Abstract:
:Background It is uncertain whether a deep learning-based automatic detection algorithm (DLAD) for identifying malignant nodules on chest radiographs will help diagnose lung cancers. Purpose To evaluate the efficacy of using a DLAD in observer performance for the detection of lung cancers on chest radiographs. Materials and Methods Among patients diagnosed with lung cancers between January 2010 and December 2014, 117 patients (median age, 69 years; interquartile range [IQR], 64-74 years; 57 women) were retrospectively identified in whom lung cancers were visible on previous chest radiographs. For the healthy control group, 234 patients (median age, 58 years; IQR, 48-68 years; 123 women) with normal chest radiographs were randomly selected. Nine observers reviewed each chest radiograph, with and without a DLAD. They detected potential lung cancers and determined whether they would recommend chest CT for follow-up. Observer performance was compared with use of the area under the alternative free-response receiver operating characteristic curve (AUC), sensitivity, and rates of chest CT recommendation. Results In total, 105 of the 117 patients had lung cancers that were overlooked on their original radiographs. The average AUC for all observers significantly rose from 0.67 (95% confidence interval [CI]: 0.62, 0.72) without a DLAD to 0.76 (95% CI: 0.71, 0.81) with a DLAD (P < .001). With a DLAD, observers detected more overlooked lung cancers (average sensitivity, 53% [56 of 105 patients] with a DLAD vs 40% [42 of 105 patients] without a DLAD) (P < .001) and recommended chest CT for more patients (62% [66 of 105 patients] with a DLAD vs 47% [49 of 105 patients] without a DLAD) (P < .001). In the healthy control group, no difference existed in the rate of chest CT recommendation (10% [23 of 234 patients] without a DLAD and 8% [20 of 234 patients] with a DLAD) (P = .13). Conclusion Using a deep learning-based automatic detection algorithm may help observers reduce the number of overlooked lung cancers on chest radiographs, without a proportional increase in the number of follow-up chest CT examinations. © RSNA, 2020 Online supplemental material is available for this article.
journal_name
Radiologyjournal_title
Radiologyauthors
Jang S,Song H,Shin YJ,Kim J,Kim J,Lee KW,Lee SS,Lee W,Lee S,Lee KHdoi
10.1148/radiol.2020200165subject
Has Abstractpub_date
2020-09-01 00:00:00pages
652-661issue
3eissn
0033-8419issn
1527-1315journal_volume
296pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract::Solid intrarenal neoplasms in children are usually Wilms tumors. Occasionally, however, a neuroblastoma appears to be intrarenal. In six cases where this phenomenon was observed, the histologic findings of each tumor were identical: undifferentiated neuroblastoma. In each case the child's condition rapidly and progres...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.166.1.2827230
更新日期:1988-01-01 00:00:00
abstract::The American College of Radiology (ACR) convened a "think tank" of experts on aspects of molecular imaging. The purposes of the colloquium were to develop scenarios about how molecular imaging would develop in the future and to make recommendations to the ACR about how to prepare radiologists for this important set of...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2222011530
更新日期:2002-01-01 00:00:00
abstract::History A 43-year-old right-handed man presented with a history of progressive mild left-sided weakness and slowness of movements. Symptoms began 4 years earlier, and the patient noticed a progressive decline in his daily routine due to gait difficulties in the past year. There was no history of head trauma, surgery, ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2017151717
更新日期:2017-05-01 00:00:00
abstract::High-resolution, real-time sonography of the rotator cuff was performed in 51 shoulders, and the results were correlated with findings obtained during subsequent surgery. Prospective sensitivity of sonography in detection of a tear was 100%; specificity, 75%; and accuracy, 92%. Retrospective estimation of tear size on...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.169.3.3055040
更新日期:1988-12-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the long-term results of radiofrequency (RF) ablation combined with chemoembolization (combination therapy) as compared with hepatectomy for the treatment of early-stage hepatocellular carcinoma (HCC). MATERIALS AND METHODS:The study was approved by the institutional review board, a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2471070818
更新日期:2008-04-01 00:00:00
abstract:PURPOSE:To evaluate clinically suspected Morton neuroma with contrast material-enhanced magnetic resonance (MR) images. MATERIALS AND METHODS:Fifteen patients with clinically suspected Morton neuroma underwent examination with conventional T1- and T2-weighted MR imaging and a combination of fat suppression and adminis...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.189.1.8372200
更新日期:1993-10-01 00:00:00
abstract::The specificity of the intraarticular facet block as a diagnostic test for facet joint disease is currently unknown. Capsular rupture with epidural and periarticular diffusion is probably responsible for many false positive findings. We found a comparatively low success rate of the procedure in 25 patients in whom max...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.151.2.6709900
更新日期:1984-05-01 00:00:00
abstract::The chest radiographs of 33 adult hemophiliacs were reviewed for possible pulmonary features of this disease. Only 7 patients showed no abnormalities; 12 patients exhibited scarring, fibrosis, and pleural thickening of the lung, interpreted as the sequelae of intrapulmonary hemorrhage or hemothorax. The remaining 14 p...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/118.1.41
更新日期:1976-01-01 00:00:00
abstract:PURPOSE:To determine the value of ultrasound (US) in the diagnosis of snapping iliopsoas tendon. MATERIALS AND METHODS:In three patients, dynamic US of the hip was performed as the flexed, abducted, and externally rotated hip was extended. The contralateral hip was also evaluated. Hip arthrography was performed in all...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.2.8596860
更新日期:1996-02-01 00:00:00
abstract::Three-compartment arthrography has been advocated in the current literature for evaluation of the intrinsic ligaments of the wrist. Previous techniques for distal radioulnar joint (DRUJ) injection introduce the needle directly into the joint space. As is done in shoulder arthrography, however, the needle tip can be po...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.199.1.8633160
更新日期:1996-04-01 00:00:00
abstract:PURPOSE:To investigate whether cerebral blood volume (CBV), peak height (PH), and percentage of signal intensity recovery (PSR) measurements derived from the results of T2-weighted dynamic susceptibility-weighted contrast material-enhanced (DSC) magnetic resonance (MR) imaging performed after external beam radiation th...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2532090007
更新日期:2009-11-01 00:00:00
abstract::Background Intracranial atherosclerosis is an important cause of ischemic stroke and is associated with several vascular risk factors. Current imaging is mainly based on the assessment of luminal narrowing rather than abnormalities in the vessel wall. Purpose To investigate the relationship between vascular risk facto...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020190643
更新日期:2020-04-01 00:00:00
abstract::Empyema developing from retropharyngeal abscess is a rare complication. Two infants with clinical symptomatology and inital chest radiographic findings of pleural fluid which suggested the possibility of retrophoryngeal abscess are described. A child with submandibular and cervical abscesses is also reported; pleural ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/126.3.743
更新日期:1978-03-01 00:00:00
abstract::The authors reviewed 51 cases of local recurrence after sphincter-saving resection for rectal and rectosigmoid carcinoma to assess the sensitivity of current diagnostic procedures. A combination of follow-up serum CEA levels and rectoscopy was found to be most efficient during the first two years after surgery in term...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.155.2.3983380
更新日期:1985-05-01 00:00:00
abstract:: Online supplemental material is available for this article. ...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2020201724
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:To retrospectively compare the sensitivity of a computer-aided detection (CAD) system for depicting breast cancer in three digital mammographic views. MATERIALS AND METHODS:This study was conducted with institutional review board approval; informed consent was waived. A commercially available CAD system was ap...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2413051145
更新日期:2006-12-01 00:00:00
abstract:PURPOSE:To compare the postdural puncture headache (PDPH) rates after myelography with use of 22-gauge Whitacre (blunt tip) versus standard 22-gauge Quincke (bevel-tip) spinal needles. MATERIALS AND METHODS:At myelography, 340 patients were randomly assigned to one of two groups in which either the Whitacre (167 patie...
journal_title:Radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1148/radiology.200.3.8756930
更新日期:1996-09-01 00:00:00
abstract:PURPOSE:To determine the natural history of intracranial calcifications in infants with treated congenital toxoplasmosis. MATERIALS AND METHODS:Between January 1982 and March 1994, cranial computed tomography was performed in 56 infants with treated congenital toxoplasmosis when they were newborns and approximately 1 ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.199.2.8668790
更新日期:1996-05-01 00:00:00
abstract:PURPOSE:To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS:One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2281020254
更新日期:2003-07-01 00:00:00
abstract::Purpose To evaluate the normal biodistribution and kinetics of (S)-4-(3-[18F]fluoropropyl)-l-glutamic acid ((18)F FSPG) in healthy volunteers and to compare (18)F FSPG mean and maximum standardized uptake values (SUVmean and SUVmax, respectively) with those of (18)F fluorodeoxyglucose (FDG) across a variety of organs....
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015142000
更新日期:2016-06-01 00:00:00
abstract::Medical physics has changed dramatically since 1895. There was a period of slow evolutionary change during the first 70 years after Roentgen's discovery of x rays. With the advent of the computer, however, both diagnostic and therapeutic radiology have undergone rapid growth and changes. Technologic advances such as c...
journal_title:Radiology
pub_type: 历史文章,杂志文章
doi:10.1148/radiology.217.3.r00dc36619
更新日期:2000-12-01 00:00:00
abstract::In real-time ultrasound examinations of six women, jets of urine were noted to enter the bladder during the filling phase. The jets appeared at irregular intervals, and each jet lasted from a fraction of a second up to three seconds. The ureters functioned independently of each other. The flow characteristics of the u...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.140.2.7255730
更新日期:1981-08-01 00:00:00
abstract:PURPOSE:To summarize the overall diagnostic performance of magnetic resonance (MR) angiography in the evaluation of peripheral arteriosclerotic occlusive disease and to identify the most important sources of variation in diagnostic accuracy between studies. MATERIALS AND METHODS:A search strategy in MEDLINE and citati...
journal_title:Radiology
pub_type: 杂志文章,meta分析
doi:10.1148/radiology.217.1.r00oc11105
更新日期:2000-10-01 00:00:00
abstract:PURPOSE:To evaluate the usefulness of T2-weighted fast spin-echo magnetic resonance (MR) imaging with a 512 x 256 matrix for assessment of the preoperative stage of endometrial carcinoma. MATERIALS AND METHODS:Twenty-eight women with histopathologically proved endometrial carcinoma underwent preoperative T2-weighted f...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.206.2.9457210
更新日期:1998-02-01 00:00:00
abstract::Three children with marrow-packing disorders demonstrated exaggerated anterior vertebral notches with poorly defined cortical margins. One child had thalassemia major, another had Gaucher disease, and a third had metastatic neuroblastoma. A discussion of each case and the etiology of the notches is presented. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/131.2.367
更新日期:1979-05-01 00:00:00
abstract:PURPOSE:To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based contrast agent, and in thos...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2015150872
更新日期:2015-09-01 00:00:00
abstract:PURPOSE:To evaluate feasibility and added value of dual-energy computed tomography (CT) in diagnosis of pulmonary embolism (PE). MATERIALS AND METHODS:This institutional animal experimental committee-approved study was performed in accordance with animal care guidelines. Eight New Zealand rabbits underwent standard un...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2521081682
更新日期:2009-07-01 00:00:00
abstract::Liver metastases were discovered in 4 adults during high-dose excretory urography with upper abdominal tomograms. Previous reports in the English literature have noted incidental discovery of hepatic cysts or abscesses during urography, but no documented cases of liver metastases were found. All metastases were visual...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/127.2.373
更新日期:1978-05-01 00:00:00
abstract::A fluoroscopic system was modified to achieve a 95-98% reduction in radiation exposure and dosage to patients compared with other systems that reduce fluoroscopic radiation dosage. This reduction was accomplished by custom selection of a high conversion-factor, triplemode image intensifier; custom design of a variable...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.1.6473790
更新日期:1984-10-01 00:00:00
abstract::The American College of Radiology's Commission on Nuclear Magnetic Resonance has recommended adoption of the term "Magnetic Resonance" as a replacement. The author offers background and rationale for this shift in terminology. ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.150.1.6689780
更新日期:1984-01-01 00:00:00