Development of a side-view chamber for studying cell-surface adhesion under flow conditions.

Abstract:

:Observing microscopic specimens is often useful in studies of cellular interaction with a vascular wall. We have developed an in vitro side-view flow chamber that permits observations from the side of the cell's contact with various adhesive surfaces under dynamic flow conditions. This side-view flow chamber consists of two precision rectangular glass tubes called microslides. A smaller microslide is inserted into a larger one to create a flow channel with a flat surface on which either cultured vascular endothelium can be grown or purified adhesion molecules can be coated. Two optical prisms with a 45 degrees chromium-coated surface are used along the flow channel to generate light illumination and observation pathways. The side-view images of cell-substrate contact can be obtained using a light microscope. This design allows us not only to measure the effects of flow on cell-surface adhesion strength, but also to have close observation of cell deformation and adhesive contact to various surfaces in shear flow. In addition, this chamber can readily serve for a conventional top-view flow channel, similar to the parallel-plate flow chambers used in many areas. The development of such a side-view flow chamber can be beneficial to various in vitro applications in cellular studies that require an edge view, especially for various cell interactions with cultured vascular endothelium or surfaces containing single-type adhesive molecules under flow conditions.

journal_name

Ann Biomed Eng

authors

Cao J,Usami S,Dong C

doi

10.1007/BF02684196

subject

Has Abstract

pub_date

1997-05-01 00:00:00

pages

573-80

issue

3

eissn

0090-6964

issn

1573-9686

journal_volume

25

pub_type

杂志文章
  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • Sensor Anchoring Improves the Correlation Between Intramuscular Pressure and Muscle Tension in a Rabbit Model.

    abstract::Intramuscular pressure (IMP) shows promise for estimating individual muscle tension in vivo. However, previous pressure measurements show high variability during isometric contraction and poor correlation with tension during dynamic contraction. We hypothesized that enhanced sensor anchoring/orientation would improve ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02633-7

    authors: O'Connor SM,Kaufman KR,Ward SR,Lieber RL

    更新日期:2021-02-01 00:00:00

  • The Effects of 4%Fe on the Performance of Pure Zinc as Biodegradable Implant Material.

    abstract::The efforts to develop structural materials for biodegradable metal implants have lately shifted their focus from Magnesium and Iron base alloys towards Zinc. This was mainly due to the accelerated corrosion rate of Mg that is accompanied by hydrogen gas evolution, formation of voluminous iron oxide products with redu...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-019-02245-w

    authors: Kafri A,Ovadia S,Yosafovich-Doitch G,Aghion E

    更新日期:2019-06-01 00:00:00

  • Optimization of pulse train duration for the electrical stimulation of a skeletal muscle ventricle in the dog.

    abstract::The optimal means of electrically stimulating a skeletal muscle to contract around a fluid-filled pouch (i.e., a skeletal muscle ventricle [SMV]) has not been determined. A SMV was made from the latissimus dorsi muscle in five dogs and the rectus abdominis muscle in five dogs, and each SMV was electrically stimulated ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02364611

    authors: Badylak SF,Wessale JE,Geddes LA,Janas W

    更新日期:1990-01-01 00:00:00

  • Quantification of rigidity in Parkinson's disease.

    abstract::In this paper, a new method for quantification of rigidity in elbow joint of Parkinsonian patients is introduced. One of the most known syndromes in Parkinson's disease (PD) is increased passive stiffness in muscles, which leads to rigidity in joints. Clinical evaluation of stiffness in wrist and/or elbow, commonly us...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9379-6

    authors: Sepehri B,Esteki A,Ebrahimi-Takamjani E,Shahidi GA,Khamseh F,Moinodin M

    更新日期:2007-12-01 00:00:00

  • Permeability of endothelial and astrocyte cocultures: in vitro blood-brain barrier models for drug delivery studies.

    abstract::The blood-brain barrier (BBB) is a major obstacle for drug delivery to the brain. To seek for in vitro BBB models that are more accessible than animals for investigating drug transport across the BBB, we compared four in vitro cultured cell models: endothelial monoculture (bEnd3 cell line), coculture of bEnd3 and prim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0023-5

    authors: Li G,Simon MJ,Cancel LM,Shi ZD,Ji X,Tarbell JM,Morrison B 3rd,Fu BM

    更新日期:2010-08-01 00:00:00

  • The role of airway epithelium in replenishment of evaporated airway surface liquid from the human conducting airways.

    abstract::This article presents a multi-scale computational model describing the transport of water vapor and heat within the human conducting airways and its interaction with cellular fluid transport kinetics. This tight coupling between the cell and the evaporative flux allows the periciliary liquid (PCL) depth to be investig...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0111-6

    authors: Warren NJ,Crampin EJ,Tawhai MH

    更新日期:2010-12-01 00:00:00

  • Effect of mechanical strain on solute diffusion in human TMJ discs: an electrical conductivity study.

    abstract::This study investigated the effect of mechanical strain on solute diffusion in human TMJ discs (mean cadaver age 77.8) using the electrical conductivity method. The electrical conductivity, as well as small ion diffusivity, of male and female TMJ discs was determined under three compressive strains. In the male group,...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0840-4

    authors: Wright GJ,Kuo J,Shi C,Bacro TR,Slate EH,Yao H

    更新日期:2013-11-01 00:00:00

  • Intelligent self-tuning of PID control for the robotic testing system for human musculoskeletal joints test.

    abstract::In this paper, an intelligent proportional-integral-derivative (PID) control method is introduced to the robotic testing system for the biomechanical study of human musculoskeletal joints. For the testing system, the robot is a highly nonlinear and heavily coupled complicated system, and the human spinal specimen also...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000030759.80354.e8

    authors: Tian L

    更新日期:2004-06-01 00:00:00

  • Transport Analysis of Engineered Liver Tissue Fabricated Using a Capsule-Based, Modular Approach.

    abstract::The bioinspired, microscale tissue engineering approach has emerged in recent years as a promising alternative to preformed scaffolds. Using this approach, complex tissues and organs can be efficiently engineered from microscale modules to replicate the intricate architecture and physiology of vascularized organs and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02192-y

    authors: Annamalai RT,Matthew HWT

    更新日期:2019-05-01 00:00:00

  • Insulin minimal model indexes and secretion: proper handling of uncertainty by a Bayesian approach.

    abstract::The identification of the insulin minimal model (MM) for the estimation of insulin secretion rate (ISR) and physiological indexes (e.g. beta-cell sensitivity) requires the knowledge of C-peptide (CP) kinetics. The four parameters of the two-compartment model of CP kinetics in a given individual can be derived either f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1023/b:abme.0000032465.75888.91

    authors: Magni P,Sparacino G,Bellazzi R,Toffolo GM,Cobelli C

    更新日期:2004-07-01 00:00:00

  • Multi-scale computational models of pro-angiogenic treatments in peripheral arterial disease.

    abstract::The induction of angiogenesis is a promising therapeutic strategy for the amelioration of peripheral arterial disease (PAD). This occlusive disease results in muscle ischemia, and neovascularization is a route to increasing the perfusion in the tissue. The vascular endothelial growth factor (VEGF) family of potent pro...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-007-9303-0

    authors: Mac Gabhann F,Ji JW,Popel AS

    更新日期:2007-06-01 00:00:00

  • Mesh Convergence Behavior and the Effect of Element Integration of a Human Head Injury Model.

    abstract::Numerous head injury models exist that vary in mesh density by orders of magnitude. A careful study of the mesh convergence behavior is necessary, especially in terms of strain most relevant to brain injury. To this end, as well as to investigate the effect of element integration scheme on simulated strains, we re-mes...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-02159-z

    authors: Zhao W,Ji S

    更新日期:2019-02-01 00:00:00

  • Concussion Risk Between Individual Football Players: Survival Analysis of Recurrent Events and Non-events.

    abstract::Concussion tolerance and head impact exposure are highly variable among football players. Recent findings highlight that head impact data analyses need to be performed at the subject level. In this paper, we describe a method of characterizing concussion risk between individuals using a new survival analysis technique...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02675-x

    authors: Rowson S,Campolettano ET,Duma SM,Stemper B,Shah A,Harezlak J,Riggen L,Mihalik JP,Brooks A,Cameron KL,Svoboda SJ,Houston MN,McAllister T,Broglio S,McCrea M

    更新日期:2020-11-01 00:00:00

  • A review of the role of the partial pressure of carbon dioxide in mechanically loaded tissues: the canary in the cage singing in tune with the pressure ulcer mantra.

    abstract::Pressure ulcers (PUs) can occur in any situations where people are subjected to non-uniform distribution of pressure over a prolonged period. They can have devastating effects on the patients' well-being and in extreme conditions can prove fatal. In addition to traditional wisdom implicating mechanically induced ischa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1007/s10439-014-1233-z

    authors: Mirtaheri P,Gjøvaag T,Worsley PR,Bader DL

    更新日期:2015-02-01 00:00:00

  • Novel organotypic cultures of human skin explants with an implant-tissue biomaterial interface.

    abstract::A novel in vitro culture system of organotypic human skin explants interfacing with external fixator pins is presented. The system was used to observe changes in skin morphology on the skin at the pin interface. To evaluate the performance of this novel system, histological analysis of human skin explants cultured for...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9614-9

    authors: Peramo A,Marcelo CL,Goldstein SA,Martin DC

    更新日期:2009-02-01 00:00:00

  • Biomechanical Characterisation of the Human Auricular Cartilages; Implications for Tissue Engineering.

    abstract::Currently, autologous cartilage provides the gold standard for auricular reconstruction. However, synthetic biomaterials offer a number of advantages for ear reconstruction including decreased donor site morbidity and earlier surgery. Critical to implant success is the material's mechanical properties as this affects ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1688-1

    authors: Griffin MF,Premakumar Y,Seifalian AM,Szarko M,Butler PE

    更新日期:2016-12-01 00:00:00

  • Vortex ring formation in the left ventricle of the heart: analysis by 4D flow MRI and Lagrangian coherent structures.

    abstract::Recent studies suggest that vortex ring formation during left ventricular (LV) rapid filling is an optimized mechanism for blood transport, and that the volume of the vortex ring is an important measure. However, due to lack of quantitative methods, the volume of the vortex ring has not previously been studied. Lagran...

    journal_title:Annals of biomedical engineering

    pub_type: 临床试验,杂志文章

    doi:10.1007/s10439-012-0615-3

    authors: Töger J,Kanski M,Carlsson M,Kovács SJ,Söderlind G,Arheden H,Heiberg E

    更新日期:2012-12-01 00:00:00

  • How crouch gait can dynamically induce stiff-knee gait.

    abstract::Children with cerebral palsy frequently experience foot dragging and tripping during walking due to a lack of adequate knee flexion in swing (stiff-knee gait). Stiff-knee gait is often accompanied by an overly flexed knee during stance (crouch gait). Studies on stiff-knee gait have mostly focused on excessive knee mus...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9952-2

    authors: van der Krogt MM,Bregman DJ,Wisse M,Doorenbosch CA,Harlaar J,Collins SH

    更新日期:2010-04-01 00:00:00

  • MUlti-Dimensional Spline-Based Estimator (MUSE) for motion estimation: algorithm development and initial results.

    abstract::Image registration and motion estimation play central roles in many fields, including RADAR, SONAR, light microscopy, and medical imaging. Because of its central significance, estimator accuracy, precision, and computational cost are of critical importance. We have previously presented a highly accurate, spline-based ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9564-2

    authors: Viola F,Coe RL,Owen K,Guenther DA,Walker WF

    更新日期:2008-12-01 00:00:00

  • Measurement of signal and noise characteristics in ongoing auditory brainstem response averaging.

    abstract::Although diagnostic testing with auditory evoked potentials (EPs) has become routine, quantitative measurements of signal and noise are still lacking. In this study, current signal, power, noise power, and signal-to-noise ratio (SNR) estimation formulas are reviewed and applied to auditory brainstem response averaging...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684183

    authors: Ozdamar O,Delgado RE

    更新日期:1996-11-01 00:00:00

  • A Wearable Magnet-Based System to Assess Activity and Joint Flexion in Humans and Large Animals.

    abstract::Functional outcomes, such as joint flexion and gait, are important indicators of efficacy in musculoskeletal research. Current technologies that objectively assess these parameters, including visual tracking systems and force plates, are challenging to deploy in long-term translational and clinical studies. To that en...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-018-2105-8

    authors: Qu F,Stoeckl BD,Gebhard PM,Hullfish TJ,Baxter JR,Mauck RL

    更新日期:2018-12-01 00:00:00

  • Cerebrovascular transmural pressure and autoregulation.

    abstract::The cerebral blood flow (CBF) response to changes in perfusion pressure mediated through decreases in arterial pressure, increases in cerebrospinal fluid (CSF) pressure and increases in jugular venous pressure was studied in anesthetized dogs. A preparation was developed in which each of the three relevant pressures c...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584249

    authors: Wagner EM,Traystman RJ

    更新日期:1985-01-01 00:00:00

  • A finite volume method for modeling discontinuous electrical activation in cardiac tissue.

    abstract::This paper describes a finite volume method for modeling electrical activation in a sample of cardiac tissue using the bidomain equations. Microstructural features to the level of cleavage planes between sheets of myocardial fibers in the tissue are explicitly represented. The key features of this implementation compa...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-1434-6

    authors: Trew M,Le Grice I,Smaill B,Pullan A

    更新日期:2005-05-01 00:00:00

  • A direct compression stimulator for articular cartilage and meniscal explants.

    abstract::This paper describes the development and use of a direct compression stimulator for culturing explants from the meniscus of the knee and articular cartilage. Following design and fabrication of the instrument along with its data acquisition system, the function of the machine was verified by both mechanical means and ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9157-x

    authors: Aufderheide AC,Athanasiou KA

    更新日期:2006-09-01 00:00:00

  • Finite element modeling of coupled diffusion with partitioning in transdermal drug delivery.

    abstract::The finite element method is employed to simulate two-dimensional (axisymmetric) drug diffusion from a finite drug reservoir into the skin. The numerical formulation is based on a general mathematical model for multicomponent nonlinear diffusion that takes into account the coupling effects between the different compon...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-5788-6

    authors: Rim JE,Pinsky PM,van Osdol WW

    更新日期:2005-10-01 00:00:00

  • Behavior of human mesenchymal stem cells in fibrin-based vascular tissue engineering constructs.

    abstract::A limitation of current tissue engineering vascular graft technology is the provision of an expandable, autologous cell source. By harnessing the multipotency of mesenchymal stem cells (MSC), it is hoped that functional vascular cells can be produced. To date, a range of 2D and 3D environments have been investigated f...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9912-x

    authors: O'Cearbhaill ED,Murphy M,Barry F,McHugh PE,Barron V

    更新日期:2010-03-01 00:00:00

  • A model for detecting balance impairment and estimating falls risk in the elderly.

    abstract::Traumatic falls are a prevalent and costly threat to elderly adults. Accurate risk assessment is necessary for reducing incidence of falls. The objective of this study was to test the feasibility of a balance impairment detection model using tasks of sample categorization and falls risk estimation. Model design includ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-2867-7

    authors: Hahn ME,Chou LS

    更新日期:2005-06-01 00:00:00

  • Left ventricular external constraint: relationship between pericardial, pleural and esophageal pressures during positive end-expiratory pressure and volume loading in dogs.

    abstract::Left ventricular (LV) diastolic filling is limited by the constraining effects exerted by the pericardium (PE) and the lung/chest wall. The aim of the present study was to assess the validity of various estimates of external cardiac constraint, compared to pericardial surface pressure (Ppe) measured lateral to the LV ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02584288

    authors: Kingma I,Smiseth OA,Frais MA,Smith ER,Tyberg JV

    更新日期:1987-01-01 00:00:00

  • Velocity measurements within confined turbulent jets: application to cardiovalvular regurgitation.

    abstract::An expression for centerline mean velocity distributions for circular and noncircular confined turbulent jets has been obtained by assuming self-preservation of flow downstream of the jet potential core. It was assumed that the velocity decay was not only dependent on the streamwise distance x in terms of x/d, as in t...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:

    authors: Liu H,Winoto SH,Shah DA

    更新日期:1997-11-01 00:00:00