Ultrasound localization of occult breast lesions.

Abstract:

:High-resolution real-time ultrasound with either a 7.5- or 10-MHz transducer was used to localize 7/9 nonpalpable breast masses previously detected by mammography and to determine where the biopsy needle should be inserted.

journal_name

Radiology

journal_title

Radiology

authors

Laing FC,Jeffrey RB,Minagi H

doi

10.1148/radiology.151.3.6718740

subject

Has Abstract

pub_date

1984-06-01 00:00:00

pages

795-6

issue

3

eissn

0033-8419

issn

1527-1315

journal_volume

151

pub_type

杂志文章
  • Indwelling ureteral stents: percutaneous management of complications.

    abstract::Complications of indwelling ureteral stents were managed percutaneously in 13 patients. These complications consisted of three fractured, three heavily encrusted, and seven migrated stents. While most ureteral stent malfunctions are routinely managed with retrograde techniques, the percutaneous approach allows effecti...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.158.1.3510020

    authors: LeRoy AJ,Williams HJ Jr,Segura JW,Patterson DE,Benson RC Jr

    更新日期:1986-01-01 00:00:00

  • Percutaneous transluminal angioplasty: the treatment of choice for renovascular hypertension due to fibromuscular dysplasia.

    abstract::Twenty-three renal artery stenoses in 21 hypertensive patients, caused by fibromuscular dysplasia, were treated with percutaneous transluminal angioplasty (PTA). Follow-up over a period of 1 to 30 months, including angiography, renal vein renin assay, and radionuclide flow studies, was performed in 8 patients, each wi...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.143.3.6210930

    authors: Tegtmeyer CJ,Elson J,Glass TA,Ayers CR,Chevalier RL,Wellons HA Jr,Studdard WE Jr

    更新日期:1982-06-01 00:00:00

  • Peripheral vascular disease: blinded study of dedicated calf MR angiography versus standard bolus-chase MR angiography and film hard-copy angiography.

    abstract:PURPOSE:To compare the accuracy of contrast material-enhanced three-dimensional (3D) dedicated calf magnetic resonance (MR) angiography with that of bolus-chase MR angiography, with conventional angiography as the reference standard, in patients with symptomatic peripheral vascular disease (PVD). MATERIALS AND METHODS...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2323030244

    authors: Binkert CA,Baker PD,Petersen BD,Szumowski J,Kaufman JA

    更新日期:2004-09-01 00:00:00

  • Prostaglandins and angioplasty. An experimental study in canine arteries.

    abstract::To prevent platelet aggregation following percutaneous transluminal angioplasty (PTA), cyclooxygenase inhibitors such as acetylsalicylic acid (ASA) and indomethacin are recommended. However, ASA blocks both the proaggregating effects of thromboxane (TXA2) and the antiaggregating and vasodilating effects of prostacycli...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.149.3.6227930

    authors: Zollikofer CL,Cragg AH,Einzig S,Castaneda-Zuniga WR,Castaneda F,Rysavy JA,Bruhlmann WF,Shebuski RJ,Amplatz K

    更新日期:1983-12-01 00:00:00

  • Effect of smoking on restenosis during the 1st year after lower-limb endovascular interventions.

    abstract:PURPOSE:To investigate whether smoking has an effect on recurrent lumen narrowing after percutaneous transluminal angioplasty (PTA) or stent placement in lower-limb arteries. MATERIALS AND METHODS:A total of 650 patients (median age, 70 years; 389 men) with peripheral artery disease who underwent iliac artery PTA (n =...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2313031088

    authors: Schillinger M,Exner M,Mlekusch W,Haumer M,Sabeti S,Ahmadi R,Wagner O,Minar E

    更新日期:2004-06-01 00:00:00

  • Calcifications in breast biopsy specimens: discrepancies in radiologic-pathologic identification.

    abstract::To analyze the effectiveness and accuracy of the diagnostic process from screening mammography to final diagnosis at pathologic examination, the authors conducted a prospective study of 277 consecutive patients who underwent 291 mammographically directed biopsies of nonpalpable lesions. Of the 170 lesions that demonst...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.179.1.2006260

    authors: Stein MA,Karlan MS

    更新日期:1991-04-01 00:00:00

  • High Signal Intensity in Globus Pallidus and Dentate Nucleus on Unenhanced T1-weighted MR Images: Evaluation of Two Linear Gadolinium-based Contrast Agents.

    abstract:PURPOSE:To determine if a correlation exists between the number of previous enhanced magnetic resonance (MR) imaging examinations and high signal intensity in the globus pallidus (GP) and dentate nucleus (DN) in patients who received gadodiamide (Omniscan), a linear nonionic gadolinium-based contrast agent, and in thos...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015150872

    authors: Ramalho J,Castillo M,AlObaidy M,Nunes RH,Ramalho M,Dale BM,Semelka RC

    更新日期:2015-09-01 00:00:00

  • MR-guided percutaneous intramyocardial injection with an MR-compatible catheter: feasibility and changes in T1 values after injection of extracellular contrast medium in pigs.

    abstract:PURPOSE:To assess the feasibility of percutaneous magnetic resonance (MR)-guided intramyocardial injection of gadodiamide by using real-time imaging and to quantify T1 values and the size of the enhanced region for different concentrations of contrast agent for 30 minutes after injection. MATERIALS AND METHODS:Animal ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2352031760

    authors: Krombach GA,Pfeffer JG,Kinzel S,Katoh M,Günther RW,Buecker A

    更新日期:2005-05-01 00:00:00

  • Regional Mapping of Aortic Wall Stress by Using Deformable, Motion-coherent Modeling based on Electrocardiography-gated Multidetector CT Angiography: Feasibility Study.

    abstract::Purpose To investigate the feasibility of deformable, motion-coherent modeling based on electrocardiography-gated multidetector computed tomographic (CT) angiography of the thoracic aorta and to evaluate whether quantifiable information on aortic wall stress as a function of patient-specific cardiovascular parameters ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2015151078

    authors: Mileto A,Heye TJ,Makar RA,Hurwitz LM,Marin D,Boll DT

    更新日期:2016-07-01 00:00:00

  • Inflammatory polyp of the renal pelvis simulating transitional cell carcinoma.

    abstract::An inflammatory polyps of the renal pelvis that caused a mass effect at excretory urography simulated transitional cell carcinoma. In the differential diagnoses of intracalyceal masses, therefore, inflammatory polyp must be considered. ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.144.3.7100460

    authors: Reuter KL,Krolikowski FJ,D'Orsi CJ,Yu D,Raptopoulos VD

    更新日期:1982-08-01 00:00:00

  • MR imaging in pelvic inflammatory disease: comparison with laparoscopy and US.

    abstract:PURPOSE:To assess the value of magnetic resonance (MR) imaging in the diagnosis of pelvic inflammatory disease (PID) and to compare MR imaging with transvaginal ultrasonography (US) and laparoscopy. MATERIALS AND METHODS:Thirty consecutive patients hospitalized because they were clinically suspected of having PID unde...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.210.1.r99ja04209

    authors: Tukeva TA,Aronen HJ,Karjalainen PT,Molander P,Paavonen T,Paavonen J

    更新日期:1999-01-01 00:00:00

  • Endovascular Interventions for Acute and Chronic Lower Extremity Deep Venous Disease: State of the Art.

    abstract::The societal and individual burden caused by acute and chronic lower extremity venous disease is considerable. In the past several decades, minimally invasive endovascular interventions have been developed to reduce thrombus burden in the setting of acute deep venous thrombosis to prevent both short- and long-term mor...

    journal_title:Radiology

    pub_type: 杂志文章,评审

    doi:10.1148/radiol.2015132603

    authors: Sista AK,Vedantham S,Kaufman JA,Madoff DC

    更新日期:2015-07-01 00:00:00

  • Intracranial lesions: flow-related enhancement on MR images using time-of-flight effects.

    abstract::Many physico-anatomic variables and instrument parameters influence the relative magnetic resonance signal intensity of vascular channels. The interaction of these mechanisms is complex, but their composite effects can be accounted for by two main categories of flow phenomena: time-of-flight effects and spin-phase cha...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.161.3.3786730

    authors: Kucharczyk W,Kelly WM,Davis DO,Norman D,Newton TH

    更新日期:1986-12-01 00:00:00

  • Rectal biopsy as a cause of rectal ulceration.

    abstract::We report three patients in whom the performance of a rectal biopsy produced an ulcer that was found during a subsequent examination (two at double-contrast barium enema examinations and one at colonoscopy). In each case, the iatrogenic ulcers presented an unusual appearance and resulted in the performance of inapprop...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.156.1.4001420

    authors: Millward SF,Chapman A,Somers S,Stevenson GW

    更新日期:1985-07-01 00:00:00

  • Single-session treatment of benign cystic thyroid nodules with ethanol versus radiofrequency ablation: a prospective randomized study.

    abstract:PURPOSE:To compare volume reduction of single-session ethanol ablation (EA) and radiofrequency (RF) ablation for cystic thyroid nodule treatment. MATERIALS AND METHODS:All patients gave written informed consent to participate in this prospective institutional review board-approved study. From May 6, 2010, to August 8,...

    journal_title:Radiology

    pub_type: 杂志文章,随机对照试验

    doi:10.1148/radiol.13122134

    authors: Sung JY,Baek JH,Kim KS,Lee D,Yoo H,Kim JK,Park SH

    更新日期:2013-10-01 00:00:00

  • Polytomoencephalography of the optic chiasm and adjacent structures.

    abstract::The addition of polytomography considerably increases the sensitivity of pneumoencephalography. The chiasmatic area lends itself particularly well to investigation by polytomoencephalography. In a series of 28 patients, the transverse dimension of the optic chiasm ranged from 4 to 20 mm, with a mean of 18 mm. The post...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/114.3.629

    authors: Johnson JC,Lubow M,Stears J

    更新日期:1975-03-01 00:00:00

  • The reliability of echocardiography in the diagnosis of infective endocarditis.

    abstract::The echocardiograms of 17 patients with proved infective endocarditis were surveyed to assess the reliability of echocardiography in this disease. Vegetations were present on 20 valves (11 aortic, 7 mitral, 2 tricuspid) at surgery or autopsy. Echocardiography correctly identified the abnormality in 11 valves. There we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/125.2.473

    authors: Thomson KR,Nanda NC,Gramiak R

    更新日期:1977-11-01 00:00:00

  • Prognostic value of grading masticator space involvement in nasopharyngeal carcinoma according to MR imaging findings.

    abstract:PURPOSE:To derive a suitable method for grading masticator space invasion in nasopharyngeal carcinoma on the basis of magnetic resonance (MR) images and to determine its prognostic value in patients undergoing intensity-modulated radiation therapy. MATERIALS AND METHODS:After institutional review board approval and in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.14132745

    authors: Zhang GY,Huang Y,Cai XY,Chen XP,Xu T,Wu J,Wei WH,Liu LZ,Huang ZL,Zhou MM,Xia ST,Wang YJ

    更新日期:2014-10-01 00:00:00

  • Preparation of 52Fe and its use in a 52Fe/52mMn generator.

    abstract::Clinically useful quantities of 52Fe have been prepared at the Brookhaven Linac Isotope Producer (BLIP) by bombarding manganese or nickel targets with medium energy protons. After chemical separation, 52Fe is loaded onto a generator column from which carrier-free 52Mn is eluted. The 52mMn generator is potentially usef...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/132.2.475

    authors: Ku TH,Richards P,Stang LG Jr,Prach T

    更新日期:1979-08-01 00:00:00

  • Left coronary arterial blood flow: noninvasive detection by Doppler US.

    abstract::Continuous wave (CW) and pulsed Doppler ultrasound studies with spectral analysis were used to detect the left coronary arterial blood flow in patients who were undergoing routine echocardiography. The pulmonary artery is a stable ultrasonic landmark from which detection of the blood flow can be effected. The left cor...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.159.3.3517950

    authors: Gramiak R,Holen J,Moss AJ,Gutierrez OH,Picone AL,Roe SA

    更新日期:1986-06-01 00:00:00

  • Determining Malignant Potential of Intraductal Papillary Mucinous Neoplasm of the Pancreas: CT versus MRI by Using Revised 2017 International Consensus Guidelines.

    abstract::Background Several changes have been made to the revised 2017 international consensus guidelines for management of pancreatic intraductal papillary mucinous neoplasms (IPMNs). However, the diagnostic performance is yet to be verified. Purpose To evaluate the revised guidelines for predicting malignant potential of pan...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2019190144

    authors: Lee JE,Choi SY,Min JH,Yi BH,Lee MH,Kim SS,Hwang JA,Kim JH

    更新日期:2019-10-01 00:00:00

  • US Molecular Imaging of Acute Ileitis: Anti-Inflammatory Treatment Response Monitored with Targeted Microbubbles in a Preclinical Model.

    abstract::Purpose To evaluate whether dual-selectin-targeted US molecular imaging allows longitudinal monitoring of anti-inflammatory treatment effects in an acute terminal ileitis model in swine. Materials and Methods The Institutional Animal Care and Use Committee approved all animal studies. Fourteen swine with chemically in...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018172600

    authors: Wang H,Hyvelin JM,Felt SA,Guracar I,Vilches-Moure JG,Cherkaoui S,Bettinger T,Tian L,Lutz AM,Willmann JK

    更新日期:2018-10-01 00:00:00

  • Brain scanning in unilateral and bilateral occlusion of the posterior cerebral arteries.

    abstract::Nineteen patients with unequivocal angiographic evidence of unilateral or bilateral posterior cerebral artery occulsion were scanned during the acute phase of the stroke. In 12 of them an abnormal accumulation of radioactivity was apparent on the posterior view, but only 2 also exhibited abnormal uptake on the corresp...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/123.2.393

    authors: Elinsiedel-Lechtape H,Lechtape-Grüter R

    更新日期:1977-05-01 00:00:00

  • Display of CT studies on a two-screen electronic workstation versus a film panel alternator: sensitivity and efficiency among radiologists.

    abstract::Prototype electronic workstations incorporated in networks linking computed tomographic (CT) and magnetic resonance imaging systems are being developed. The authors compared observer efficiency and sensitivity in reading body CT studies from a two-screen workstation (1,000-line monitors and 12-bit dynamic range in ima...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.174.3.2305060

    authors: Foley WD,Jacobson DR,Taylor AJ,Goodman LR,Stewart ET,Gurney JW,Stroka D

    更新日期:1990-03-01 00:00:00

  • Radiation-induced decrease in nitric oxide synthase--containing nerves in the rat penis.

    abstract:PURPOSE:Evaluate effect of prostatic irradiation on erectile function. MATERIALS AND METHODS:Forty-seven male adult rats were divided into three groups according to a single radiation dose to the prostate: control (no irradiation) (n = 15), 1,000 cGy (n = 15), and 2,000 cGy (n = 17). Five months after irradiation, rat...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.195.1.7534430

    authors: Carrier S,Hricak H,Lee SS,Baba K,Morgan DM,Nunes L,Ross GY,Phillips TL,Lue TF

    更新日期:1995-04-01 00:00:00

  • Whole-brain analysis of amyotrophic lateral sclerosis by using echo-planar spectroscopic imaging.

    abstract:PURPOSE:To detect regional metabolic differences in amyotrophic lateral sclerosis (ALS) with whole-brain echo-planar spectroscopic imaging. MATERIALS AND METHODS:Sixteen patients with ALS (nine men, seven women; mean age, 56.6 years), five persons suspected of having ALS (four men, one woman; mean age, 62.6 years), an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.13121148

    authors: Verma G,Woo JH,Chawla S,Wang S,Sheriff S,Elman LB,McCluskey LF,Grossman M,Melhem ER,Maudsley AA,Poptani H

    更新日期:2013-06-01 00:00:00

  • Normal modiolus: CT appearance in patients with a large vestibular aqueduct.

    abstract:PURPOSE:To determine the computed tomographic (CT) appearance of the normal modiolus and the pathologic alteration in patients with a large vestibular aqueduct and an otherwise normal-appearing cochlea. MATERIALS AND METHODS:Temporal bone CT studies obtained before and after a major upgrade of CT capability in 1992 we...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.204.1.9205250

    authors: Lemmerling MM,Mancuso AA,Antonelli PJ,Kubilis PS

    更新日期:1997-07-01 00:00:00

  • Mapping Hypoxia in Renal Carcinoma with Oxygen-enhanced MRI: Comparison with Intrinsic Susceptibility MRI and Pathology.

    abstract::Purpose To cross-validate T1-weighted oxygen-enhanced (OE) MRI measurements of tumor hypoxia with intrinsic susceptibility MRI measurements and to demonstrate the feasibility of translation of the technique for patients. Materials and Methods Preclinical studies in nine 786-0-R renal cell carcinoma (RCC) xenografts an...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2018171531

    authors: Little RA,Jamin Y,Boult JKR,Naish JH,Watson Y,Cheung S,Holliday KF,Lu H,McHugh DJ,Irlam J,West CML,Betts GN,Ashton G,Reynolds AR,Maddineni S,Clarke NW,Parker GJM,Waterton JC,Robinson SP,O'Connor JPB

    更新日期:2018-09-01 00:00:00

  • MR hydrometry to assess exocrine function of the pancreas: initial results of noninvasive quantification of secretion.

    abstract:PURPOSE:To evaluate magnetic resonance (MR) hydrometry, a method of quantifying fluid amounts by using MR imaging, for assessing the exocrine function of the pancreas after stimulation with secretin. MATERIALS AND METHODS:Images were obtained with a single-shot turbo spin-echo sequence by using a 1.0-T magnet with a q...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiology.218.1.r01ja2061

    authors: Heverhagen JT,Müller D,Battmann A,Ishaque N,Boehm D,Katschinski M,Wagner HJ,Klose KJ

    更新日期:2001-01-01 00:00:00

  • Imaging performance with different doses in skeletal radiography: comparison of a needle-structured and a conventional storage phosphor system with a flat-panel detector.

    abstract:PURPOSE:To evaluate possible radiation dose reduction in the extremities with use of digital radiography and a needle-structured image plate (NIP) by comparing this technique with digital radiography performed with a powder-structured image plate (PIP) and a flat-panel detector (FPD). MATERIALS AND METHODS:This study ...

    journal_title:Radiology

    pub_type: 杂志文章

    doi:10.1148/radiol.2493080640

    authors: Wirth S,Treitl M,Reiser MF,Körner M

    更新日期:2009-01-01 00:00:00