Superparamagnetic iron oxide (SPIO) labeling efficiency and subsequent MRI tracking of native cell populations pertinent to pulmonary heart valve tissue engineering studies.

Abstract:

:The intimal and medial linings of the pulmonary artery consist largely of vascular endothelial cells (VECs) and vascular smooth muscle cells (VSMCs), respectively. The migration of these cell types to a potential tissue-engineered pulmonary valve (TEPV) implant process is therefore of interest in understanding the valve remodeling process. Visualization and cell tracking by MRI, which employs hypointense contrast achievable through the use of superparamagnetic iron oxide (SPIO) microparticles to label cells, provides a method in which this can be studied. We investigated the SPIO labeling efficiency of human VECs and VSMCs, and used two- and three-dimensional gradient echo sequences to track the migration of these cells in agar gel constructs. Protamine sulfate (4.5 µg/mL) was used to enhance SPIO uptake and was found to have no influence on cell viability or proliferation. MRI experiments were initially performed using a 9.4-T scanner. The results demonstrated that the spatial positions of hypointense spots were relatively unchanged over 12 days. Subsequent MR experiments performed at 7 T demonstrated that three-dimensional imaging provided the best spatial resolution to assess cell fate. R(2)* maps were bright in SPIO cell-encapsulated gels in comparison with unlabeled counterparts. Signal voids were ruled out as hypointense regions owing to the smooth exponential decay of T(2)* in these voxels. As a next step, we intend to use the SPIO cell labeling and MR protocols established in this study to assess whether hemodynamic stresses will alter the vascular cell migratory patterns. These studies will shed light on the mechanisms of vascular remodeling after TEPV implantation.

journal_name

NMR Biomed

journal_title

NMR in biomedicine

authors

Ramaswamy S,Schornack PA,Smelko AG,Boronyak SM,Ivanova J,Mayer JE Jr,Sacks MS

doi

10.1002/nbm.1642

subject

Has Abstract

pub_date

2012-03-01 00:00:00

pages

410-7

issue

3

eissn

0952-3480

issn

1099-1492

journal_volume

25

pub_type

杂志文章,评审
  • Pattern recognition analysis of directional intravoxel incoherent motion MRI in ischemic rodent brains.

    abstract::This study aimed to demonstrate a reliable automatic segmentation method for independently separating reduced diffusion and decreased perfusion areas in ischemic stroke brains using constrained nonnegative matrix factorization (cNMF) pattern recognition in directional intravoxel incoherent motion MRI (IVIM-MRI). First...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4268

    authors: Jang M,Jin S,Kang M,Han S,Cho H

    更新日期:2020-05-01 00:00:00

  • Spectrally inhomogeneous BOLD contrast changes detected in rodent tumors with high spectral and spatial resolution MRI.

    abstract::MRI detects changes in blood-oxygenation-level dependent (BOLD) contrast in tumors caused by tumor oxygenating agents. These changes can be used to guide the design of improved tumor oxygenating treatments (TOXs). The conventional approach to detection of BOLD effects assumes that the water resonance is a single, homo...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.728

    authors: Al-Hallaq HA,Fan X,Zamora M,River JN,Moulder JE,Karczmar GS

    更新日期:2002-02-01 00:00:00

  • Robust hyperpolarized (13)C metabolic imaging with selective non-excitation of pyruvate (SNEP).

    abstract::In vivo metabolic imaging using hyperpolarized [1-(13)C]pyruvate provides localized biochemical information and is particularly useful in detecting early disease changes, as well as monitoring disease progression and treatment response. However, a major limitation of hyperpolarized magnetization is its unrecoverable d...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3346

    authors: Chen WC,Teo XQ,Lee MY,Radda GK,Lee P

    更新日期:2015-08-01 00:00:00

  • Assessing manganese efflux using SEA0400 and cardiac T1-mapping manganese-enhanced MRI in a murine model.

    abstract::The sodium-calcium exchanger (NCX) is one of the transporters contributing to the control of intracellular calcium (Ca(2+)) concentration by normally mediating net Ca(2+) efflux. However, the reverse mode of the NCX can cause intracellular Ca(2+) concentration overload, which exacerbates the myocardial tissue injury r...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1414

    authors: Waghorn B,Yang Y,Baba A,Matsuda T,Schumacher A,Yanasak N,Hu TC

    更新日期:2009-10-01 00:00:00

  • In vivo characterization of fatty acids in human adipose tissue using natural abundance 1H decoupled 13C MRS at 1.5 T: clinical applications to dietary therapy.

    abstract::Natural abundance proton-decoupled (13)C magnetic resonance spectroscopy was used to establish the in vivo lipid composition of normal adipose tissue and the corresponding effects of altered lipid diets. Experiments were performed on a standard 1.5 T clinical MR scanner using a double-tuned (1)H-(13)C coil. Peaks from...

    journal_title:NMR in biomedicine

    pub_type: 临床试验,杂志文章

    doi:10.1002/nbm.824

    authors: Hwang JH,Bluml S,Leaf A,Ross BD

    更新日期:2003-05-01 00:00:00

  • Cluster analysis of DCE-MRI data identifies regional tracer-kinetic changes after tumor treatment with high intensity focused ultrasound.

    abstract::Evaluation of high intensity focused ultrasound (HIFU) treatment with MRI is generally based on assessment of the non-perfused volume from contrast-enhanced T1-weighted images. However, the vascular status of tissue surrounding the non-perfused volume has not been extensively investigated with MRI. In this study, clus...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3406

    authors: Jacobs I,Hectors SJ,Schabel MC,Grüll H,Strijkers GJ,Nicolay K

    更新日期:2015-11-01 00:00:00

  • Structural and resting-state MRI detects regional brain differences in young and mid-age healthy APOE-e4 carriers compared with non-APOE-e4 carriers.

    abstract::The presence of the e4 allele of the apolipoprotein E (APOE) gene is the best-known genetic risk factor for Alzheimer's disease. In this study, we investigated the link between functional and behavioural differences and regional brain volume and cortical thickness differences in those who carry the e4 allele (e4+) and...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3502

    authors: Dowell NG,Evans SL,Tofts PS,King SL,Tabet N,Rusted JM

    更新日期:2016-05-01 00:00:00

  • A system for automated noise parameter measurements on MR preamplifiers and application to high B(0) fields.

    abstract::A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable power supply, noise source, tuning board, and desktop computer. The system uses the Y-factor method for noise figure calculation and allows calibrations to correc...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3138

    authors: Lagore RL,Roberts BR,Possanzini C,Saylor C,Fallone BG,De Zanche N

    更新日期:2014-08-01 00:00:00

  • Differences in metabolism of 5-fluorouracil and 5-fluorouridine and regulation by glucosamine in human colon cancer multicell tumor spheroids.

    abstract::Glucosamine (GlcN) modulates fluoropyrimidine metabolism and enhances cytotoxicity of 5-fluorouridine (FUrd), but not of 5-fluorouracil (FUra), in human tumor models. To elucidate the underlying metabolic differences between FUra and FUrd, by the use of 19F and 31P NMR spectroscopy we studied these drugs in multicell ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199905)12:3<157::aid-nbm55

    authors: Chen TB,Bajzer Z,Macura S,Vuk-Pavlovic S

    更新日期:1999-05-01 00:00:00

  • Analysis of the changes in the 1H NMR spectral pattern of perchloric acid extracts of C6 cells with growth.

    abstract::The aim of this work was to identify spectral markers of cell proliferation that could be of use in clinical MRS. Cultured C6 ATCC rat glioma cells were used as models for this purpose and metabolites were extracted with perchloric acid at three different growth curve stages: log, confluence and post-confluence. 1D an...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1024

    authors: Valverde D,Quintero MR,Candiota AP,Badiella L,Cabañas ME,Arús C

    更新日期:2006-04-01 00:00:00

  • Myocardial T1 mapping using SMART1 Map and MOLLI mapping in asymptomatic patients with recent extracardiac sarcoidosis.

    abstract:INTRODUCTION:Sarcoidosis is a systemic granulomatous disease affecting in particular the respiratory tract. Cardiac magnetic resonance (CMR), including a measurement of T1 relaxation time, could potentially detect early stadia of sarcoidosis of the heart. The study aims to assess T1 mapping in the detection of early ca...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4388

    authors: Panovský R,Doubková M,Holeček T,Máchal J,Feitová V,Masárová L,Opatřil L,Mojica-Pisciotti ML,Kincl V

    更新日期:2020-11-01 00:00:00

  • Pre-polarized saline: an in vivo feasibility study of a potential contrast agent.

    abstract::The potential for using pre-polarized liquids as contrast agents in vivo is investigated and the feasibility of the method demonstrated. In this study we show the enhancement obtained following intravenous delivery of pre-polarized saline into the antecubital vein of a volunteer. This form of contrast agent provides s...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199910)12:6<381::aid-nbm57

    authors: Young IR,deSouza NM,Hall AS,Williams AD,Hajnal JV,Coutts GA

    更新日期:1999-10-01 00:00:00

  • Trading off SNR and resolution in MR images.

    abstract::With a fixed time to acquire a magnetic resonance (MR) image, time can be spent to acquire better spatial resolution with decrease in signal-to-noise ratio (SNR) or decreased resolution with increase in SNR. This resolution/SNR tradeoff at fixed time has been investigated by a visual rater study using images of ex viv...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1359

    authors: Kale SC,Chen XJ,Henkelman RM

    更新日期:2009-06-01 00:00:00

  • Mapping of prostate cancer by 1H MRSI.

    abstract::In many studies, it has been demonstrated that (1)H MRSI of the human prostate has great potential to aid prostate cancer management, e.g. in the detection and localisation of cancer foci in the prostate or in the assessment of its aggressiveness. It is particularly powerful in combination with T2 -weighted MRI. Never...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.2973

    authors: Kobus T,Wright AJ,Scheenen TW,Heerschap A

    更新日期:2014-01-01 00:00:00

  • Altered functional brain networks in Prader-Willi syndrome.

    abstract::Prader-Willi syndrome (PWS) is a genetic imprinting disorder characterized mainly by hyperphagia and early childhood obesity. Previous functional neuroimaging studies used visual stimuli to examine abnormal activities in the eating-related neural circuitry of patients with PWS. It was found that patients with PWS exhi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2900

    authors: Zhang Y,Zhao H,Qiu S,Tian J,Wen X,Miller JL,von Deneen KM,Zhou Z,Gold MS,Liu Y

    更新日期:2013-06-01 00:00:00

  • Optimization methods for magnetic resonance imaging gradient waveform design.

    abstract::The development and implementation of novel MRI pulse sequences remains challenging and laborious. Gradient waveforms are typically designed using a combination of analytical and ad hoc methods to construct each gradient waveform axis independently. This strategy makes coding the pulse sequence complicated, in additio...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4308

    authors: Middione MJ,Loecher M,Moulin K,Ennis DB

    更新日期:2020-12-01 00:00:00

  • 31P NMR relaxation of cortical bone mineral at multiple magnetic field strengths and levels of demineralization.

    abstract::Recent work has shown that solid-state (1) H and (31) P MRI can provide detailed insight into bone matrix and mineral properties, thereby potentially enabling differentiation of osteoporosis from osteomalacia. However, (31) P MRI of bone mineral is hampered by unfavorable relaxation properties. Hence, accurate knowled...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2930

    authors: Seifert AC,Wright AC,Wehrli SL,Ong HH,Li C,Wehrli FW

    更新日期:2013-09-01 00:00:00

  • The impact of edema and fiber crossing on diffusion MRI metrics assessed in an ex vivo nerve phantom: Multi-tensor model vs. diffusion orientation distribution function.

    abstract::Diffusion tensor imaging (DTI) has been employed for over 2 decades to noninvasively quantify central nervous system diseases/injuries. However, DTI is an inadequate simplification of diffusion modeling in the presence of coexisting inflammation, edema and crossing nerve fibers. We employed a tissue phantom using fixe...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4414

    authors: Ye Z,Gary SE,Sun P,Mustafi SM,Glenn GR,Yeh FC,Merisaari H,Song C,Yang R,Huang GS,Kao HW,Lin CY,Wu YC,Jensen JH,Song SK

    更新日期:2021-01-01 00:00:00

  • Lung ventilation volumetry with same-breath acquisition of hyperpolarized gas and proton MRI.

    abstract::The purpose of this work was to assess the reproducibility of percentage of ventilated lung volume (PV) measured from hyperpolarized (HP) (3)He and (1)H anatomical images acquired in the same breath-hold when compared with PV measured from (3)He and (1)H images from separate breath-holds. Volumetric (3)He ventilation ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3187

    authors: Horn FC,Tahir BA,Stewart NJ,Collier GJ,Norquay G,Leung G,Ireland RH,Parra-Robles J,Marshall H,Wild JM

    更新日期:2014-12-01 00:00:00

  • Q-ball imaging with PROPELLER EPI acquisition.

    abstract::Q-ball imaging (QBI) is an imaging technique that is capable of resolving intravoxel fiber crossings; however, the signal readout based on echo-planar imaging (EPI) introduces geometric distortions in the presence of susceptibility gradients. This study proposes an imaging technique that reduces susceptibility distort...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3009

    authors: Chou MC,Huang TY,Chung HW,Hsieh TJ,Chang HC,Chen CY

    更新日期:2013-12-01 00:00:00

  • Probing the cardiac malate-aspartate shuttle non-invasively using hyperpolarized [1,2-13 C2 ]pyruvate.

    abstract::Previous studies have demonstrated that using hyperpolarized [2-13 C]pyruvate as a contrast agent can reveal 13 C signals from metabolites associated with the tricarboxylic acid (TCA) cycle. However, the metabolites detectable from TCA cycle-mediated oxidation of [2-13 C]pyruvate are the result of several metabolic st...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3845

    authors: Chen AP,Lau AZ,Gu YP,Schroeder MA,Barry J,Cunningham CH

    更新日期:2018-01-01 00:00:00

  • Leakage of metabolites from tissue biopsies can result in large errors in quantitation by MRS.

    abstract::The leakage of metabolites from frozen and thawed tissue biopsies was measured semi-quantitatively by high-field (8.5 T) proton MRS. Human prostate and rat brain tissue specimens, frozen within 1 min of collection, lost significant and variable amounts of diagnostic metabolites immediately upon thawing. For prostate t...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.815

    authors: Bourne R,Dzendrowskyj T,Mountford C

    更新日期:2003-04-01 00:00:00

  • 1H NMR spectroscopy as a tool to evaluate key metabolic functions of primary porcine hepatocytes after cryopreservation.

    abstract::Proton NMR spectroscopy of biological fluids has produced interesting results lately. We used the technique to investigate the effects of cryopreservation on primary porcine hepatocytes as successful cryopreservation of primary porcine hepatocytes is of importance to the development of bioartificial liver support syst...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.765

    authors: Dabos KJ,Parkinson JA,Hewage C,Nelson LJ,Sadler IH,Hayes PC,Plevris JN

    更新日期:2002-05-01 00:00:00

  • Two-dimensional NMR spectroscopy of urinary glycosaminoglycans from patients with different mucopolysaccharidoses.

    abstract::Patients with different types of mucopolysaccharidoses (MPS) lack specific lysosomal enzymes, which leads to tissue accumulation and urinary excretion of glycosaminoglycans (GAGs). Since little is known about the molecular composition of the excreted GAG fragments, we used two-dimensional [1H,13C]-correlation nuclear ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.833

    authors: Hochuli M,Wüthrich K,Steinmann B

    更新日期:2003-06-01 00:00:00

  • Influence of measured and simulated basis sets on metabolite concentration estimates.

    abstract::By quantification of brain metabolites, localized brain proton MRS can non-invasively provide biochemical information from distinct regions of the brain. Quantification of short-TE signals is usually based on a metabolite basis set. The basis set can be obtained by two approaches: (1) by measuring the signals of metab...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1234

    authors: Cudalbu C,Cavassila S,Rabeson H,van Ormondt D,Graveron-Demilly D

    更新日期:2008-07-01 00:00:00

  • Accelerated high-frame-rate mouse heart cine-MRI using compressed sensing reconstruction.

    abstract::We introduce a new protocol to obtain very high-frame-rate cinematographic (Cine) MRI movies of the beating mouse heart within a reasonable measurement time. The method is based on a self-gated accelerated fast low-angle shot (FLASH) acquisition and compressed sensing reconstruction. Key to our approach is that we exp...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2883

    authors: Motaal AG,Coolen BF,Abdurrachim D,Castro RM,Prompers JJ,Florack LM,Nicolay K,Strijkers GJ

    更新日期:2013-04-01 00:00:00

  • Studies of metabolic compartmentation and glucose transport using in vivo MRS.

    abstract::Organs consist of several types of cells with specialized functions. This cellular localization of function is often referred to as compartmentation. Due to the intrinsic low sensitivity of MR methods it is generally not possible in vivo to obtain images or spectra of single cells. Instead the MRS signal is the sum of...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.692

    authors: Rothman DL

    更新日期:2001-04-01 00:00:00

  • Multi-component apparent diffusion coefficients in human brain.

    abstract::The signal decay with increasing b-factor at fixed echo time from brain tissue in vivo has been measured using a line scan Stejskal-Tanner spin echo diffusion approach in eight healthy adult volunteers. The use of a 175 ms echo time and maximum gradient strengths of 10 mT/m allowed 64 b-factors to be sampled, ranging ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199902)12:1<51::aid-nbm546

    authors: Mulkern RV,Gudbjartsson H,Westin CF,Zengingonul HP,Gartner W,Guttmann CR,Robertson RL,Kyriakos W,Schwartz R,Holtzman D,Jolesz FA,Maier SE

    更新日期:1999-02-01 00:00:00

  • Image-based tissue engineering of a total intervertebral disc implant for restoration of function to the rat lumbar spine.

    abstract::Nonbiological total disc replacement is currently being used for the treatment of intervertebral disc (IVD) disease and injury, but these implants are prone to mechanical wear, tear and possible dislodgement. Recently, tissue-engineered total disc replacement (TE-TDR) has been investigated as a possible alternative to...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1651

    authors: Bowles RD,Gebhard HH,Dyke JP,Ballon DJ,Tomasino A,Cunningham ME,Härtl R,Bonassar LJ

    更新日期:2012-03-01 00:00:00

  • Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T.

    abstract::The increased magnetic susceptibility effects at higher magnetic fields increase the demands for shimming of the B0 field for in vivo MRI and MRS. Both static and dynamic techniques have been developed to compensate for susceptibility-induced field inhomogeneities. In this study, we investigate the impact of and need ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3096

    authors: Boer VO,Luttje MP,Luijten PR,Klomp DW

    更新日期:2014-06-01 00:00:00