Abstract:
:Purpose To identify wall enhancement patterns on vessel wall MRI that discriminate between stable and unstable unruptured intracranial aneurysm (UIA). Materials and Methods Patients were included from November 2012 through January 2016. Vessel wall MR images were acquired at 3 T in patients with stable (incidental and nonchanging over 6 months) or unstable (symptomatic or changing over 6 months) UIA. Each aneurysm was evaluated by using a four-grade classification of enhancement: 0, none; 1, focal; 2, thin circumferential; and 3, thick (>1 mm) circumferential. Inter- and intrareader agreement for the presence and the grade of enhancement were assessed by using κ statistics and 95% confidence interval (CI). The sensitivity, specificity, and negative and positive predictive values of each enhancement grade for differentiating stable from unstable aneurysms was compared. Results The study included 263 patients with 333 aneurysms. Inter- and intrareader agreement was excellent for both the presence of enhancement (κ values, 0.82 [95% CI: 0.67, 0.99] and 0.87 [95% CI: 0.7, 1.0], respectively) and enhancement grade (κ = 0.92 [95% CI: 0.87, 0.95]). In unruptured aneurysms (n = 307), grade 3 enhancement exhibited the highest specificity (84.4%; 233 of 276; 95% CI: 80.1%, 88.7%; P = .02) and negative predictive value (94.3%; 233 of 247) for differentiating between stable and unstable lesions. There was a significant association between grade 3 enhancement and aneurysm instability (P < .0001). Conclusion In patients with intracranial aneurysm, a thick (>1 mm) circumferential pattern of wall enhancement demonstrated the highest specificity for differentiating between stable and unstable aneurysms. © RSNA, 2018.
journal_name
Radiologyjournal_title
Radiologyauthors
Edjlali M,Guédon A,Ben Hassen W,Boulouis G,Benzakoun J,Rodriguez-Régent C,Trystram D,Nataf F,Meder JF,Turski P,Oppenheim C,Naggara Odoi
10.1148/radiol.2018172879subject
Has Abstractpub_date
2018-10-01 00:00:00pages
181-187issue
1eissn
0033-8419issn
1527-1315journal_volume
289pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Eleven patients (five female and six male, aged 6-67 years) with venous angiomas underwent axial and coronal T1-weighted and fast short inversion time inversion-recovery (STIR) magnetic resonance (MR) imaging to assess the full extent of the malformations. Images were assessed subjectively by the authors in a nonblind...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.194.3.7863000
更新日期:1995-03-01 00:00:00
abstract::To standardize femur measurement for the identification of fetuses at risk for Down syndrome, sonographers of varying professional experience and background measured the femurs of 20 Down syndrome fetuses and 709 normal control fetuses. A regression analysis performed to compare biparietal diameter to femur length on ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.173.2.2529580
更新日期:1989-11-01 00:00:00
abstract:PURPOSE:To compare the new "warp" sequence (slice-encoding metal artifact correction [SEMAC], view-angle tilting [VAT], and increased bandwidth) for the reduction of both through-plane and in-plane magnetic resonance (MR) artifacts with current optimized MR sequences in patients with total hip arthroplasty (THA). MATE...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12112408
更新日期:2012-10-01 00:00:00
abstract:PURPOSE:To assess the feasibility of hybrid imaging of the heart with fluorine 18 fluorodeoxyglucose (FDG) on an integrated 3-T positron emission tomography (PET)/magnetic resonance (MR) imaging system. MATERIALS AND METHODS:The present study was approved by the local institutional review board. Written informed conse...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13130231
更新日期:2013-08-01 00:00:00
abstract:PURPOSE:To review the recurrence patterns in patients with primary non-small cell lung cancer (NSCLC) treated with percutaneous image-guided radiofrequency (RF) ablation. MATERIALS AND METHODS:This retrospective review was institutional review board approved and HIPAA compliant. Informed consent was waived. Data from ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.00000090174
更新日期:2010-01-01 00:00:00
abstract::Human polyclonal immunoglobulin (Ig) G was attached to a monocrystalline iron oxide nanocompound (MION), a small superparamagnetic probe developed for receptor and antibody magnetic resonance (MR) imaging. The resulting complex, MION-IgG, had a slightly negative surface charge, a molecular weight of 150-180 kDa, and 0...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.181.1.1887040
更新日期:1991-10-01 00:00:00
abstract:PURPOSE:To assess retrospectively the incidence, clinical features, and treatment of colonic perforation at computed tomographic (CT) colonography in a large multicenter cohort. MATERIALS AND METHODS:The study was performed in accordance with the institutional ethics committees' requirements of a retrospective review ...
journal_title:Radiology
pub_type: 杂志文章,多中心研究
doi:10.1148/radiol.2392050287
更新日期:2006-05-01 00:00:00
abstract::A retrospective review of 20 cases of endoprosthesis occlusion in 17 patients was performed. The average length of stent patency before occlusion was 3.7 months. Clinical manifestations included one or a combination of the following: cholangitis (n = 17), jaundice (n = 9), and leakage of bile or purulent material from...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.176.2.2367670
更新日期:1990-08-01 00:00:00
abstract::Three cases of a basilar/middle meningeal artery anastomosis are demonstrated angiographically. No reference to previous angiographic demonstration of this vascular anomaly has been found in the literature, and only one similar case with an anatomical description has been located. An embryological explanation of this ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.2.367
更新日期:1976-02-01 00:00:00
abstract::This prospective study compares immediate and delayed patient discomfort in 177 patients following shoulder arthrography using intraarticular combinations of metrizamide, meglumine/sodium diatrizoate, meglumine diatrizoate, lidocaine, epinephrine, and air. Patients receiving conventional ionic monomeric positive contr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.154.2.3966120
更新日期:1985-02-01 00:00:00
abstract::Multiphasic examinations of 153 gastric abnormalities observed radiologically and endoscopically were reviewed to determine the efficacy of four radiologic techniques and of several common combinations of these techniques for examining the stomach. There were 68 gastric ulcers, 12 ulcer scars, 44 cases of gastritis in...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.162.3.3809500
更新日期:1987-03-01 00:00:00
abstract::The classical abnormalities of von Recklinghausen disease (VRD) or neurofibromatosis are well recognized. However, vertebral scalloping and gauge defects of the anterior and lateral aspects have not been reviewed, to the authors' knowledge. Case reports of 3 patients with vertebral scalloping are presented. The classi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.1.89
更新日期:1979-04-01 00:00:00
abstract::Arthrography is considered extremely safe since reactions to intraarticular contrast media are rare. We have only seen one severe complication in the performance of more than 2,000 arthrographic procedures. To determine the incidence of complications, a questionnaire was sent to 84 radiologists experienced in arthrogr...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.4001360
更新日期:1985-06-01 00:00:00
abstract::A vena caval filter than can be introduced percutaneously via the femoral vein is described. We placed these filters in five patients without complications. Experimental work in filter removal one to two weeks after insertion in dogs has been performed. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.3.4001390
更新日期:1985-06-01 00:00:00
abstract::The purposes, implications, and history of development of the American College of Radiology-National Electrical Manufacturers Association (ACR-NEMA) Digital Imaging and Communication Standard and its contents are briefly described, and the minimum requirements of the ACR-NEMA Digital Imaging and Communication Standard...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.166.2.3336730
更新日期:1988-02-01 00:00:00
abstract::The addition of polytomography considerably increases the sensitivity of pneumoencephalography. The chiasmatic area lends itself particularly well to investigation by polytomoencephalography. In a series of 28 patients, the transverse dimension of the optic chiasm ranged from 4 to 20 mm, with a mean of 18 mm. The post...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.3.629
更新日期:1975-03-01 00:00:00
abstract::Eighty-nine biliary strictures in 73 patients who had undergone percutaneous balloon dilatation were reviewed to determine long-term patency rates and clinical management problems. The majority of dilatations were performed in patients with anastomotic strictures (n = 44), iatrogenic strictures (n = 28), and stricture...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.160.1.3715030
更新日期:1986-07-01 00:00:00
abstract::Twenty-three patients were prospectively examined with ultrasound (US) for acute or recurrent Achilles tendon symptoms. Three types of pathologic conditions of the Achilles tendon were found: tendinitis/tenosynovitis, acute tendon trauma, and postoperative changes. US appears to enable differentiation of these conditi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.159.3.3517960
更新日期:1986-06-01 00:00:00
abstract::Wallerian degeneration of rat sciatic nerves was induced by nerve section. Fifteen days later the degenerated nerves were compared with the intact contralateral nerves from the same animal. Histological sections showed the changes typical of wallerian degeneration: axonal degeneration and secondary demyelination. The ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.152.1.6729140
更新日期:1984-07-01 00:00:00
abstract::A case of tuberculosis mimicking carcinoma in the distal colon is reported. The difficulty in diagnosing a solitary tuberculous colonic lesion, a review of the literature, and a differential diagnosis are presented. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.2.293
更新日期:1976-02-01 00:00:00
abstract::Six opossums were evaluated as a possible animal model of radiation esophagitis. In a single exposure to the esophagus, four animals received 60Co radiation of various doses; two served as controls. Pre- and postirradiation evaluations using fiberoptic endoscopy, mucosal biopsy, barium esophagography, and manometry we...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.3.731
更新日期:1979-06-01 00:00:00
abstract::Two cases demonstrated that intravenously injected contrast medium entered cystic lesions. It appears that both vascular opacification and transgression of the blood-brain barrier play major roles in contrast enhancement. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/120.2.345
更新日期:1976-08-01 00:00:00
abstract::Spleen cells from normal or preimmunized mice were exposed to graded doses of peak pions or 300-kVp x rays in vitro and then cultured in heavily irradiated mice to determine antibody production against sheep erythrocytes. The RBE for the primary antibody response was 1.46. Equal suppression of secondary responses was ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.3.803
更新日期:1978-03-01 00:00:00
abstract::A model of the normal anatomy of the capsular attachments of the posterior horn of the lateral meniscus is developed based upon anatomic dissections. The term "fascicles" is applied to the delicate bands of connective tissue which join the posterior lateral meniscus to the joint capsule around the popliteal synovial s...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/114.2.335
更新日期:1975-02-01 00:00:00
abstract::The vertebral involvement of DISH is described from an evaluation of 215 cadaveric spines and 100 patients with the disease. Radiographic features include linear new bone formation along the anterolateral aspect of the thoracic spine, a bumpy contour, subjacent radiolucency, and irregular and pointed bony excrescences...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/119.3.559
更新日期:1976-06-01 00:00:00
abstract:PURPOSE:To evaluate acute myocardial infarction by using first-pass enhancement (FPE) and delayed enhancement (DE) magnetic resonance (MR) imaging compared with thallium 201 ((201)Tl) single photon emission computed tomography (SPECT). MATERIALS AND METHODS:Contrast material-enhanced FPE MR, inversion-recovery DE MR, ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2321031127
更新日期:2004-07-01 00:00:00
abstract:PURPOSE:To determine the dose characteristics of multi-detector row computed tomography (CT) and to provide tabulated dose values and rules of thumb that assist in minimizing the radiation dose at multi-detector row CT. MATERIALS AND METHODS:Weighted CT dose index (CTDI100w) values were obtained from three multi-detec...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2263020205
更新日期:2003-03-01 00:00:00
abstract:PURPOSE:To evaluate the ability to depict anatomy and complications of renal vascular transplant with unenhanced magnetic resonance (MR) angiography with spatial labeling with multiple inversion pulses (SLEEK) and to compare the results with color Doppler (CD) ultrasonography (US), digital subtraction angiography (DSA)...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14131800
更新日期:2014-06-01 00:00:00
abstract::In a comparison of conventional and magnetic resonance (MR) angiography of the lower extremities, MR imaging was performed with extremity and body coils and a unilateral six-coil telescopic phased-array coil. In one of seven volunteers, average signal-to-noise ratio was 140% higher with the latter (p < .01), only thre...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.196.3.7644660
更新日期:1995-09-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate imaging characteristics of surgically proved sublabral recesses and labral tears in the anterior portion of the acetabulum at magnetic resonance (MR) arthrography. MATERIALS AND METHODS:Institutional review board approval was obtained; informed consent was waived. The study included...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2492080137
更新日期:2008-12-01 00:00:00