Mitral annular velocity measurement with cardiac magnetic resonance imaging using a novel annular tracking algorithm: Validation against echocardiography.

Abstract:

BACKGROUND:Doppler based mitral annular velocities are an integral part of echocardiographic left ventricular diastolic function assessment. Although these measurements can be obtained by phase contrast cardiac magnetic resonance imaging (PC-CMR), this approach has limitations. The aims of this study were to assess the accuracy and reproducibility of a high temporal resolution steady-state free precession (SSFP) cine acquisition coupled with semi-automated mitral annular tracking to measure tissue velocity, and compare to echocardiography as the reference method. METHODS:High temporal resolution (17 ms) 4-chamber cines were acquired in 25 volunteers using retrospective and prospective gating on a 3.0 T magnet. Mitral annular early (e') and late (a') tissue velocities were derived using a novel algorithm to semi-automatically detect the mitral valve insertion points and track its motion. Additionally, PC-CMR was used to measure mitral inflow early diastolic (E) velocity. Those measurements were also obtained using echocardiography based pulsed and tissue Doppler techniques, on the same day. RESULTS:Subjects were on average 34 ± 14 years-old (48% male). The lateral annulus e' measurements had the best agreement with echocardiography with a concordance correlation coefficient (CCC) of 0.76 and 0.75 for prospectively and retrospectively gated cine CMR respectively. There was no significant difference in the lateral annular tissue velocities between echocardiography (13.8 ± 3.7 cm/s) and prospective (13.4 ± 3.7 cm/s) or retrospective (14.0 ± 3.7) acquisitions. Similarly, CMR measurement of E/e' (a surrogate marker for LV filling pressures) using the lateral e' velocity showed moderate agreement with echocardiography (CCC of 0.56 and 0.51 for prospective and retrospective acquisitions respectively) without a significant difference in ratios (5.3 ± 1.6 and 5.0 ± 1.3) compared to echocardiography (5.2 ± 1.4). Intra- and inter-observer reproducibility of the CMR-based annular velocity measurements was good. CONCLUSION:Measurements of mitral annular tissue velocities can be obtained from SSFP 4-chamber cine images using a semi-automated annular tracking algorithm, and demonstrates moderate agreement with echocardiography. The semi-automated method can provide quantitative mitral annular velocity measurements directly from conventional cine images, thereby providing additional clinically relevant information. The accuracy of this method in patients with diastolic dysfunction remains to be determined.

journal_name

Magn Reson Imaging

authors

Thavendiranathan P,Guetter C,da Silveira JS,Lu X,Scandling D,Xue H,Jolly MP,Raman SV,Simonetti OP

doi

10.1016/j.mri.2018.08.018

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

72-80

eissn

0730-725X

issn

1873-5894

pii

S0730-725X(18)30277-7

journal_volume

55

pub_type

杂志文章
  • Magnetic nanoparticle-induced hyperthermia treatment under magnetic resonance imaging.

    abstract::Super paramagnetic iron oxide Fe(3)O(4) nanoparticles prepared via photochemical reaction in pure form were used for inducing hyperthermia to treat subcutaneous Ehrlich carcinoma implanted in female mice. Our results indicate that the mean temperature profiles at the rectum, periphery of the tumor surface and at the c...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.08.010

    authors: Elsherbini AA,Saber M,Aggag M,El-Shahawy A,Shokier HA

    更新日期:2011-02-01 00:00:00

  • A simulation-based comparison of two methods for determining relaxation rates from relaxometry images.

    abstract::When assessing liver iron content using relaxometry, an average relaxation rate (R1, R2 or R2*) is usually determined from a region of interest or the entire liver. This is commonly performed by fitting the signal decay in individual voxels to an appropriate relaxation function. The voxel-level parameters resulting fr...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.11.005

    authors: Marro K,Otto R,Kolokythas O,Shimamura A,Sanders JE,McDonald GB,Friedman SD

    更新日期:2011-05-01 00:00:00

  • Magnetization transfer of water T(2) relaxation components in human brain: implications for T(2)-based segmentation of spectroscopic volumes.

    abstract::Biexponential T(2) relaxation of the localized water signal can be used for segmentation of spectroscopic volumes. To assess the specificity of the components an iterative relaxation measurement of the localized water signal (STEAM, 12 echo times, geometric spacing from 30 ms to 2000 ms) was combined with magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00396-4

    authors: Helms G,Piringer A

    更新日期:2001-07-01 00:00:00

  • Echo-shifted multislice EPI for high-speed fMRI.

    abstract::The advantages of event-related functional Magnetic Resonance Imaging (fMRI) and the increasing use of fMRI in cognitive experiments are both driving the development of techniques that allow images sensitive to the blood oxygen level-dependent effect to be acquired at ever-higher temporal resolution. Here, we present ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2005.12.030

    authors: Gibson A,Peters AM,Bowtell R

    更新日期:2006-05-01 00:00:00

  • Simultaneous optimization of power and duration of radio-frequency pulse in PARACEST MRI.

    abstract::Chemical exchange saturation transfer (CEST) MRI is increasingly used to probe mobile proteins and microenvironment properties, and shows great promise for tumor and stroke diagnosis. The CEST effect is complex and depends not only on the CEST agent concentration, exchange rates, the characteristic of the magnetizatio...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2016.02.001

    authors: Rezaeian MR,Hossein-Zadeh GA,Soltanian-Zadeh H

    更新日期:2016-07-01 00:00:00

  • Rapid acquisition strategy for functional T1ρ mapping of the brain.

    abstract::Functional T1ρ mapping has been proposed as a method to assess pH and metabolism dynamics in the brain with high spatial and temporal resolution. The purpose of this work is to describe and evaluate a variant of the spin-locked echo-planar imaging sequence for functional T1ρ mapping at 3T. The proposed sequence rapidl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2014.07.010

    authors: Johnson CP,Heo HY,Thedens DR,Wemmie JA,Magnotta VA

    更新日期:2014-11-01 00:00:00

  • In vivo temporal EPR imaging of the brain of rats by using two types of blood-brain barrier-permeable nitroxide radicals.

    abstract::In vivo temporal EPR imaging was conducted on the brain of rats that received one of two kinds of blood-brain barrier-permeable nitroxide radicals via the tail vein-one is a water-soluble 3-hydroxymethyl-2,2,5,5-tetramethylpyrrolidine-1-oxyl (hydroxymethyl-PROXYL); and the other is a non-water-soluble 3-methoxycarbony...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(02)00491-5

    authors: Yokoyama H,Itoh O,Aoyama M,Obara H,Ohya H,Kamada H

    更新日期:2002-04-01 00:00:00

  • Balanced steady state free precession for arterial spin labeling MRI: Initial experience for blood flow mapping in human brain, retina, and kidney.

    abstract::We implemented pseudo-continuous ASL (pCASL) with 2D and 3D balanced steady state free precession (bSSFP) readout for mapping blood flow in the human brain, retina, and kidney, free of distortion and signal dropout, which are typically observed in the most commonly used echo-planar imaging acquisition. High resolution...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2013.03.024

    authors: Park SH,Wang DJ,Duong TQ

    更新日期:2013-09-01 00:00:00

  • Spiral demystified.

    abstract::Spiral acquisition schemes offer unique advantages such as flow compensation, efficient k-space sampling and robustness against motion that make this option a viable choice among other non-Cartesian sampling schemes. For this reason, the main applications of spiral imaging lie in dynamic magnetic resonance imaging suc...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章,评审

    doi:10.1016/j.mri.2010.03.036

    authors: Delattre BM,Heidemann RM,Crowe LA,Vallée JP,Hyacinthe JN

    更新日期:2010-07-01 00:00:00

  • Agarose as a tissue equivalent phantom material for NMR imaging.

    abstract::Phantoms for evaluation of nuclear magnetic resonance (NMR) imaging systems were made from water-based agarose gels, according to a standard procedure herein described. Copper sulfate (CuSO4) was included in the gels to further affect their proton relaxation characteristics. The proton relaxation rates of each batch o...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(86)91068-4

    authors: Mitchell MD,Kundel HL,Axel L,Joseph PM

    更新日期:1986-01-01 00:00:00

  • STrategically Acquired Gradient Echo (STAGE) imaging, part II: Correcting for RF inhomogeneities in estimating T1 and proton density.

    abstract:PURPOSE:To develop a method for mapping the B1 transmit (B1t) and B1 receive (B1r) fields from two gradient echo datasets each with a different flip angle and from these two images obtain accurate T1 and proton density (PD) maps of the brain. METHODS:A strategically acquired gradient echo (STAGE) data set is collected...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2017.10.006

    authors: Wang Y,Chen Y,Wu D,Wang Y,Sethi SK,Yang G,Xie H,Xia S,Haacke EM

    更新日期:2018-02-01 00:00:00

  • Sampling time effects on signal-to-noise and contrast-to-noise ratios in spin-echo MRI.

    abstract::This work discusses the effect of sampling time on noise, signal-to-noise and contrast-to-noise ratios in magnetic resonance imaging. A simple imaging experiment is performed to demonstrate the effect of sampling time on noise, confirming theoretical expectations that doubling the sampling time while decreasing the re...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(87)90481-4

    authors: Hendrick RE

    更新日期:1987-01-01 00:00:00

  • Evaluation of preprocessing steps to compensate for magnetic field distortions due to body movements in BOLD fMRI.

    abstract::Blood oxygenation level-dependent (BOLD) functional magnetic resonance imaging (fMRI) is currently the dominant technique for non-invasive investigation of brain functions. One of the challenges with BOLD fMRI, particularly at high fields, is compensation for the effects of spatiotemporally varying magnetic field inho...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2009.07.005

    authors: Barry RL,Williams JM,Klassen LM,Gallivan JP,Culham JC,Menon RS

    更新日期:2010-02-01 00:00:00

  • Management of branch-duct intraductal papillary mucinous neoplasms of the pancreas: observation with MR imaging.

    abstract:PURPOSE:To evaluate the clinical outcomes of conservative management by observation with MRI of patients with branch-duct intraductal papillary mucinous neoplasms (BD-IPMNs). MATERIALS AND METHODS:Twenty-three consecutive patients, who were followed up by MRI with magnetic resonance cholangiopancreatography (MRCP) ove...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.06.026

    authors: Shin SS,Armao DM,Shah M,Kim YH,Lee CH,Rubinas T,Brubaker LM,Semelka RC

    更新日期:2010-12-01 00:00:00

  • The use of power images to perform quantitative analysis on low SNR MR images.

    abstract::Zero-mean noise introduced into quadrature detected MRI signals is generally rectified by the reconstruction algorithm to give a nonzero background intensity in the displayed image. In low signal-to-noise ratio (SNR) images, this background will inflate region of interest (ROI) signal measurements, leading to improper...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(93)90225-3

    authors: Miller AJ,Joseph PM

    更新日期:1993-01-01 00:00:00

  • Automated classification of multispectral MR images using unsupervised constrained energy minimization based on fuzzy logic.

    abstract::Constrained energy minimization (CEM) has proven highly effective for hyperspectral (or multispectral) target detection and classification. It requires a complete knowledge of the desired target signature in images. This work presents "Unsupervised CEM (UCEM)," a novel approach to automatically target detection and cl...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.009

    authors: Lin GC,Wang CM,Wang WJ,Sun SY

    更新日期:2010-06-01 00:00:00

  • Localization of ischemia in canine hearts using tagged rotated long axis MR images, endocardial surface stretch and wall thickening.

    abstract::Tagged magnetic resonance imaging allows the noninvasive measurement of regional systolic myocardial deformations and helps localize ischemic regions in the left ventricle (LV). The objective of this study was to evaluate the potential accuracy of localizing ischemic regions in the LV using endocardial and epicardial ...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(97)00161-6

    authors: Denisova O,Shapiro EP,Weiss JL,Azhari H

    更新日期:1997-01-01 00:00:00

  • The NMR-MOUSE: quality control of elastomers.

    abstract::New applications of the NMR-MOUSE (mobile universal surface explorer) to non-destructive quality control of elastomers are reported. One example concern the thermal aging of fast clutches which was probed by measurements of 1H transverse relaxation time. Novel methodological developments show that 1H double-quantum fi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(01)00277-6

    authors: Kühn H,Klein M,Wiesmath A,Demco DE,Blümich B,Kelm J,Gold PW

    更新日期:2001-04-01 00:00:00

  • DUSTER: dynamic contrast enhance up-sampled temporal resolution analysis method.

    abstract::Dynamic contrast enhanced (DCE) MRI using Tofts' model for estimating vascular permeability is widely accepted, yet inter-tissue differences in bolus arrival time (BAT) are generally ignored. In this work we propose a method, incorporating the BAT in the analysis, demonstrating its applicability and advantages in heal...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.12.014

    authors: Liberman G,Louzoun Y,Artzi M,Nadav G,Ewing JR,Ben Bashat D

    更新日期:2016-05-01 00:00:00

  • Peripheral nerve diffusion tensor imaging.

    abstract::We examined if MR diffusion tensor imaging with fiber tracking could be performed on the sciatic nerve. In 3 healthy volunteers the proximal thigh was examined on a 1.5-Tesla MR-scanner with a 2-channel phased-array coil. Though inherently susceptible to motion, field inhomogeneities, and fast T(2)-relaxation of the d...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2004.01.073

    authors: Skorpil M,Karlsson M,Nordell A

    更新日期:2004-06-01 00:00:00

  • Assessment of iron oxide particles (AMI 227) and a gadolinium complex (Gd-DOTA) in dynamic susceptibility contrast MR imagings (FLASH and EPI) in a tumor model implanted in rats.

    abstract::The objective of our study was to assess the feasibility of dynamic susceptibility contrast MR technique after bolus injection of SPIO and Gd-DOTA in a tumor model implanted in rats. Tumors were subcutaneously implanted in 24 rats. A FLASH sequence and EPI were evaluated. Different doses of AMI 227 and Gd-DOTA were as...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(98)00197-0

    authors: Loubeyre P,De Jaegere T,Miao Y,Landuyt W,Marchal G

    更新日期:1999-05-01 00:00:00

  • Flexible, phase-matched, linear receive arrays for high-field MRI in monkeys.

    abstract::High signal-to-noise ratios (SNR) are essential for high-resolution anatomical and functional MRI. Phased arrays are advantageous for this but have the drawback that they often have inflexible and bulky configurations. Particularly in experiments where functional MRI is combined with simultaneous electrophysiology, sp...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2010.03.026

    authors: Goense J,Logothetis NK,Merkle H

    更新日期:2010-10-01 00:00:00

  • A two-compartment phosphate-doped gel phantom for localized spectroscopy.

    abstract::Acrylamide gel loaded with phosphate has been used in two compartment phantoms designed to assess localized spectroscopy techniques. A chemical shift difference of 2.3 ppm was produced by changing the pH from 6 to 8.9. The 31P relaxation times were modified by doping the gels with paramagnetic ions. For a T1 of approx...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/0730-725x(92)90381-9

    authors: Howe FA,Griffiths JR

    更新日期:1992-01-01 00:00:00

  • Ferumoxide-enhanced MRI in patients with colorectal cancer and rising CEA: surgical correlation in early recurrence.

    abstract::The purpose of this study was to evaluate the value of Ferumoxide-enhanced magnetic resonance (MR) imaging in the detection of hepatic metastases in high-risk patients treated for colorectal cancer that have rising CEA. We used 19 patients treated previously for colorectal cancer with rising CEA levels underwent an un...

    journal_title:Magnetic resonance imaging

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0730-725x(99)00134-4

    authors: Said B,McCart JA,Libutti SK,Choyke PL

    更新日期:2000-04-01 00:00:00

  • Diffusion-weighted imaging versus superparamagnetic iron oxide (SPIO)-enhanced MRI: exclusive and combined values in the assessment of hepatic metastases.

    abstract:PURPOSE:The purpose was to validate diffusion-weighted imaging (DWI) in the assessment of hepatic metastases compared with superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance imaging. MATERIALS AND METHODS:For 21 consecutive patients with 160 metastases from extrahepatic malignancy and 25 benign focal lesi...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2011.12.007

    authors: Kim H,Yu JS,Cho ES,Chung JJ,Kim JH,Kim DJ,Ahn JH,Kim KW

    更新日期:2012-05-01 00:00:00

  • A proposal for a semiquantitative scoring system for lymphedema using Non-contrast Magnetic Resonance Lymphography (NMRL): Reproducibility among readers and correlation with clinical grading.

    abstract:PURPOSE:To assess the ability and reproducibility of Non-contrast Magnetic Resonance Lymphography (NMRL) in detecting and quantify lymphedema, using a semiquantitative scoring system. METHODS AND MATERIAL:This is a monocentric retrospective study of 134 consecutive patients with a clinical diagnosis of limb lymphedema...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2020.02.004

    authors: Franconeri A,Ballati F,Panzuto F,Raciti MV,Smedile A,Maggi A,Asteggiano C,Esposito M,Stoppa D,Lungarotti L,Bortolotto C,Giardini D,De Silvestri A,Calliada F

    更新日期:2020-05-01 00:00:00

  • Pretibial cyst formation after anterior cruciate ligament reconstruction using auto hamstring grafts: two case reports in a prospective study of 89 cases.

    abstract::Eighty-nine cases after anterior cruciate ligaments (ACL) reconstruction were followed prospectively with magnetic resonance imaging (MRI). The patients were examined using axial and sagittal MRI at least twice during the postoperative evaluation of reconstructed ACL. Two cases of pretibial cyst formation were observe...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/s0730-725x(00)00207-1

    authors: Deie M,Sumen Y,Ochi M,Murakami Y,Fujimoto E,Ikuta Y

    更新日期:2000-10-01 00:00:00

  • Simultaneous recording of neuronal signals and functional NMR imaging.

    abstract::We recently directly examined the relationship between blood-oxygen-level-dependent (BOLD) functional magnetic resonance imaging (fMRI) signals and neural activity by simultaneously acquiring electrophysiological and fMRI data from monkeys in a 4.7-T vertical scanner (Logothetis NK, Pauls J, Augath MA, Trinath T, Oelt...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2007.03.015

    authors: Oeltermann A,Augath MA,Logothetis NK

    更新日期:2007-07-01 00:00:00

  • Pulseq-Graphical Programming Interface: Open source visual environment for prototyping pulse sequences and integrated magnetic resonance imaging algorithm development.

    abstract:PURPOSE:To provide a single open-source platform for comprehensive MR algorithm development inclusive of simulations, pulse sequence design and deployment, reconstruction, and image analysis. METHODS:We integrated the "Pulseq" platform for vendor-independent pulse programming with Graphical Programming Interface (GPI)...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2018.03.008

    authors: Ravi KS,Potdar S,Poojar P,Reddy AK,Kroboth S,Nielsen JF,Zaitsev M,Venkatesan R,Geethanath S

    更新日期:2018-10-01 00:00:00

  • Fast reconstruction of highly undersampled MR images using one and two dimensional principal component analysis.

    abstract::Recent compressed sensing techniques allow signal acquisition with less sampling than required by the Nyquist-Shannon theorem which reduces the data acquisition time in magnetic resonance imaging (MRI). However, prior knowledge becomes essential to reconstruct detailed features when the sampling rate is exceedingly lo...

    journal_title:Magnetic resonance imaging

    pub_type: 杂志文章

    doi:10.1016/j.mri.2015.10.009

    authors: Zong F,d'Eurydice MN,Galvosas P

    更新日期:2016-02-01 00:00:00