Abstract:
PURPOSE:To analyze the effect of the 1991 Maryland legislative mandate of screening mammography benefits. MATERIALS AND METHODS:Claims submitted between January 1991 and December 1993 for outpatient mammograms obtained in women covered under Blue Cross Blue Shield of Maryland insurance indemnity contracts were analyzed for the distribution of services and charges. RESULTS:For 184,723 women, 285,241 claims were submitted by 851 Maryland providers. Claims for "mammography bilateral," which were considered "diagnostic," represented 67%; 24% were submitted for "screening mammography bilateral," and 9% were submitted for "mammography unilateral." Mammography claims increased only 25% during the 3 years, despite an estimated fivefold increase in the number of women with the screening mammography benefit. Mammography coding shifted from bilateral to screening. CONCLUSION:The number of mammograms obtained increased only modestly after the mandate, but claims coded for mammography bilateral declined dramatically. Removal of financial barriers appears to be insufficient to increase appropriate use of screening mammography.
journal_name
Radiologyjournal_title
Radiologyauthors
Dans PE,Wright ATdoi
10.1148/radiology.198.3.8628850subject
Has Abstractpub_date
1996-03-01 00:00:00pages
657-60issue
3eissn
0033-8419issn
1527-1315journal_volume
198pub_type
杂志文章相关文献
RADIOLOGY文献大全abstract:PURPOSE:To determine whether computed tomographic (CT) findings can help differentiate between benign and clinically worrisome causes of pneumatosis intestinalis (PI) in children. MATERIALS AND METHODS:This retrospective study was approved by the institutional review board, and requirement for informed consent was wai...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2532090168
更新日期:2009-11-01 00:00:00
abstract::Diffusion magnetic resonance (MR) imaging is evolving into a potent tool in the examination of the central nervous system. Although it is often used for the detection of acute ischemia, evaluation of directionality in a diffusion measurement can be useful in white matter, which demonstrates strong diffusion anisotropy...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.2452060445
更新日期:2007-11-01 00:00:00
abstract::Background CT deep learning reconstruction (DLR) algorithms have been developed to remove image noise. How the DLR affects image quality and radiation dose reduction has yet to be fully investigated. Purpose To investigate a DLR algorithm's dose reduction and image quality improvement for pediatric CT. Materials and M...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2020202317
更新日期:2021-01-01 00:00:00
abstract::Using a method combining the velocity of ultrasound and photon absorptiometry in the human radius in vivo, the authors measured the speed of sound in bone (U) and bone mineral content (BMC). From these measurements and a "simple" bone model, they then computed the bone mineral density, compact bone density, and modulu...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.138.3.7465850
更新日期:1981-03-01 00:00:00
abstract::In 24 CT studies in children with brain stem gliomas, the CT appearance was seen to vary with the tumor's physical characteristics. Infiltrative tumors produce diffuse enlargement of the brain stem; they are isodense with brain parenchyma or of decreased density and may show partial enhancement. Some gliomas grow foca...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.134.1.7350640
更新日期:1980-01-01 00:00:00
abstract:PURPOSE:To investigate the potential application of contrast material-enhanced three-dimensional (3D) ultrasonography (US), as compared with contrast-enhanced 3D computed tomography (CT), for characterization of focal liver tumors. MATERIALS AND METHODS:Institutional review board approval and informed patient consent ...
journal_title:Radiology
pub_type: 杂志文章,随机对照试验
doi:10.1148/radiol.2511081324
更新日期:2009-04-01 00:00:00
abstract::Multisection, dual-echo magnetic resonance (MR) transaxial images of blood vessels contain both anatomic and qualitative information about flow. Even so, the images are produced as a series of two-dimensional tomographic sections from which full visualization of connected structures is difficult. A computer algorithm ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.157.3.4059560
更新日期:1985-12-01 00:00:00
abstract::The authors investigated the contrast enhancement characteristics of the coronary artery stent lumen to assess patency and then evaluated the accuracy of computed tomographic (CT) measurement of the in-stent luminal diameter. Nineteen patients (16 men and three women; mean age, 58.7 years) with 26 stents underwent car...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2331031564
更新日期:2004-10-01 00:00:00
abstract:PURPOSE:To evaluate the frequency of the supraacetabular fossa (SAF) (pseudodefect of acetabular cartilage) at magnetic resonance (MR) arthrography of the hip and to compare the MR findings with those from arthroscopy. MATERIALS AND METHODS:All patients gave written permission for anonymized use of their medical data ...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.12111397
更新日期:2012-05-01 00:00:00
abstract:PURPOSE:To determine the speed of and changes in the speed of coronary arterial movement during the cardiac cycle with electron-beam computed tomography (CT). MATERIALS AND METHODS:With electron-beam CT, 20 consecutive cross-sectional images were acquired at the mid right coronary artery (with 50-msec acquisition time...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.216.2.r00au19457
更新日期:2000-08-01 00:00:00
abstract:PURPOSE:To define the beneficial and detrimental effects of adding exercise to direct magnetic resonance (MR) shoulder arthrography. MATERIALS AND METHODS:Direct, intraarticular, gadolinium arthrography of the shoulder was performed in 41 patients, who underwent 1.5-T MR imaging before and after 1 minute of arm swingi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.215.2.r00ma14491
更新日期:2000-05-01 00:00:00
abstract::History A 52-year-old man with a history of urinary tract infections and a previous clinical diagnosis of left inguinal hernia presented to the nephrologist with recent onset of dysuria and increasing swelling in the left inguinoscrotal region in the absence of fever or scrotal trauma. There was no relevant surgical o...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.16141805
更新日期:2016-06-01 00:00:00
abstract::Magnetic resonance imaging (MRI) of an angiographically confirmed pulmonary embolus was performed. The thrombus appeared as an intense intraluminal signal within the left descending pulmonary artery; this signal was absent on repeat examination after clot lysis. Because MR will not image flowing blood, it provides a p...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.153.2.6484180
更新日期:1984-11-01 00:00:00
abstract::Computed tomograms, angiograms, and operative findings in 18 intra-atrial and 6 para-atrial lateral ventricle tumors were reviewed. Intra-atrial tumors were characteristically homogeneous, with an intraluminal mass effect. The benign types engulfed the choroid glomus; on angiography, the choroidal arteries were enlarg...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.145.1.7122900
更新日期:1982-10-01 00:00:00
abstract:PURPOSE:To compare specific findings at T1-weighted gradient-echo (GRE) magnetic resonance (MR) imaging performed after administration of superparamagnetic iron oxide (SPIO) with nontumorous regional portal perfusion abnormalities seen at computed tomography (CT) during arterial portography (CTAP). MATERIALS AND METHO...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.207.1.9530300
更新日期:1998-04-01 00:00:00
abstract:PURPOSE:To prospectively assess the potential of noninvasive diffusion-weighted magnetic resonance (MR) imaging to depict changes in microperfusion and diffusion in patients with acute unilateral ureteral obstruction. MATERIALS AND METHODS:The local ethics committee approved the study protocol. Informed consent was ob...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2523082090
更新日期:2009-09-01 00:00:00
abstract:PURPOSE:To investigate the histopathologic and dynamic magnetic resonance (MR) imaging correlates of intrinsic susceptibility-weighted (ISW) MR imaging in patients with primary human breast adenocarcinoma and to assess the relationship between baseline transverse relaxation rate (R2*) and T2* relaxivity change (ΔR2*) a...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.10100421
更新日期:2010-12-01 00:00:00
abstract::In the early years of nuclear medicine, physicians explored applied nuclear physics, and physicists pursued uncharted areas in medicine. Reflections from Jim Adelstein, MD, PhD, John McAfee, MD, Henry Wagner, MD, Fred Bonte, MD, Dave Kuhl, MD, and Alex Gottschalk, MD, add to the appreciation of the diversity in those ...
journal_title:Radiology
pub_type: 历史文章,杂志文章
doi:10.1148/radiology.214.3.r00mr33623
更新日期:2000-03-01 00:00:00
abstract:PURPOSE:To derive a suitable method for grading masticator space invasion in nasopharyngeal carcinoma on the basis of magnetic resonance (MR) images and to determine its prognostic value in patients undergoing intensity-modulated radiation therapy. MATERIALS AND METHODS:After institutional review board approval and in...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.14132745
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:To determine the dose characteristics of multi-detector row computed tomography (CT) and to provide tabulated dose values and rules of thumb that assist in minimizing the radiation dose at multi-detector row CT. MATERIALS AND METHODS:Weighted CT dose index (CTDI100w) values were obtained from three multi-detec...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2263020205
更新日期:2003-03-01 00:00:00
abstract::A new renal imaging agent, technetium-99m mercaptoacetyltriglycine (MAG3, mertiatide), is currently undergoing clinical trials. Like iodine-131 orthoiodohippurate (OIH)--and unlike all other available agents--it is avidly secreted by the renal tubules. Fifty patients underwent simultaneous renal imaging studies with I...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.172.2.2526350
更新日期:1989-08-01 00:00:00
abstract:PURPOSE:To evaluate the accuracy of transvaginal ultrasound (US) and gadolinium-enhanced magnetic resonance (MR) imaging in the assessment of the intratumoral structure of an adnexal mass. MATERIALS AND METHODS:The population comprised 82 patients with an adnexal mass who underwent both transvaginal US and gadolinium-...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.198.1.8539360
更新日期:1996-01-01 00:00:00
abstract:PURPOSE:To quantify the effects of spiral computed tomographic (CT) acquisition parameters on the magnitude of three-dimensional (3D) rippling artifacts and polyp depiction. MATERIALS AND METHODS:An in vitro colon phantom was constructed with air-filled acrylic cylinders that contained synthetic polyps of 3-13 mm. The...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.217.1.r00oc13165
更新日期:2000-10-01 00:00:00
abstract:PURPOSE:To investigate the association between cumulative operator volume and the risk of hepatocellular carcinoma (HCC) recurrence after potentially curative radiofrequency ablation (RFA). MATERIALS AND METHODS:This study was approved by the Research Ethics Committee. By using the Taiwan National Health Insurance Res...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.15141864
更新日期:2015-07-01 00:00:00
abstract::From a clinical-radiologic standpoint, there are a limited number of structures and disease entities in the temporal bone with which one must be familiar in order to proficiently interpret a computed tomographic or magnetic resonance imaging study of the temporal bone. It is helpful to examine the region in an organiz...
journal_title:Radiology
pub_type: 杂志文章,评审
doi:10.1148/radiol.13120733
更新日期:2013-10-01 00:00:00
abstract:PURPOSE:To retrospectively evaluate the accuracy of magnetic resonance (MR) imaging in depicting posterior cul-de-sac obliteration in patients with endometriosis. MATERIALS AND METHODS:Institutional review board approval was not required for this retrospective study, but informed consent was obtained from all patients...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.2343031366
更新日期:2005-03-01 00:00:00
abstract:PURPOSE:To determine if patients with multiple fluid collections need every collection aspirated and if cross-contamination is a risk if separate sterile procedures are not followed for each aspiration. MATERIALS AND METHODS:Records from 1,076 imaging-guided percutaneous aspirations and drainages over 39 months were r...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.212.3.r99se25669
更新日期:1999-09-01 00:00:00
abstract:PURPOSE:To describe the diaphragm muscle slip sign, a previously unreported finding of pneumoperitoneum on plain radiographs. MATERIALS AND METHODS:Diaphragmatic muscle slips were observed on supine plain abdominal (n = 6) or recumbent frontal chest (n = 3) radiographs in nine patients. Computed tomographic (CT) confi...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiology.203.2.9114100
更新日期:1997-05-01 00:00:00
abstract:PURPOSE:To analyze the contribution of the transverse relaxation parameter (T2), macroscopic field inhomogeneities (B0), and blood volume fraction (BVf) to blood oxygen level-dependent (BOLD)-based magnetic resonance (MR) measurements of blood oxygen saturation (SO2) obtained in a brain tumor model. MATERIALS AND METH...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.11110518
更新日期:2012-02-01 00:00:00
abstract:PURPOSE:To compare diagnostic performance and time efficiency of double-reading first-reader computer-aided detection (CAD) (DR FR CAD) followed by radiologist interpretation with that of an unassisted read using segmentally unblinded colonoscopy as reference standard. MATERIALS AND METHODS:The local ethical committee...
journal_title:Radiology
pub_type: 杂志文章
doi:10.1148/radiol.13121192
更新日期:2013-09-01 00:00:00