Virtual Unenhanced Dual-Energy CT Images Obtained with a Multimaterial Decomposition Algorithm: Diagnostic Value for Renal Mass and Urinary Stone Evaluation.

Abstract:

:Background Virtual unenhanced (VUE) images obtained by using a dual-energy CT (DECT) multimaterial decomposition algorithm hold promise for diagnostic use in the abdomen in lieu of true unenhanced (TUE) images. Purpose To assess VUE images obtained from a DECT multimaterial decomposition algorithm in patients undergoing renal mass and urinary stone evaluation. Materials and Methods In this retrospective Health Insurance Portability and Accountability Act-compliant study, DECT was performed in patients undergoing evaluation for renal mass or urinary stone. VUE images were compared quantitatively to TUE images and qualitatively assessed by four independent radiologists. Differences in attenuation between VUE and TUE images were summarized by using 95% limits of agreement. Diagnostic performance in urinary stone detection was summarized by using area under the receiver operating characteristic curve, sensitivity, and specificity. Results A total of 221 patients (mean age ± standard deviation, 61 years ± 14; 129 men) with 273 renal masses were evaluated. Differences in renal mass attenuation between VUE and TUE images were within 3 HU for both enhancing masses (95% limits of agreement, -3.1 HU to 2.7 HU) and nonenhancing cysts (95% limits of agreement, -2.9 HU to 2.5 HU). Renal mass classification as enhancing mass versus nonenhancing cyst did not change (reclassification rate of enhancing masses, 0% [0 of 78]; 95% CI: 0, 5; reclassification rate of nonenhancing cysts, 0% [0 of 193]; 95% CI: 0, 2) with use of VUE in lieu of TUE images. Among 166 urinary stones evaluated, diagnostic performance of VUE images for stone detection was lower compared with that of TUE images (area under the receiver operating characteristic curve, 0.79 [95% CI: 0.73, 0.84] vs 0.93 [95% CI: 0.91, 0.95]; P < .001) due to reduced sensitivity of VUE for detection of stones 3 mm in diameter or less compared with those greater than 3 mm (sensitivity, 23% [25 of 108; 95% CI: 12, 40] vs 88% [126 of 144; 95% CI: 77, 94]; P < .001). Conclusion Compared with true unenhanced images, virtual unenhanced (VUE) images were unlikely to change renal mass classification as enhancing mass versus nonenhancing cyst. Diagnostic performance of VUE images remained suboptimal for urinary stone detection due to subtraction of stones 3 mm or less in diameter. © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Sosna in this issue.

journal_name

Radiology

journal_title

Radiology

authors

Xiao JM,Hippe DS,Zecevic M,Zamora DA,Cai LM,Toia GV,Chandler AG,Dighe MK,O'Malley RB,Shuman WP,Wang CL,Mileto A

doi

10.1148/radiol.2021192448

subject

Has Abstract

pub_date

2021-01-19 00:00:00

pages

192448

eissn

0033-8419

issn

1527-1315

pub_type

杂志文章
  • Leukocyte and 67Ga-citrate dynamics in experimental subcutaneous Streptococcus faecalis infections.

    abstract::The dynamics of white blood cell (WBC) and 67Ga-citrate accumulation were studied in rabbits with subcutaneous polyethylene chambers. Uninfected chamber fluid (CF) contained less than 1,000 WBCs/mm3, most of which were mononuclear. After 67Ga injection, radioactivity increased slowly in uninfected fluid, peaked betwee...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.1.6787660

    authors: Tight RR,Siddiqui AR

    更新日期:1981-07-01 00:00:00

  • Effect of Change in Portal Venous Blood Flow Rates on the Performance of a 2.45-GHz Microwave Ablation Device.

    abstract:PURPOSE:To investigate the effect of change in portal venous blood flow rates on the size and shape of ablations created by a 2.45-GHz microwave ablation device. MATERIALS AND METHODS:This study was exempt from review by the institutional animal care and use committee. An in vitro bovine liver model perfused with auto...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150102

    authors: Dodd GD 3rd,Kreidler SM,Lanctot AC,Glueck DH

    更新日期:2015-12-01 00:00:00

  • Hypoplastic posterior arch of C-1 in children with Down syndrome: a double jeopardy.

    abstract::Radiographs of 38 children with Down syndrome (aged 2-3 years) were retrospectively evaluated for hypoplasia of the posterior arch of the C-1 vertebra. The anteroposterior dimensions of the posterior arch of C-1 were measured and compared with those of an age- and sex-matched control group. The posterior arches of C-2...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.183.1.1532260

    authors: Martich V,Ben-Ami T,Yousefzadeh DK,Roizen NJ

    更新日期:1992-04-01 00:00:00

  • Dose efficiency of screen-film systems used in pediatric radiography.

    abstract::Twenty-one screen-film systems were examined using contrast-detail-dose methods in order to determine which were most dose-efficient for use in pediatric radiography. With a given screen, dose efficiency in the noise-limited region (contrast approximately equal to 0.05) was more or less constant (within the range of e...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.1.6729110

    authors: Cohen G,Wagner LK,McDaniel DL,Robinson LH

    更新日期:1984-07-01 00:00:00

  • Interactive real-time multiplanar CT imaging.

    abstract::A new software program provides the real-time display of high-resolution computed tomographic reformation in the axial, coronal, sagittal, or oblique views. The advantages of this new technique over the standard multiplanar format include (a) larger image display format, (b) reconstruction of entire dataset for each o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.170.1.2909110

    authors: Ney DR,Fishman EK,Magid D,Kuhlman JE

    更新日期:1989-01-01 00:00:00

  • Subjective vs. objective evaluation of gallbladder opacification during oral cholecystography in comparative clinical trials: implications for studies involving visual assessment.

    abstract::Radiographs and CT images taken during oral cholecystography in dogs were interpreted in an independent, blind fashion by three radiologists on two occasions and visual assessment of gallbladder density compared to the actual CT values. While there was significant intra- and inter-observer variation, the mean scores f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.2.7089280

    authors: Fon GT,Hunter TB,Berk RN,Patton DD,Capp MP

    更新日期:1982-07-01 00:00:00

  • The RSNA Pediatric Bone Age Machine Learning Challenge.

    abstract::Purpose The Radiological Society of North America (RSNA) Pediatric Bone Age Machine Learning Challenge was created to show an application of machine learning (ML) and artificial intelligence (AI) in medical imaging, promote collaboration to catalyze AI model creation, and identify innovators in medical imaging. Materi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180736

    authors: Halabi SS,Prevedello LM,Kalpathy-Cramer J,Mamonov AB,Bilbily A,Cicero M,Pan I,Pereira LA,Sousa RT,Abdala N,Kitamura FC,Thodberg HH,Chen L,Shih G,Andriole K,Kohli MD,Erickson BJ,Flanders AE

    更新日期:2019-02-01 00:00:00

  • Spondylodiskitic abscesses: CT-guided percutaneous catheter drainage.

    abstract:PURPOSE:To determine whether computed tomographically (CT) guided percutaneous catheter drainage of spondylodiskitic abscesses is an appropriate and effective alternative to surgery. MATERIALS AND METHODS:CT-guided percutaneous catheter drainage was performed in 21 patients (16 men, five women; age range, 24-81 years)...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.208.2.9680560

    authors: Staatz G,Adam GB,Keulers P,Vorwerk D,Günther RW

    更新日期:1998-08-01 00:00:00

  • Benign hyperplastic nodules that originate in the peripheral zone of the prostate gland.

    abstract:PURPOSE:To describe a benign nodular lesion in the peripheral zone (PZ) of the prostate gland. MATERIALS AND METHODS:In 1,087 patients, the features of 722 focal lesions in the PZ or central zone of the prostate on transrectal ultrasound (TRUS) scans were retrospectively compared with histologic findings in biopsy sam...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.189.3.7694310

    authors: Oyen RH,Van de Voorde WM,Van Poppel HP,Brys PP,Ameye FE,Franssens YM,Baert AL,Baert LV

    更新日期:1993-12-01 00:00:00

  • Normal prostate gland: examination with color Doppler US.

    abstract:PURPOSE:To evaluate the vascular anatomy of the prostate gland with transrectal color Doppler ultrasound (US). MATERIALS AND METHODS:Thirty-five normal prostate glands were studied. Imaging findings were interpreted on the basis of findings from previous anatomic studies. RESULTS:Distribution of flow signals within t...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.196.2.7617860

    authors: Neumaier CE,Martinoli C,Derchi LE,Silvestri E,Rosenberg I

    更新日期:1995-08-01 00:00:00

  • Hemorrhagic fever with renal syndrome: MR imaging of the kidney.

    abstract::Magnetic resonance (MR) imaging of the kidneys was performed in 14 patients with a severe form of hemorrhagic fever with renal syndrome (HFRS), a major public health problem in Far Eastern Asia. To the authors' knowledge, this is the first report of renal assessment with MR imaging in HFRS. Three MR imaging studies we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.175.3.1971450

    authors: Kim SH,Kim S,Lee JS,Choi BI,Kim YG,Han JS,Park JH,Han MC,Kim CW

    更新日期:1990-06-01 00:00:00

  • Holistic component of image perception in mammogram interpretation: gaze-tracking study.

    abstract:PURPOSE:To test the hypothesis that rapid and accurate performance of the proficient observer in mammogram interpretation involves a shift in the mechanism of image perception from a relatively slow search-to-find mode to a relatively fast holistic mode. MATERIALS AND METHODS:This HIPAA-compliant study had institution...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2422051997

    authors: Kundel HL,Nodine CF,Conant EF,Weinstein SP

    更新日期:2007-02-01 00:00:00

  • Ultrasonography in the staging of endometrial adenocarcinoma.

    abstract::Adenocarcinoma of the endometrium commonly presents at an early stage and is readily diagnosed by dilatation and curettage. Ultrasound has not bee accurate in differentiating this malignant neoplasm from benign causes of uterine enlargement such as leiomyoma. In this study, the sonographic findings in 21 patients with...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.140.3.7280250

    authors: Requard CK,Wicks JD,Mettler FA Jr

    更新日期:1981-09-01 00:00:00

  • Tomography of hydrogen with nuclear magnetic resonance.

    abstract::A nuclear magnetic resonance (NMR) imager with a 6.5-cm aperture is described. Spatial resolution is 0.47 X 2.0 mm with a slice thickness of 8.4 mm. Contrast resolution is 3% for a 4-minute image. Because of the excellent spatial resolution and high contrast between soft tissues, the images provide a great deal of det...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.136.3.7403550

    authors: Crooks L,Hoenninger J,Arakawa M,Kaufman L,McRee R,Watts J,Singer JH

    更新日期:1980-09-01 00:00:00

  • Cardiac function: MR evaluation in one breath hold with real-time true fast imaging with steady-state precession.

    abstract::In 12 healthy volunteers and eight patients with cardiac disease, cine magnetic resonance (MR) imaging in the heart was performed with real-time true fast imaging with steady-state precession (FISP), which permitted evaluation of the entire left ventricle in one breath hold (91 msec per frame, 13 frames per section po...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2223011156

    authors: Lee VS,Resnick D,Bundy JM,Simonetti OP,Lee P,Weinreb JC

    更新日期:2002-03-01 00:00:00

  • Arthrography in the diagnosis of ligament injuries and classification of ankle injuries.

    abstract::Arthrography was assessed in 300 cases of ankle injury to determine its diagnostic information yield and its aid in classifying ankle injuries. No complications occurred as a result of the procedure. In 59 cases, information gained from the procedure was verified at surgery. Arthrography was considered to give valuabl...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.1.63

    authors: Ala-Ketola L,Puranen J,Koivisto E,Puuperä M

    更新日期:1977-10-01 00:00:00

  • Multiple sclerosis: improved identification of disease-relevant changes in gray and white matter by using susceptibility-based MR imaging.

    abstract:PURPOSE:To evaluate the potential of quantitative susceptibility (QS) and R2* mapping as surrogate biomarkers of clinically relevant, age-adjusted demyelination and iron deposition in multiple sclerosis (MS). MATERIALS AND METHODS:All study participants gave written informed consent, and the study was approved by the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132475

    authors: Rudko DA,Solovey I,Gati JS,Kremenchutzky M,Menon RS

    更新日期:2014-09-01 00:00:00

  • Acute stroke: evaluation with serial proton MR spectroscopic imaging.

    abstract:PURPOSE:To investigate the evolution of metabolic changes detectable with proton magnetic resonance (MR) spectroscopic imaging in acute stroke and to compare these findings with those of conventional MR imaging. MATERIALS AND METHODS:A patient with middle cerebral artery stroke underwent conventional proton-density (P...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.192.3.8058940

    authors: Barker PB,Gillard JH,van Zijl PC,Soher BJ,Hanley DF,Agildere AM,Oppenheimer SM,Bryan RN

    更新日期:1994-09-01 00:00:00

  • Regional Mapping of Aortic Wall Stress by Using Deformable, Motion-coherent Modeling based on Electrocardiography-gated Multidetector CT Angiography: Feasibility Study.

    abstract::Purpose To investigate the feasibility of deformable, motion-coherent modeling based on electrocardiography-gated multidetector computed tomographic (CT) angiography of the thoracic aorta and to evaluate whether quantifiable information on aortic wall stress as a function of patient-specific cardiovascular parameters ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015151078

    authors: Mileto A,Heye TJ,Makar RA,Hurwitz LM,Marin D,Boll DT

    更新日期:2016-07-01 00:00:00

  • MR imaging of the cochlear modiolus: area measurement in healthy subjects and in patients with a large endolymphatic duct and sac.

    abstract:PURPOSE:To evaluate the cochlear modiolus with thin-section magnetic resonance (MR) imaging in healthy subjects and patients with a large endolymphatic duct and sac, and to assess whether the cochlea is normal or abnormal in patients with a large endolymphatic duct and sac. MATERIALS AND METHODS:MR images were obtaine...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.213.3.r99dc05819

    authors: Naganawa S,Ito T,Iwayama E,Fukatsu H,Ishigaki T,Nakashima T,Ichinose N

    更新日期:1999-12-01 00:00:00

  • Breast calcifications: analysis of imaging properties.

    abstract::The imaging characteristics of microcalcifications in both benign and malignant breast conditions were analyzed in 48 digitized film mammograms. Each case included in this analysis had findings considered suggestive of malignancy by the radiologist, with the underlying histologic structure determined by excisional bio...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.2.3174980

    authors: Olson SL,Fam BW,Winter PF,Scholz FJ,Lee AK,Gordon SE

    更新日期:1988-11-01 00:00:00

  • Generalist versus Subspecialist Characteristics of the U.S. Radiologist Workforce.

    abstract::Purpose To assess subspecialty practice characteristics of the U.S. radiologist workforce. Materials and Methods This study used the Medicare Physician and Other Supplier Public Use File and did not constitute human subject research. The authors identified 33 090 radiologists who billed for professional services betwe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2017171684

    authors: Rosenkrantz AB,Wang W,Hughes DR,Duszak R Jr

    更新日期:2018-03-01 00:00:00

  • Carcinoma of the prostate gland: MR imaging with pelvic phased-array coils versus integrated endorectal--pelvic phased-array coils.

    abstract:PURPOSE:To compare the performance of pelvic phased-array (PPA) coils and integrated endorectal PPA coils in evaluation of local extent of prostate cancer. MATERIALS AND METHODS:Seventy-one men underwent magnetic resonance (MR) imaging within 3 weeks of radical prostatectomy. MR findings of tumor, extracapsular extens...

    journal_title:Radiology

    pub_type: 临床试验,杂志文章

    doi:10.1148/radiology.193.3.7972810

    authors: Hricak H,White S,Vigneron D,Kurhanewicz J,Kosco A,Levin D,Weiss J,Narayan P,Carroll PR

    更新日期:1994-12-01 00:00:00

  • Cryptosporidiosis of the gastric antrum: detection using CT.

    abstract::We describe a patient who had cryptosporidiosis and cytomegalovirus infection of the gastric antrum that was initially detected on computed tomography (CT) scans. CT may be useful in the evaluation of immunocompromised patients with diarrheal illness, as well as in the assessment of the gastrointestinal tract. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3704150

    authors: Soulen MC,Fishman EK,Scatarige JC,Hutchins D,Zerhouni EA

    更新日期:1986-06-01 00:00:00

  • The Effect of Modality and Landmark Selection on MRI and CT Femoral Torsion Angles.

    abstract::Background Assessment of femoral torsion at preoperative hip imaging is commonly recommended. However, it is unclear whether MRI is as accurate as CT and how different methods affect femoral torsion measurements. Purpose To compare MRI- and CT-based assessment of femoral torsion by using four commonly used measurement...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020192723

    authors: Schmaranzer F,Kallini JR,Miller PE,Kim YJ,Bixby SD,Novais EN

    更新日期:2020-08-01 00:00:00

  • Craniosynostosis: correlation of bone scans, radiographs, and surgical findings.

    abstract::Skull scintigraphy was performed in 68 children with suspected craniosynostosis after injection of technetium-99m methylene diphosphonate. The scans demonstrated four patterns of sutural activity: normal, absent, increased, and wide. When correlated with surgical findings, "absent" indicated fused sutures, "increased"...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/133.3.615

    authors: Tait MV,Gilday DL,Ash JM,Boldt DJ,Harwood-Nash DC,Fitz CR,Barry J

    更新日期:1979-12-01 00:00:00

  • Screening for lung cancer in a fixed population by biennial chest radiography.

    abstract::All screening radiographs of the chest and other medical records of 107 patients with histologically proved lung cancer in a fixed population were reviewed to assess the efficacy of biennial chest radiography in detecting lung cancer. Radiographic abnormalities caused by tumors were initially detected in 58 patients (...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.148.2.6306720

    authors: Hayabuchi N,Russell WJ,Murakami J,Nishitani H

    更新日期:1983-08-01 00:00:00

  • Computer tomography: the "resolving" intracerebral hemorrhage.

    abstract::Two patients with a total of 4 intracerebral hemorrhages were examined by serial computer tomography (CT) over a period of up to 6 months, revealing a progressive decrease in lesion volume and density which eventually became less than that of the surrounding brain tissue. These changes were interpreted as complete clo...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/118.3.609

    authors: Messina AV,Chernik NL

    更新日期:1976-03-01 00:00:00

  • Wallerian degeneration demonstrated by magnetic resonance: spectroscopic measurements on peripheral nerve.

    abstract::Wallerian degeneration of rat sciatic nerves was induced by nerve section. Fifteen days later the degenerated nerves were compared with the intact contralateral nerves from the same animal. Histological sections showed the changes typical of wallerian degeneration: axonal degeneration and secondary demyelination. The ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.1.6729140

    authors: Jolesz FA,Polak JF,Ruenzel PW,Adams DF

    更新日期:1984-07-01 00:00:00

  • Acute-phase response after stent implantation in the carotid artery: association with 6-month in-stent restenosis.

    abstract:PURPOSE:To determine the prognostic importance of periintervention serum levels of acute-phase reactants in 6-month restenosis after stent implantation in the carotid artery. MATERIALS AND METHODS:One hundred eight consecutive patients with 70% or greater stenosis of the internal carotid artery (ICA) according to the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2272020183

    authors: Schillinger M,Exner M,Mlekusch W,Rumpold H,Ahmadi R,Sabeti S,Lang W,Wagner O,Minar E

    更新日期:2003-05-01 00:00:00