Abstract:
OBJECTIVES:This study aimed to characterize horizontal plane sound localization in interfering noise at different signal-to-noise ratios (SNRs) and to compare performance across normal-hearing listeners and users of unilateral and bilateral cochlear implants (CIs). CI users report difficulties with listening in noisy environments. Although their difficulties with speech understanding have been investigated in several studies, the ability to localize sounds in background noise has not extensively been examined, despite the benefits of binaural hearing being greatest in noisy situations. Sound localization is a measure of binaural processing and is thus well suited to assessing the benefit of bilateral implantation. The results will inform clinicians and implant manufacturers how to focus their efforts to improve localization with CIs in noisy situations. DESIGN:Six normal-hearing listeners, four unilateral, and 10 bilateral CI users indicated the perceived location of sound sources using a light pointer method. Target sounds were noise pulses played from one of 11 loudspeakers placed between -80 and +80 degrees in the frontal horizontal plane in the free field. Localization was assessed in quiet and in diffuse background noise at SNRs between +10 and -7 dB. Speech reception thresholds were measured and their relation to the localization results examined. RESULTS:Localization performance declined with decreasing SNR: target sounds were perceived closer to the median plane and the standard deviation of responses increased. Localization performance across groups was compared using a measure of "Spatial Resolvability" (SR). This measure gives the angular separation between two sound sources that would enable an ideal observer to correctly distinguish them 69.1% of the time. For all participants SR increased with decreasing SNR, that is, at low SNRs the spatial separation between sound sources remained distinguishable only when it was larger. Normal-hearing participants performed best, with SR between 1.4 and 5.1 degrees in quiet. Bilateral CI users showed SR between 8.3 and 43.6 degrees in quiet, corresponding approximately to the spatial resolution of normal-hearing listeners at an SNR of -5 dB. Most bilateral CI users had lost the ability to correctly determine which side the sound came from at an SNR of -3 dB. Overall, the SNR had to be at least +7 dB to achieve localization performance near to that in quiet for all bilateral CI users. No significant correlation was found between spatial resolution and speech reception thresholds, but the speech processor sensitivity setting did significantly affect performance. Unilateral CI users showed the most severe localization problems, with only two of four participants being able to correctly determine which side sounds came from in quiet. CONCLUSIONS:This study is the first to examine sound localization with CIs at various SNRs and to compare it with normal hearing. The results confirm that localization with CIs is strongly disrupted in noisy situations. Bilateral CIs were shown to be clearly superior over unilateral CIs for localization in quiet and in noisy situations. With bilateral CIs, localization declined at moderately high absolute noise levels (>63 dB SPL), suggesting that an extension of the acoustic-dynamic range to higher levels would be beneficial. The absence of a relation between speech reception thresholds and spatial resolution highlights the need for additional clinical tests to assess the binaural benefit of a second implant.
journal_name
Ear Hearjournal_title
Ear and hearingauthors
Kerber S,Seeber BUdoi
10.1097/AUD.0b013e318257607bsubject
Has Abstractpub_date
2012-07-01 00:00:00pages
445-57issue
4eissn
0196-0202issn
1538-4667journal_volume
33pub_type
杂志文章相关文献
EAR AND HEARING文献大全abstract:OBJECTIVE:The purpose of this study was to compare the accuracy of sound-direction identification in the horizontal plane by bilateral cochlear implant users when localization was measured with pink noise and with speech stimuli. DESIGN:Eight adults who were bilateral users of Nucleus 24 Contour devices participated i...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.aud.0000249910.80803.b9
更新日期:2007-02-01 00:00:00
abstract:OBJECTIVES:Audiologists regularly use serial monitoring to evaluate changes in a patient's auditory function over time. Observed changes are compared with reference standards to determine whether further clinical action is necessary. Reference standards are established in a control sample of otherwise healthy subjects ...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/AUD.0b013e31828a21b3
更新日期:2013-09-01 00:00:00
abstract::A patient-wearable, single-electrode cochlear implant was first used by a patient in 1972 at the House Ear Institute. Since early 1982, a redesigned version of this system has been in clinical use. This new system, called the 3M House cochlear implant system, consists of an implanted receiver and a patient-worn signal...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:
更新日期:1985-05-01 00:00:00
abstract:OBJECTIVE:Recent studies indicate that high-frequency amplification may provide little benefit for listeners with moderate-to-severe high-frequency hearing loss, and may even reduce speech recognition. Moore and colleagues have proposed a direct link between this lack of benefit and the presence of regions of nonfuncti...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/01.AUD.0000058148.27540.D9
更新日期:2003-04-01 00:00:00
abstract::Attenuation measurements were made using the ANSI S12.6-1984 protocol on a standard Telephonics headset with TDH-50P earphones and Model 51 cushions, Amplivox Audiocups headphone enclosures, and Peltor AudioMate headphone enclosures. Each of the enclosures housed Telephonics TDH-50P earphones with Model 51 cushions. T...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199202000-00004
更新日期:1992-02-01 00:00:00
abstract:OBJECTIVE:To evaluate the effect of artifacts on the impulse and response recordings with the video head impulse test (VHIT) and determine how many stimuli are necessary for obtaining acceptably efficient measurements. METHODS:One hundred fifty patients were examined using VHIT and their registries searched for artifa...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000849
更新日期:2020-09-01 00:00:00
abstract:OBJECTIVES:Lexical tone information provides redundant cues for the recognition of Mandarin sentences in listeners with normal hearing in quiet conditions. The contribution of lexical tones to Mandarin sentence recognition in listeners with hearing aids (HAs) is unclear. This study aimed to remove lexical tone informat...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000774
更新日期:2020-05-01 00:00:00
abstract::The purpose of this report is to describe the speech production of children participating in the Food and Drug Administration's approved clinical trials for the Nucleus multichannel cochlear implant. A significant increase in the ability to imitate nonsegmental aspects of speech was noted after using the implant; howe...
journal_title:Ear and hearing
pub_type: 临床试验,杂志文章
doi:10.1097/00003446-199108001-00007
更新日期:1991-08-01 00:00:00
abstract:OBJECTIVES:This study aimed to confirm that the brain processing of auditory stimuli in tinnitus patients is impaired (Attias, Urbach, Gold, & Shemesh, 1993). In addition, possible brain processing dysfunction in response to visual stimuli was assessed. DESIGN:Auditory and visual event-related potentials (ERPs) and re...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199608000-00004
更新日期:1996-08-01 00:00:00
abstract:OBJECTIVES:The most commonly employed speech processing strategies in cochlear implants (CIs) only extract and encode amplitude modulation (AM) in a limited number of frequency channels. proposed a novel speech processing strategy that encodes both frequency modulation (FM) and AM to improve CI performance. Using behav...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000756
更新日期:2020-03-01 00:00:00
abstract:OBJECTIVES:There are no nationally representative hearing loss (HL) prevalence data available for Canadian youth using direct measurements. The present study objectives were to estimate national prevalence of HL using audiometric pure-tone thresholds (0.5 to 8 kHz) and or distortion product otoacoustic emissions (DPOAE...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000345
更新日期:2017-01-01 00:00:00
abstract::Two studies were performed in which hearing-impaired subjects responded to the Connected Speech Test (CST). In experiment 1, 40 subjects, divided into four groups according to extent and configuration of hearing loss, responded to the CST version 1 (CSTv1). This version of the test consisted of 57 passages of connecte...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198808000-00005
更新日期:1988-08-01 00:00:00
abstract:OBJECTIVE:To demonstrate a technique for objectively calibrating bone conductors on an individual basis using distortion product otoacoustic emissions (DPOAEs). DESIGN:Individual calibrations were obtained using DPOAEs recorded from a single ear of 21 normally hearing adults. Validity and robustness of the technique w...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199910000-00001
更新日期:1999-10-01 00:00:00
abstract:INTRODUCTION:Cochlear implantation (CI) in subjects with unilateral profound sensorineural hearing loss was investigated. The authors of the present study demonstrated the binaural auditory outcomes in a 12- and 36-month prospective cohort outcome study. The present study aimed to do a long-term (LT) evaluation of the ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000359
更新日期:2017-01-01 00:00:00
abstract:OBJECTIVES:Vestibular reflexes have traditionally formed the cornerstone of vestibular evaluation, but perceptual tests have recently gained attention for use in research studies and potential clinical applications. However, the unknown reliability of perceptual thresholds limits their current importance. This is addre...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000859
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVES:At a minimum, unilateral hearing loss (UHL) impairs sound localization ability and understanding speech in noisy environments, particularly if the loss is severe to profound. Accompanying the numerous negative consequences of UHL is considerable unexplained individual variability in the magnitude of its effe...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000380
更新日期:2017-03-01 00:00:00
abstract:OBJECTIVES:The level-dependent growth of distortion product otoacoustic emissions (DPOAEs) provides an indirect metric of cochlear compressive nonlinearity. Recent evidence suggests that aging reduces nonlinear distortion emissions more than those associated with linear reflection. Therefore, in this study, we generate...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000319
更新日期:2016-09-01 00:00:00
abstract:OBJECTIVES:This study was conducted to examine improvements of cognitive abilities after cochlear implantation in deaf children. We also examined the psychosocial factors that predict good outcomes of cochlear implantation. DESIGN:A neuropsychological test battery was administered to 17 deaf children (mean age, 7 yr 2...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e318031541b
更新日期:2007-04-01 00:00:00
abstract:OBJECTIVES:To examine differences in family environment and associations between family environment and key speech, language, and cognitive outcomes in samples of children with normal hearing and deaf and hard-of-hearing (DHH) children who use hearing aids and cochlear implants. DESIGN:Thirty families of children with...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000811
更新日期:2020-07-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to examine the relationship between noise exposure history, type 1 diabetes mellitus (DM), and suprathreshold measures of auditory function. DESIGN:A cross-sectional study was conducted; 20 normal-hearing participants without type 1 DM were matched on age and sex to 20 normal-h...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000457
更新日期:2017-11-01 00:00:00
abstract:OBJECTIVE:To evaluate the additional perceptual benefit provided to children through the use of two cochlear implants in comparison to one after 6 to 13 mo experience with sequential bilateral implants. DESIGN:A second cochlear implant was received by 11 children. The principal selection criteria were being age 4 to 1...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e31806dc194
更新日期:2007-08-01 00:00:00
abstract::In a digitally controlled adaptive filter, ongoing detection and spectral analysis of quasi steady state noise are performed, and analog filter parameters are adjusted to provide greatest attenuation in frequency regions where noise energy is greatest. Attenuation introduced by the filter affects both speech and noise...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198802000-00012
更新日期:1988-02-01 00:00:00
abstract:OBJECTIVES:Early-deafened, late-implanted adolescents and adults constitute a unique group of cochlear implant (CI) users, showing a large variability in outcomes. The current systematic review aimed to determine which preimplantation factors are relevant in predicting postoperative outcomes in this patient group. DES...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000889
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVES:During the earlier years of the HIV/AIDS epidemic, initial reports described sensorineural hearing loss in up to 49% of individuals with HIV/AIDS. During those years, patients commonly progressed to advanced stages of HIV disease and frequently had neurological complications. However, the abnormalities on pu...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000064
更新日期:2014-11-01 00:00:00
abstract::Several cases illustrating potential pitfalls in neurotologic diagnosis from the viewpoint of the otologist are presented. The role of auditory brain stem response testing is specifically emphasized in cases with discordant audiologic and radiographic findings. Included are one case of a "false negative" ABR in a pati...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-198804000-00007
更新日期:1988-04-01 00:00:00
abstract::Pre- and postoperative audiologic findings are compared in a patient who underwent three cochlear implant surgeries: an initial single-channel device in a recently deafened ear with no residual hearing, followed by a multichannel device in a congenitally deafened ear with a severe to profound loss, and subsequent expl...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/00003446-199112000-00007
更新日期:1991-12-01 00:00:00
abstract:OBJECTIVES:The impact of social distancing on communication and psychosocial variables among individuals with hearing impairment during COVID-19 pandemic. It was our concern that patients who already found themselves socially isolated (Wie et al. 2010) as a result of their hearing loss would be perhaps more susceptible...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000991
更新日期:2020-12-22 00:00:00
abstract:OBJECTIVES:To assess discrimination of lexical stress pattern in infants with cochlear implant (CI) compared with infants with normal hearing (NH). While criteria for cochlear implantation have expanded to infants as young as 6 months, little is known regarding infants' processing of suprasegmental-prosodic cues which ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000243
更新日期:2016-03-01 00:00:00
abstract:OBJECTIVES:Binaural pitch fusion is the perceptual integration of stimuli that evoke different pitches between the ears into a single auditory image. Adults who use hearing aids (HAs) or cochlear implants (CIs) often experience abnormally broad binaural pitch fusion, such that sounds differing in pitch by as much as 3 ...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0000000000000874
更新日期:2020-11-01 00:00:00
abstract:OBJECTIVE:Early identification of permanent childhood hearing loss through universal newborn hearing screening is rapidly becoming a standard of care. However, it is well recognized that hearing screening must be embedded within a comprehensive system of rehabilitation and parent support services. This study was undert...
journal_title:Ear and hearing
pub_type: 杂志文章
doi:10.1097/AUD.0b013e318157676d
更新日期:2007-12-01 00:00:00