Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature.

Abstract:

PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a better therapeutic option due to high radiation dose concentration to the tumor with rapid dose fall-off resulting in normal tissues sparing. The aim of this review was to evaluate the local control, toxicity, and cosmetic outcomes in NMSC treated with high-dose-rate BT (HDR-BT). MATERIAL AND METHODS:In May 2016, a systematic search of bibliographic database of PubMed, Web of Science, Scopus, and Cochrane Library with a combination of key words of "skin cancer", "high dose rate brachytherapy", "squamous cell carcinoma", "basal cell carcinoma", and "non melanoma skin cancer" was performed. In this systematic review, we included randomized trials, non-randomized trials, prospective and retrospective studies in patients affected by NMSC treated with HDR-BT. RESULTS:Our searches generated a total of 85 results, and through a process of screening, 10 publications were selected for the review. Brachytherapy was well tolerated with acceptable toxicity and high local control rates (median: 97%). Cosmetic outcome was reported in seven study and consisted in an excellent and good cosmetic results in 94.8% of cases. CONCLUSIONS:Based on the review data, we can conclude that the treatment of NMSC with HDR-BT is effective with excellent and good cosmetics results, even in elderly patients. The hypofractionated course appears effective with very good local disease control. More data with large-scale randomized controlled trials are needed to assess the efficacy and safety of brachytherapy.

authors

Delishaj D,Rembielak A,Manfredi B,Ursino S,Pasqualetti F,Laliscia C,Orlandi F,Morganti R,Fabrini MG,Paiar F

doi

10.5114/jcb.2016.64112

subject

Has Abstract

pub_date

2016-12-01 00:00:00

pages

533-540

issue

6

eissn

1689-832X

issn

2081-2841

pii

28857

journal_volume

8

pub_type

杂志文章,评审
  • Does supplemental external beam radiation therapy impact urinary, bowel, and erectile function following permanent prostate brachytherapy?: results of two prospective randomized trials.

    abstract:Purpose:To evaluate the impact of supplemental external beam radiation therapy (EBRT) prior to permanent prostate brachytherapy on long term urinary, bowel, and erectile function. Material and methods:Patient administered urinary, bowel, and erectile quality of life (QoL) instrument were obtained prior to treatment an...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.70763

    authors: Merrick GS,Tennant A,Wallner KE,Galbreath R,Butler WM,Fiano R,Adamovich E

    更新日期:2017-10-01 00:00:00

  • Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology.

    abstract:PURPOSE:Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS:Three brachytherapy patients with unique clinical needs we...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.60679

    authors: Sethi R,Cunha A,Mellis K,Siauw T,Diederich C,Pouliot J,Hsu IC

    更新日期:2016-06-01 00:00:00

  • Non-melanoma skin cancer treated with high-dose-rate brachytherapy and Valencia applicator in elderly patients: a retrospective case series.

    abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. Basal cell carcinoma and squamous cell carcinoma are the two most common subtypes of NMSC. The aim of this study was to estimate tumour control, toxicity, and aesthetic events in elderly patients treated with high-dose-...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.55746

    authors: Delishaj D,Laliscia C,Manfredi B,Ursino S,Pasqualetti F,Lombardo E,Perrone F,Morganti R,Paiar F,Fabrini MG

    更新日期:2015-12-01 00:00:00

  • Image fusion techniques in permanent seed implantation.

    abstract::Over the last twenty years major software and hardware developments in brachytherapy treatment planning, intraoperative navigation and dose delivery have been made. Image-guided brachytherapy has emerged as the ultimate conformal radiation therapy, allowing precise dose deposition on small volumes under direct image v...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2010.16920

    authors: Polo A

    更新日期:2010-09-01 00:00:00

  • Comparison of post-implant dosimetrics between intraoperatively built custom-linked seeds and loose seeds by sector analysis at 24 hours and 1 month for localized prostate cancer.

    abstract:Purpose:To compare post-implant dosimetrics between intraoperatively built custom-linked (IBCL) seeds and loose seeds (LS) at 24 hours and 1 month by sector analysis, and to evaluate the effect of IBCL seeds with regard to change in dosimetric parameters, in patients with prostate cancer treated with brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.98110

    authors: Okazaki E,Kuratsukuri K,Nishikawa T,Tanaka T,Sakagami M,Shibuya K

    更新日期:2020-08-01 00:00:00

  • Dosimetric comparison of graphical optimization and inverse planning simulated annealing for brachytherapy of cervical cancer.

    abstract:Purpose:Graphical optimization (GO) and inverse planning simulated annealing (IPSA) are the main treatment planning optimization techniques used in patients undergoing 3D brachytherapy treatment. This study aims to compare the dosimetric difference of plans optimized by GO and IPSA in cervical cancer brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.87145

    authors: Tang B,Liu X,Wang X,Kang S,Wang P,Li J,Orlandini LC

    更新日期:2019-08-01 00:00:00

  • Multisector dosimetry in the immediate post-implant period: significant under dosage of the prostate base.

    abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.42023

    authors: Kirschner AN,Sathiaseelan V,Zhang Y,David J,Kalapurakal JA

    更新日期:2014-03-01 00:00:00

  • Patterns of cervical cancer brachytherapy in India: results of an online survey supported by the Indian Brachytherapy Society.

    abstract:Purpose:Cervical cancer is the most common gynecological cancer in India. Uniform protocol-based treatment is important for achieving optimal outcomes. We undertook a survey to investigate patterns of care with special regard to patterns of care in cervical cancer brachytherapy in India. Material and methods:A 17-ques...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.90448

    authors: Chatterjee A,Grover S,Gurram L,Sastri S,Mahantshetty U

    更新日期:2019-12-01 00:00:00

  • Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    abstract:PURPOSE:To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. MATERIAL AND METHODS:Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultr...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.69807

    authors: Kawakami S,Ishiyama H,Satoh T,Tsumura H,Sekiguchi A,Takenaka K,Tabata KI,Iwamura M,Hayakawa K

    更新日期:2017-08-01 00:00:00

  • Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer - a South Indian institutional experience.

    abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.55115

    authors: Rao PB,Ghosh S

    更新日期:2015-10-01 00:00:00

  • A case report of ultrasound-guided interstitial brachytherapy for abdominal wall metastases of ovarian cancer.

    abstract:PURPOSE:To report the treatment effect of interstitial brachytherapy for abdominal wall metastases of ovarian cancer. MATERIAL AND METHODS:The patient is a 44-year-old female with a diagnosis of stage IA ovarian cancer. After surgery and two cycles of chemotherapy with paclitaxel and carboplatin, the patient noticed d...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2015.48574

    authors: Shi D,Wu N,Zhao H,He M,Han D,Cheng G

    更新日期:2015-02-01 00:00:00

  • An evaluation of the robustness of organ-at-risk recommendations made by GEC/ESTRO according to interobserver variability: a single-center experience.

    abstract:PURPOSE:Groupe Européen de Curiethérapie (GEC) and European Society for Radiotherapy & Oncology (ESTRO) has proposed a rectal dose constraint of the most exposed 2-cc volume (D2cc of ≤ 75 Gy EQD2α/β = 3) during external-beam plus high-dose-rate brachytherapy (HDR-BT) in localized prostate cancer patients. This study ai...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.61738

    authors: Chicas-Sett R,Celada-Alvarez F,Roldán S,Torregrosa A,Betancourt J,Bautista-Ballesteros J,Farga D,Ibañez B,Tormo A,Perez-Calatayud J

    更新日期:2016-08-01 00:00:00

  • Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer.

    abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.72581

    authors: Akiyama H,Major T,Polgár C,Takácsi-Nagy Z

    更新日期:2017-12-01 00:00:00

  • High-dose-rate interstitial brachytherapy with hypoxic radiosensitizer KORTUC II for unresectable pelvic sidewall recurrence of uterine cervical cancer: a case report.

    abstract::In order to improve oncologic outcomes in radiotherapy treatments of patients with unresectable pelvic sidewall recurrences of uterine cervical cancer, we combined high-dose-rate interstitial brachytherapy (HDR-ISBT) with newly tested hypoxic radiosensitizer Kochi oxydol-radiation therapy for unresectable carcinomas (...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.101695

    authors: Nakata M,Yoshida K,Shimbo T,Yoshikawa N,Yoshioka H,Hori A,Sato C,Uesugi Y,Kogata Y,Masui K,Murakami N,Kashihara T,Akiyama H,Tselis N,Ohmichi M,Nihei K

    更新日期:2020-12-01 00:00:00

  • Time to PSA rise differentiates the PSA bounce after HDR and LDR brachytherapy of prostate cancer.

    abstract:Purpose:To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Materials and methods:Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.73786

    authors: Burchardt W,Skowronek J

    更新日期:2018-02-01 00:00:00

  • High-dose-rate interstitial brachytherapy in head and neck cancer: do we need a look back into a forgotten art - a single institute experience.

    abstract:PURPOSE:To evaluate the treatment outcomes with high-dose-rate (HDR) interstitial brachytherapy (HDR-BRT) in head and neck cancers (HNC). MATERIAL AND METHODS:Fifty-eight patients with HNC as per American Joint Committee on Cancer (AJCC) TNM staging criteria were analyzed retrospectively between 2008 and 2015. Forty-t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.67147

    authors: Bhalavat R,Chandra M,Pareek V,Nellore L,George K,Nandakumar P,Bauskar P

    更新日期:2017-04-01 00:00:00

  • Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources.

    abstract:PURPOSE:The aim of this work was to determine dose distributions for high-energy brachytherapy sources at spatial locations not included in the radial dose function gL(r) and 2D anisotropy function F(r,θ) table entries for radial distance r and polar angle θ. The objectives of this study are as follows: 1) to evaluate ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.13715

    authors: Pujades-Claumarchirant MC,Granero D,Perez-Calatayud J,Ballester F,Melhus C,Rivard M

    更新日期:2010-03-01 00:00:00

  • EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG (60)Co HDR brachytherapy source.

    abstract:PURPOSE:The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV). MATERIAL AND METHODS:The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters. EGSn...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.37419

    authors: Anwarul IM,Akramuzzaman MM,Zakaria GA

    更新日期:2013-09-01 00:00:00

  • A comparative study of two reconstructive methods and different recommendations in intracavitary brachytherapy.

    abstract:PURPOSE:Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment pla...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.19498

    authors: Sresty NM,Ramanjappa T,Rao CR,Raju AK,Muralidhar KR

    更新日期:2010-12-01 00:00:00

  • The impact of activating source dwell positions outside the CTV on the dose to treated normal tissue volumes in TRUS guided 3D conformal interstitial HDR brachytherapy of prostate cancer.

    abstract:PURPOSE:Dose coverage is crucial for successful treatment in mono-brachytherapy. Since few and very high dose fractions are used, there is an important balance between dwell positioning outside the clinical target volume (CTV) and possible damage on adjacent normal tissue. The purpose of this study was to evaluate the ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.45586

    authors: Karlsson L,Thunberg P,Johansson B,Persliden J

    更新日期:2014-10-01 00:00:00

  • Hypofractionated external beam radiation therapy in combination with HDR boost for localized prostate cancer: patient reported quality of life outcomes.

    abstract:Purpose:There is limited data to support the use of hypofractionated external beam radiation (HypoF) in combination with high-dose-rate brachytherapy (HDR). We report our quality of life (QOL) outcomes when treating intermediate and high-risk prostate cancer patients with external beam radiation (EBRT) plus HDR. Mater...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.76980

    authors: Morgan TM,Press RH,Cutrell PK,Zhang C,Chen Z,Rahnema S,Jhaveri J,Sanda M,Pattaras J,Patel P,Jani AB,Rossi PJ

    更新日期:2018-06-01 00:00:00

  • Pain relief procedures before high-dose-rate brachytherapy for non-surgical treatment of cervix cancer.

    abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2018.81027

    authors: Pellizzon ACA

    更新日期:2018-12-01 00:00:00

  • The use of nomograms in LDR-HDR prostate brachytherapy.

    abstract:PURPOSE:The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2011.24817

    authors: Pujades MC,Camacho C,Perez-Calatayud J,Richart J,Gimeno J,Lliso F,Carmona V,Ballester F,Crispín V,Rodríguez S,Tormo A

    更新日期:2011-09-01 00:00:00

  • Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer.

    abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.86298

    authors: Walsh A,Hubley E,Doyle L,Cognetti D,Curry J,Bar-Ad V,Luginbuhl A

    更新日期:2019-06-01 00:00:00

  • Locally advanced squamous cell cervical cancer in a patient with septate uterus.

    abstract::A 33-year-old premenopausal multiparous woman with the history of septate uterus was referred to the hospital with menorrhagia and inter-menstrual bleeding occurring for the last 6 months. Work-up revealed a stage IIB cervical cancer. The patient underwent curative chemo/radiotherapy. The patient's septate uterus pres...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2017.70996

    authors: Yavas G,Yavas C,Inan G

    更新日期:2017-10-01 00:00:00

  • HDR brachytherapy (HDR-BT) combined with stent placement in palliative treatment of esophageal cancer.

    abstract:PURPOSE:In the study we present the initial results of palliative treatment using combined methods of HDR-BT and stent insertion in patients with advanced esophagus cancer. MATERIAL AND METHODS:Fifty patients were treated in the Great Poland Cancer Center using HDR-BT between June 2001 and December 2005 and they were ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:

    authors: Kanikowski M,Skowronek J,Kubaszewska M,Chichel A,Piotrowski T

    更新日期:2009-03-01 00:00:00

  • Dosimetry verification of 3D-printed individual template based on CT-MRI fusion for radioactive 125I seed implantation in recurrent high-grade gliomas.

    abstract:Purpose:To verify the accuracy and efficacy of three-dimensional printing individual template (3D-PIT) with computed tomography-magnetic resonance imaging (CT-MRI) fusion for radioactive iodine-125 (125I) seed implantation in high-grade brain gliomas. Material and methods:Between June 2017 and June 2018, 16 patients w...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.85729

    authors: Liu S,Wang H,Wang C,Zhang H,Li W,Dong Q,Hu X

    更新日期:2019-06-01 00:00:00

  • MRI assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: preliminary results of a prospective study.

    abstract:PURPOSE:To report on preliminary results of a prospective study on MRI-assisted cervix cancer brachytherapy pre-planning. MATERIAL AND METHODS:In six locally advanced cervix cancer patients, five days before the first brachytherapy fraction, tandem & ring applicator was inserted under para-cervical anaesthesia, MRI pe...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:

    authors: Petric P,Hudej R,Music M

    更新日期:2009-10-01 00:00:00

  • The role of interstitial brachytherapy in the management of primary radiation therapy for uterine cervical cancer.

    abstract:PURPOSE:The aim of this study was to report the clinical results of uterine cervical cancer patients treated by primary radiation therapy including brachytherapy, and investigate the role of interstitial brachytherapy (ISBT). MATERIAL AND METHODS:All consecutive uterine cervical cancer patients who were treated by pri...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.62938

    authors: Murakami N,Kobayashi K,Kato T,Nakamura S,Wakita A,Okamoto H,Shima S,Tsuchida K,Kashihara T,Harada K,Takahashi K,Umezawa R,Inaba K,Ito Y,Igaki H,Itami J

    更新日期:2016-10-01 00:00:00

  • A comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer.

    abstract:PURPOSE:During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Flet...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.32555

    authors: Basu B,Basu S,Chakraborti B,Ghorai S,Gupta P,Ghosh S,Ghosh K,Jayanti J

    更新日期:2012-12-01 00:00:00