glass models simulating tortuous vessels. The results demonstrate a wide variability in performance of the commercially available wires and the superiority of the new design. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.2.3961190

    authors: Smith TP,Derauf BJ,Darcy MD,Hunter DW,Castaneda-Zuniga WR,Amplatz K

    更新日期:1986-05-01 00:00:00

  • Lymphocytic adenohypophysitis: contrast-enhanced MR imaging in five cases.

    abstract:PURPOSE:To describe observations of adenohypophysitis on magnetic resonance (MR) images. MATERIALS AND METHODS:Clinical, enhanced MR imaging, surgical, and histologic findings were retrospectively studied in four female patients and one male patient with adenohypophysitis who presented with headaches, pituitary insuff...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.1.7892490

    authors: Ahmadi J,Meyers GS,Segall HD,Sharma OP,Hinton DR

    更新日期:1995-04-01 00:00:00

  • Recurrent deep venous thrombosis: limitations of US.

    abstract::Compression ultrasound (US) has become widely used to diagnose acute deep venous thrombosis (DVT). To determine the appearance of veins with previous DVT, 60 legs (58 patients) in which DVT had been diagnosed 6-31 months earlier (mean, 15.1 months) were reexamined with compression US. At reevaluation there was no indi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.3.2644660

    authors: Cronan JJ,Leen V

    更新日期:1989-03-01 00:00:00

  • Hypochondroplasia: clinical and radiological aspects in 39 cases.

    abstract::A retrospective review of 39 cases of hypochondroplasia revealed consistent but variable degrees of clinical and radiological features sufficient to allow differentiation from other well-established metaphyseal chondrodysplasias. Macrocephaly was noted in approximately half the cases. This contradicts a finding of nor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.1.95

    authors: Hall BD,Spranger J

    更新日期:1979-10-01 00:00:00

  • Amplitude-modulated continuous arterial spin-labeling 3.0-T perfusion MR imaging with a single coil: feasibility study.

    abstract::Written informed consent was obtained prior to all human studies after the institutional review board approved the protocol. A continuous arterial spin-labeling technique with an amplitude-modulated control was implemented by using a single coil at 3.0 T. Adiabatic inversion efficiency at 3.0 T, comparable to that at ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2351031663

    authors: Wang J,Zhang Y,Wolf RL,Roc AC,Alsop DC,Detre JA

    更新日期:2005-04-01 00:00:00

  • Thrombus in the left atrial appendage in stroke patients: detection with cardiac CT angiography--a preliminary report.

    abstract:PURPOSE:To assess the diagnostic performance of 64-section cardiac computed tomographic (CT) angiography for detection of left atrial appendage (LAA) thrombi in stroke patients by using transesophageal echocardiography (TEE) as the reference standard. MATERIALS AND METHODS:This study was approved by the institutional ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2491071544

    authors: Hur J,Kim YJ,Nam JE,Choe KO,Choi EY,Shim CY,Choi BW

    更新日期:2008-10-01 00:00:00

  • Women with breast cancer: histologic findings in the contralateral breast.

    abstract:PURPOSE:To investigate contralateral breast biopsy histologic findings in women with breast cancer. MATERIALS AND METHODS:Histologic findings in 237 patients with breast cancer who underwent contralateral breast biopsy for clinically or mammographically detected abnormalities were retrospectively reviewed. Malignant f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.203.3.9169690

    authors: Roubidoux MA,Helvie MA,Wilson TE,Lai NE,Paramagul C

    更新日期:1997-06-01 00:00:00

  • Dual mechanisms for change in myocardial signal intensity by means of a single MR contrast medium: dependence on concentration and pulse sequence.

    abstract::To determine whether gadodiamide injection can provide sufficient enhancement on both T1- and T2-weighted spin-echo magnetic resonance (MR) images of the heart and skeletal muscles, anesthetized rats were divided into five groups. Groups 1-3 received 0.1 (n = 9), 0.3 (n = 8), or 0.5 (n = 8) mmol/kg gadodiamide injecti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.186.1.8416560

    authors: Saeed M,Wendland MF,Masui T,Yu KK,Li JJ,Derugin N,Higgins CB

    更新日期:1993-01-01 00:00:00

  • Comparison of the Reliability of Acoustic Radiation Force Impulse Imaging and Supersonic Shear Imaging in Measurement of Liver Stiffness.

    abstract:PURPOSE:To compare the reliability of acoustic radiation force impulse (ARFI) imaging and supersonic shear imaging (SSI) in measurement of liver stiffness. MATERIALS AND METHODS:This study was approved by the institutional review board, and written informed consent was obtained for all patients. Seventy-nine patients ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015141975

    authors: Woo H,Lee JY,Yoon JH,Kim W,Cho B,Choi BI

    更新日期:2015-12-01 00:00:00

  • Use of a gradient intensifying screen for scoliosis radiography.

    abstract::A gradient intensifying screen composed of rare earth phosphors and calcium tungstate was developed. It provides uniform film density when there is a graded increase in subject density. Use of this screen for scoliosis radiography provides an improved image and reduces radiation exposure. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.1.7360970

    authors: Ritter EM,Wright CE,Fritz SL,Kirchmer NA,De Smet AA

    更新日期:1980-04-01 00:00:00

  • Liver anatomy applied to the placement of transjugular intrahepatic portosystemic shunts.

    abstract:PURPOSE:To study the vascular and biliary liver anatomy and its relevance to the creation of a transjugular intrahepatic portosystemic shunt (TIPS). MATERIALS AND METHODS:Acrylic casts of 25 normal human livers (necropsy specimens) were obtained. The anatomy of the hepatic veins, portal vein, hepatic artery, and bile ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.191.3.8184050

    authors: Uflacker R,Reichert P,D'Albuquerque LC,de Oliveira e Silva A

    更新日期:1994-06-01 00:00:00

  • Radiographic manifestations of lymph node involvement in amyloidosis.

    abstract::The radiographic demonstration of lymph node involvement in amyloidosis is rare. Of 12 previously reported cases with lymph node enlargement, two also showed calcified nodes. This paper presents two new cases, one of which illustrates previously unreported findings. Recent advances that help to explain the pathogenesi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.138.1.7455070

    authors: Gross BH

    更新日期:1981-01-01 00:00:00

  • Conventional Autopsy versus Minimally Invasive Autopsy with Postmortem MRI, CT, and CT-guided Biopsy: Comparison of Diagnostic Performance.

    abstract::Purpose To compare the diagnostic performance of minimally invasive autopsy with that of conventional autopsy. Materials and Methods For this prospective, single-center, cross-sectional study in an academic hospital, 295 of 2197 adult cadavers (mean age: 65 years [range, 18-99 years]; age range of male cadavers: 18-99...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180924

    authors: Blokker BM,Weustink AC,Wagensveld IM,von der Thüsen JH,Pezzato A,Dammers R,Bakker J,Renken NS,den Bakker MA,van Kemenade FJ,Krestin GP,Hunink MGM,Oosterhuis JW

    更新日期:2018-12-01 00:00:00

  • Portal-systemic encephalopathy: presence of basal ganglia lesions with high signal intensity on MR images.

    abstract::Sixteen patients with cirrhosis of the liver underwent cranial magnetic resonance (MR) imaging and transarterial portography to evaluate the relationship between basal ganglia lesions and portal-systemic collateral vessels. No neuropsychiatric disturbance was observed in any of the patients at the time of the MR exami...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014310

    authors: Inoue E,Hori S,Narumi Y,Fujita M,Kuriyama K,Kadota T,Kuroda C

    更新日期:1991-05-01 00:00:00

  • Focal liver tumors: characterization with 3D perflubutane microbubble contrast agent-enhanced US versus 3D contrast-enhanced multidetector CT.

    abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2511081324

    authors: Luo W,Numata K,Morimoto M,Kondo M,Takebayashi S,Okada M,Morita S,Tanaka K

    更新日期:2009-04-01 00:00:00

  • White Matter by Diffusion MRI Following Methylphenidate Treatment: A Randomized Control Trial in Males with Attention-Deficit/Hyperactivity Disorder.

    abstract::BackgroundMethylphenidate (MPH) is highly effective in treating attention-deficit/hyperactivity disorder (ADHD). However, not much is known about its effect on the development of human brain white matter (WM).PurposeTo determine whether MPH modulates WM microstructure in an age-dependent fashion in a randomized double...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.2019182528

    authors: Bouziane C,Filatova OG,Schrantee A,Caan MWA,Vos FM,Reneman L

    更新日期:2019-10-01 00:00:00

  • Evaluation of times of maximal involvement for early skin reactions following x irradiation combined with hyperthermic treatment.

    abstract::Times of maximal involvement in mouse skin were determined for reactions produced by graded doses of x irradiation combined with hyperthermic treatment at 37.5, 41, 42, 42.5 and 43 degrees C for one hour. The times of maximal involvement in each case were found to be independent of thermal treatment. These data provid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.2.475

    authors: Leith JT

    更新日期:1976-05-01 00:00:00

  • Distinguishing adrenal adenomas from nonadenomas: combined use of diagnostic parameters of unenhanced and short 5-minute dynamic enhanced CT protocol.

    abstract:PURPOSE:To retrospectively examine the diagnostic values of individual parameters obtained from unenhanced and 35-second and 5-minute contrast material-enhanced (enhanced) computed tomography (CT) in distinguishing adenomas, particularly lipid-poor adenomas, from nonadenomas and to determine the best diagnostic method ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2502080302

    authors: Kamiyama T,Fukukura Y,Yoneyama T,Takumi K,Nakajo M

    更新日期:2009-02-01 00:00:00

  • Cavernous hemangiomas of the spinal cord: MR imaging.

    abstract::In three patients with histologically proved cavernous hemangiomas of the spinal cord, magnetic resonance (MR) imaging was superior to myelography, delayed computed tomography (CT) myelography, and contrast-enhanced CT in depicting the lesion. The presence of mixed subacute and chronic hemorrhage, suggested by mixed h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.166.3.3340780

    authors: Fontaine S,Melanson D,Cosgrove R,Bertrand G

    更新日期:1988-03-01 00:00:00

  • CT colonography: automated measurement of colonic polyps compared with manual techniques--human in vitro study.

    abstract:PURPOSE:To prospectively investigate the relative accuracy and reproducibility of manual and automated computer software measurements by using polyps of known size in a human colectomy specimen. MATERIALS AND METHODS:Institutional review board approval was obtained for the study; written consent for use of the surgica...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2421052068

    authors: Taylor SA,Slater A,Halligan S,Honeyfield L,Roddie ME,Demeshski J,Amin H,Burling D

    更新日期:2007-01-01 00:00:00

  • Sonoelastography of the Common Flexor Tendon of the Elbow with Histologic Agreement: A Cadaveric Study.

    abstract::Purpose To determine the correlation of the results of conventional B-mode ultrasonography (US) and compression sonoelastography with histologic results in common flexor tendons of the elbow in human cadavers. Materials and Methods Twenty-five common flexor tendons were evaluated in 16 fresh, unembalmed cadavers of 11...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160139

    authors: Klauser AS,Pamminger MJ,Halpern EJ,Abd Ellah MMH,Moriggl B,Taljanovic MS,Deml C,Sztankay J,Klima G,Gruber L,Jaschke WR

    更新日期:2017-05-01 00:00:00

  • Hepatocellular carcinoma: MR imaging findings in cirrhotic livers and noncirrhotic livers.

    abstract:PURPOSE:To compare the magnetic resonance (MR) imaging findings of primary hepatocellular carcinoma (HCC) in cirrhotic versus noncirrhotic livers. MATERIALS AND METHODS:MR images in 36 patients with HCC (30 men and she women aged 42-84 years [mean age, 65 years]) were retrospectively reviewed. The number and size of h...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.1.r99ja1975

    authors: Winston CB,Schwartz LH,Fong Y,Blumgart LH,Panicek DM

    更新日期:1999-01-01 00:00:00

  • Cervical spine: three-dimensional MR imaging with magnetization transfer prepulsed turbo field echo techniques.

    abstract::In 11 volunteers, magnetic resonance (MR) imaging of the cervical spine was performed with a magnetization transfer preparatory pulse (prepulsed), three-dimensional Fourier transform, turbo field echo sequence. The effects of flip angle, number of shots, phase-encoding profile order, and magnetization transfer prepuls...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.207.3.9609910

    authors: Melhem ER,Caruthers SD,Jara H

    更新日期:1998-06-01 00:00:00

  • Capsular transgression of prostatic carcinoma: evaluation with transrectal US with pathologic correlation.

    abstract::One hundred twenty-five patients with biopsy proved clinical stage A or B prostatic carcinoma were evaluated with biplane transrectal ultrasonography (US) prior to radical prostatectomy. Sonograms were evaluated for capsular transgression of the tumor into the posterior and posterolateral aspects of the glands as mani...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.178.3.1994420

    authors: Hamper UM,Sheth S,Walsh PC,Holtz PM,Epstein JI

    更新日期:1991-03-01 00:00:00

  • Bronchioloalveolar carcinoma: focal area of ground-glass attenuation at thin-section CT as an early sign.

    abstract:PURPOSE:To assess an early thin-section computed tomographic (CT) finding of the localized formation of bronchioloalveolar carcinoma (BAC). MATERIALS AND METHODS:From October 1994 to September 1995, four consecutive patients with biopsy-proved BAC were studied. Thin-section CT (n=4), radiographic (n=4), pathologic (n=...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.199.2.8668800

    authors: Jang HJ,Lee KS,Kwon OJ,Rhee CH,Shim YM,Han J

    更新日期:1996-05-01 00:00:00

  • Liver fibrosis in chronic hepatitis C virus infection: differentiating minimal from intermediate fibrosis with perfusion CT.

    abstract:PURPOSE:To prospectively assess the utility of perfusion computed tomography (CT) for differentiating minimal from intermediate fibrosis in treatment-naïve patients with chronic hepatitis C virus (HCV) infection. MATERIALS AND METHODS:This study was approved by the Institutional Review Board, and informed consent was ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10091295

    authors: Ronot M,Asselah T,Paradis V,Michoux N,Dorvillius M,Baron G,Marcellin P,Van Beers BE,Vilgrain V

    更新日期:2010-07-01 00:00:00

  • Cytotoxic and radiosensitizing effects of 5-thio-D-glucose on hypoxic cells.

    abstract::The effect of 5-thio-D-glucose on the viability and radiosensitivity of P815-X2 mouse mastocytoma cells was studied in vitro. By itself, this compound is specifically cytotoxic toward hypoxic cells; moreover, it sensitizes hypoxic cells to irradiation while it protects aerobic cells from radiation damage. These featur...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.1.201

    authors: Song CW,Clement JJ,Levitt SH

    更新日期:1977-04-01 00:00:00

  • CT of pancreatic islet cell tumors.

    abstract::In 41 patients with clinical evidence of pancreatic islet cell tumors, CT detected 21 of 27 tumors that were proved at surgery (sensitivity 78%) and correctly excluded the diagnosis in 14 of 14 patients with no evidence of tumor at long-term follow-up. Using rapid sequence CT scanning and bolus contrast material infus...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.150.2.6318260

    authors: Stark DD,Moss AA,Goldberg HI,Deveney CW

    更新日期:1984-02-01 00:00:00