Coverage with dosimetric concordance index (CDCI): a tool for evaluating dosimetric impact of inter-observer target variability in brachytherapy.

Abstract:

Purpose:The aim of this study was to propose an index for evaluating dosimetric impact of inter-observer target delineation variability in brachytherapy. Material and methods:The coverage with dosimetric concordance index (CDCI) is expressed as CDCIcommon and CDCIpair. The CDCIcommon is the mean coverage of target volume with common volume irradiated by prescription dose among all observers and represents the condition of worst target coverage. CDCIpair is the generalized form of CDCI, which is mean target coverage with common prescription volume obtained between all possible pairs of observers and represents more realistic coverage of target with dosimetric concordance. The index was used to evaluate the dosimetric impact of target delineation variability in optimized conformal plans on target volumes of five radiation oncologists for twenty patients of multi-catheter interstitial partial breast brachytherapy. Results:The mean decline of 5.6 ±3.2% and 11.3 ±5.7% in CDCIpair and CDCIcommon, respectively, was observed comparing to coverage index (CI) of target volume in all patients due to inter-observer target variability. CDCIcommon and CDCIpair were found to have significant linear correlation (r = 0.964, p < 0.000). The difference between CDC and CI increased with the mean relative target volume among observers. Significant correlation (r = 0.962, p < 0.000) was also noted for the difference (Δ) in CDCIcommon and CDCIpair with CI of target volume. Conclusions:The recommended indices and difference between the dosimetric coverage of target volume (CI) with CDCI (ΔCDCI) can be used for evaluating dosimetric impact of the inter-observer target delineation variability.

authors

Upreti RR,Budrukkar A,Upreti U,Wadasadawala T,Pathak R,Misra S,Gurrum L,Kinhikar RA,Deshpande DD

doi

10.5114/jcb.2020.94309

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

160-165

issue

2

eissn

1689-832X

issn

2081-2841

pii

40327

journal_volume

12

pub_type

杂志文章
  • Artificial intelligence (AI) and interventional radiotherapy (brachytherapy): state of art and future perspectives.

    abstract:Purpose:Artificial intelligence (AI) plays a central role in building decision supporting systems (DSS), and its application in healthcare is rapidly increasing. The aim of this study was to define the role of AI in healthcare, with main focus on radiation oncology (RO) and interventional radiotherapy (IRT, brachythera...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2020.100384

    authors: Fionda B,Boldrini L,D'Aviero A,Lancellotta V,Gambacorta MA,Kovács G,Patarnello S,Valentini V,Tagliaferri L

    更新日期:2020-10-01 00:00:00

  • Dose-volume analysis of target volume and critical structures in computed tomography image-based multicatheter high-dose-rate interstitial brachytherapy for head and neck cancer.

    abstract:Purpose:To evaluate dose-volume relationships of target volume and critical structures in computed tomography (CT) image-based brachytherapy for head and neck cancer. Material and methods:Thirty-seven patients with mobile tongue, floor of mouth, and base of tongue cancer treated with brachytherapy (post-operative alon...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.72581

    authors: Akiyama H,Major T,Polgár C,Takácsi-Nagy Z

    更新日期:2017-12-01 00:00:00

  • The evolution of computerized treatment planning for brachytherapy: American contributions.

    abstract:PURPOSE:To outline the evolution of computerized brachytherapy treatment planning in the United States through a review of technological developments and clinical practice refinements. MATERIAL AND METHODS:A literature review was performed and interviews were conducted with six participants in the development of compu...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2014.43131

    authors: Aronowitz JN,Rivard MJ

    更新日期:2014-06-01 00:00:00

  • Comparison of three different techniques of low-dose-rate seed implantation for prostate cancer.

    abstract:PURPOSE:Three different techniques of low-dose-rate seed implantation for prostate cancer have been used since its use started in our hospital. The purpose of this study was to compare the results of the three different techniques. MATERIAL AND METHODS:The data of 305 prostate cancer patients who underwent low-dose-ra...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2015.48603

    authors: Ishiyama H,Satoh T,Sekiguchi A,Tabata K,Komori S,Tsumura H,Kawakami S,Soda I,Takenaka K,Iwamura M,Hayakawa K

    更新日期:2015-02-01 00:00:00

  • A comparative study of two reconstructive methods and different recommendations in intracavitary brachytherapy.

    abstract:PURPOSE:Intracavitary brachytherapy (ICB) is a widely used technique in the treatment of cervical cancer. In our Institute, we use different reconstructive methods in the conventional planning procedure. The main aim of this study was to compare these methods using critical organ doses obtained in various treatment pla...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2010.19498

    authors: Sresty NM,Ramanjappa T,Rao CR,Raju AK,Muralidhar KR

    更新日期:2010-12-01 00:00:00

  • A novel method for vaginal cylinder treatment planning: a seamless transition to 3D brachytherapy.

    abstract:PURPOSE:Standard treatment plan libraries are often used to ensure a quick turn-around time for vaginal cylinder treatments. Recently there is increasing interest in transitioning from conventional 2D radiograph based brachytherapy to 3D image based brachytherapy, which has resulted in a substantial increase in treatme...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2012.29365

    authors: Malhotra HK,Wu V,Wang Z,Patil S

    更新日期:2012-06-01 00:00:00

  • Does supplemental external beam radiation therapy impact urinary, bowel, and erectile function following permanent prostate brachytherapy?: results of two prospective randomized trials.

    abstract:Purpose:To evaluate the impact of supplemental external beam radiation therapy (EBRT) prior to permanent prostate brachytherapy on long term urinary, bowel, and erectile function. Material and methods:Patient administered urinary, bowel, and erectile quality of life (QoL) instrument were obtained prior to treatment an...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.70763

    authors: Merrick GS,Tennant A,Wallner KE,Galbreath R,Butler WM,Fiano R,Adamovich E

    更新日期:2017-10-01 00:00:00

  • A comparison study on various low energy sources in interstitial prostate brachytherapy.

    abstract:PURPOSE:Low energy sources are routinely used in prostate brachytherapy. (125)I is one of the most commonly used sources. Low energy (131)Cs source was introduced recently as a brachytherapy source. The aim of this study is to compare dose distributions of (125)I, (103)Pd, and (131)Cs sources in interstitial brachyther...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.57708

    authors: Bakhshabadi M,Ghorbani M,Khosroabadi M,Knaup C,Meigooni AS

    更新日期:2016-02-01 00:00:00

  • Brachytherapy in paediatric malignancies - review of indications.

    abstract::Paediatric malignancies are relatively rare, with an annual frequency of 13-14 in 100 000 children up to 15 years, and account for less than 1% of all cancer in developed countries. Paediatric tumours are generally managed with a multi-modality treatment programme that includes surgery, chemotherapy, and external beam...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2010.14407

    authors: Fijuth J

    更新日期:2010-06-01 00:00:00

  • Patterns of cervical cancer brachytherapy in India: results of an online survey supported by the Indian Brachytherapy Society.

    abstract:Purpose:Cervical cancer is the most common gynecological cancer in India. Uniform protocol-based treatment is important for achieving optimal outcomes. We undertook a survey to investigate patterns of care with special regard to patterns of care in cervical cancer brachytherapy in India. Material and methods:A 17-ques...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.90448

    authors: Chatterjee A,Grover S,Gurram L,Sastri S,Mahantshetty U

    更新日期:2019-12-01 00:00:00

  • Comparison of prostate contours between conventional stepping transverse imaging and Twister-based sagittal imaging in permanent interstitial prostate brachytherapy.

    abstract:PURPOSE:To compare prostate contours on conventional stepping transverse image acquisitions with those on twister-based sagittal image acquisitions. MATERIAL AND METHODS:Twenty prostate cancer patients who were planned to have permanent interstitial prostate brachytherapy were prospectively accrued. A transrectal ultr...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.69807

    authors: Kawakami S,Ishiyama H,Satoh T,Tsumura H,Sekiguchi A,Takenaka K,Tabata KI,Iwamura M,Hayakawa K

    更新日期:2017-08-01 00:00:00

  • An evaluation of the robustness of organ-at-risk recommendations made by GEC/ESTRO according to interobserver variability: a single-center experience.

    abstract:PURPOSE:Groupe Européen de Curiethérapie (GEC) and European Society for Radiotherapy & Oncology (ESTRO) has proposed a rectal dose constraint of the most exposed 2-cc volume (D2cc of ≤ 75 Gy EQD2α/β = 3) during external-beam plus high-dose-rate brachytherapy (HDR-BT) in localized prostate cancer patients. This study ai...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.61738

    authors: Chicas-Sett R,Celada-Alvarez F,Roldán S,Torregrosa A,Betancourt J,Bautista-Ballesteros J,Farga D,Ibañez B,Tormo A,Perez-Calatayud J

    更新日期:2016-08-01 00:00:00

  • The impact of inter-fraction changes for perineal template-based interstitial gynecologic brachytherapy implants.

    abstract:Purpose:Perineal template-based interstitial gynecologic brachytherapy (ISBT) treatments are evaluated to determine whether adaptive inter-fraction re-planning is beneficial and necessary to meet the treatment aims of the American Brachytherapy Society (ABS) consensus guidelines for interstitial brachytherapy. Adherenc...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.84420

    authors: Belliveau JG,Thind K,Banerjee R,Quirk S,Doll C,Phan T,Meyer T,Roumeliotis M

    更新日期:2019-04-01 00:00:00

  • Staged reconstruction brachytherapy has lower overall cost in recurrent soft-tissue sarcoma.

    abstract:PURPOSE:Adjuvant brachytherapy (AB) with immediate (IR) and staged reconstruction (SR) are distinct treatment modalities available for patients with recurrent soft tissue sarcoma (STS). Although SR may offer local control and toxicity benefit, it requires additional upfront procedures, and there is no evidence that it ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2017.65641

    authors: Naghavi AO,Gonzalez RJ,Scott JG,Kim Y,Abuodeh YA,Strom TJ,Echevarria M,Mullinax JE,Ahmed KA,Harrison LB,Fernandez DC

    更新日期:2017-02-01 00:00:00

  • Combined interstitial and surface high-dose-rate brachytherapy treatment of squamous cell carcinoma of the hand.

    abstract:Purpose:We present a case report of treatment using interstitial and surface high-dose-rate (HDR) brachytherapy for cutaneous squamous cell carcinoma (SCC) involving the interspace of the third and fourth digits. The patient refused two-ray amputation and the lesion was not amenable for external beam radiation therapy ...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2020.92408

    authors: Kim DW,Buzurovic IM,Mahal BV,Hwang W,Oladeru OT,O'Farrell DA,Harris TC,Margalit DN,Lam M,Devlin PM

    更新日期:2020-02-01 00:00:00

  • High-dose-rate interstitial brachytherapy for liver metastases: first study from India.

    abstract:PURPOSE:To study the safety and efficacy of high-dose-rate interstitial brachytherapy (HDRIBT) in patients with liver metastases (LM). MATERIAL AND METHODS:Between 2009 and 2011, 10 patients with 12 metastatic lesions in the liver were enrolled in this prospective trial. All patients had either refused surgery or foun...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.36175

    authors: Sharma DN,Thulkar S,Sharma S,Gandhi AK,Haresh KP,Gupta S,Rath GK,Julka PK

    更新日期:2013-06-01 00:00:00

  • Effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors.

    abstract:Purpose:This research aims to evaluate the effectiveness and safety of a robot-assisted 3D personalized template in 125I seed brachytherapy of thoracoabdominal tumors. Material and methods:Forty-three patients with different tumors were involved in this research between 2013 and 2015. They were all eligible to 125I se...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.77957

    authors: Ma X,Yang PZ,Jiang PS,Huo PB,Cao Q,Chai PS,Wang PH

    更新日期:2018-08-01 00:00:00

  • Image-guided brachytherapy (IGBT) combined with whole pelvic intensity-modulated radiotherapy (WP-IMRT) for locally advanced cervical cancer: a prospective study from Chiang Mai University Hospital, Thailand.

    abstract:PURPOSE:A report of preliminary results and toxicity profiles using image-guided brachytherapy (IGBT) combined with whole pelvic intensity-modulated radiation therapy (WP-IMRT) for locally advanced cervical cancer. MATERIAL AND METHODS:Fifteen patients with locally advanced cervical cancer were enrolled into the study...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.34338

    authors: Tharavichitkul E,Wanwilairat S,Chakrabandhu S,Klunklin P,Onchan W,Tippanya D,Nopnop W,Galalae R,Chitapanarux I

    更新日期:2013-03-01 00:00:00

  • Non-melanoma skin cancer treated with high-dose-rate brachytherapy: a review of literature.

    abstract:PURPOSE:The incidence of non-melanoma skin cancer (NMSC) has been increasing over the past 30 years. There are different treatment options and surgical excision is the most frequent treatment due to its low rates of recurrence. Radiotherapy is an effective alternative of surgery, and brachytherapy (BT) might be a bette...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2016.64112

    authors: Delishaj D,Rembielak A,Manfredi B,Ursino S,Pasqualetti F,Laliscia C,Orlandi F,Morganti R,Fabrini MG,Paiar F

    更新日期:2016-12-01 00:00:00

  • Pain relief procedures before high-dose-rate brachytherapy for non-surgical treatment of cervix cancer.

    abstract::Cervical cancer (CC) is a neoplasm with great potential for prevention, but it is still an important public health problem in most developing countries. No significant difference is found in the literature between intracavitary high-dose-rate (HDR) and low-dose-rate (LDR) brachytherapy, when considering overall, disea...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章,评审

    doi:10.5114/jcb.2018.81027

    authors: Pellizzon ACA

    更新日期:2018-12-01 00:00:00

  • Clinical applications of custom-made vaginal cylinders constructed using three-dimensional printing technology.

    abstract:PURPOSE:Three-dimensional (3D) printing technology allows physicians to rapidly create customized devices for patients. We report our initial clinical experience using this technology to create custom applicators for vaginal brachytherapy. MATERIAL AND METHODS:Three brachytherapy patients with unique clinical needs we...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2016.60679

    authors: Sethi R,Cunha A,Mellis K,Siauw T,Diederich C,Pouliot J,Hsu IC

    更新日期:2016-06-01 00:00:00

  • Routine use of ultrasound guided tandem placement in intracavitary brachytherapy for the treatment of cervical cancer - a South Indian institutional experience.

    abstract:PURPOSE:Intracavitary brachytherapy necessitates the insertion of a tandem applicator through the cervical os into the uterine cavity. Blind insertion of the tandem may result in suboptimal tandem placement. This decreases the control of the tumor locally and may result in uterine perforation. Although routine real tim...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.55115

    authors: Rao PB,Ghosh S

    更新日期:2015-10-01 00:00:00

  • Dosimetric comparison of graphical optimization and inverse planning simulated annealing for brachytherapy of cervical cancer.

    abstract:Purpose:Graphical optimization (GO) and inverse planning simulated annealing (IPSA) are the main treatment planning optimization techniques used in patients undergoing 3D brachytherapy treatment. This study aims to compare the dosimetric difference of plans optimized by GO and IPSA in cervical cancer brachytherapy. Ma...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.87145

    authors: Tang B,Liu X,Wang X,Kang S,Wang P,Li J,Orlandini LC

    更新日期:2019-08-01 00:00:00

  • Effect of using different U/S probe Standoff materials in image geometry for interventional procedures: the example of prostate.

    abstract:PURPOSE:This study investigates the distortion of geometry of catheters and anatomy in acquired U/S images, caused by utilizing various stand-off materials for covering a transrectal bi-planar ultrasound probe in HDR and LDR prostate brachytherapy, biopsy and other interventional procedures. Furthermore, an evaluation ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2011.26472

    authors: Diamantopoulos S,Milickovic N,Butt S,Katsilieri Z,Kefala V,Zogal P,Sakas G,Baltas D

    更新日期:2011-12-01 00:00:00

  • Multisector dosimetry in the immediate post-implant period: significant under dosage of the prostate base.

    abstract:PURPOSE:While there are several reports of prostate multisector dosimetry data obtained from CT or MRI scans performed at intervals ranging from 14-70 days after prostate brachytherapy (PB), there are no reports on multisector dosimetry performed in the immediate post-implant period. This study was undertaken to determ...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2014.42023

    authors: Kirschner AN,Sathiaseelan V,Zhang Y,David J,Kalapurakal JA

    更新日期:2014-03-01 00:00:00

  • EGSnrc Monte Carlo-aided dosimetric studies of the new BEBIG (60)Co HDR brachytherapy source.

    abstract:PURPOSE:The purpose of this study is to obtain the dosimetric parameters of the new BEBIG (60)Co brachytherapy source following by TG-43U1 recommendation with appropriate electron cutoff energy (0.521 MeV). MATERIAL AND METHODS:The new BEBIG (60)Co brachytherapy source is used to calculate the TG-43U1 parameters. EGSn...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2013.37419

    authors: Anwarul IM,Akramuzzaman MM,Zakaria GA

    更新日期:2013-09-01 00:00:00

  • Brachytherapy next generation: robotic systems.

    abstract::In a field dominated by external beam radiation therapy (EBRT), both the therapeutic and technical possibilities of brachytherapy (BT) are underrated, shadowed by protons and intensity modulated radiotherapy. Decreasing expertise and indications, as well as increasing lack of specific BT training for radiation therapy...

    journal_title:Journal of contemporary brachytherapy

    pub_type:

    doi:10.5114/jcb.2015.56769

    authors: Popescu T,Kacsó AC,Pisla D,Kacsó G

    更新日期:2015-12-01 00:00:00

  • MRI assisted cervix cancer brachytherapy pre-planning, based on insertion of the applicator in para-cervical anaesthesia: preliminary results of a prospective study.

    abstract:PURPOSE:To report on preliminary results of a prospective study on MRI-assisted cervix cancer brachytherapy pre-planning. MATERIAL AND METHODS:In six locally advanced cervix cancer patients, five days before the first brachytherapy fraction, tandem & ring applicator was inserted under para-cervical anaesthesia, MRI pe...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:

    authors: Petric P,Hudej R,Music M

    更新日期:2009-10-01 00:00:00

  • Carotid dosimetry after re-irradiation with 131Cs permanent implant brachytherapy in recurrent, resected head and neck cancer.

    abstract:Purpose:Permanent seed implant cesium-131 (131Cs) brachytherapy provides highly localized radiation for patients with recurrent head and neck cancer (HNC), who may be ineligible for external beam radiation therapy due to a high-risk of toxicity. As carotid blowout is a concern in the setting of re-irradiation, a dose t...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2019.86298

    authors: Walsh A,Hubley E,Doyle L,Cognetti D,Curry J,Bar-Ad V,Luginbuhl A

    更新日期:2019-06-01 00:00:00

  • Reduction of applicator displacement in MR/CT-guided cervical cancer HDR brachytherapy by the use of patient hover transport system.

    abstract:Purpose:To quantify the reduction of relative displacement between the implanted intracavitary applicator and the patient bony anatomy, due to the use of a hover transport system during the patient transports between the imaging table and the treatment table. Material and methods:The displacement of the applicator ins...

    journal_title:Journal of contemporary brachytherapy

    pub_type: 杂志文章

    doi:10.5114/jcb.2018.73755

    authors: Andrew M,Kim Y,Ginader T,Smith BJ,Sun W,Wang D

    更新日期:2018-02-01 00:00:00