Sympatho-vagal balance, as quantified by ANSindex, predicts post spinal hypotension and vasopressor requirement in parturients undergoing lower segmental cesarean section: a single blinded prospective observational study.

Abstract:

:Hypotension subsequent to spinal anesthesia occurs in a significant number of parturients undergoing lower segment caesarian section. Currently available methods to predict the incidence of hypotension, its severity and the outcome are sub-optimal. Many workers have used basal heart rate as one of the predictors. But using this method it is not possible to objectively analyze and predict the extent and severity of hypotension. We used an equipment measuring the level of sympatho-vagal balance, ANSiscope™, which derives these values from computed value of RR interval variability. We made a single measure of the value which was blinded to the patient and the anesthesiologist. We studied one hundred eight patients who underwent lower segment caesarian section under spinal anesthesia and found the variability of preoperative ANSindex (% activity displayed by the equipment) from 9 to 65 %. Higher ANSindex value was significantly associated with post spinal hypotension (p 0.017). A value of 24 % indicated the critical level above which hypotension appeared commonly. The ANSindex value might help anesthesiologist to anticipate and prepare for hypotension that is likely to ensue.

journal_name

J Clin Monit Comput

authors

Prashanth A,Chakravarthy M,George A,Mayur R,Hosur R,Pargaonkar S

doi

10.1007/s10877-016-9906-9

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

805-811

issue

4

eissn

1387-1307

issn

1573-2614

pii

10.1007/s10877-016-9906-9

journal_volume

31

pub_type

杂志文章
  • Lessons learned from closed loops in engineering: towards a multivariable approach regulating depth of anaesthesia.

    abstract::In this paper is presented a brief state of art regarding the multivariable formulation for controlling the depth of anaesthesia by means of two intravenously administrated drugs, i.e. propofol and remifentanil. In a feasibility study of determining a suitable variable to quantify analgesia levels in patients undergoi...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9535-5

    authors: Ionescu CM,Nascu I,De Keyser R

    更新日期:2014-12-01 00:00:00

  • Heart rate variability analysis during central hypovolemia using wavelet transformation.

    abstract::Detection of hypovolemia prior to overt hemodynamic decompensation remains an elusive goal in the treatment of critically injured patients in both civilian and combat settings. Monitoring of heart rate variability has been advocated as a potential means to monitor the rapid changes in the physiological state of hemorr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9434-9

    authors: Ji SY,Belle A,Ward KR,Ryan KL,Rickards CA,Convertino VA,Najarian K

    更新日期:2013-06-01 00:00:00

  • Ergonomic automated anesthesia recordkeeper using a mobile touch screen with voice navigtion.

    abstract:OBJECTIVE:To develop an ergonomically designed computerized recordkeeping tool for anesthesiologists that allows the clinician to maintain visual contact with the patient while performing recordkeeping. METHODS:To simplify the human interface software, we developed two general use software components. All purpose menu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009972223750

    authors: Sanjo Y,Yokoyama T,Sato S,Ikeda K,Nakajima R

    更新日期:1999-08-01 00:00:00

  • Continuous hemoglobin and plethysmography variability index monitoring can modify blood transfusion practice and is associated with lower mortality.

    abstract::To determine the effect of implementing an algorithm of fluid and blood administration based on continuous monitoring of hemoglobin (SpHb) and PVI (plethysmography variability index) on mortality and transfusion on a whole hospital scale. This single-center quality program compared transfusion at 48 h and mortality at...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00367-z

    authors: Cros J,Dalmay F,Yonnet S,Charpentier M,Tran-Van-Ho J,Renaudeau F,Drouet A,Guilbaut P,Marin B,Nathan N

    更新日期:2020-08-01 00:00:00

  • Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.

    abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00436-3

    authors: Cammarota G,Verdina F,Santangelo E,Lauro G,Boniolo E,Tarquini R,Spinelli E,Zanoni M,Garofalo E,Bruni A,Pesenti A,Della Corte F,Navalesi P,Vaschetto R,Mauri T

    更新日期:2020-12-01 00:00:00

  • Breathing variability predicts the suggested need for corrective intervention due to the perceived severity of patient-ventilator asynchrony during NIV.

    abstract::Patient-ventilator asynchrony is associated with intolerance to noninvasive ventilation (NIV) and worsened outcomes. Our goal was to develop a tool to determine a patient needs for  intervention by a practitioner due to the presence of patient-ventilator asynchrony. We postulated that a clinician can determine when a ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00408-7

    authors: Tams C,Stephan PJ,Euliano NR,Martin AD,Patel R,Ataya A,Gabrielli A

    更新日期:2020-10-01 00:00:00

  • Effective hypertensive treatment using data mining in Saudi Arabia.

    abstract::In the present investigation, the data sets of NCD (Non Communicable Diseases) risk factors, a standard report of Saudi Arabia 2005, in collaboration with WHO (World Health Organisation) were employed. The Oracle Data Miner (ODM) tool was used for the analysis and prediction of data. The data sets for different age gr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9260-2

    authors: Almazyad AS,Ahamad MG,Siddiqui MK,Almazyad AS

    更新日期:2010-12-01 00:00:00

  • Validation of a mathematical model for understanding intracranial pressure curve morphology.

    abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00342-8

    authors: Unnerbäck M,Ottesen JT,Reinstrup P

    更新日期:2020-06-01 00:00:00

  • Effects of ultrasound-guided stellate-ganglion block on sleep and regional cerebral oxygen saturation in patients undergoing breast cancer surgery: a randomized, controlled, double-blinded trial.

    abstract::Numerous factors could contribute to sleep disturbances in women with breast cancer. We hypothesized that stellate ganglion block (SGB) during surgery would preserve sleep after surgery and increase intraoperative regional cerebral oxygen saturation (rSO2) on the blocked side in patients undergoing breast cancer surge...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0074-3

    authors: Jin F,Li XQ,Tan WF,Ma H,Fang B,Tian AY,Lu HW

    更新日期:2018-10-01 00:00:00

  • The influence of basic ventilation strategies on cerebral oxygenation in anesthetized patients without vascular disease.

    abstract:OBJECTIVES:Optimizing cerebral oxygenation is of paramount importance in certain intraoperative situations. There is, however, a paucity of published data pertaining to changes in cerebral oxygenation seen with increases in the inspired fraction of oxygen (FIO2) or end-tidal carbon dioxide (PETCO2) in anesthetized pati...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-010-9265-x

    authors: Picton P,Shanks A,Dorje P,Mashour GA

    更新日期:2010-12-01 00:00:00

  • Effects of a sigh on the respiratory mechanical properties in ali patients.

    abstract:OBJECTIVES:The application of sighs during baseline ventilation was found to improve alveolar recruitment and oxygenation in patients with acute respiratory distress syndrome (ARDS). The present investigation evaluates if respiratory mechanics can be modified by a sigh. METHODS:Ten consecutive patients with acute lung...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-006-9028-x

    authors: Antonaglia V,Pascotto S,Simoni LD,Zin WA

    更新日期:2006-08-01 00:00:00

  • Bench test assessment of mainstream capnography during high frequency oscillatory ventilation.

    abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-013-9495-9

    authors: Hartdorff CM,van Heerde M,Markhorst DG

    更新日期:2014-02-01 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • Predictive value of the surgical pleth index for the hemodynamic responses to trachea intubation and skin incision.

    abstract::Surgical pleth index (SPI) has been widely investigated in assessing the nociceptive level. The aim of this study was to investigate the relationship between SPI level and patient responses to trachea intubation and skin incision. A total of 40 patients undergoing open abdominal general surgery were recruited for anal...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00425-6

    authors: Wang M,Wang X,Bao R,Zhu WZ,Bian JJ,Deng XM,Han WJ,Wang JF

    更新日期:2020-12-01 00:00:00

  • Partitioning the resistances along the vascular tree: effects of dobutamine and hypovolemia in piglets with an intact circulation.

    abstract:OBJECTIVE:We present a new physiological model that discriminated between changes in the systemic arterial and venous circulation. To test our model, we studied the effects of dobutamine and hypovolemia in intact pentabarbital-anesthetized piglets. METHODS:Aorta pressure (Pao), central venous pressure (Pcv), mean syst...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9258-9

    authors: Geerts BF,Maas JJ,Aarts LP,Pinsky MR,Jansen JR

    更新日期:2010-10-01 00:00:00

  • Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

    abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9344-2

    authors: Chen G,Chung E,Meng L,Alexander B,Vu T,Rinehart J,Cannesson M

    更新日期:2012-04-01 00:00:00

  • Estimation of pulse pressure variation and cardiac output in patients having major abdominal surgery: a comparison between a mobile application for snapshot pulse wave analysis and invasive pulse wave analysis.

    abstract::Pulse pressure variation (PPV) and cardiac output (CO) can guide perioperative fluid management. Capstesia (Galenic App, Vitoria-Gasteiz, Spain) is a mobile application for snapshot pulse wave analysis (PWAsnap) and estimates PPV and CO using pulse wave analysis of a snapshot of the arterial blood pressure waveform di...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00572-1

    authors: Hoppe P,Gleibs F,Briesenick L,Joosten A,Saugel B

    更新日期:2020-08-04 00:00:00

  • A motor evoked potential trending system may discriminate outcome: retrospective application with three cases.

    abstract::This report presents a method for tracking Motor Evoked Potential (MEP) amplitudes over the course of a case using a moving least squares linear regression (LSMAs). During a case, newly obtained MEP amplitudes are compared to those predicted by a just previous linear regression (least squares moving average or LSMA). ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0181-9

    authors: Jasiukaitis P,Lyon R

    更新日期:2019-06-01 00:00:00

  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • Risk factors for positioning-related somatosensory evoked potential changes in 3946 spinal surgeries.

    abstract::The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure rel...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0148-x

    authors: Melachuri SR,Balzer JR,Melachuri MK,Ninaci D,Anetakis K,Kaur J,Crammond DJ,Thirumala PD

    更新日期:2019-04-01 00:00:00

  • The correlation of the bispectral index with propofol effect site concentrations is not altered by epochs indicated as artefact-loaded by narcotrend.

    abstract:OBJECTIVE:Artefact detection is an essential feature of automatic EEG monitoring systems used in anaesthesia. Clinical experience indicates that Narcotrend monitoring (MonitorTechnik, Bad Bramstedt, Germany, version 4.0) excludes more EEG epochs because of artefacts than bispectral index monitoring (BIS, Aspect Medical...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10877-005-2700-8

    authors: Ellerkmann RK,Kreuer S,Wilhelm W,Wenningmann I,Roepcke H,Hoeft A,Bruhn J

    更新日期:2004-08-01 00:00:00

  • Multi-parameter vital sign database to assist in alarm optimization for general care units.

    abstract::Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9790-8

    authors: Welch J,Kanter B,Skora B,McCombie S,Henry I,McCombie D,Kennedy R,Soller B

    更新日期:2016-12-01 00:00:00

  • Evaluation of a computerized system for mechanical ventilation of infants.

    abstract:OBJECTIVE:To evaluate a computerized system for mechanical ventilation of infants. METHODS:FLEX is a computerized system that includes the features of a patented mode known as adaptive-support ventilation (ASV). In addition, it has many other features including adjustment of positive end-expiratory pressure (PEEP), fr...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9170-3

    authors: Tehrani FT,Abbasi S

    更新日期:2009-04-01 00:00:00

  • Correlation between preoperative somatosensory evoked potentials and intraoperative neurophysiological monitoring in spinal cord tumors.

    abstract::Intraoperative neurophysiological monitoring (IONM) is widely used in spinal cord tumors (SCTs) removal surgery. This study mainly hypothesized that patients with prolonged latency of preoperative somatosensory evoked potentials (preSEPLat) would have more deteriorated intraoperative evoked potentials. Among 506 patie...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00584-x

    authors: Park J,Cho YE,Park M,Lee J,Kim D,Park YG

    更新日期:2020-09-29 00:00:00

  • Changes in cerebral and renal oxygenation during laparoscopic pyloromyotomy.

    abstract::Although a laparoscopic approach may be preferred over open procedures for abdominal surgery, there are limited data on the effect of laparoscopic procedures on cerebral and renal oxygenation in neonates and young infants. Here, we evaluated the effect in neonates and infants. In this two-center prospective observatio...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00356-2

    authors: Kamata M,Hakim M,Walia H,Tumin D,Tobias JD

    更新日期:2020-08-01 00:00:00

  • Novel hand-held device for exhaled nitric oxide-analysis in research and clinical applications.

    abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-1158-z

    authors: Hemmingsson T,Linnarsson D,Gambert R

    更新日期:2004-12-01 00:00:00

  • COVID-19: Pulse oximeters in the spotlight.

    abstract::From home to intensive care units, innovations in pulse oximetry are susceptible to improve the monitoring and management of patients developing acute respiratory failure, and particularly those with the coronavirus disease 2019 (COVID-19). They include self-monitoring of oxygen saturation (SpO2) from home, continuous...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 社论

    doi:10.1007/s10877-020-00550-7

    authors: Michard F,Shelley K,L'Her E

    更新日期:2020-06-23 00:00:00

  • Assessment of the benefits of head-up preoxygenation using near-infrared spectroscopy with pulse oximetry in a swine model.

    abstract::Compared with supine positioning, head-up positioning improves preoxygenation and prolongs the time to oxygen desaturation. We reevaluated benefits of head-up positioning using near-infrared spectroscopy (NIRS) with pulse oximetry in a pig model. Six pigs (mean ± SD weight: 25.3 ± 0.6 kg) were anesthetized with isoflu...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00456-z

    authors: Kurita T,Kawashima S,Morita K,Nakajima Y

    更新日期:2020-01-02 00:00:00

  • Bi-spectral index guided closed-loop anaesthesia delivery system (CLADS) in pheochromocytoma.

    abstract:OBJECTIVES:Anaesthetic management of pheochromocytoma is far from satisfactory even though various techniques are available. Feasibility as well as safety of Bi-spectral Index (BIS)-guided closed-loop control of anaesthesia has been shown in various clinical settings. We evaluated the performance of BIS-guided closed-l...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-009-9181-0

    authors: Hegde HV,Puri GD,Kumar B,Behera A

    更新日期:2009-08-01 00:00:00

  • Towards an optimal paradigm for intraoperative auditory nerve monitoring with auditory steady state responses.

    abstract::Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-016-9837-5

    authors: Rampp S,Rensch L,Simmermacher S,Rahne T,Strauss C,Prell J

    更新日期:2017-02-01 00:00:00