Erroneous continuous cardiac output by calibrated pulse contour analysis.

Abstract:

:Pulse contour analysis techniques are used for beat-to-beat tracking of cardiac output in critically ill patients. However, an adequate pulse pressure waveform signal and identification of the appropriate (i.e. systolic) part of the waveform by the monitor are crucial for correct calculation of continuous cardiac output. We observed a case where the monitor failed to correctly identify the systolic part of the waveform during tachycardia thus giving false readings. We would like to emphasize the importance of visually checking the waveform for any irregularities that may cause erroneous calculations before initiating a therapy based on these values. One advantage of the system used here is that the part of the pressure curve used for analysis is automatically indicated.

journal_name

J Clin Monit Comput

authors

Grensemann J,Wappler F,Sakka SG

doi

10.1007/s10877-013-9470-5

subject

Has Abstract

pub_date

2013-10-01 00:00:00

pages

567-8

issue

5

eissn

1387-1307

issn

1573-2614

journal_volume

27

pub_type

杂志文章
  • Determining the artifact sensitivity of recent pulse oximeters during laboratory benchmarking.

    abstract::This study aimed to investigate and compare the performance of the algorithms contained in the newest generation of pulse oximeters (Masimo SET in IVY2000, Nellcor Oxismart N-3000, Agilent M3 rev. B) against a traditional pulse oximeter (Agilent CMS rel. A.0). The benchmark was performed in an efficient and reproducib...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1011420228523

    authors: Kästle SW,Konecny E

    更新日期:2000-01-01 00:00:00

  • Clinical evaluation of stretchable and wearable inkjet-printed strain gauge sensor for respiratory rate monitoring at different measurements locations.

    abstract::The respiration rate (RR) is a vital sign in physiological measurement and clinical diagnosis. RR can be measured using stretchable and wearable strain gauge sensors which detect the respiratory movements in the abdomen or thorax areas caused by volumetric changes. In different body locations, the accuracy of RR detec...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00481-3

    authors: Al-Halhouli A,Al-Ghussain L,El Bouri S,Liu H,Zheng D

    更新日期:2020-02-22 00:00:00

  • Focus on renal blood flow in mechanically ventilated patients with SARS-CoV-2: a prospective pilot study.

    abstract::Mechanically ventilated patients with ARDS due to the severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) seem particularly susceptible to AKI. Our hypothesis was that the renal blood flow could be more compromised in SARS-CoV-2 patients than in patients with "classical" ARDS. We compared the renal resistivit...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-020-00633-5

    authors: Fogagnolo A,Grasso S,Dres M,Gesualdo L,Murgolo F,Morelli E,Ottaviani I,Marangoni E,Volta CA,Spadaro S

    更新日期:2021-01-01 00:00:00

  • An algorithm for the detection of individual breaths from the pulse oximeter waveform.

    abstract:OBJECTIVES:To determine if wavelet analysis techniques can be used to reliably identify individual breaths from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 22 healthy adult volunteers timing their respiration rate in synchronisation with a metronome. A secondary timing signal was obtai...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-2697-z

    authors: Leonard P,Grubb NR,Addison PS,Clifton D,Watson JN

    更新日期:2004-12-01 00:00:00

  • Transcranial Doppler monitoring compared with invasive monitoring of intracranial pressure during acute intracranial hypertension.

    abstract:OBJECTIVE:To determine whether a simple transcanial Doppler waveform variable-pulsatility difference (systolic - diastolic blood flow velocity) can serve as a measure of critical changes in cerebral perfusion. METHODS:Thirteen pigs were anesthetized (anesthesia maintained with halothane) and ventilated to maintain nor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009993232534

    authors: Sidi A,Messinger G,Mahla ME

    更新日期:1999-05-01 00:00:00

  • Increases in voltage may produce false-negatives when using transcranial motor evoked potentials to detect an isolated nerve root injury.

    abstract:OBJECTIVE:Transcranial Motor Evoked Potentials (TcMEPs) are sometimes used during lumbar spine surgery in order to detect and prevent an intraoperative nerve root injury. Typically, a fixed stimulus is applied, and one monitors for changes in response amplitude from several myotomes. Increased stimulating voltage may o...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-010-9269-6

    authors: Lyon R,Gibson A,Burch S,Lieberman J

    更新日期:2010-12-01 00:00:00

  • In vitro performance of prefilled CO2 absorbers with the Zeus®.

    abstract::Low fresh gas flows (FGFs) decrease the use of anesthetic gases, but increase CO2 absorbent usage. CO2 absorbent usage remains poorly quantified. The goal of this study is to determine canister life of 8 commercially available CO2 absorbent prepacks with the Zeus®. Pre-packed CO2 canisters of 8 different brands were t...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0088-x

    authors: Omer M,Hendrickx JFA,De Ridder S,De Houwer A,Carette R,De Cooman S,De Wolf AM

    更新日期:2018-10-01 00:00:00

  • Assessment of pulmonary mechanics in mechanical ventilation: effects of imprecise breath detection, phase shift and noise.

    abstract:OBJECTIVE:In mechanical ventilation, the assessment of pulmonary mechanics, mainly of total compliance (Crs), total resistance (Rrs), and intrinsic positive end-expiratory pressure (PEEPint), is clinically important. By using airway pressure (Paw) and flow (V'aw), the least squares fit (LSF) method allows the continuou...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1007457829405

    authors: Stegmaier PA,Zollinger A,Brunner JX,Pasch T

    更新日期:1998-02-01 00:00:00

  • The incidence and interpretation of large differences in EIT-based measures for PEEP titration in ARDS patients.

    abstract::Positive end-expiratory pressure (PEEP) can be titrated by electrical impedance tomography (EIT). The aim of the present study was to examine the performance of different EIT measures during PEEP trials with the aim of identifying "optimum" PEEP and to provide possible interpretations of largely diverging results. Aft...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00396-8

    authors: Zhao Z,Lee LC,Chang MY,Frerichs I,Chang HT,Gow CH,Hsu YL,Möller K

    更新日期:2020-10-01 00:00:00

  • Response time of the Opti-Q continuous cardiac output pulmonary artery catheter in the urgent mode to a step change in cardiac output.

    abstract:OBJECTIVES:This study was conducted to determine the response time of the Opti-Q continuous cardiac output (CCO) device to a step change in cardiac. DESIGN:Prospective study. SETTING:University hospital animal lab. MODEL:Female sheep. INTERVENTIONS:In ten animals, cardiac output was altered suddenly by opening and ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009934112134

    authors: Goldstein LJ

    更新日期:1999-12-01 00:00:00

  • The comparison of the technical parameters in endotracheal intubation devices: the Cmac, the Vividtrac, the McGrath Mac and the Kingvision.

    abstract::Currently, there are plenty of videolaryngoscopes that appear on the market. They have different specifications. Some of these features favor the fact that they are more suited for educational purposes of future operators and others can be characterized with an excellent clinical use. In this study we compared four ty...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-015-9727-2

    authors: Cierniak M,Timler D,Wieczorek A,Sekalski P,Borkowska N,Gaszynski T

    更新日期:2016-08-01 00:00:00

  • The American Society of Neurophysiological Monitoring position statements project.

    abstract::The American Society of Neurophysiological Monitoring (ASNM) is developing position statements aimed at assisting practitioners and others in making decisions regarding neurophysiological monitoring practice. This paper describes the procedures used in drafting these documents. ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-9000-1

    authors: Morledge DE,Stecker M

    更新日期:2006-02-01 00:00:00

  • Comparison between pulse wave velocities measured using Complior and measured using Biopac.

    abstract::Arterial stiffness is a reliable prognostic parameter for cardiovascular diseases. The effect of change in arterial stiffness can be measured by the change of the pulse wave velocity (PWV). The Complior system is widely used to measure PWV between the carotid and radial arteries by means of piezoelectric clips placed ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-018-0165-9

    authors: van Velzen MHN,Stolker RJ,Loeve AJ,Niehof SP,Mik EG

    更新日期:2019-04-01 00:00:00

  • The evolution of eProtocols that enable reproducible clinical research and care methods.

    abstract::Unnecessary variation in clinical care and clinical research reduces our ability to determine what healthcare interventions are effective. Reducing this unnecessary variation could lead to further healthcare quality improvement and more effective clinical research. We have developed and used electronic decision suppor...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9356-y

    authors: Blagev DP,Hirshberg EL,Sward K,Thompson BT,Brower R,Truwit J,Hite D,Steingrub J,Orme JF Jr,Clemmer TP,Weaver LK,Thomas F,Grissom CK,Sorenson D,Sittig DF,Wallace CJ,East TD,Warner HR,Morris AH

    更新日期:2012-08-01 00:00:00

  • Validation of a mathematical model for understanding intracranial pressure curve morphology.

    abstract::The physiology underlying the intracranial pressure (ICP) curve morphology is not fully understood. Recent research has suggested that the morphology could be dependent on arterial cerebral inflow and the physiological and pathophysiological properties of the intracranial cavity. If understood, the ICP curve could pro...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00342-8

    authors: Unnerbäck M,Ottesen JT,Reinstrup P

    更新日期:2020-06-01 00:00:00

  • Perioperative echocardiography-guided hemodynamic therapy in high-risk patients: a practical expert approach of hemodynamically focused echocardiography.

    abstract::The number of high-risk patients undergoing surgery is growing. To maintain adequate hemodynamic functioning as well as oxygen delivery to the vital organs (DO2) amongst this patient population, a rapid assessment of cardiac functioning is essential for the anesthesiologist. Pinpointing any underlying cardiovascular p...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-020-00534-7

    authors: Trauzeddel RF,Ertmer M,Nordine M,Groesdonk HV,Michels G,Pfister R,Reuter D,Scheeren TWL,Berger C,Treskatsch S

    更新日期:2020-05-26 00:00:00

  • Time-variant investigation of quadratic phase couplings caused by amplitude modulation in electroencephalic burst-suppression patterns.

    abstract:OBJECTIVE:Several studies suggest that parameters derived from bispectral analysis of the EEG can be used to characterize specific cortical activation states represented by non linear interaction between brain electrical oscillations. For example, it was shown that so-called bispectral indices can be used to assess the...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1016362209175

    authors: Arnold M,Witte H,Schelenz C

    更新日期:2002-02-01 00:00:00

  • Oesophageal balloon calibration during pressure support ventilation: a proof of concept study.

    abstract::Oesophageal balloon calibration improves the oesophageal pressure (Pes) assessment during invasive controlled mechanical ventilation. The primary aim of the present investigation was to ascertain the feasibility of oesophageal balloon calibration during pressure support ventilation (PSV). Secondarily, the calibrated P...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00436-3

    authors: Cammarota G,Verdina F,Santangelo E,Lauro G,Boniolo E,Tarquini R,Spinelli E,Zanoni M,Garofalo E,Bruni A,Pesenti A,Della Corte F,Navalesi P,Vaschetto R,Mauri T

    更新日期:2020-12-01 00:00:00

  • Does the EEG during isoflurane/alfentanil anesthesia differ from linear random data?

    abstract:OBJECTIVE:Bispectral analysis of the electroencephalogram (EEG) has been used to monitor depth of anesthesia. In the majority of publications this has been done using the so called Bispectral (BIS) Index. The exact relation of this index to bispectral quantities like the bispectrum and its normalized version the bicohe...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1026284321451

    authors: Schwilden H,Jeleazcov C

    更新日期:2002-12-01 00:00:00

  • Sampling intervals to record severe hypotensive and hypoxic episodes in anesthetised patients.

    abstract:OBJECTIVE:To define the longest sampling interval which will faithfully record the time course of episodes of severe hypotension and hypoxia in anesthetised patients. METHODS:Electronic anesthetic records of 1501 patients were analyzed retrospectively for hypotension where measured systolic blood pressure fell to 60 m...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009978414365

    authors: Derrick JL,Bassin DJ

    更新日期:1998-07-01 00:00:00

  • Evaluation of a Pitot type spirometer in helium/oxygen mixtures.

    abstract:OBJECTIVE:Mixtures of helium and oxygen are regaining a place in the treatment of obstruction of the upper and lower respiratory tract. The parenchymal changes during the course of IRDS or ARDS may also benefit from the reintroduction of helium/oxygen. In order to monitor and document the effect of low-density gas mixt...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009978816071

    authors: Søndergaard S,Kárason S,Lundin S,Stenqvist O

    更新日期:1998-08-01 00:00:00

  • Intraoperative motor evoked potential monitoring: overview and update.

    abstract::Amidst controversy about methodology and safety, intraoperative neurophysiology has entered a new era of increasingly routine transcranial and direct electrical brain stimulation for motor evoked potential (MEP) monitoring. Based on literature review and illustrative clinical experience, this tutorial aims to present ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,评审

    doi:10.1007/s10877-006-9033-0

    authors: Macdonald DB

    更新日期:2006-10-01 00:00:00

  • Atypical "tails-up" capnograph due to breach in the sampling tube of side-stream capnometer.

    abstract:OBJECTIVE:An atypical "tails-up" capnograph pattern was noticed in a patient during the use of an accidentally crushed sampling tube with a slit-like hole. We investigated the mechanics involved in the observed capnograph pattern. METHODS:Forty consenting ASA I patients of both sexes presenting for tonsillectomy were ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1023/a:1009990210114

    authors: Tripathi M,Pandey M

    更新日期:2000-01-01 00:00:00

  • Closed-loop regulation of arterial pressure after acute brain death.

    abstract::The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is ...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-017-0033-z

    authors: Soltesz K,Sjöberg T,Jansson T,Johansson R,Robertsson A,Paskevicius A,Liao Q,Qin G,Steen S

    更新日期:2018-06-01 00:00:00

  • Predictive value of the surgical pleth index for the hemodynamic responses to trachea intubation and skin incision.

    abstract::Surgical pleth index (SPI) has been widely investigated in assessing the nociceptive level. The aim of this study was to investigate the relationship between SPI level and patient responses to trachea intubation and skin incision. A total of 40 patients undergoing open abdominal general surgery were recruited for anal...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-019-00425-6

    authors: Wang M,Wang X,Bao R,Zhu WZ,Bian JJ,Deng XM,Han WJ,Wang JF

    更新日期:2020-12-01 00:00:00

  • Analgesia nociception index (ani) monitoring in patients with thoracic paravertebral block: a randomized controlled study.

    abstract::The goal of the study was to evaluate the effectiveness of analgesia nociception index (ANI) monitoring during intraoperative period for patients with thoracic paravertebral block (TPVB) undergoing breast surgery under general anesthesia. This prospective randomized trial was performed after receiving ethics committee...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章,随机对照试验

    doi:10.1007/s10877-017-0036-9

    authors: Dundar N,Kus A,Gurkan Y,Toker K,Solak M

    更新日期:2018-06-01 00:00:00

  • Cutaneous mitochondrial respirometry: non-invasive monitoring of mitochondrial function.

    abstract::The recently developed technique for measuring cutaneous mitochondrial oxygen tension (mitoPO2) by means of the Protoporphyrin IX-Triplet State Lifetime Technique (PpIX-TSLT) provides new opportunities for assessing mitochondrial function in vivo. The aims of this work were to study whether cutaneous mitochondrial mea...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-014-9628-9

    authors: Harms FA,Bodmer SI,Raat NJ,Mik EG

    更新日期:2015-08-01 00:00:00

  • A system of classification for the clinical applications of capnography.

    abstract::We have attempted to list all the clinical applications of capnography described to date and classify them into categories. From an extensive Pubmed search 46 clinical applications of capnography were listed. To classify these we used six categories- Airway, Breathing, Circulation, Anesthetic Delivery Apparatus, Homeo...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-007-9094-8

    authors: Eipe N,Tarshis J

    更新日期:2007-12-01 00:00:00

  • Impact of non invasive and beat-to-beat arterial pressure monitoring on intraoperative hemodynamic management.

    abstract::The Nexfin device allows for non-invasive beat-to-beat blood pressure monitoring (BP(NXF)). Perioperative hypotension and hypertension have been shown to be associated with poor clinical outcomes. The goal of the present study was to assess the ability of this device to decrease the duration of significant intraoperat...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-012-9344-2

    authors: Chen G,Chung E,Meng L,Alexander B,Vu T,Rinehart J,Cannesson M

    更新日期:2012-04-01 00:00:00

  • GNARE: automated system for high-throughput genome analysis with grid computational backend.

    abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...

    journal_title:Journal of clinical monitoring and computing

    pub_type: 杂志文章

    doi:10.1007/s10877-005-3463-y

    authors: Sulakhe D,Rodriguez A,D'Souza M,Wilde M,Nefedova V,Foster I,Maltsev N

    更新日期:2005-10-01 00:00:00