Recent advances of liquid chromatography-(tandem) mass spectrometry in clinical and forensic toxicology - An update.

Abstract:

:Liquid chromatography (LC) coupled to mass spectrometry (MS) or tandem mass spectrometry (MS/MS) is a well-established and widely used technique in clinical and forensic toxicology as well as doping control especially for quantitative analysis. In recent years, many applications for so-called multi-target screening and/or quantification of drugs, poisons, and or their metabolites in biological matrices have been developed. Such methods have proven particularly useful for analysis of so-called new psychoactive substances that have appeared on recreational drug markets throughout the world. Moreover, the evolvement of high resolution MS techniques and the development of data-independent detection modes have opened new possibilities for applications of LC-(MS/MS) in systematic toxicological screening analysis in the so called general unknown setting. The present paper will provide an overview and discuss these recent developments focusing on the literature published after 2010.

journal_name

Clin Biochem

journal_title

Clinical biochemistry

authors

Remane D,Wissenbach DK,Peters FT

doi

10.1016/j.clinbiochem.2016.07.010

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

1051-71

issue

13-14

eissn

0009-9120

issn

1873-2933

pii

S0009-9120(16)30167-9

journal_volume

49

pub_type

杂志文章,评审
  • Monitoring of dipeptidyl peptidase-IV (DPP-IV) activity in patients with mucopolysaccharidoses types I and II on enzyme replacement therapy - Results of a pilot study.

    abstract:OBJECTIVES:Mucopolysaccharidoses (MPSs) are a group of rare, inherited metabolic disorders which result from the lack of one of the lysosomal enzymes responsible for the degradation of glycosaminoglycans. Early recognition of MPS is important as it enables prompt implementation of enzyme replacement therapy (ERT). Dipe...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2015.11.011

    authors: Hetmańczyk K,Bednarska-Makaruk M,Kierus K,Murawska-Izdebska S,Piekutowska-Abramczuk D,Pilch B,Tylki-Szymańska A,Ługowska A

    更新日期:2016-04-01 00:00:00

  • Problems with the estimation of urine protein by automated assays.

    abstract:OBJECTIVES:Most clinical laboratories replaced their manual precipitation techniques for the determination of urinary protein with automated dye binding assays or benzethonium chloride-turbidimetric assays. Few studies have validated these assays for the measurement of urinary proteins in the normal range. DESIGN AND ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2004.12.010

    authors: Dube J,Girouard J,Leclerc P,Douville P

    更新日期:2005-05-01 00:00:00

  • Continuous reference intervals for 38 biochemical markers in healthy children and adolescents: Comparisons to traditionally partitioned reference intervals.

    abstract:BACKGROUND:Reference intervals have traditionally been partitioned by age based on statistical significance and physiological relevance. However, analyte concentration does not change abruptly with age, but rather dynamically. In this study, we establish biochemical marker continuous reference intervals for a Canadian ...

    journal_title:Clinical biochemistry

    pub_type: 临床试验,杂志文章

    doi:10.1016/j.clinbiochem.2019.08.010

    authors: Asgari S,Higgins V,McCudden C,Adeli K

    更新日期:2019-11-01 00:00:00

  • Enzyme linked lectin assay (ELLA) for direct analysis of transferrin sialylation in serum samples.

    abstract:OBJECTIVES:Glycosylation analysis provides many opportunities for diagnostics, but its complexity hampers its routine application. Aiming to alleviate this problem, we developed a simple assay that can measure sialylation of transferrin directly from serum. DESIGN AND METHODS:Transferrin samples with different levels ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2007.01.010

    authors: Gornik O,Lauc G

    更新日期:2007-06-01 00:00:00

  • Relevance of pre-analytical blood management on the emerging cardiovascular protein biomarkers TWEAK and HMGB1 and on miRNA serum and plasma profiling.

    abstract:BACKGROUND:Disease-independent sources of biomarker variability include pre-analytical, analytical and biological variance. The aim of the present study was to evaluate whether the pre-analytical phase has any impact on the emerging heart disease TWEAK and HMGB1 protein markers and miRNA biomarkers, and whether peptido...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2016.11.005

    authors: Basso D,Padoan A,Laufer T,Aneloni V,Moz S,Schroers H,Pelloso M,Saiz A,Krapp M,Fogar P,Cornoldi P,Zambon CF,Rossi E,La Malfa M,Marotti A,Brefort T,Weis TM,Katus HA,Plebani M

    更新日期:2017-03-01 00:00:00

  • Oxidative imbalance in low/intermediate-1-risk myelodysplastic syndrome patients: The influence of iron overload.

    abstract:OBJECTIVE:To assess the generation of reactive oxygen species (ROS) and the involvement of the main antioxidant pathways in low/intermediate-1-risk myelodysplastic syndromes (MDS) with iron overload (IOL). METHODS:We examined the levels of superoxide anion (O2-), hydrogen peroxide (H2O2), antioxidants (glutathione, GS...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2017.05.018

    authors: Ivars D,Orero MT,Javier K,Díaz-Vico L,García-Giménez JL,Mena S,Tormos C,Egea M,Pérez PL,Arrizabalaga B,Ruiz MÁ,Yagüe N,Tormo M,Sancho-Tello R,Gomes A,Algueró C,O'Connor JE,Sáez GT,Carbonell F,Collado R

    更新日期:2017-11-01 00:00:00

  • Cancer Care Ontario guaiac fecal occult blood test (FOBT) laboratory standards: evidentiary base and recommendations.

    abstract:OBJECTIVES:To evaluate the evidence concerning gFOBT kits and to develop gFOBT standards to be implemented by the Ontario Colorectal Cancer (CRC) Screening Program (the "Program"). DESIGN AND METHODS:We evaluated 3 aspects of gFOBT kits: 1) performance factors; 2) usability factors; and 3) laboratory factors. We obtai...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,meta分析

    doi:10.1016/j.clinbiochem.2008.08.069

    authors: Rabeneck L,Zwaal C,Goodman JH,Mai V,Zamkanei M

    更新日期:2008-11-01 00:00:00

  • Effects of metamizol and magnesium sulfate on enzyme activity of glucose 6-phosphate dehydrogenase from human erythrocyte in vitro and rat erythrocyte in vivo.

    abstract:OBJECTIVE:Effects of metamizol and magnesium sulfate on erythrocyte glucose 6-phosphate dehydrogenase enzyme activity were investigated in in vitro and in vivo conditions. METHODS:For in vitro studies, glucose 6-phosphate dehydrogenase was purified from human erythrocyte and rats were used for in vivo studies. Enzyme ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(01)00207-7

    authors: Ciftçi M,Ozmen I,Büyükokuroğlu ME,Pençe S,Küfrevioğlu OI

    更新日期:2001-06-01 00:00:00

  • Do wine polyphenols modulate p53 gene expression in human cancer cell lines?

    abstract:BACKGROUND:The p53 gene is an established tumor suppressor and an inducer of apoptosis. We here attempt to determine whether the putative anticarcinogenic properties attributed to red wine and its polyphenolic constituents depend, at least in part, upon their ability to modulate p53 expression in cancer cells. METHODS...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(01)00246-6

    authors: Soleas GJ,Goldberg DM,Grass L,Levesque M,Diamandis EP

    更新日期:2001-07-01 00:00:00

  • A sensitive method for the determination of hydrochlorothiazide in serum by high pressure liquid chromatography.

    abstract::A high pressure liquid chromatographic method for the determination of hydrochlorothiazide in serum has been elaborated and verified in a blood level study in normal individuals given a single oral dose of 50 mg hydrochlorothiazide. Based on 5 ml of serum, the limit of detection of the method is 2 ng/ml. ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(78)90434-4

    authors: Robinson WT,Cosyns L

    更新日期:1978-08-01 00:00:00

  • Analytical interference of 4-hydroxy-3-methoxymethamphetamine with the measurement of plasma free normetanephrine by ultra-high pressure liquid chromatography-tandem mass spectrometry.

    abstract:OBJECTIVES:The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxym...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2014.04.003

    authors: Dunand M,Donzelli M,Rickli A,Hysek CM,Liechti ME,Grouzmann E

    更新日期:2014-08-01 00:00:00

  • Effect of whole soy and purified isoflavone daidzein on renal function--a 6-month randomized controlled trial in equol-producing postmenopausal women with prehypertension.

    abstract:OBJECTIVES:The aim of the study was to examine the long-term effect of commonly used whole soy foods (soy flour) and purified daidzein (one major isoflavone and the precursor of equol) on renal function among prehypertensive postmenopausal women who are also equol producers, a population most likely to benefit from soy...

    journal_title:Clinical biochemistry

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/j.clinbiochem.2014.05.054

    authors: Liu ZM,Ho SC,Chen YM,Tang N,Woo J

    更新日期:2014-09-01 00:00:00

  • Plasma vaspin concentrations are decreased in acute coronary syndrome, but unchanged in patients without coronary lesions.

    abstract:OBJECTIVE:Previous studies suggested that decreased serum vaspin levels were associated with coronary artery disease (CAD). The present study aimed to investigate the association between plasma vaspin levels and different states of CAD. DESIGN AND METHODS:A total of 162 patients with coronary angiography (CAG) proved ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2013.06.028

    authors: Zhang B,Peng W,Li H,Lu Y,Zhuang J,Wang K,Su Y,Xu Y

    更新日期:2013-10-01 00:00:00

  • Serum vascular adhesion protein-1 is higher in subjects with early stages of chronic kidney disease.

    abstract:OBJECTIVES:An increased level of serum vascular adhesion protein-1 (VAP-1) has been found in patients with diabetes mellitus and vascular disorders. This study examined whether serum VAP-1 levels are associated with chronic kidney disease (CKD). DESIGN AND METHODS:We included 262 subjects aged 30 and above with fastin...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2008.06.019

    authors: Lin MS,Li HY,Wei JN,Lin CH,Smith DJ,Vainio J,Shih SR,Chen YH,Lin LC,Kao HL,Chuang LM,Chen MF

    更新日期:2008-11-01 00:00:00

  • The multiple functions and mechanisms of osteopontin.

    abstract::Osteopontin (OPN) is a highly phosphorylated glycophosphoprotein having acidic characteristics and rich in aspartic acid. OPN, a multifunctional protein, has important functions on cardiovascular diseases, cancer, diabetes and kidney stone diseases and in the process of inflammation, biomineralization, cell viability ...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1016/j.clinbiochem.2018.07.003

    authors: Icer MA,Gezmen-Karadag M

    更新日期:2018-09-01 00:00:00

  • Isolation of drugs from blood serum by the Du Pont Prep I Automated Sample Processor and a C18 bonded phase adsorption column.

    abstract::We describe a fast and efficient method for the isolation of drugs from blood serum by use of the DU PONT PREP I Automated Sample Processor and octadecyl bonded phase columns. Drugs are selectively adsorbed onto C18 bonded phase and eluted with methanol. The recovered residue is essentially free of sample matrix chrom...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(81)91245-5

    authors: Repique EV,Sacks HJ,Farber SJ

    更新日期:1981-08-01 00:00:00

  • A semi-automated enzymatic assay for free glycerol and triglycerides in serum or plasma.

    abstract::1. A relatively inexpensive semi-automated enzymatic procedure is described for the determination of total glycerol with an Auto Analyzer. Free glycerol is determined without saponification in a deproteinized supernatant. 2. The dilution of triglyceride samples during preparation is such that the samples during prepar...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(77)90232-6

    authors: MacRae AR

    更新日期:1977-02-01 00:00:00

  • Measurement of cystine in granulocytes using liquid chromatography-tandem mass spectrometry.

    abstract:BACKGROUND:Cystinosis is a rare autosomal recessive disorder characterized by an accumulation of intralysosomal cystine due to a defect in cystine transport across the lysosomal membrane. This disorder can be treated specifically using high doses of cysteamine. Accurate measurement of intracellular cystine content is n...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2007.02.005

    authors: Chabli A,Aupetit J,Raehm M,Ricquier D,Chadefaux-Vekemans B

    更新日期:2007-06-01 00:00:00

  • The effect of the mode of delivery on the maternal-neonatal erythrocyte membrane acetylcholinesterase activity.

    abstract:UNLABELLED:Free radical production and high catecholamine levels are implicated with the modulation of acetylcholinesterase (AChE) activity. OBJECTIVE:To investigate the effect of the mode of delivery on maternal-neonatal erythrocyte membrane AChE activity. SUBJECTS AND METHODS:Some women with normal pregnancy (N = 3...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2008.04.005

    authors: Vlachos DG,Schulpis KH,Parthimos T,Mesogitis S,Vlachos GD,Partsinevelos GA,Antsaklis A,Tsakiris S

    更新日期:2008-07-01 00:00:00

  • Beta-hexosaminidase isoenzyme profiles in serum, plasma, platelets and mononuclear, polymorphonuclear and unfractionated total leukocytes.

    abstract:OBJECTIVES:The relative proportion in percentage of the isoenzyme A of beta-hexosaminidase (Hex) is the single discriminatory function most frequently used for the biochemical screening of heterozygote Tay-Sachs disease carriers. It has been suggested that the assay of the Hex isoenzymes in homogeneous cell preparation...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2005.05.016

    authors: Casal JA,Cano E,Tutor JC

    更新日期:2005-10-01 00:00:00

  • Clinical assessment of specific enzyme immunoassay for the human cardiac myosin light chain II (MLC II) with use of monoclonal antibodies.

    abstract::A highly specific enzyme-linked "sandwich" immunoassay was developed for determining cardiac myosin light chain II (MLC II) in serum by using an anticardiac MLC II monoclonal antibody and a solid phase consisting of glass rods coated with another monoclonal antibody. We can detect as little as 0.2 ng of cardiac MLC II...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/0009-9120(90)80042-h

    authors: Hirayama A,Arita M,Takagaki Y,Tsuji A,Kodama K,Inoue M

    更新日期:1990-12-01 00:00:00

  • Quantification of urinary allantoin by capillary zone electrophoresis during recombinant urate oxydase (rasburicase) therapy.

    abstract:OBJECTIVES:Rasburicase (Fasturtec) is used to prevent or treat hyperuricemia associated with chemotherapy. We developed a capillary zone electrophoresis method to measure urinary allantoin, the degradation product of uric acid by rasburicase. DESIGN AND METHODS:Electrophoresis was performed using a P/ACE 5500 system (...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2005.09.013

    authors: Kattygnarath D,Mounier N,Madelaine-Chambrin I,Gourmel B,Le Bricon T,Gisselbrecht C,Faure P,Houzé P

    更新日期:2006-01-01 00:00:00

  • Clinical varieties of carnitine and carnitine palmitoyltransferase deficiency.

    abstract::Several clinical entities are associated with disorders of fatty acid oxidation or transfer across the inner mitochondrial membrane. Over 40 cases of the primary carnitine deficiency syndrome have been reported to date and various subtypes have been characterized. This represents a large clinical spectrum. The deficie...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章,评审

    doi:10.1016/s0009-9120(87)80090-5

    authors: Angelini C,Trevisan C,Isaya G,Pegolo G,Vergani L

    更新日期:1987-02-01 00:00:00

  • Variations in ovarian steroid levels during the luteal phase of the menstrual cycle.

    abstract::1. Six subjects were investigated during the luteal phase of the menstrual cycle to determine whether the ovarian steroids, estrogen and progesterone were released in an episodic manner. 2. Analysis of plasma obtained every 20 min. during a normal working day provided no evidence for pulsatile release of either steroi...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/s0009-9120(75)92479-0

    authors: Younglai EV,Smith SL,Cleghorn JM,Streiner DL

    更新日期:1975-08-01 00:00:00

  • Adult cystatin C reference intervals determined by nephelometric immunoassay.

    abstract:OBJECTIVE:The aim of this study was to determine the adult reference values for cystatin C (CysC) and to evaluate their consistence with those reported in the literature. DESIGN AND METHODS:CysC was analyzed in a consecutive series of subjects (100 males and 100 females) by a nephelometric immunoassay. Medline was sea...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2007.05.011

    authors: Croda-Todd MT,Soto-Montano XJ,Hernández-Cancino PA,Juárez-Aguilar E

    更新日期:2007-09-01 00:00:00

  • Purification and characterization of cyclosporine and FK-506 binding proteins from a human T-helper cell line.

    abstract::Cytosolic proteins that specifically bind cyclosporine A and FK-506 were isolated and purified from the JURKAT human T-helper cell line. These binding proteins were purified by affinity, molecular weight exclusion and weak cation exchange column chromatography. Radiolabeled cyclosporine A specifically bound to a appro...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/0009-9120(91)90252-a

    authors: Palaszynski EW,Donnelly JG,Soldin SJ

    更新日期:1991-02-01 00:00:00

  • Association of serum adiponectin with diabetic microvascular complications among south Indian type 2 diabetic subjects - (CURES-133).

    abstract:OBJECTIVES:To assess the association of serum adiponectin and microvascular complications of diabetes in an urban south Indian type 2 diabetic population. DESIGN AND METHODS:Diabetic subjects [n=487] were included from Chennai Urban Rural Epidemiology Study (CURES). Four-field stereo retinal color photography was done...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2014.10.009

    authors: Pradeepa R,Surendar J,Indulekha K,Chella S,Anjana RM,Mohan V

    更新日期:2015-01-01 00:00:00

  • Functional polymorphism in the manganese superoxide dismutase (MnSOD) gene in patients with asthma.

    abstract:OBJECTIVES:To investigate the possible association between functional variant Ala-9Val in the MnSOD gene and asthma in the case-control study comprising 626 Caucasian subjects. METHODS:MnSOD genotypes were determined by PCR with subsequent restriction analysis by the BsaWI enzyme. RESULTS:Significant differences in a...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2005.12.001

    authors: Holla LI,Kankova K,Vasku A

    更新日期:2006-03-01 00:00:00

  • Platelet activating factor (PAF) and activity of its biosynthetic and catabolic enzymes in blood and leukocytes of male patients with newly diagnosed heart failure.

    abstract:OBJECTIVES:To evaluate platelet activating factor (PAF) levels, its metabolic enzymes activity and its associations with other inflammatory markers in heart failure (HF) patients. DESIGN AND METHODS:PAF, and two of its key biosynthetic enzymes [lyso-PAF acetyltransferase (lyso-PAF-AT) and DTT-insensitive CDP-choline:1...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2008.09.113

    authors: Detopoulou P,Nomikos T,Fragopoulou E,Antonopoulou S,Kotroyiannis I,Vassiliadou C,Panagiotakos DB,Chrysohoou C,Pitsavos C,Stefanadis C

    更新日期:2009-01-01 00:00:00

  • Performance characteristics of six automated 25-hydroxyvitamin D assays: Mind your 3s and 2s.

    abstract:BACKGROUND:Measurement of 25(OH)D has evolved rapidly, with an increased number of high-throughput automated immunoassays becoming available in recent years. The aim of this study was to fully evaluate six commercially available automated 25(OH)D immunoassays, including 2 newly available (Beckman Coulter) and one recal...

    journal_title:Clinical biochemistry

    pub_type: 杂志文章

    doi:10.1016/j.clinbiochem.2015.08.005

    authors: Wyness SP,Straseski JA

    更新日期:2015-11-01 00:00:00