Repeatability and reproducibility of anterior chamber volume measurements using 3-dimensional corneal and anterior segment optical coherence tomography.

Abstract:

PURPOSE:To evaluate the repeatability and reproducibility of anterior chamber volume (ACV) measurements using swept-source 3-dimensional corneal and anterior segment optical coherence tomography (CAS-OCT) and dual Scheimpflug imaging. SETTING:Department of Ophthalmology, Institute of Clinical Medicine, University of Tsukuba, Ibaraki, Japan. DESIGN:Nonrandomized clinical trial. METHODS:Measurements were taken in normal eyes (subject group) and in eyes with primary angle closure (PAC) (patient group). In the subject group, the entire ACV and the central 8.0 mm diameter ACV were measured using CAS-OCT and dual Scheimpflug imaging. In the patient group, the entire ACV and 8.0 mm ACV were measured using CAS-OCT. The coefficient of variation and intraclass correlation coefficient (ICC) were calculated to evaluate repeatability and reproducibility, and the correlation between the 2 devices was assessed. RESULTS:In the subject group, the mean 8.0 mm ACV was 110.14 mm(3) ± 12.57 (SD) using CAS-OCT and 114.51 ± 14.69 mm(3) using Scheimpflug imaging; there was a significant linear correlation (r = 0.878, P < .0001). The mean entire ACV on CAS-OCT was 165.15 ± 29.29 mm(3). The ICCs of the 8.0 mm and entire ACV measurements were greater than 0.94. The coefficients of repeatability and reproducibility of the 8.0 mm ACV and entire ACV measurements were less than 5%. In the patient group, the 8.0 mm and entire ACV measurements showed good reproducibility and repeatability. CONCLUSIONS:The CAS-OCT method allowed noninvasive measurement of the entire ACV with sufficient repeatability and reproducibility. The 8.0 mm ACV measurements with CAS-OCT and Scheimpflug imaging were comparable.

authors

Fukuda S,Kawana K,Yasuno Y,Oshika T

doi

10.1016/j.jcrs.2010.08.053

subject

Has Abstract

pub_date

2011-03-01 00:00:00

pages

461-8

issue

3

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(10)01769-4

journal_volume

37

pub_type

临床试验,杂志文章
  • Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

    abstract::Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and pot...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.05.019

    authors: Hoffman RS,Fine IH,Packer M

    更新日期:2009-10-01 00:00:00

  • Light scattering, straylight, and optical quality in hydrophobic acrylic intraocular lenses with subsurface nanoglistenings.

    abstract:PURPOSE:To evaluate forward light scattering and straylight in single-piece hydrophobic acrylic intraocular lenses (IOLs) (Acrysof) removed from cadaver eyes and design- and power-matched controls, as well as the effect of subsurface nanoglistenings on other optical quality and performance indicators. SETTING:John A. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2015.07.043

    authors: Werner L,Stover JC,Schwiegerling J,Das KK

    更新日期:2016-01-01 00:00:00

  • Long-term results of myopic epikeratoplasty.

    abstract::Twenty-three eyes of 20 patients who had had myopic epikeratoplasty were evaluated and the mean 21-month postoperative results (range: 12 to 47 months) tabulated. Average preoperative myopia was -16.7 diopters (D) spherical equivalent (range: -10 to -33 D), and average postoperative refractive correction was 13 D. Of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80305-7

    authors: Kim WJ,Lee JH

    更新日期:1993-05-01 00:00:00

  • Ab externo scleral suture loop fixation for posterior chamber intraocular lens decentration: clinical results.

    abstract:PURPOSE:To evaluate the efficacy and safety of an ab externo suture retrieval and scleral fixation technique in the treatment of subluxated posterior chamber intraocular lenses (PC IOLs). SETTING:Academic tertiary care centers. METHODS:Surgical databases from 2 surgeons were reviewed for consecutive cases from March ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.06.050

    authors: Chan CC,Crandall AS,Ahmed II

    更新日期:2006-01-01 00:00:00

  • Continuous curvilinear capsulorhexis with use of an endoscope.

    abstract::We describe a technique for creating a continuous curvilinear capsulorhexis (CCC) using an endoscope. Three 2.0 mm limbal incisions 120 degrees apart were made in 4 cadaver eyes. The anterior capsule was stained with trypan blue 0.1% (Vision Blue). Under endoscopic visualization, a CCC was attempted in each of the 4 g...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.09.051

    authors: Moore JE,Herath GD,Sharma A

    更新日期:2004-05-01 00:00:00

  • Diurnal variations in keratometry and refraction with intracorneal ring segments.

    abstract:PURPOSE:To study refraction variations during the day in eyes with intrastromal corneal ring segments (ICRS) to correct low myopia. SETTING:Monticelli Clinic, Marseille, France. METHODS:Thirteen eyes with ICRS were included in the study; the ICRS was explanted from 3 eyes because of undercorrection. The minimum follo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00129-7

    authors: Baïkoff G,Maia N,Poulhalec D,Fontaine A,Giusiano B

    更新日期:1999-08-01 00:00:00

  • Effect of partial and full correction of corneal spherical aberration on visual acuity and contrast sensitivity.

    abstract::A 60-year-old white man had cataract surgery with an AcrySof IQ intraocular lens (IOL) implanted in the right eye and a Tecnis IOL implanted in the left eye. The ocular spherical aberration (SA) target for a 6.0 mm pupil was +0.10 microm for the right eye and 0 microm for the left eye. After surgery, the ocular SA in ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.12.041

    authors: Ferrer-Blasco T

    更新日期:2009-05-01 00:00:00

  • Surgical options for retreatment after small-incision lenticule extraction: Advantages and disadvantages.

    abstract::Since the inception of small-incision lenticule extraction (SMILE), many surgeons have speculated the lack of an adequate and standard retreatment procedure will impede its popularity. However, more than 1 million patients worldwide have had this surgery, with visual outcomes nearly equivalent to current laser in situ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,评审

    doi:10.1016/j.jcrs.2018.07.047

    authors: Moshirfar M,Shah TJ,Masud M,Linn SH,Ronquillo Y,Hoopes PC Sr

    更新日期:2018-11-01 00:00:00

  • Endothelial keratoplasty for bullous keratopathy in eyes with an anterior chamber intraocular lens.

    abstract:PURPOSE:To describe how to approach eyes with phakic or pseudophakic bullous keratopathy that have an anterior chamber intraocular lens (AC IOL) using thin Descemet-stripping endothelial keratoplasty (thin-DSEK) or Descemet membrane endothelial keratoplasty (DMEK) with or without AC IOL removal. SETTING:Tertiary refer...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.05.045

    authors: Liarakos VS,Ham L,Dapena I,Tong CM,Quilendrino R,Yeh RY,Melles GR

    更新日期:2013-12-01 00:00:00

  • Pop-and-chop nucleofractis.

    abstract::Horizontal chopping is effective for endocapsular nucleofractis. We describe pop and chop, a variant of chopping that enables an easy first crack and initial segment removal. It involves partial extracapsular prolapse of the nucleus prior to the initial chop. It is particularly useful when hydrodissection results in p...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00339-0

    authors: Pandit RT,Oetting TA

    更新日期:2003-11-01 00:00:00

  • European clinical evaluation: use of Intacs for the treatment of keratoconus.

    abstract:PURPOSE:To evaluate the safety and efficacy of Intacs inserts in keratoconic eyes to alter corneal shape and refractive power and stabilize the progression of corneal ectasia. SETTING:Service d'Ophtalmologie, Bordeaux, France. METHODS:In this prospective study, 57 eyes with clear central corneas that were diagnosed w...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2006.01.064

    authors: Colin J

    更新日期:2006-05-01 00:00:00

  • Effect of high vacuum and aspiration on phacoemulsification efficiency and chatter using a transversal ultrasound machine.

    abstract:PURPOSE:To examine the role of high vacuum and aspiration settings on efficiency using a transversal ultrasound (US) machine. SETTING:John A. Moran Eye Center Laboratory, University of Utah, Salt Lake City, Utah, USA. DESIGN:Experimental study. METHODS:Porcine lens nuclei were incubated in formalin for 2 hours and t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2018.05.031

    authors: Kabbara S,Heczko JB,Bernhisel AA,Barlow WR,Zaugg B,Pettey JH,Olson RJ

    更新日期:2018-11-01 00:00:00

  • Optical resolution of foldable intraocular lenses.

    abstract::Recently manufactured intraocular lenses (IOLs) (STAAR AA 4203 made of silicone and IOGEL PC-12 made of polyHEMA) were tested before and after implantation simulation for axial optical resolution (model eye), for optical surface quality (photokeratoscope), and for surface microtrauma (scanning electron microscopy). At...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80733-x

    authors: Kulnig W,Skorpik C

    更新日期:1990-03-01 00:00:00

  • Intrascleral four-flanged technique for in-the-bag IOL subluxation.

    abstract:PURPOSE:To present a series of cases in which the four-flanged technique was used in the management of in-the-bag intraocular lens (IOL) subluxation. SETTING:Shamir medical center, Israel. DESIGN:Retrospective cohort analysis. METHODS:Included were consecutive cases with secondary IOL subluxation that underwent scle...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000474

    authors: Mahler OS,Biron R,Hecht I,Pras E,Einan-Lifshitz A

    更新日期:2020-11-02 00:00:00

  • Effect of intraocular lens asphericity on vertical coma aberration.

    abstract:PURPOSE:To analyze the effect of asphericity of intraocular lenses (IOLs) on vertical coma aberration after implantation of spherical, spherically neutral, and aspheric IOLs. SETTING:Department of Ophthalmology, St. Thomas' Hospital, London, United Kingdom. METHOD:This observational study recruited patients from prev...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.08.024

    authors: Nanavaty MA,Spalton DJ,Marshall J

    更新日期:2010-02-01 00:00:00

  • Comparison of function and fixation of small incision circular and oval poly(methyl methacrylate) intraocular lenses.

    abstract::A prospective study of function and fixation was done on 40 patients implanted with small incision poly(methyl methacrylate), single piece, biconvex intraocular lenses after in situ phacoemulsification cataract extraction via a continuous curvilinear capsulorhexis. A 5.0 mm circular optic (Pharmacia 740 P), 14 mm leng...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80919-4

    authors: Davis PL

    更新日期:1992-03-01 00:00:00

  • Comparison of the Storz bifocal zonal and the 3M diffractive multifocal intraocular lenses.

    abstract::Visual acuity and contrast sensitivity after cataract surgery were evaluated in best-case eyes that received a Storz bifocal zonal intraocular lens (IOL) or a 3M diffractive multifocal IOL. A group of eyes with a monofocal IOL was used as a control. Postoperatively, all eyes had a best corrected visual acuity of 20/40...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80536-6

    authors: Boesten IE,Beekhuis WH,Hassmann E,Pameyer JH,Baarsma GS

    更新日期:1995-07-01 00:00:00

  • Postoperative intraocular pressure rises: a comparison of Healon, Amvisc, and Viscoat.

    abstract::A prospective randomized study was performed involving 200 patients divided into four groups: (1) Healon aspirated, (2) Amvisc aspirated, (3) Viscoat aspirated, and (4) Viscoat not aspirated. Postoperative intraocular pressures were measured at 4, 8, and 24 hours, two to three days, and one month. Significant differen...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1016/s0886-3350(89)80060-4

    authors: Fry LL

    更新日期:1989-07-01 00:00:00

  • Simplified anesthesia technique for scleral tunnel phacoemulsification.

    abstract::A simplified anesthesia technique for sutureless scleral tunnel, small incision, one-port phacoemulsification is described. Step 1: Mild intravenous sedation is achieved with 1 mg of midazolam and 10 mg of propofol. Step 2: A tetracaine- or preservative-free-lidocaine-soaked Weck cell sponge is applied to the superior...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80342-8

    authors: John T

    更新日期:1998-12-01 00:00:00

  • Gravitational pseudoaccommodation in patients with aphakic iris-claw intraocular lenses.

    abstract:PURPOSE:To assess whether iris-claw intraocular lenses (IOLs) undergo gravitation-dependent changes in position and refraction. SETTING:Tertiary referral center, Bern, Switzerland. DESIGN:Observational case study. METHODS:Patients with a history of pars plana vitrectomy and IOL exchange with implantation of an aphak...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2016.07.033

    authors: Lincke JB,Miller M,Ebneter A,Zinkernagel MS

    更新日期:2016-10-01 00:00:00

  • Capsular peeling in anterior capsule contraction syndrome: surgical approach and histopathological aspects.

    abstract::We present 4 cases of anterior capsule contraction syndrome in which progressive shrinkage of the anterior capsulorhexis developed after uneventful phacoemulsification. Three eyes were pseudophakic, and 1 eye remained aphakic. The newly formed membrane was surgically peeled from the anterior capsule, restoring the cap...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.08.034

    authors: Reyntjens B,Tassignon MJ,Van Marck E

    更新日期:2004-04-01 00:00:00

  • Scheimpflug measurement of intraocular lens position after piggyback implantation of foldable intraocular lenses in eyes with high hyperopia.

    abstract:PURPOSE:To investigate the position of 3-piece foldable intraocular lenses (IOLs) after piggyback implantation for high hyperopia. SETTING:University Eye Hospital, Johann Wolfgang Goethe University, Frankfurt am Main, Germany. METHODS:Eight eyes of 5 highly hyperopic patients had phacoemulsification and implantation ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.08.033

    authors: Baumeister M,Kohnen T

    更新日期:2006-12-01 00:00:00

  • Photorefractive keratectomy after radial keratotomy.

    abstract::We report the results of a prospective study that evaluated the efficacy, predictability, and safety of excimer laser photorefractive keratectomy (PRK) to correct residual myopia after radial keratotomy (RK). Using a 193 nm excimer laser, we performed PRK on ten undercorrected myopic eyes that had previous RK surgery....

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80224-6

    authors: Meza J,Perez-Santonja JJ,Moreno E,Zato MA

    更新日期:1994-09-01 00:00:00

  • Herpetic keratitis with iritis after corneal crosslinking with riboflavin and ultraviolet A for keratoconus.

    abstract::A 21-year-old woman had crosslinking for keratoconus in the right eye; the left eye was scheduled for penetrating keratoplasty. Five days postoperatively, she presented with geographic epithelial keratitis and iritis. Analysis of tear samples by polymerase chain reaction confirmed the diagnosis. The patient was treate...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.06.036

    authors: Kymionis GD,Portaliou DM,Bouzoukis DI,Suh LH,Pallikaris AI,Markomanolakis M,Yoo SH

    更新日期:2007-11-01 00:00:00

  • Model of anesthesia care that combines anesthesiologists and registered nurses during cataract surgery.

    abstract:PURPOSE:To determine the safety and practicality of a combined anesthesiologist and registered nurse model of anesthesia care in cataract surgery. SETTING:Mayo Clinic, Rochester, Minnesota, USA. DESIGN:Case series. METHODS:This retrospective review comprised consecutive patients having phacoemulsification cataract s...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.09.021

    authors: Erie AJ,McHugh R,Warner M,Erie JC

    更新日期:2011-03-01 00:00:00

  • Capsular bag shrinkage after implantation of a capsular bending or capsular tension ring.

    abstract:PURPOSE:To evaluate the influence of a capsular bending ring (CBR) or tension ring (CTR) on capsular bag shrinkage. SETTING:Department of Ophthalmology, Johannes Gutenberg-University, and Department of Medical Biometry, Epidemiology and Informatics, University of Mainz, Mainz, Germany. METHODS:In 92 eyes of 92 patien...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,随机对照试验

    doi:10.1016/j.jcrs.2005.06.046

    authors: Kurz S,Krummenauer F,Hacker P,Pfeiffer N,Dick HB

    更新日期:2005-10-01 00:00:00

  • Visual acuity after penetrating keratoplasty for pseudophakic and aphakic bullous keratopathy.

    abstract:PURPOSE:To identify prognostic factors that determine the visual acuity after penetrating keratoplasty (PKP) for bullous keratopathy secondary to cataract surgery. SETTING:Department of Ophthalmology, University Hospital Antwerp, Antwerp, Belgium. METHODS:Twenty-six patients who had PKP for bullous keratopathy were e...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01742-x

    authors: Schraepen P,Koppen C,Tassignon MJ

    更新日期:2003-03-01 00:00:00

  • Outside-in transscleral fixation for ciliary sulcus intraocular lens placement.

    abstract::We describe a new technique of transscleral intraocular lens fixation in the absence of adequate posterior capsular support. This technique of suture placement within the ciliary sulcus employs routinely used instruments, requires minimum manipulation, and has good visual outcome and negligible complications. We perfo...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(13)80053-3

    authors: Basti S,Tejaswi PC,Singh SK,Sekhar GC

    更新日期:1994-01-01 00:00:00

  • Meridional differences in internal dimensions of the anterior segment in human eyes evaluated with 2 imaging systems.

    abstract:PURPOSE:To evaluate meridional differences in angle-to-angle (A-A) and sulcus-to-sulcus (S-S) dimensions in human eyes using very high frequency ultrasound (VHF US) and anterior segment optical coherence tomography (AS-OCT). SETTING:John A. Moran Eye Center, University of Utah, USA; Berlin Eye Research Institute, Germ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.03.033

    authors: Werner L,Lovisolo C,Chew J,Tetz M,Müller M

    更新日期:2008-07-01 00:00:00

  • Repeatability, reproducibility, and agreement of corneal power measurements obtained with a new corneal topographer.

    abstract:PURPOSE:To study the repeatability and reproducibility of corneal power measurements obtained with a new corneal topographer (Keratograph 4) and assess their agreement with those obtained by a rotating Scheimpflug camera (Pentacam HR) and an automated keratometer (IOLMaster). SETTING:Eye Hospital, Wenzhou Medical Univ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2013.04.029

    authors: Mao X,Savini G,Zhuo Z,Feng Y,Zhang J,Wang Q,Chen H,Huang J

    更新日期:2013-10-01 00:00:00