Adapting the Aerogen Mesh Nebulizer for Dried Aerosol Exposures Using the PreciseInhale Platform.

Abstract:

: Background: Many substances used in inhalation research are water soluble and can be administered as nebulized solutions. Typical examples are therapeutic, small-molecular agents, or macromolecules. Another category is a number of water-soluble agents used for airway diagnostics or disease modeling. Mesh nebulizers have facilitated well-controlled liquid aerosol exposures. Meanwhile, a benchtop inhalation platform, PreciseInhale, was developed for providing small-scale, well-controlled aerosol exposures in preclinical configurations. The purpose of the current research was to adapt the Aerogen mesh nebulizer to work within the PreciseInhale system for both cell culture and rodent exposures. Methods: The wet aerosols produced with the Aerogen Pro nebulizer were dried out in an aerosol holding chamber by supplying dry carrier air, which was provided by passing the incoming ambient air through a column with silica gel. The nebulizer was installed in an aerosol holding chamber between an upstream flow-rate pneumotach and a downstream aerosol monitor. By pulsing, the nebulizer output was reduced to 1%-10% of continuous operation to better match the exposure ventilation requirements. Additional drying was obtained by mantling the holding chamber with dried paper. Results and Conclusions: The nebulizer output was reduced to 3-30 μL/min and dried out before reaching the in vitro or in vivo exposure modules. Using solute concentrations in the range of 0.5%-2% (w/w), dried aerosols were produced with a mass median aerodynamic diameter of 1.5-2.0 μm, compared to the 4-5 μm droplets emitted by the nebulizer. Controlling the Aerogen nebulizer under a reduced output scheme within the PreciseInhale platform gave two major advantages: (i) by reducing aerosol output to better match exposure flow rates of single rodents, increased airway deposition yields were obtained in a range of 1%-10% relative to the nebulized amount of test substance and (ii) shrinking aerosol particle sizes through drying improved the peripheral lung deposition of test aerosols.

authors

Gerde P,Nowenwik M,Sjöberg CO,Selg E

doi

10.1089/jamp.2019.1554

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

116-126

issue

2

eissn

1941-2711

issn

1941-2703

journal_volume

33

pub_type

杂志文章
  • Correcting Photo Reflection Method Output and Its Application in the Dynamic Analysis of Particle Release from Dry Powder Inhalers.

    abstract:: Background: The photo reflection method (PRM) is used to measure light reflected from particles released from dry powder inhalers (DPIs). This simple method depicts time trajectories of released drugs; however, it underestimates the number of particles at high peak inhalat...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1610

    authors: Kondo T,Hibino M,Tanigaki T,Tajiri S,Horiuchi S

    更新日期:2020-11-04 00:00:00

  • Investigation of Lung Pharmacokinetic of the Novel PDE4 Inhibitor CHF6001 in Preclinical Models: Evaluation of the PreciseInhale Technology.

    abstract:BACKGROUND:Preclinical evaluation of new chemical entities (NCEs) designed to be administered by inhalation route requires lung administration to rodents, especially in the discovery phase. Different administration methods have been used until now, but more efforts are required to obtain controlled and reproducible lun...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1369

    authors: Fioni A,Selg E,Cenacchi V,Acevedo F,Brogin G,Gerde P,Puccini P

    更新日期:2018-02-01 00:00:00

  • Development of an in vitro model to assess deposition of aerosol particles in a representative replica of the rat's respiratory tract.

    abstract:BACKGROUND:Small rodents continue to be the mainstay for the assessment of pharmacological and toxicological data of inhaled therapeutics. For meaningful interpretation of the results information about deposition of aerosol particles in the respiratory tract is warranted, but not trivial to obtain for animals with nose...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0902

    authors: Ahmed A,Prime D,Burnell PK,Högger P

    更新日期:2012-06-01 00:00:00

  • A New Quantitative Method for Evaluating Dry Powder Inhalation Efficiency in Asthma Patients.

    abstract:PURPOSE:Many methods have been developed to evaluate dry powder inhalation techniques and their efficiency for disease control in asthma patients. However, it is difficult to apply these methods to clinical practice and research. In this study, we introduce a simple new method that can be applied to dry powder inhalati...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1193

    authors: Liang Y,Hu H,Tian C,Lei Y,Liu C,Luo F

    更新日期:2016-10-01 00:00:00

  • Use of a Remote Inhaler Monitoring Device to Measure Change in Inhaler Use with Chronic Obstructive Pulmonary Disease Exacerbations.

    abstract:BACKGROUND:Remote inhaler monitoring is an emerging technology that enables the healthcare team to monitor the time and location of a patient's inhaler use. We assessed the feasibility of remote inhaler monitoring for chronic obstructive pulmonary disease (COPD) patients and the pattern of albuterol inhaler use associa...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1383

    authors: Sumino K,Locke ER,Magzamen S,Gylys-Colwell I,Humblet O,Nguyen HQ,Thomas RM,Fan VS

    更新日期:2018-06-01 00:00:00

  • Characterization of Medication Velocity and Size Distribution from Pressurized Metered-Dose Inhalers by Phase Doppler Anemometry.

    abstract:BACKGROUND:Particle size and velocity are two of the most significant factors that impact the deposition of pressurized metered-dose inhaler (pMDI) sprays in the mouth cavity. pMDIs are prominently used around the world in the treatment of patients suffering from a variety of lung diseases such as asthma and chronic ob...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1264

    authors: Alatrash A,Matida E

    更新日期:2016-12-01 00:00:00

  • Sustained mechanical and clinical functionality of the flexhaler dry powder inhaler.

    abstract::Flexhaler is a multiple-dose, inspiratory flow-driven dry powder inhaler that is a newer version of Turbuhaler, and is identical to the Symbicort Turbuhaler. Sustained performance is of the utmost importance to ensure consistent drug delivery throughout the lifespan of the inhaler. We report functionality testing resu...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0700

    authors: Lööf T,Elfman P,Ström P,Törngren A,Borgström L

    更新日期:2008-12-01 00:00:00

  • A Novel In-Line Delivery System to Administer Dry Powder Mannitol to Mechanically Ventilated Patients.

    abstract:BACKGROUND:Mechanically ventilated patients commonly suffer from ventilator-associated pneumonia, hypoxemia, and other lower respiratory tract infection as a result of pathogen colonization and poor sputum clearance. Consequently, there is a high rate of morbidity and mortality in these patients. Dry powder mannitol in...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2016.1320

    authors: Feng B,Tang P,Leung SS,Dhanani J,Chan HK

    更新日期:2017-04-01 00:00:00

  • Aerosolizing Lipid Dispersions Enables Antibiotic Transport Across Mimics of the Lung Airway Surface Even in the Presence of Pre-existing Lipid Monolayers.

    abstract:BACKGROUND:Secondary lung infections are the primary cause of morbidity associated with cystic fibrosis lung disease. Aerosolized antibiotic inhalation is potentially advantageous but has limited effectiveness due to altered airway aerodynamics and deposition patterns that limit drug access to infected regions. One pot...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2017.1412

    authors: Iasella SV,Stetten AZ,Corcoran TE,Garoff S,Przybycien TM,Tilton RD

    更新日期:2018-08-01 00:00:00

  • Optimal delivery of aerosols to infants during mechanical ventilation.

    abstract:PURPOSE:The objective of this study was to determine optimal aerosol delivery conditions for a full-term (3.6 kg) infant receiving invasive mechanical ventilation by evaluating the effects of aerosol particle size, a new wye connector, and timing of aerosol delivery. METHODS:In vitro experiments used a vibrating mesh ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2013.1077

    authors: Longest PW,Azimi M,Hindle M

    更新日期:2014-10-01 00:00:00

  • Pulmonary formulations: what remains to be done?

    abstract::Significant advances have been made in the last 50 years in developing safe and efficacious aerosol formulations for pulmonary delivery. The key to future innovation may lie at the interface between biology and particle engineering. Improved understanding of biological processes including particle clearance, cellular ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2010.0838

    authors: Weers JG,Bell J,Chan HK,Cipolla D,Dunbar C,Hickey AJ,Smith IJ

    更新日期:2010-12-01 00:00:00

  • Collecting exhaled breath condensate (EBC) with two condensers in series: a promising technique for studying the mechanisms of EBC formation, and the volatility of selected biomarkers.

    abstract::Exhaled breath condensate (EBC) consists mainly of water, but also contains semivolatile and nonvolatile compounds. The aim of this study was to develop a system in which two condensers are simultaneously used in series to clarify the mechanisms of EBC condensation. Two aliquots of EBC (EBC1 and EBC2) were collected f...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2007.0644

    authors: Corradi M,Goldoni M,Caglieri A,Folesani G,Poli D,Corti M,Mutti A

    更新日期:2008-03-01 00:00:00

  • Community Masks During the SARS-CoV-2 Pandemic: Filtration Efficacy and Air Resistance.

    abstract:: Background: Many countries have introduced a compulsory use of community masks for certain public areas during the SARS-CoV-2 pandemic. Different manufacturers offer reusable community masks in large quantities. The efficacy of these masks, however, is unknown. ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.1635

    authors: Maurer L,Peris D,Kerl J,Guenther F,Koehler D,Dellweg D

    更新日期:2020-09-23 00:00:00

  • The effects of training on inhaler technique and quality of life in patients with COPD.

    abstract:OBJECTIVES:This experimental study was conducted to determine the effects of training on inhaler technique and quality of life in patients with chronic obstructive pulmonary disease (COPD). METHODS:Among the patients who applied at the outpatient clinic of chest diseases between March 2009 and May 2010, a total of 69 ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2012.1017

    authors: Göriş S,Taşci S,Elmali F

    更新日期:2013-12-01 00:00:00

  • Adapting the Abbreviated Impactor Measurement (AIM) concept to make appropriate inhaler aerosol measurements to compare with clinical data: a scoping study with the "Alberta" idealized throat (AIT) inlet.

    abstract:BACKGROUND:The Abbreviated Impactor Measurement (AIM) concept simplifies determination of aerodynamic size metrics for inhaler quality control testing. A similar approach is needed to compare in vitro particle size distribution metrics with human respiratory tract (HRT) deposition. METHODS:An abbreviated impactor base...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2011.0925

    authors: Mitchell J,Copley M,Sizer Y,Russell T,Solomon D

    更新日期:2012-08-01 00:00:00

  • Validation of the 'Test of the Adherence to Inhalers' (TAI) for Asthma and COPD Patients.

    abstract:BACKGROUND:To validate the 'Test of Adherence to Inhalers' (TAI), a 12-item questionnaire designed to assess the adherence to inhalers in patients with COPD or asthma. METHODS:A total of 1009 patients with asthma or COPD participated in a cross-sectional multicenter study. Patients with electronic adherence ≥80% were ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,多中心研究

    doi:10.1089/jamp.2015.1212

    authors: Plaza V,Fernández-Rodríguez C,Melero C,Cosío BG,Entrenas LM,de Llano LP,Gutiérrez-Pereyra F,Tarragona E,Palomino R,López-Viña A,TAI Study Group.

    更新日期:2016-04-01 00:00:00

  • Factors Determining In Vitro Lung Deposition of Albuterol Aerosol Delivered by Ventolin Metered-Dose Inhaler.

    abstract:BACKGROUND:The effectiveness of metered-dose inhalers (MDIs) in delivering medication to the lungs highly depends on its correct usage technique. Current guidelines state optimal technique for high lung deposition should include a slow inhalation (>5 seconds) at an inspiratory flow rate of 30 L/min and inhaler actuatio...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1278

    authors: Biswas R,Hanania NA,Sabharwal A

    更新日期:2017-08-01 00:00:00

  • Age-dependent deterioration of peak inspiratory flow with two kinds of dry powder corticosteroid inhalers (Diskus and Turbuhaler) and relationships with asthma control.

    abstract:BACKGROUND:Inhaled corticosteroid (ICS) therapy has improved the quality of life (QOL) for many asthmatics and reduced mortality rates associated with asthma. However, some patients do not obtain therapeutic benefit despite satisfactory adherence. OBJECTIVES:To determine whether asthmatic patients were using ICS devic...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2010.0868

    authors: Baba K,Tanaka H,Nishimura M,Yokoe N,Takahashi D,Yagi T,Yamaguchi E,Maeda Y,Muto T,Hasegawa T

    更新日期:2011-12-01 00:00:00

  • Single-dose pharmacokinetics and safety pharmacodynamics of formoterol delivered by two different dry powder inhalers.

    abstract::The present study aimed at assessing the pharmacokinetics (PK) and safety pharmacodynamics (PD) of 24 microg formoterol delivered via a Novolizer and via an Aerolizer in healthy subjects. This was a randomized, open-label, crossover study. Beside PK, serum potassium, and glucose profiles, vital signs, and ECG were rec...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,随机对照试验

    doi:10.1089/jamp.2008.0690

    authors: Petzold U,Kremer HJ,Nguyen DT,Munzel U,Dietrich H,Maus J

    更新日期:2008-09-01 00:00:00

  • Controlled, Parametric, Individualized, 2-D and 3-D Imaging Measurements of Aerosol Deposition in the Respiratory Tract of Asthmatic Human Subjects for Model Validation.

    abstract:BACKGROUND:Computer modeling is used to predict inhaled aerosol deposition in the lung based on definition of the aerosol characteristics and the breathing pattern and airway anatomy of the subject. Validation of the models is limited by the lack of detailed experimental data. Three-dimensional imaging provides an oppo...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1191

    authors: Fleming J,Conway J,Majoral C,Katz I,Caillibotte G,Pichelin M,Montesantos S,Bennett M

    更新日期:2015-12-01 00:00:00

  • Intranasal Deposition of Accuspray™ Aerosol in Anatomically Correct Models of 2-, 5-, and 12-Year-Old Children.

    abstract:BACKGROUND:To our knowledge, quantification of intranasal deposition of aerosol generated by Accuspray(™) (AS) in children has never been published. We hypothesized that deposition would vary significantly with age and with placement of the device within, or outside, of the nostril. METHODS:We tested these hypotheses ...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2014.1174

    authors: Laube BL,Sharpless G,Vikani AR,Harrand V,Zinreich SJ,Sedberry K,Knaus D,Barry J,Papania M

    更新日期:2015-10-01 00:00:00

  • The co-imaging of gamma camera measurements of aerosol deposition and respiratory anatomy.

    abstract::The use of gamma camera imaging following the inhalation of a radiolabel has been widely used by researchers to investigate the fate of inhaled aerosols. The application of two-dimensional (2D) planar gamma scintigraphy and single-photon emission computed tomography (SPECT) to the study of inhaled aerosols is discusse...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0960

    authors: Conway J,Fleming J,Bennett M,Havelock T

    更新日期:2013-06-01 00:00:00

  • Evaluation of the Respimat Soft Mist Inhaler using a concurrent CFD and in vitro approach.

    abstract:BACKGROUND:The Respimat Soft Mist Inhaler is reported to generate an aerosol with low spray momentum and a small droplet size. However, the transport characteristics of the Respimat aerosol are not well understood. The objective of this study was to characterize the transport and deposition of an aerosol emitted from t...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0708

    authors: Worth Longest P,Hindle M

    更新日期:2009-06-01 00:00:00

  • Aerosol Therapy in Adults Receiving High Flow Nasal Cannula Oxygen Therapy.

    abstract:BACKGROUND:High flow nasal cannula oxygen therapy (HFT) is increasingly used in intensive and emergency care departments. Patients suffering from respiratory failure, who are likely to benefit from HFT, may require aerosolized bronchodilators; therefore, combining nebulization with HFT may be relevant. This study aimed...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1219

    authors: Réminiac F,Vecellio L,Heuzé-Vourc'h N,Petitcollin A,Respaud R,Cabrera M,Pennec DL,Diot P,Ehrmann S

    更新日期:2016-04-01 00:00:00

  • Deposition Mechanisms.

    abstract::The success of inhalation therapy is not only dependent upon the pharmacology of the drugs being inhaled but also upon the site and extent of deposition in the respiratory tract. Similarly, the toxicity of environmental and industrial particulate matter is affected not only by the nature of the dust but also by the am...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2020.29029.cd

    authors: Darquenne C

    更新日期:2020-08-01 00:00:00

  • Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions.

    abstract:BACKGROUND:Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and T...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1216

    authors: Canonica GW,Arp J,Keegstra JR,Chrystyn H

    更新日期:2015-10-01 00:00:00

  • Evaluation of comparative performance of orally inhaled drug products in view of the classical bioequivalence paradigms: an analysis of the current scientific and regulatory dilemmas of inhaler evaluation.

    abstract::Since the early 1960s, there has been a continuous evolution in scientific understanding regarding bioequivalence (BE) of oral dosage forms, intermittently punctuated by some breakthrough research findings and conceptual advances. The accumulated knowledge from this body of research has been translated into a sophisti...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2014.1144

    authors: Horhota ST

    更新日期:2014-12-01 00:00:00

  • Toward modern inhalational bacteriophage therapy: nebulization of bacteriophages of Burkholderia cepacia complex.

    abstract::Antibiotic-resistant bacterial infections have renewed interest in finding substitute methods of treatment. The purpose of the present in vitro study was to investigate the possibility of respiratory delivery of a Burkholderia cepacia complex (BCC) bacteriophage by nebulized aerosol administration. Bacteriophages in i...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2008.0701

    authors: Golshahi L,Seed KD,Dennis JJ,Finlay WH

    更新日期:2008-12-01 00:00:00

  • An Apparatus to Deliver Mannitol Powder for Bronchial Provocation in Children Under Six Years Old.

    abstract:BACKGROUND:Currently bronchial provocation testing (BPT) using mannitol powder cannot be performed in children under 6 years. A primary reason is it is challenging for children at this age to generate a consistent inspiratory effort to inhale mannitol efficiently from a dry powder inhaler. A prototype system, which doe...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章

    doi:10.1089/jamp.2015.1208

    authors: Tang P,Leung SS,Hor E,Ruzycki CA,Carrigy NB,Finlay WH,Brannan JD,Devadason S,Anderson SD,Sly PD,Samnick K,Chan HK

    更新日期:2015-12-01 00:00:00

  • Using MRI to measure aerosol deposition.

    abstract::This article provides a concise review of the use of magnetic resonance imaging (MRI) for measurement of regional aerosol deposition in the lungs. Basic aspects of MRI and its use in lung imaging and measurement of regional ventilation are introduced. Imaging of hydrogen protons (water) and inhaled hyperpolarized gase...

    journal_title:Journal of aerosol medicine and pulmonary drug delivery

    pub_type: 杂志文章,评审

    doi:10.1089/jamp.2011.0897

    authors: Thompson RB,Finlay WH

    更新日期:2012-04-01 00:00:00