New method for contrast manipulation in DNP-enhanced MRI.

Abstract:

:The magnetization subtraction technique (MS), which is equivalent to the inversion recovery technique in strong magnetic fields, has been implemented in dynamic nuclear polarization-enhanced magnetic resonance imaging (DNPI). The general theoretical basis of the MS method, which can be applied to DNPI or to prepolarized MRI in weak magnetic fields (such as Earth's magnetic field), is introduced. Details are provided about the signal amplitude, dynamic range of the method, and conditions required to observe signal void in samples with specific T1 relaxation times. The experimental results obtained with MS DNPI are presented and discussed. In the experiments, electron spin resonance irradiation frequencies of 199 MHz and 16.2 MHz were employed. Also, T1 contrast manipulation in the polarizing and in the detection magnetic field is discussed and demonstrated for MS DNPI.

journal_name

Magn Reson Med

authors

Planinsic G,Grucker D,Stepisnik J

doi

10.1002/mrm.1910350316

subject

Has Abstract

pub_date

1996-03-01 00:00:00

pages

379-83

issue

3

eissn

0740-3194

issn

1522-2594

journal_volume

35

pub_type

杂志文章
  • Comparison of model-based arterial input functions for dynamic contrast-enhanced MRI in tumor bearing rats.

    abstract::When using tracer kinetic modeling to analyze dynamic contrast-enhanced MRI (DCE-MRI) it is necessary to identify an appropriate arterial input function (AIF). The measured AIF is often poorly sampled in both clinical and preclinical MR systems due to the initial rapid increase in contrast agent concentration and the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21959

    authors: McGrath DM,Bradley DP,Tessier JL,Lacey T,Taylor CJ,Parker GJ

    更新日期:2009-05-01 00:00:00

  • Reduction of B1 sensitivity in selective single-slab 3D turbo spin echo imaging with very long echo trains.

    abstract::Single-slab 3D turbo/fast spin echo (SE) imaging with very long echo trains was recently introduced with slab selection using a highly selective excitation pulse and short, nonselective refocusing pulses with variable flip angles for high imaging efficiency. This technique, however, is vulnerable to image degradation ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22070

    authors: Park J,Mugler JP 3rd,Hughes T

    更新日期:2009-10-01 00:00:00

  • On the steady-state properties of actual flip angle imaging (AFI).

    abstract::AFI (actual flip angle imaging) represents an interesting approach to map the B(1) transmit fields by measuring the spatial variations of the effective flip angle. However, the accuracy of the technique relies on the adequate spoiling of transverse magnetization. In the present work configuration theory was employed t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21592

    authors: Nehrke K

    更新日期:2009-01-01 00:00:00

  • Three-dimensional diffusion tensor microimaging for anatomical characterization of the mouse brain.

    abstract::Diffusion tensor imaging is gaining increasing importance for anatomical imaging of the developing mouse brain. However, the application of diffusion tensor imaging to mouse brain imaging at microscopic levels is hindered by the limitation on achievable spatial resolution. In this study, fast diffusion tensor microima...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22426

    authors: Aggarwal M,Mori S,Shimogori T,Blackshaw S,Zhang J

    更新日期:2010-07-01 00:00:00

  • 3D single-shot VASO using a Maxwell gradient compensated GRASE sequence.

    abstract::The vascular space occupancy (VASO) method was recently proposed as a functional MRI (fMRI) method that is capable of detecting activation-related changes in blood volume (CBV), without the need for a blood-pool contrast agent. In the present work we introduce a new whole-brain VASO technique that is based on a parall...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22000

    authors: Poser BA,Norris DG

    更新日期:2009-07-01 00:00:00

  • Multifrequency selective rf pulses for multislice MR imaging.

    abstract::A method is described for multislice imaging by means of rf pulses which contain a multifrequency excitation spectrum. These pulses label each slice by an individual signal phase and allow the separation of the signals from all the slices by subsequent add/subtract procedures. The image sensitivity corresponds to the ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910060315

    authors: Müller S

    更新日期:1988-03-01 00:00:00

  • Inductively coupled Helmholtz coil on a dedicated imaging platform for the in vivo 1H-MRS measurement of intramyocellular lipids in the hind leg of rats.

    abstract::Skeletal muscle triglycerides are markers for insulin resistance in type 2 diabetes. Recently, MR spectroscopy was adapted for in vivo measurement of triglycerides in animal models and for the characterization of new therapeutic approaches. Because of small MR spectroscopy voxel sizes used in skeletal muscles, surface...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22149

    authors: Neumaier M,Niessen HG,Kaulisch T,Stiller D

    更新日期:2009-10-01 00:00:00

  • Comprehensive quantification of signal-to-noise ratio and g-factor for image-based and k-space-based parallel imaging reconstructions.

    abstract::Parallel imaging reconstructions result in spatially varying noise amplification characterized by the g-factor, precluding conventional measurements of noise from the final image. A simple Monte Carlo based method is proposed for all linear image reconstruction algorithms, which allows measurement of signal-to-noise r...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21728

    authors: Robson PM,Grant AK,Madhuranthakam AJ,Lattanzi R,Sodickson DK,McKenzie CA

    更新日期:2008-10-01 00:00:00

  • Tracer kinetic modeling in myocardial perfusion quantification using MRI.

    abstract:PURPOSE:To investigate and compare several quantification methods of myocardial perfusion measurements, paying special attention to the relation between the techniques and the required measurement duration. METHODS:Seven patients underwent contrast-enhanced rest and stress cardiac perfusion measurements at 3T. Three s...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章,随机对照试验

    doi:10.1002/mrm.25212

    authors: Schwab F,Ingrisch M,Marcus R,Bamberg F,Hildebrandt K,Adrion C,Gliemi C,Nikolaou K,Reiser M,Theisen D

    更新日期:2015-03-01 00:00:00

  • Phosphonate-modified GdDTPA complexes. I. NMRD study of the solution behavior of new tissue-specific contrast agents.

    abstract::NMRD profiles, the magnetic field dependence of the water proton longitudinal relaxation rates, have been acquired for two new diphosphonate-modified GdDTPA complexes currently under evaluation as relaxation agents for the MRI detection of soft-tissue calcifications. Fresh dilute solutions show profiles identical to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910170118

    authors: Adzamli IK,Blau M

    更新日期:1991-01-01 00:00:00

  • Correction for partial volume errors in MR heart perfusion imaging.

    abstract::Myocardial MR first-pass perfusion time courses are contaminated by signals from the ventricles (spillover) as a consequence of partial volume effects and motion. An early increase in the signal intensity from the myocardium is an indicator of contamination. This contamination leads to under- or overestimation of perf...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20015

    authors: Köstler H,Ritter C,Reiss-Zimmermann M,Beer M,Hahn D,Sandstede J

    更新日期:2004-04-01 00:00:00

  • Absolute oxygen tension (pO(2)) in murine fatty and muscle tissue as determined by EPR.

    abstract::The absolute partial pressure of oxygen (pO(2)) in the mammary gland pad and femoral muscle of female mice was measured using EPR oximetry at 700 MHz. A small quantity of lithium phthalocyanine (LiPc) crystals was implanted in both mammary and femoral muscle tissue of female C3H mice. Subsequent EPR measurements were ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20714

    authors: Matsumoto A,Matsumoto S,Sowers AL,Koscielniak JW,Trigg NJ,Kuppusamy P,Mitchell JB,Subramanian S,Krishna MC,Matsumoto K

    更新日期:2005-12-01 00:00:00

  • Ultrahigh field single-refocused diffusion weighted imaging using a matched-phase adiabatic spin echo (MASE).

    abstract:PURPOSE:To improve ultrahigh field diffusion-weighted imaging (DWI) in the presence of inhomogeneous transmit B1 field by designing a novel semi-adiabatic single-refocused DWI technique. METHODS:A 180° slice-selective, adiabatic radiofrequency (RF) pulse of 4 ms duration was designed using the adiabatic Shinnar-Le Rou...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25790

    authors: Dyvorne H,O'Halloran R,Balchandani P

    更新日期:2016-05-01 00:00:00

  • Solvate structures in water-methanol solutions of MRI contrast agents: electron spin echo envelope modulation in gadolinium chelates.

    abstract::Electron Spin Echo Envelope Modulation (ESEEM) data are reported for three gadolinium (III) chelates, Gd-EDTA, Gd-DTPA, and Gd-TTHA, in frozen D2O/CH3OD glasses. This series includes Gd-DTPA, an MRI contrast agent that is in clinical use. Three-pulse electron spin echo modulation patterns can be modeled to yield geome...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290414

    authors: Clarkson RB,Hwang JH,Belford RL

    更新日期:1993-04-01 00:00:00

  • Functional magnetic resonance imaging in real time (FIRE): sliding-window correlation analysis and reference-vector optimization.

    abstract::New algorithms for correlation analysis are presented that allow the mapping of brain activity from functional MRI (fMRI) data in real time during the ongoing scan. They combine the computation of the correlation coefficients between measured fMRI time-series data and a reference vector with "detrending", a technique ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1522-2594(200002)43:2<259::aid-mrm13

    authors: Gembris D,Taylor JG,Schor S,Frings W,Suter D,Posse S

    更新日期:2000-02-01 00:00:00

  • Fully balanced steady-state 3D-spin-echo (bSSSE) imaging at 3 Tesla.

    abstract::In this work a 3D fully balanced steady-state spin-echo sequence (bSSSE) was designed and implemented on a 3-Tesla whole-body MR scanner. In contrast to previously introduced nonbalanced SSSE (nbSSSE) sequences, bSSSE features fully rewound imaging gradients. Additionally, all phase encodings and the readout prephasin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21037

    authors: Krug R,Han ET,Banerjee S,Majumdar S

    更新日期:2006-11-01 00:00:00

  • Toward direct mapping of neuronal activity: MRI detection of ultraweak, transient magnetic field changes.

    abstract::A novel method based on selective detection of rapidly changing DeltaB(0) magnetic fields and suppression of slowly changing DeltaB(0) fields is presented. The ultimate goal of this work is to present a method that may allow detection of transient and subtle changes in B(0) in cortical tissue associated with electrica...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10159

    authors: Bodurka J,Bandettini PA

    更新日期:2002-06-01 00:00:00

  • Dynamic imaging with multiple resolutions along phase-encode and slice-select dimensions.

    abstract::An implementation is reported of an imaging method to obtain MUltiple Resolutions along Phase-encode and Slice-select dimensions (MURPS), which enables dynamic imaging of focal changes using a graded, multiresolution approach. MURPS allows one to trade spatial resolution in part of the volume for improved temporal res...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1126

    authors: Panych LP,Zhao L,Jolesz FA,Mulkern RV

    更新日期:2001-06-01 00:00:00

  • The field dependence of NMR imaging. II. Arguments concerning an optimal field strength.

    abstract::Some of the factors involved in the choice of field strength for NMR imaging are examined. The influences of relaxation times and chemical shift upon image quality and signal-to-noise ratio are highlighted, and power deposition is introduced as a significant factor which may limit the flexibility and information avail...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910030509

    authors: Hoult DI,Chen CN,Sank VJ

    更新日期:1986-10-01 00:00:00

  • Positive contrast visualization of iron oxide-labeled stem cells using inversion-recovery with ON-resonant water suppression (IRON).

    abstract::In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21399

    authors: Stuber M,Gilson WD,Schär M,Kedziorek DA,Hofmann LV,Shah S,Vonken EJ,Bulte JW,Kraitchman DL

    更新日期:2007-11-01 00:00:00

  • Noise removal in magnetic resonance diffusion tensor imaging.

    abstract::Although promising for visualizing the structure of ordered tissues, MR diffusion tensor imaging (DTI) has been hampered by long acquisition time and low spatial resolution associated with its inherently low signal-to-noise ratio (SNR). Moreover, the uncertainty in the DTI measurements has a direct impact on the accur...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20582

    authors: Chen B,Hsu EW

    更新日期:2005-08-01 00:00:00

  • In vivo quantitative three-dimensional motion mapping of the murine myocardium with PC-MRI at 17.6 T.

    abstract::This work presents a method that allows for the assessment of 3D murine myocardial motion in vivo at microscopic resolution. Phase-contrast (PC) magnetic resonance imaging (MRI) at 17.6 T was applied to map myocardial motion in healthy mice along three gradient directions. High-resolution velocity maps were acquired a...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20866

    authors: Herold V,Mörchel P,Faber C,Rommel E,Haase A,Jakob PM

    更新日期:2006-05-01 00:00:00

  • Modulation of water diffusion during gonadotropin-induced ovulation: NMR microscopy of the ovarian follicle.

    abstract::The preovulatory rat follicle reaches a diameter of 1 mm with no internal blood vessels. Nutrient supply to the enclosed oocyte depends solely on passive diffusion across the follicular wall and the follicular fluid. Spin-echo and stimulated-echo NMR microscopy experiments were applied here for studying modulations in...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910340212

    authors: Tempel C,Schiffenbauer YS,Meir G,Neeman M

    更新日期:1995-08-01 00:00:00

  • 31P nuclear magnetic resonance study of acute renal dysfunction in rat kidney transplants.

    abstract::31P NMR spectroscopy was used to study renal allografts in rats subjected to allograft rejection, cyclosporine toxicity, ischemia, and ureteral obstruction. Parameters of relative peak areas and intracellular pH were accurately distinguished among the different causes of graft dysfunction. Ureteral obstruction was cle...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910050405

    authors: Shapiro JI,Haug CE,Weil R 3rd,Chan L

    更新日期:1987-10-01 00:00:00

  • Comparison between 2D and 3D gradient-echo sequences for MRI of human lung ventilation with hyperpolarized 3He.

    abstract::Images of hyperpolarized 3He were acquired during breath-hold in four healthy volunteers with the use of an optimized 3D gradient-echo sequence. The images were compared with existing 2D gradient-echo methods. The average SNR from a 13-mm-thick slice in the peripheral lung was 1.4 times greater with 3D. In the airways...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20164

    authors: Wild JM,Woodhouse N,Paley MN,Fichele S,Said Z,Kasuboski L,van Beek EJ

    更新日期:2004-09-01 00:00:00

  • Single acquisition electrical property mapping based on relative coil sensitivities: A proof-of-concept demonstration.

    abstract:PURPOSE:All methods presented to date to map both conductivity and permittivity rely on multiple acquisitions to compute quantitatively the magnitude of radiofrequency transmit fields, B1+. In this work, we propose a method to compute both conductivity and permittivity based solely on relative receive coil sensitivitie...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25399

    authors: Marques JP,Sodickson DK,Ipek O,Collins CM,Gruetter R

    更新日期:2015-07-01 00:00:00

  • T2 accuracy on a whole-body imager.

    abstract::MR oximetry requires a T2 measurement that is accurate within 5% in vivo. Simple methods are susceptible to signal loss and tend to underestimate T2. Current methods utilize RF pulses or RF cycling patterns that prevent signal loss at each data acquisition. However, using these methods with imperfect pulses, T2 tends ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910380512

    authors: Foltz WD,Stainsby JA,Wright GA

    更新日期:1997-11-01 00:00:00

  • Apparent propagator anisotropy from single-shell diffusion MRI acquisitions.

    abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28620

    authors: Aja-Fernández S,Tristán-Vega A,Jones DK

    更新日期:2020-12-13 00:00:00

  • Neurobehavioral effects among subjects exposed to high static and gradient magnetic fields from a 1.5 Tesla magnetic resonance imaging system--a case-crossover pilot study.

    abstract::The interactive use of magnetic resonance imaging (MRI) techniques is increasing in operating theaters. A study was performed on 17 male company volunteers to assess the neurobehavioral effects of exposure to magnetic fields from a 1.5 Tesla MRI system. The subjects' neurobehavioral performances on a neurobehavioral t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10604

    authors: de Vocht F,van-Wendel-de-Joode B,Engels H,Kromhout H

    更新日期:2003-10-01 00:00:00

  • Strategy for the spectral filtering of myo-inositol and other strongly coupled spins.

    abstract::A multiple quantum filter strategy is presented for spectrally discriminating metabolites with strongly coupled spins from those whose spins are either uncoupled or weakly coupled. The strategy also includes a means for selectively suppressing the background multiplets of metabolites that also have strongly coupled sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10697

    authors: Kim H,Wild JM,Allen PS

    更新日期:2004-02-01 00:00:00