Magnetic resonance image-based 3D volume interstitial brachytherapy using polyether ether ketone catheters in advanced cervical cancer - a feasibility study.

Abstract:

Purpose:A feasibility study of 3D volume-based interstitial brachytherapy using thermoplastic polyether ether ketone (PEEK) catheters in advanced cervical cancer MR-based brachytherapy, when MR-compatible applicators are not available. Material and methods:Five cervical cancer patients received EBRT dose of 50 Gy in 25 fractions to whole pelvis using 3D conformal radiotherapy after standard pre-treatment evaluation. In our institute, interstitial brachytherapy (ISBT) is planned in BrachyVision TPS and routinely performed using stainless steel needles with Syed-Neblett template. Standard MR-compatible ISBT applicators were not available; therefore, the implant was carried out using PEEK catheters and Syed-Neblett template. The T1 and T2 MR and CT images of patients were acquired for treatment planning. Gross tumor volume (GTV), high-risk clinical target volume (HR-CTV), intermediate-risk clinical target volume (IR-CTV), and organs at risk (OARs) were delineated with the use of MR T2 weighted images, following GEC-ESTRO guidelines. Volumetric optimization was used for planning, and the treatment plan was executed with high-dose-rate (HDR) 192Ir Gammamed Plus device. Results:The dose prescribed to HR-CTV was 30 Gy low-dose-rate (LDR) equivalent (5 Gy × 4 fractions). Doses to target volume and OARs were analyzed using dose volume histogram (DVH). Dose values were biologically normalized to equivalent doses of 2 Gy fractions (EQD2). The average tumor volume was 67 cc and the average D90 of HR-CTV was 29 Gy (5.7 Gy/fraction) EQD2. D100 of HR-CTV volume was 18 Gy (3.8 Gy/fraction) EQD2. The total doses of 2 cc of rectum and bladder were 70 Gy and 76 Gy EQD2 (3.71 Gy and 4.04 Gy dose/fraction), respectively. Conclusions:When the facilities for MR-compatible applicators are not available, MR-based ISBT is feasible with PEEK catheters using available resources for advanced cervical cancer. Doses to HR-CTV and IR-CTV were achieved, restricting doses to OARs as per GEC-ESTRO guidelines.

authors

Palled SR,Tanvirpasha CAR,Naveen T,Sathiyan S,Kadirampatti G,Lokesh V

doi

10.5114/jcb.2019.86975

subject

Has Abstract

pub_date

2019-08-01 00:00:00

pages

307-311

issue

4

eissn

1689-832X

issn

2081-2841

pii

37339

journal_volume

11

pub_type

杂志文章
  • Time to PSA rise differentiates the PSA bounce after HDR and LDR brachytherapy of prostate cancer.

    abstract:Purpose:To investigate the differences in prostate-specific antigen (PSA) bounce (PB) after high-dose-rate (HDR-BT) or low-dose-rate (LDR-BT) brachytherapy alone in prostate cancer patients. Materials and methods:Ninety-four patients with localized prostate cancer (T1-T2cN0), age ranged 50-81 years, were treated with ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.73786

    authors: Burchardt W,Skowronek J

    更新日期:2018-02-01 00:00:00

  • High-dose-rate brachytherapy as monotherapy for localized prostate cancer using three different doses - 14 years of single-centre experience.

    abstract:Purpose:To evaluate clinical outcomes in patients with localized prostate cancer (LPC) treated with 3D conformal high-dose-rate (HDR) brachytherapy (BT) as monotherapy. Material and methods:From March 2004 to November 2017, 277 men with LPC underwent 3D conformal HDR-BT as monotherapy, with a temporary implant. The do...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.101685

    authors: Soatti CP,Delishaj D,D'Amico R,Frigerio C,Fumagalli IC,Bonsignore F,Sangalli G,Declich F,Arcangeli S,Ardizzoia A,Colombo A

    更新日期:2020-12-01 00:00:00

  • A case report of ultrasound-guided interstitial brachytherapy for abdominal wall metastases of ovarian cancer.

    abstract:PURPOSE:To report the treatment effect of interstitial brachytherapy for abdominal wall metastases of ovarian cancer. MATERIAL AND METHODS:The patient is a 44-year-old female with a diagnosis of stage IA ovarian cancer. After surgery and two cycles of chemotherapy with paclitaxel and carboplatin, the patient noticed d...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2015.48574

    authors: Shi D,Wu N,Zhao H,He M,Han D,Cheng G

    更新日期:2015-02-01 00:00:00

  • INTERACTS (INTErventional Radiotherapy ACtive Teaching School) consensus conference on sarcoma interventional radiotherapy (brachytherapy) endorsed by AIRO (Italian Association of Radiotherapy and Clinical Oncology).

    abstract:Purpose:To report the results of INTERACTS (INTErventional Radiotherapy ACtive Teaching School) consensus conference on sarcoma interventional radiotherapy (brachytherapy). Material and methods:An international board of multidisciplinary experts was invited to a consensus conference on the state-of-the-art of sarcoma ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2020.98120

    authors: Tagliaferri L,Vavassori A,Lancellotta V,Sanctis V,Vidali C,Casà C,Aristei C,Genovesi D,Jereczek-Fossa BA,Morganti AG,Kovács G,Guinot JL,Rembielak A,Greto D,Gambacorta MA,Valentini V,Donato V,Corvò R,Magrini SM,Livi

    更新日期:2020-08-01 00:00:00

  • Image fusion techniques in permanent seed implantation.

    abstract::Over the last twenty years major software and hardware developments in brachytherapy treatment planning, intraoperative navigation and dose delivery have been made. Image-guided brachytherapy has emerged as the ultimate conformal radiation therapy, allowing precise dose deposition on small volumes under direct image v...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2010.16920

    authors: Polo A

    更新日期:2010-09-01 00:00:00

  • Dosimetric comparison of graphical optimization and inverse planning simulated annealing for brachytherapy of cervical cancer.

    abstract:Purpose:Graphical optimization (GO) and inverse planning simulated annealing (IPSA) are the main treatment planning optimization techniques used in patients undergoing 3D brachytherapy treatment. This study aims to compare the dosimetric difference of plans optimized by GO and IPSA in cervical cancer brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.87145

    authors: Tang B,Liu X,Wang X,Kang S,Wang P,Li J,Orlandini LC

    更新日期:2019-08-01 00:00:00

  • Effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors.

    abstract:Purpose:This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors. Material and methods:Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to 125I se...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.77957

    authors: Ma X,Yang PZ,Jiang PS,Huo PB,Cao Q,Chai PS,Wang PH

    更新日期:2018-08-01 00:00:00

  • Short-term clinical outcome and dosimetric comparison of tandem and ring versus tandem and ovoids intracavitary applicators.

    abstract:PURPOSE:To compare the short-term toxicity and dosimetry of tandem and ring (TR), and tandem and ovoid (TO) applicators in treatment of gynecologic malignancy. MATERIAL AND METHODS:Following pelvic external beam radiation therapy (EBRT), a total of 52 computed tomography-based plans from 13 patients with cervical canc...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.51853

    authors: Ma JK,Mourad WF,Allbright R,Packianathan S,Harrell LM,Chinchar E,Nguyen A,Vijayakumar S

    更新日期:2015-06-01 00:00:00

  • Does supplemental external beam radiation therapy impact urinary, bowel, and erectile function following permanent prostate brachytherapy?: results of two prospective randomized trials.

    abstract:Purpose:To evaluate the impact of supplemental external beam radiation therapy (EBRT) prior to permanent prostate brachytherapy on long term urinary, bowel, and erectile function. Material and methods:Patient administered urinary, bowel, and erectile quality of life (QoL) instrument were obtained prior to treatment an...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.70763

    authors: Merrick GS,Tennant A,Wallner KE,Galbreath R,Butler WM,Fiano R,Adamovich E

    更新日期:2017-10-01 00:00:00

  • A novel method for vaginal cylinder treatment planning: a seamless transition to 3D brachytherapy.

    abstract:PURPOSE:Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatme...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.29365

    authors: Malhotra HK,Wu V,Wang Z,Patil S

    更新日期:2012-06-01 00:00:00

  • Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer.

    abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.86298

    authors: Walsh A,Hubley E,Doyle L,Cognetti D,Curry J,Bar-Ad V,Luginbuhl A

    更新日期:2019-06-01 00:00:00

  • High-dose-rate brachytherapy in treatment of non-melanoma skin cancer of head and neck region: preliminary results of a prospective single institution study.

    abstract:Purpose:Skin cancers are the most common human malignancy with increasing incidence. Currently, surgery is standard of care treatment for non-melanoma skin cancers. However, brachytherapy is a growing modality in the management of skin cancers. Therefore, we aimed to assess the outcome of patients with non-melanoma ski...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.75596

    authors: Kalaghchi B,Esmati E,Ghalehtaki R,Gomar M,Jaberi R,Gholami S,Babaloui S,Nabavi M,Sotoudeh S,Khanjani N,Kazemian A,Amouzegar-Hashemi F,Aghili M,Lashkari M

    更新日期:2018-04-01 00:00:00

  • Dosimetric comparison of Acuros™ BV with AAPM TG43 dose calculation formalism in breast interstitial high-dose-rate brachytherapy with the use of metal catheters.

    abstract:PURPOSE:Radiotherapy for breast cancer includes different techniques and methods. The purpose of this study is to compare dosimetric calculations using TG-43 dose formalism and Varian Acuros™ BV (GBBS) dose calculation algorithm for interstitial implant of breast using metal catheters in high-dose-rate (HDR) brachyther...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.54052

    authors: Sinnatamby M,Nagarajan V,Reddy K S,Karunanidhi G,Singhavajala V

    更新日期:2015-08-01 00:00:00

  • Pain relief procedures before high-dose-rate brachytherapy for non-surgical treatment of cervix cancer.

    abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2018.81027

    authors: Pellizzon ACA

    更新日期:2018-12-01 00:00:00

  • Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer.

    abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.72581

    authors: Akiyama H,Major T,Polgár C,Takácsi-Nagy Z

    更新日期:2017-12-01 00:00:00

  • Evaluation of interpolation methods for TG-43 dosimetric parameters based on comparison with Monte Carlo data for high-energy brachytherapy sources.

    abstract:PURPOSE:The aim of this work was to determine dose distributions for high-energy brachytherapy sources at spatial locations not included in the radial dose function gL(r) and 2D anisotropy function F(r,θ) table entries for radial distance r and polar angle θ. The objectives of this study are as follows: 1) to evaluate ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.13715

    authors: Pujades-Claumarchirant MC,Granero D,Perez-Calatayud J,Ballester F,Melhus C,Rivard M

    更新日期:2010-03-01 00:00:00

  • The use of nomograms in LDR-HDR prostate brachytherapy.

    abstract:PURPOSE:The common use of nomograms in Low Dose Rate (LDR) permanent prostate brachytherapy (BT) allows to estimate the number of seeds required for an implant. Independent dosimetry verification is recommended for each clinical dosimetry in BT. Also, nomograms can be useful for dose calculation quality assurance and t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2011.24817

    authors: Pujades MC,Camacho C,Perez-Calatayud J,Richart J,Gimeno J,Lliso F,Carmona V,Ballester F,Crispín V,Rodríguez S,Tormo A

    更新日期:2011-09-01 00:00:00

  • Coverage with dosimetric concordance index (CDCI): a tool for evaluating dosimetric impact of inter-observer target variability in brachytherapy.

    abstract:Purpose:The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy. Material and methods:The coverage with dosimetric concordance index (CDCI) is expressed as CDCIcommon and CDCIpair. The CDCIcommon is the mean coverage of target vol...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2020.94309

    authors: Upreti RR,Budrukkar A,Upreti U,Wadasadawala T,Pathak R,Misra S,Gurrum L,Kinhikar RA,Deshpande DD

    更新日期:2020-04-01 00:00:00

  • Reduction of applicator displacement in MR/CT-guided cervical cancer HDR brachytherapy by the use of patient hover transport system.

    abstract:Purpose:To quantify the reduction of relative displacement between the implanted intracavitary applicator and the patient bony anatomy, due to the use of a hover transport system during the patient transports between the imaging table and the treatment table. Material and methods:The displacement of the applicator ins...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.73755

    authors: Andrew M,Kim Y,Ginader T,Smith BJ,Sun W,Wang D

    更新日期:2018-02-01 00:00:00

  • High-dose-rate interstitial brachytherapy for liver metastases: first study from India.

    abstract:PURPOSE:To study the safety and efficacy of high-dose-rate interstitial brachytherapy (HDRIBT) in patients with liver metastases (LM). MATERIAL AND METHODS:Between 2009 and 2011, 10 patients with 12 metastatic lesions in the liver were enrolled in this prospective trial. All patients had either refused surgery or foun...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.36175

    authors: Sharma DN,Thulkar S,Sharma S,Gandhi AK,Haresh KP,Gupta S,Rath GK,Julka PK

    更新日期:2013-06-01 00:00:00

  • HDR brachytherapy as a solution in recurrences of locally advanced prostate cancer.

    abstract:PURPOSE:The object of this study was to analyze the outcome of salvage HDR brachytherapy treatment after local failure, for patients with prostate specific antigen (PSA) failure without distant metastasis, after external beam radiation and HDR brachytherapy treatment, or after radical prostatectomy, with or without hor...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:

    authors: Łyczek J,Kawczyńska MM,Garmol D,Kasprowicz A,Kulik A,Dąbkowski M,Czyżew B,Gruszczyńska E,Bijok M,Kowalik Ł

    更新日期:2009-06-01 00:00:00

  • A comparison of dose distribution from Manchester-style and Fletcher-style intracavitary brachytherapy applicator systems in cervical cancer.

    abstract:PURPOSE:During intracavitary brachytherapy (ICBT) for cervical cancer, the choice of applicator system remains rather arbitrary. However, as the applicator geometry may play an important role in dose distribution, thereby improving the therapeutic ratio, this study was conducted to compare the Manchester-style and Flet...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.32555

    authors: Basu B,Basu S,Chakraborti B,Ghorai S,Gupta P,Ghosh S,Ghosh K,Jayanti J

    更新日期:2012-12-01 00:00:00

  • Current state of interventional radiotherapy (brachytherapy) education in Italy: results of the INTERACTS survey.

    abstract:Purpose:Increased complexity of interventional radiotherapy (brachytherapy - BT) treatment planning and quality control procedures has led to the need of a specific training. However, the details of the features of BT learning objectives and their distribution in the training paths of the Italian Radiation Oncology Sch...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2019.83137

    authors: Tagliaferri L,Kovács G,Aristei C,De Sanctis V,Barbera F,Morganti AG,Casà C,Pieters BR,Russi E,Livi L,Corvò R,Giovagnoni A,Ricardi U,Valentini V,Magrini SM,Directors of the Italian Radiation Oncology Schools.

    更新日期:2019-02-01 00:00:00

  • Time to failure after definitive therapy for prostate cancer: implications for importance of aggressive local treatment.

    abstract:PURPOSE:To explore patterns of time to failure in men receiving high doses of permanent seed brachytherapy with or without external beam radiation therapy as a function of risk status. MATERIAL AND METHODS:Two thousand two hundred and thirty four patients were treated with prostate brachytherapy with median follow up ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.39210

    authors: Taira AV,Merrick GS,Butler WM,Galbreath RW,Fiano R,Wallner KE,Adamovich E

    更新日期:2013-12-01 00:00:00

  • Dosimetry verification of 3D-printed individual template based on CT-MRI fusion for radioactive 125I seed implantation in recurrent high-grade gliomas.

    abstract:Purpose:To verify the accuracy and efficacy of three-dimensional printing individual template (3D-PIT) with computed tomography-magnetic resonance imaging (CT-MRI) fusion for radioactive iodine-125 (125I) seed implantation in high-grade brain gliomas. Material and methods:Between June 2017 and June 2018, 16 patients w...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.85729

    authors: Liu S,Wang H,Wang C,Zhang H,Li W,Dong Q,Hu X

    更新日期:2019-06-01 00:00:00

  • High-dose-rate interstitial brachytherapy with hypoxic radiosensitizer KORTUC II for unresectable pelvic sidewall recurrence of uterine cervical cancer: a case report.

    abstract::In order to improve oncologic outcomes in radiotherapy treatments of patients with unresectable pelvic sidewall recurrences of uterine cervical cancer, we combined high-dose-rate interstitial brachytherapy (HDR-ISBT) with newly tested hypoxic radiosensitizer Kochi oxydol-radiation therapy for unresectable carcinomas (...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.101695

    authors: Nakata M,Yoshida K,Shimbo T,Yoshikawa N,Yoshioka H,Hori A,Sato C,Uesugi Y,Kogata Y,Masui K,Murakami N,Kashihara T,Akiyama H,Tselis N,Ohmichi M,Nihei K

    更新日期:2020-12-01 00:00:00

  • Prostate brachytherapy procedural training: incorporation of related procedures in resident training and competency assessment.

    abstract:Purpose:Inadequate procedural training is of increasing concern in resident training, especially in prostate brachytherapy (PB). Transperineal rectal spacer placement (TRSP) requires many of the same proficiencies as PB. This work describes the assessment of teaching techniques focusing on developing critical competenc...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.90984

    authors: Bachand J,Schroeder SR,Desai NB,Folkert MR

    更新日期:2019-12-01 00:00:00

  • The impact of activating source dwell positions outside the CTV on the dose to treated normal tissue volumes in TRUS guided 3D conformal interstitial HDR brachytherapy of prostate cancer.

    abstract:PURPOSE:Dose coverage is crucial for successful treatment in mono-brachytherapy. Since few and very high dose fractions are used, there is an important balance between dwell positioning outside the clinical target volume (CTV) and possible damage on adjacent normal tissue. The purpose of this study was to evaluate the ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.45586

    authors: Karlsson L,Thunberg P,Johansson B,Persliden J

    更新日期:2014-10-01 00:00:00

  • Combined interstitial and surface high-dose-rate brachytherapy treatment of squamous cell carcinoma of the hand.

    abstract:Purpose:We present a case report of treatment using interstitial and surface high-dose-rate (HDR) brachytherapy for cutaneous squamous cell carcinoma (SCC) involving the interspace of the third and fourth digits. The patient refused two-ray amputation and the lesion was not amenable for external beam radiation therapy ...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.92408

    authors: Kim DW,Buzurovic IM,Mahal BV,Hwang W,Oladeru OT,O'Farrell DA,Harris TC,Margalit DN,Lam M,Devlin PM

    更新日期:2020-02-01 00:00:00

  • Non-melanoma skin cancer treated with high-dose-rate brachytherapy and Valencia applicator in elderly patients: a retrospective case series.

    abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. Basal cell carcinoma and squamous cell carcinoma are the two most common subtypes of NMSC. The aim of this study was to estimate tumour control, toxicity, and aesthetic events in elderly patients treated with high-dose-...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.55746

    authors: Delishaj D,Laliscia C,Manfredi B,Ursino S,Pasqualetti F,Lombardo E,Perrone F,Morganti R,Paiar F,Fabrini MG

    更新日期:2015-12-01 00:00:00