Lateral Sinus Dural Arteriovenous Fistulas: Sinovenous Outflow Restriction Outweighs Cortical Venous Reflux as a Parameter Associated with Hemorrhage.

Abstract:

:Purpose To investigate whether sinovenous outflow restriction (SOR) is more strongly associated with hemorrhage than cortical venous reflux (CVR) in patients with lateral sinus dural arteriovenous fistulas (DAVFs). Materials and Methods An institutional review board approved this retrospective study and waiver of informed consent was obtained. From 1995 to 2016, 163 cases of lateral sinus DAVFs were included and divided into hemorrhagic and nonhemorrhagic groups based on initial presentation. Their angiograms and magnetic resonance images were evaluated, with two evaluators independently grading CVR and SOR. The SOR was scored as the combined conduit score (CCS), ranging from zero (total occlusion) to 8 (fully patent). The CVR and CCS of the hemorrhagic and nonhemorrhagic groups were compared. Logistic regression models were established for both the CVR and CCS to compare their performances in discriminating DAVF hemorrhage. Results Sinovenous outflow was significantly more restrictive (lower median CCS) in the hemorrhagic group than in the nonhemorrhagic group (1 vs 6.5; P < .001). A CCS of less than or equal to 2 best discriminated between the groups with a sensitivity of 90.0% and a specificity of 88.1%. The CCS model had a higher discriminative performance than did the CVR model (area under the curve, 0.933 vs 0.843; P = .018). Conclusion The CCS grading system semiquantifies SOR. SOR may represent a stronger risk factor associated with hemorrhage in patients with lateral sinus DAVFs than does CVR, and thus may offer guidance in therapeutic decision making. © RSNA, 2017.

journal_name

Radiology

journal_title

Radiology

authors

Hu YS,Lin CJ,Wu HM,Guo WY,Luo CB,Wu CC,Chung WY,Liu KD,Yang HC,Lee CC

doi

10.1148/radiol.2017162594

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

528-535

issue

2

eissn

0033-8419

issn

1527-1315

journal_volume

285

pub_type

杂志文章
  • Nonpalpable prostate cancer: detection with MR imaging.

    abstract::The pathologic specimens and magnetic resonance (MR) images of 53 patients with clinically palpable prostate cancer confined to one lobe were studied to evaluate the ability of MR imaging to depict clinically nonpalpable prostate cancer. All patients had undergone imaging with a 1.5-T imager with T1- and T2-weighted s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.178.2.1987620

    authors: Carter HB,Brem RF,Tempany CM,Yang A,Epstein JI,Walsh PC,Zerhouni EA

    更新日期:1991-02-01 00:00:00

  • Metallic clip deployment during stereotactic breast biopsy: retrospective analysis.

    abstract:PURPOSE:To determine the visibility of presumably excised lesions on screen-film mammograms obtained after biopsy and to determine the accuracy of clip deployment on the basis of measurements obtained on routine pre- and postbiopsy mammograms. MATERIALS AND METHODS:One hundred eleven cases of core-needle biopsy with c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.2.r01fe39510

    authors: Rosen EL,Vo TT

    更新日期:2001-02-01 00:00:00

  • Work in progress. Transcatheter thermal venous occlusion: a new technique.

    abstract::Diatrizoate (76%) contrast agent heated to 100 degrees C was injected into the veins of dogs and one human volunteer for the nonsurgical occlusion of the vessels. Follow-up venograms and histologic examinations, at intervals varying from one day to four weeks later, revealed thrombosis of the injected veins in all ani...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.145.2.7134430

    authors: Rholl KS,Rysavy JA,Vlodaver Z,Cragg AH,Castaneda-Zuniga WR,Amplatz K

    更新日期:1982-11-01 00:00:00

  • The equivalent tissue-air ratio method for making absorbed dose calculations in a heterogeneous medium.

    abstract::The CT scanner makes three-dimensional anatomical information available for treatment planning, the calculational algorithm being the limiting factor in dose calculations. A method has been developed, called the "effective tissue-air ratio method," that uses all the information but reduces it to manageable proportions...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/129.3.787

    authors: Sontag MR,Cunningham JR

    更新日期:1978-12-01 00:00:00

  • Pancreatic and biliary calculi: percutaneous treatment with tunable dye laser lithotripsy.

    abstract::Percutaneous tunable dye laser lithotripsy was used in two patients to successfully fragment a 2-cm left hepatic duct calculus and a 5-mm main pancreatic duct calculus. Tunable dye laser lithotripsy may prove to be a more effective alternative to mechanical lithotripsy. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.1968280

    authors: Feldman RK,Freeny PC,Kozarek RA

    更新日期:1990-03-01 00:00:00

  • Prostatic uptake of Ga-67.

    abstract::Midline activity low in the pelvis seen on Ga-67 scans is frequently attributed to colonic excretion of radionuclide. We have seen two cases of infectious prostatitis with focal uptake of Ga-67 within the prostate gland. We describe a technique of using limited quantities of barium administered by enema and appropriat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6739830

    authors: Sullivan WT,Rosen PR,Weiland FL,Ritchey ML

    更新日期:1984-08-01 00:00:00

  • Suspected acute appendicitis: nonenhanced helical CT in 300 consecutive patients.

    abstract:PURPOSE:To determine the accuracy of helical computed tomography (CT) without the oral, intravenous, or rectal administration of contrast material in confirming suspected acute appendicitis. MATERIALS AND METHODS:Three hundred consecutive patients referred from the departments of surgery and emergency medicine were ex...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.213.2.r99nv44341

    authors: Lane MJ,Liu DM,Huynh MD,Jeffrey RB Jr,Mindelzun RE,Katz DS

    更新日期:1999-11-01 00:00:00

  • Hyperacute thermal lesions: MR imaging evaluation of development in the brain.

    abstract:PURPOSE:To determine the natural time course of development of hyperacute thermal lesions in the brain. MATERIALS AND METHODS:Ten interstitial lesions were created in five rabbit brains with a radio-frequency probe; an electrode-tip temperature of 80 degrees C was maintained for 60 seconds. Continuous fast spin-echo m...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617870

    authors: Farahani K,Mischel PS,Black KL,De Salles AA,Anzai Y,Lufkin RB

    更新日期:1995-08-01 00:00:00

  • DSA versus multi-detector row CT angiography in peripheral arterial disease: randomized controlled trial.

    abstract:PURPOSE:To prospectively compare therapeutic confidence in, patient outcomes (in terms of quality of life) after, and the costs of digital subtraction angiography (DSA) with those of multi-detector row computed tomographic (CT) angiography as the initial diagnostic imaging test in patients with peripheral arterial dise...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1148/radiol.2372040616

    authors: Kock MC,Adriaensen ME,Pattynama PM,van Sambeek MR,van Urk H,Stijnen T,Hunink MG

    更新日期:2005-11-01 00:00:00

  • Standardized abnormal interpretation and cancer detection ratios to assess reading volume and reader performance in a breast screening program.

    abstract:PURPOSE:To determine the relationship between annual screening volume and radiologist performance in the Screening Mammography Program of British Columbia, Canada. MATERIALS AND METHODS:Standardized abnormal interpretation ratios and standardized cancer detection ratios were constructed for 35 readers with at least 3 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.215.2.r00ma42563

    authors: Kan L,Olivotto IA,Warren Burhenne LJ,Sickles EA,Coldman AJ

    更新日期:2000-05-01 00:00:00

  • Imaging of carotid arteries in symptomatic patients: cost-effectiveness of diagnostic strategies.

    abstract:PURPOSE:To assess the cost-effectiveness of noninvasive imaging strategies in patients who have had a transient ischemic attack (TIA) or minor stroke and are suspected of having significant carotid artery stenosis. MATERIALS AND METHODS:From 1997 through 2000, 350 patients were included in a multicenter blinded consec...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1148/radiol.2331030863

    authors: Buskens E,Nederkoorn PJ,Buijs-Van Der Woude T,Mali WP,Kappelle LJ,Eikelboom BC,Van Der Graaf Y,Hunink MG

    更新日期:2004-10-01 00:00:00

  • Demonstration of gastroesophageal reflux in children by radionuclide gastroesophagography.

    abstract::Twenty-five infants and children with proved gastroesophageal reflux were studied by radionuclide gastroesophagography to determine its sensitivity in detecting reflux. Patients swallowed an inert radiotracer (Tc-99m sulfur colloid) and gamma camera images of the stomach and esophagus were made with and without abdomi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/131.2.483

    authors: Rudd TG,Christie DL

    更新日期:1979-05-01 00:00:00

  • Ileal lymphatic metastases from cecal carcinoma.

    abstract::Involvement of the terminal ileum in cases of cecal carcinoma usually results from direct extension through the cecal wall and ileocecal valve. Extensive lymphatic metastasis from cecal carcinoma can result in deranged lymphatic flow and apparently cause metastatic involvement of the ileum and its mesentery in the abs...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.1.7360980

    authors: Moffat RE,Gourley WK

    更新日期:1980-04-01 00:00:00

  • Bone marrow diseases of the spine: differentiation with T1 and T2 relaxation times in MR imaging.

    abstract::Forty-two patients underwent magnetic resonance (MR) imaging for a variety of lesions in the vertebral body. A 0.15-T MR system was employed. Twenty-six patients were found to have malignant metastatic lesions (group 1); 16 had nonneoplastic lesions (group 2). The ability to differentiate between the two groups with M...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.165.2.3659380

    authors: Sugimura K,Yamasaki K,Kitagaki H,Tanaka Y,Kono M

    更新日期:1987-11-01 00:00:00

  • Association of Preoperative US Features and Recurrence in Patients with Classic Papillary Thyroid Carcinoma.

    abstract:PURPOSE:To investigate whether ultrasonographic (US) features of thyroid nodules are associated with tumor recurrence in classic papillary thyroid carcinoma (PTC). MATERIALS AND METHODS:This retrospective study was approved by the Institutional Review Board, and the need to obtain informed consent was waived. A total ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015142470

    authors: Kim SY,Kwak JY,Kim EK,Yoon JH,Moon HJ

    更新日期:2015-11-01 00:00:00

  • Atrial and ventricular functional and structural adaptations of the heart in elite triathletes assessed with cardiac MR imaging.

    abstract:PURPOSE:To assess cardiac morphologic and functional adaptations in elite triathletes with magnetic resonance (MR) imaging and to compare findings to those in recreationally active control subjects. MATERIALS AND METHODS:The institutional review board approved the study, and written informed consent was obtained from ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.10092377

    authors: Scharf M,Brem MH,Wilhelm M,Schoepf UJ,Uder M,Lell MM

    更新日期:2010-10-01 00:00:00

  • Comparison of resting intracoronary particulate imaging and stress thallium-201 studies.

    abstract::Stress thallium-201 and resting dual intracoronary particulate imaging were evaluated in 120 patients who underwent coronary angiography. Forty of 42 patients without significant coronary disease had normal stress images and 41 had normal rest studies. Eighty-three stress perfusion defects were identified in 61 of 78 ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.135.2.7367640

    authors: Kolibash AJ,Call TD,Tetalman MR,Bush CA,Scheu J

    更新日期:1980-05-01 00:00:00

  • Brain MR imaging at ultra-low radiofrequency power.

    abstract:PURPOSE:To explore the lower limits for radiofrequency (RF) power-induced specific absorption rate (SAR) achievable at 1.5 T for brain magnetic resonance (MR) imaging without loss of tissue signal or contrast present in high-SAR clinical imaging in order to create a potentially viable MR method at ultra-low RF power to...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.11092445

    authors: Sarkar SN,Alsop DC,Madhuranthakam AJ,Busse RF,Robson PM,Rofsky NM,Hackney DB

    更新日期:2011-05-01 00:00:00

  • Percutaneous catheter thrombectomy device for acute pulmonary embolism: in vitro and in vivo testing.

    abstract:PURPOSE:To evaluate a percutaneous pulmonary embolism (PE) thrombectomy catheter that aspirates, macerates, and removes thrombus. MATERIALS AND METHODS:Nine in vitro tests were performed by using porcine thrombi at a PE test station that provides continuous fluid output of 2 L/min at a pressure of 50 mmHg. Macroemboli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2363041287

    authors: Kucher N,Windecker S,Banz Y,Schmitz-Rode T,Mettler D,Meier B,Hess OM

    更新日期:2005-09-01 00:00:00

  • The fascicles of the lateral meniscus: an anatomic-arthrographic correlation.

    abstract::A model of the normal anatomy of the capsular attachments of the posterior horn of the lateral meniscus is developed based upon anatomic dissections. The term "fascicles" is applied to the delicate bands of connective tissue which join the posterior lateral meniscus to the joint capsule around the popliteal synovial s...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.2.335

    authors: Jelaso DV

    更新日期:1975-02-01 00:00:00

  • Carcinoma of the cervix: value of plain and gadolinium-enhanced MR imaging in assessing degree of invasiveness.

    abstract::The accuracy of nonenhanced spin-echo (SE) T2-weighted and contrast material-enhanced SE T1-weighted magnetic resonance (MR) imaging in assessing the degree of local tumor invasion was determined prospectively in 53 consecutive patients with clinically established early-stage carcinoma of the cervix. With a 0.5-T supe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.188.3.8351350

    authors: Sironi S,De Cobelli F,Scarfone G,Colombo E,Bolis G,Ferrari A,DelMaschio A

    更新日期:1993-09-01 00:00:00

  • Radiation dose is reduced with a single-pass whole-body multi-detector row CT trauma protocol compared with a conventional segmented method: initial experience.

    abstract::Radiation dose data were collected from a calibrated multi-detector row computed tomographic (CT) scanner during trauma CT. One protocol (used with 10 case subjects) involved a single-pass continuous whole-body acquisition from cranial vertex to symphysis pubis, while the other, conventional protocol (used with 10 con...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2293021651

    authors: Ptak T,Rhea JT,Novelline RA

    更新日期:2003-12-01 00:00:00

  • Fast short-tau inversion-recovery MR imaging.

    abstract::To enhance the versatility of the short-tau inversion-recovery (STIR) sequences, the authors determined a range of repetition time (TR) and inversion time (TI) combinations that suppress signal intensity from fat by study of both patient and phantom images. To make fast STIR images, variations in the following pulsing...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.2.2014300

    authors: Fleckenstein JL,Archer BT,Barker BA,Vaughan JT,Parkey RW,Peshock RM

    更新日期:1991-05-01 00:00:00

  • Quantification of articular cartilage in the knee with pulsed saturation transfer subtraction and fat-suppressed MR imaging: optimization and validation.

    abstract:PURPOSE:To assess the reproducibility and accuracy of volumetric quantifications of articular cartilage in the knee determined with three-dimensional (3D) magnetic resonance (MR) imaging combined with pulsed saturation transfer subtraction (STS) or T1-weighted fat suppression (FS) imaging. MATERIALS AND METHODS:Eight ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.2.8029420

    authors: Peterfy CG,van Dijke CF,Janzen DL,Glüer CC,Namba R,Majumdar S,Lang P,Genant HK

    更新日期:1994-08-01 00:00:00

  • Vertebral-body collapse in focal and diffuse disease: patterns of pathologic processes.

    abstract::The radiographic patterns of vertebral-body collapse and/or endplate deformity were examined in 99 autopsy specimens of the thoracolumbar spine with benign and malignant disease. Angling of endplates was found to be highly predictive of underlying malignancy, whereas concavity was more suggestive of benign disease, fo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.160.2.3726130

    authors: Sartoris DJ,Clopton P,Nemcek A,Dowd C,Resnick D

    更新日期:1986-08-01 00:00:00

  • The angiographic diagnosis of leiomyosarcoma of the inferior vena cava.

    abstract::Two cases of leiomyosarcoma of the inferior vena cava showed a high degree of obstruction of the inferior cava, enlarged local arteries supplying the lesion, neovascularity, and a marked parenchymal blush. Collateral veins bridge the obstruction. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.3.683

    authors: Tegtmeyer CJ,Buschi A

    更新日期:1977-03-01 00:00:00

  • Suture granuloma of the stomach following total colectomy.

    abstract::Stitch granuloma is rarely a consideration in the differential diagnosis of stomach lesions. This report documents the occurrence of a granulomatous mass of gastric origin simulating an intramural tumor. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/127.1.84

    authors: Belleza NA,Lowman RM

    更新日期:1978-04-01 00:00:00

  • Accuracy of fat-suppressed three-dimensional spoiled gradient-echo FLASH MR imaging in the detection of patellofemoral articular cartilage abnormalities.

    abstract:PURPOSE:To determine the accuracy of T1-weighted fat-suppressed (FS) three-dimensional (3D) fast low-angle shot (FLASH) magnetic resonance (MR) imaging for the detection of articular cartilage abnormalities of the patellofemoral joint. MATERIALS AND METHODS:Forty-one patients with suspected internal derangement of the...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.198.1.8539380

    authors: Recht MP,Piraino DW,Paletta GA,Schils JP,Belhobek GH

    更新日期:1996-01-01 00:00:00

  • Patency of Wallstents placed across the venous anastomosis of hemodialysis grafts after percutaneous recanalization.

    abstract:PURPOSE:To determine the patency of Wallstents placed across the venous anastomosis of prosthetic bridge grafts after percutaneous graft recanalization. MATERIALS AND METHODS:Wallstents were placed across 26 lesions at the venous anastomosis of polytetrafluoroethylene (PTFE) grafts in 25 patients (11 men, 14 women; ag...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.209.2.9807560

    authors: Patel RI,Peck SH,Cooper SG,Epstein DM,Sofocleous CT,Schur I,Falk A

    更新日期:1998-11-01 00:00:00

  • Noninvasive quantification of airway inflammation following segmental allergen challenge with functional MR imaging: a proof of concept study.

    abstract:PURPOSE:To evaluate oxygen-enhanced T1-mapping magnetic resonance (MR) imaging as a noninvasive method for visualization and quantification of regional inflammation after segmental allergen challenge in asthmatic patients compared with control subjects. MATERIALS AND METHODS:After institutional review board approval, ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132607

    authors: Renne J,Hinrichs J,Schönfeld C,Gutberlet M,Winkler C,Faulenbach C,Jakob P,Schaumann F,Krug N,Wacker F,Hohlfeld JM,Vogel-Claussen J

    更新日期:2015-01-01 00:00:00