Adult Hirschprung disease: radiographic findings.

Abstract:

:Hirschprung disease is usually diagnosed in infancy. Occasionally patients reach adulthood without diagnosis or treatment. Four cases of adult Hirschprung disease are described. The principal radiographic findings are a markedly dilated, feces-filled colon above the zone of transition; a narrowed rectum; a cone- or funnel-shaped zone of transition; and a mosaic colonic pattern caused by collapsed redundant mucosa after colonic cleansing. In an adult, identification on a barium enema examination of an abrupt, smooth transition zone in the rectum with proximal colonic dilatation, in conjunction with an appropriate clinical history, should suggest the diagnosis of adult Hirschprung disease.

journal_name

Radiology

journal_title

Radiology

authors

Mindelzun RE,Hicks SM

doi

10.1148/radiology.160.3.3737900

subject

Has Abstract

pub_date

1986-09-01 00:00:00

pages

623-5

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

160

pub_type

杂志文章
  • Duplex carotid sonography: criteria for stenosis, accuracy, and pitfalls.

    abstract::Both carotid bifurcations were examined in 353 patients over a 20-month interval using a combination of real-time and pulsed Doppler ultrasound (duplex scanning). Angiographic correlation was available in 72 cases. Stenosis of the internal carotid was evaluated using a Doppler input frequency of 5 MHz and a scan angle...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.2.3880910

    authors: Jacobs NM,Grant EG,Schellinger D,Byrd MC,Richardson JD,Cohan SL

    更新日期:1985-02-01 00:00:00

  • Tissue relaxation time: in vivo field dependence.

    abstract::Relaxation times (T1 and T2) were measured in vivo in mongrel dogs at fields of 0.3, 0.5, 1.0, 1.35, and 1.5 tesla (T). T1 was measured using nine values of inversion time ranging from 10 to 1,280 msec. T2 was measured with a four-point multiple spin-echo sequence. Relaxation times were calculated for muscle, kidney c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.3.2991980

    authors: Johnson GA,Herfkens RJ,Brown MA

    更新日期:1985-09-01 00:00:00

  • N-Terminal Pro-B-Type Natriuretic Peptide and Subclinical Brain Damage in the General Population.

    abstract::Purpose To investigate the association between N-terminal pro-B-type natriuretic peptide (NT-proBNP), which is a marker of heart disease, and markers of subclinical brain damage on magnetic resonance (MR) images in community-dwelling middle-aged and elderly subjects without dementia and without a clinical diagnosis of...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2016160548

    authors: Zonneveld HI,Ikram MA,Hofman A,Niessen WJ,van der Lugt A,Krestin GP,Franco OH,Vernooij MW

    更新日期:2017-04-01 00:00:00

  • A Deep Learning Model to Predict a Diagnosis of Alzheimer Disease by Using 18F-FDG PET of the Brain.

    abstract::Purpose To develop and validate a deep learning algorithm that predicts the final diagnosis of Alzheimer disease (AD), mild cognitive impairment, or neither at fluorine 18 (18F) fluorodeoxyglucose (FDG) PET of the brain and compare its performance to that of radiologic readers. Materials and Methods Prospective 18F-FD...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018180958

    authors: Ding Y,Sohn JH,Kawczynski MG,Trivedi H,Harnish R,Jenkins NW,Lituiev D,Copeland TP,Aboian MS,Mari Aparici C,Behr SC,Flavell RR,Huang SY,Zalocusky KA,Nardo L,Seo Y,Hawkins RA,Hernandez Pampaloni M,Hadley D,Franc BL

    更新日期:2019-02-01 00:00:00

  • Pulmonary embolus: detection and follow-up using magnetic resonance.

    abstract::Magnetic resonance imaging (MRI) of an angiographically confirmed pulmonary embolus was performed. The thrombus appeared as an intense intraluminal signal within the left descending pulmonary artery; this signal was absent on repeat examination after clot lysis. Because MR will not image flowing blood, it provides a p...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.153.2.6484180

    authors: Moore EH,Gamsu G,Webb WR,Stulbarg MS

    更新日期:1984-11-01 00:00:00

  • Advanced multiple-beam equalization radiography in chest radiology: a simulated nodule detection study.

    abstract::To evaluate the efficacy of AMBER, a multiple-beam equalization system for chest radiography, the authors performed a nodule detection study using an anthropomorphic chest phantom. AMBER and conventional images were compared. The images were read by four observers, and analysis was done by means of modified receiver-o...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.169.1.3420280

    authors: Kool LJ,Busscher DL,Vlasbloem H,Hermans J,vd Merwe PC,Algra PR,Herstel W

    更新日期:1988-10-01 00:00:00

  • Ferromagnetic materials in patients: detection before MR imaging.

    abstract::A number of surgical clips and other metallic materials embedded within patients have ferromagnetic properties that present a potential hazard when in the strong fields associated with magnetic resonance imaging. Several types of magnetometers and metal detectors were investigated as possible pre-imaging screening dev...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.1.4001400

    authors: Finn EJ,Di Chiro G,Brooks RA,Sato S

    更新日期:1985-07-01 00:00:00

  • A comparison of saddle-shaped and solenoidal coils for magnetic resonance imaging.

    abstract::Differences in magnetic resonance (MR) imaging signal-to-noise (S/N) performance between saddle-shaped and solenoidal coils have been postulated. Each coil shape is tied to a particular magnetic field configuration, so that they are not typically interchangeable except in special situations. The solenoidal coil is pre...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.154.1.3964940

    authors: Arakawa M,Crooks LE,McCarten B,Hoenninger JC,Watts JC,Kaufman L

    更新日期:1985-01-01 00:00:00

  • Laser guidance system for CT-guided procedures.

    abstract::In a phantom and in 37 patients, a simple laser guidance system for computed tomography (CT)-guided procedures used the software program of the CT scanner and a laser beam mounted on the CT gantry without need for additional software or components. The skin entry point and angulation of the target path were determined...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.194.1.7997570

    authors: Miaux Y,Guermazi A,Gossot D,Bourrier P,Angoulvant D,Khairoune A,Turki C,Bouché E

    更新日期:1995-01-01 00:00:00

  • Peritoneocele: visualization with defecography and peritoneography performed simultaneously.

    abstract:PURPOSE:To evaluate the use of simultaneous defecography and peritoneography (defecoperitoneography) in patients with an unexplained widening of the rectovaginal space noted at defecography. MATERIALS AND METHODS:Twenty-two patients with unexplained widening of the rectovaginal space noted at defecography were studied...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.202.2.9015060

    authors: Bremmer S,Mellgren A,Holmström B,López A,Udén R

    更新日期:1997-02-01 00:00:00

  • Synthetic ossicular replacements: normal and abnormal CT appearance.

    abstract::Twenty-two patients with synthetic ossicular replacements were studied with computed tomography (CT). Twelve patients had total ossicular replacement prostheses (TORPs), and ten patients had partial ossicular replacement prostheses (PORPs). Good results were achieved in 12 patients (eight with TORPs and four with PORP...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.163.3.3575730

    authors: Swartz JD,Berger AS,Zwillenberg S,Granoff DW,Popky GL

    更新日期:1987-06-01 00:00:00

  • Fibrous ureteral polyps.

    abstract::Twelve cases of fibrous ureteral polyps are presented, illustrating their characteristic radiographic appearances. Two types--a long pedunculated mobile variety having a smooth surface, and a relatively shorter lesion covered with thin, finger-like projections--may be identified. Demonstration of the typical findings ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/130.1.73

    authors: Banner MP,Pollack HM

    更新日期:1979-01-01 00:00:00

  • Nuclear magnetic resonance evaluation of stroke. A preliminary report.

    abstract::Nine patients who had acute and subacute stroke were examined by nuclear magnetic resonance (NMR) using a 6-MHz Bruker Instruments proton scanner. A modified Carr-Purcell-Meiboom-Gill pulse sequence was used for signal detection. The resultant string of spin-echoes was Fourier transformed into projections that were su...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.1.6310680

    authors: Bryan RN,Willcott MR,Schneiders NJ,Ford JJ,Derman HS

    更新日期:1983-10-01 00:00:00

  • Percutaneous cholecystostomy in acute cholecystitis and common duct obstruction.

    abstract::Percutaneous cholecystostomy was performed in 36 patients, of whom 22 patients with acute cholecystitis had decompression of the gallbladder and 14 patients with common duct obstruction had biliary decompression through the gallbladder. In almost all cases of acute cholecystitis, percutaneous cholecystostomy quickly c...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.152.2.6739800

    authors: Pearse DM,Hawkins IF Jr,Shaver R,Vogel S

    更新日期:1984-08-01 00:00:00

  • Chronic obstructive pulmonary disease: thin-section CT measurement of airway wall thickness and lung attenuation.

    abstract:PURPOSE:To prospectively evaluate airway wall thickness and lung attenuation at spirometrically gated thin-section computed tomography (CT) in patients with chronic obstructive pulmonary disease (COPD) and to correlate gated CT findings with pulmonary function test (PFT) results. MATERIALS AND METHODS:The ethical comm...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2342040013

    authors: Orlandi I,Moroni C,Camiciottoli G,Bartolucci M,Pistolesi M,Villari N,Mascalchi M

    更新日期:2005-02-01 00:00:00

  • Azygos arch valves: prevalence and appearance at contrast-enhanced CT.

    abstract:PURPOSE:To evaluate the prevalence and appearance of azygos arch valves at intravenous contrast material-enhanced computed tomography (CT). MATERIALS AND METHODS:Findings of 309 intravenous contrast-enhanced spiral CT examinations of the chest were retrospectively reviewed. The presence of contrast material reflux int...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2301021216

    authors: Yeh BM,Coakley FV,Sanchez HC,Wilson MW,Reddy GP,Gotway MB

    更新日期:2004-01-01 00:00:00

  • Primary advanced and local recurrent head and neck tumors: effective management with interstitial thermal radiation therapy.

    abstract::Thirty-seven patients with 18 primary advanced or persistent, 16 local recurrent, and three local metastatic tumors of the head and neck were treated with a combination of interstitial low-dose iridium-192 radiation therapy and interstitial 915-MHz microwave hyperthermia supplemented by external radiation therapy. Twe...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.176.1.2353100

    authors: Seegenschmiedt MH,Sauer R,Fietkau R,Karlsson UL,Brady LW

    更新日期:1990-07-01 00:00:00

  • New device for percutaneous fragmentation of pulmonary emboli.

    abstract::A new catheter system was designed for percutaneous fragmentation of large pulmonary emboli. The device consists of an impeller rotating at high speed at the center of a self-expandable basket at the tip of a 7-F catheter. The highly flexible catheter was able to reach all tested embolus sites in a glass model of the ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.180.1.2052680

    authors: Schmitz-Rode T,Günther RW

    更新日期:1991-07-01 00:00:00

  • Dentate Nucleus Signal Intensity Increases Following Repeated Gadobenate Dimeglumine Administrations: A Retrospective Analysis.

    abstract::Background Increased cerebral signal intensity (SI) has been reported in patients undergoing MRI with gadolinium-based contrast agents (GBCAs). Published data on gadobenate dimeglumine have been somewhat contradictory. Purpose To evaluate the relationship between dosage of gadobenate dimeglumine and SI change at MRI f...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2020190246

    authors: Nguyen NC,Molnar TT,Cummin LG,Kanal E

    更新日期:2020-07-01 00:00:00

  • Uterine arteriovenous malformations: gray-scale and Doppler US features with MR imaging correlation.

    abstract:PURPOSE:To describe the gray-scale and color and duplex Doppler ultrasound (US) and the magnetic resonance (MR) imaging features of uterine arteriovenous malformations (AVMs). MATERIALS AND METHODS:Uterine AVMs in 10 patients were retrospectively evaluated. All patients underwent gray-scale US and color and duplex Dop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.206.1.9423660

    authors: Huang MW,Muradali D,Thurston WA,Burns PN,Wilson SR

    更新日期:1998-01-01 00:00:00

  • Evaluation of times of maximal involvement for early skin reactions following x irradiation combined with hyperthermic treatment.

    abstract::Times of maximal involvement in mouse skin were determined for reactions produced by graded doses of x irradiation combined with hyperthermic treatment at 37.5, 41, 42, 42.5 and 43 degrees C for one hour. The times of maximal involvement in each case were found to be independent of thermal treatment. These data provid...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/119.2.475

    authors: Leith JT

    更新日期:1976-05-01 00:00:00

  • Neonatal brain: color Doppler imaging. Part I. Technique and vascular anatomy.

    abstract::Color Doppler imaging (CDI) can demonstrate the relative direction and velocity of blood flow in color, superimposed on a conventional gray-scale ultrasound image that depicts stationary tissue. Twenty-five infants were studied with portable CDI in the coronal, sagittal, and axial planes. Bilateral antegrade flow was ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.167.2.3282250

    authors: Mitchell DG,Merton D,Needleman L,Kurtz AB,Goldberg BB,Levy D,Rifkin MD,Pennell RG,Vilaro M,Baltarowich O

    更新日期:1988-05-01 00:00:00

  • Invasive breast cancer: predicting disease recurrence by using high-spatial-resolution signal enhancement ratio imaging.

    abstract:PURPOSE:To retrospectively evaluate high-spatial-resolution signal enhancement ratio (SER) imaging for the prediction of disease recurrence in patients with breast cancer who underwent preoperative magnetic resonance (MR) imaging. MATERIALS AND METHODS:This retrospective study was approved by the institutional review ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2481070846

    authors: Li KL,Partridge SC,Joe BN,Gibbs JE,Lu Y,Esserman LJ,Hylton NM

    更新日期:2008-07-01 00:00:00

  • Ultrasonic visualization of an umbilical vein.

    abstract::A patent umbilical vein was demonstrated via ultrasound in a patient with portal hypertension. Ultrasonographic differential diagnosis of intra- and juxta-hepatic veins is given, with emphasis on real time ultrasonography. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/120.1.159

    authors: Weill F

    更新日期:1976-07-01 00:00:00

  • Hybrid PET/MR imaging of the heart: feasibility and initial results.

    abstract:PURPOSE:To assess the feasibility of hybrid imaging of the heart with fluorine 18 fluorodeoxyglucose (FDG) on an integrated 3-T positron emission tomography (PET)/magnetic resonance (MR) imaging system. MATERIALS AND METHODS:The present study was approved by the local institutional review board. Written informed conse...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13130231

    authors: Nensa F,Poeppel TD,Beiderwellen K,Schelhorn J,Mahabadi AA,Erbel R,Heusch P,Nassenstein K,Bockisch A,Forsting M,Schlosser T

    更新日期:2013-08-01 00:00:00

  • Observer performance in detecting multiple radiographic signals. Prediction and analysis using a generalized ROC approach.

    abstract::The theories of decision processes and signal detection provide a framework for evaluation of observer performance. Some radiological procedures involve a search for multiple similar lesions, e.g., plain radiographic examinations for gallstones or pneumoconiosis. Presuming knowledge of the conventional ROC curve for d...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/121.2.337

    authors: Metz CE,Starr SJ,Lusted LB

    更新日期:1976-11-01 00:00:00

  • Percutaneous Image-guided Laser Photocoagulation of Spinal Osteoid Osteoma: A Single-Institution Series.

    abstract:PURPOSE:To retrospectively evaluate the safety and efficacy of percutaneous image-guided laser photocoagulation for the treatment of spinal osteoid osteoma (OO) in proximity to neural structures. MATERIALS AND METHODS:This study was institutional review board-approved with waivers of informed consent. From January 199...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150491

    authors: Tsoumakidou G,Thénint MA,Garnon J,Buy X,Steib JP,Gangi A

    更新日期:2016-03-01 00:00:00

  • Radiation protection requirements for a whole-body CT scanner.

    abstract::Exposure values for a whole-body CT scanner, obtained from a room protection survey covering one month (119 patients), are reported. It was found that weekly exposures could be expected to be in the range of 350-750 mR/week for a daily load of 12 patients. The h.v.l. of gypsum board, lead, and plate glass at this radi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/122.3.825

    authors: Gross GP,McCullough EC

    更新日期:1977-03-01 00:00:00

  • Fetal anomalies: comparison of MR imaging and US for diagnosis.

    abstract:PURPOSE:To compare prenatal ultrasonography (US) and magnetic resonance (MR) imaging for the diagnosis of fetal anomalies. MATERIALS AND METHODS:Images of 27 fetuses (28 diagnostic cases) with anomalies diagnosed at US were evaluated; in these fetuses, prenatal MR imaging was performed within 15 days of US. Prenatal U...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2322030504

    authors: Frates MC,Kumar AJ,Benson CB,Ward VL,Tempany CM

    更新日期:2004-08-01 00:00:00

  • Symptomatic benign thyroid nodules: efficacy of additional radiofrequency ablation treatment session--prospective randomized study.

    abstract:PURPOSE:To prospectively evaluate the efficacy of additional radiofrequency (RF) ablation by comparing the results of one and two sessions. MATERIALS AND METHODS:All patients gave written informed consent to participate in this institutional review board-approved prospective study. From September 2007 to February 2008...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.12111300

    authors: Huh JY,Baek JH,Choi H,Kim JK,Lee JH

    更新日期:2012-06-01 00:00:00