Stiffness of knee-spanning external fixation systems for traumatic knee dislocations: a biomechanical study.

Abstract:

OBJECTIVE:The purpose of this study was to compare the relative stiffness of four common external fixation (XF) configurations used to span and stabilize the knee after knee dislocation. METHODS:Synthetic composite femora and tibiae connected with cords were used to simulate a knee. Four configurations of external fixation were tested: anterior femoral pins with monotube (XF1), anterolateral femoral pins with monotube (XF2), anterolateral femoral pins with two connecting rods (XF3), and hinged ring fixator (XF4). Six specimens of each configuration were loaded nondestructively in varus/valgus, anterior-to-posterior shear, flexion/extension, axial compression, internal/external torsion, and failure in varus. RESULTS:XF2 was stiffer than XF1 in varus, valgus, and axial loading (P < 0.01) demonstrating that anterolateral pins provided greater stiffness than anterior femoral pins. XF3 was stiffer than XF2 in varus, valgus, and anterior-to-posterior shear (P < 0.002), indicating that two connecting rods provided greater stiffness than the monotube. XF4 was similar to the other configurations in anterior-to-posterior shear and torsion, indicating the hinged frame provided adequate stability. The average load to failure in varus mode was 250 N-m, which was far beyond the nondestructive loading of all specimens. There was no statistical difference between the different constructs in load to failure. CONCLUSIONS:The stiffest construct for external fixation of a knee dislocation was achieved when pins were placed anterior lateral on the femur and two connecting rods were used. A stiffer construct may provide a better clinical outcome and we therefore recommend this frame configuration.

journal_name

J Orthop Trauma

authors

Mercer D,Firoozbakhsh K,Prevost M,Mulkey P,DeCoster TA,Schenck R

doi

10.1097/BOT.0b013e3181e3cd4b

subject

Has Abstract

pub_date

2010-11-01 00:00:00

pages

693-6

issue

11

eissn

0890-5339

issn

1531-2291

journal_volume

24

pub_type

杂志文章
  • The reliability of measurement of tissue pressure in compartment syndrome.

    abstract:BACKGROUND:Although there is general agreement as to the pathophysiology and treatment of compartment syndrome and the importance of intramuscular pressure measurements, there are many methods described to obtain these measurements. Variations in experimental measurements using current electronic monitoring, needle, an...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e31822908cf

    authors: Hammerberg EM,Whitesides TE Jr,Seiler JG 3rd

    更新日期:2012-01-01 00:00:00

  • Slow rebound of cancellous bone after mainly steroid-induced osteoporosis in ovariectomized sheep.

    abstract:OBJECTIVES:A sheep model of osteoporosis suitable for implant testing for osteoporotic fractures was evaluated with regard to normalization of hormonal status and possible rebound of bone mineral density subsequent to the termination of steroid application. DESIGN:Osteoporosis was induced in 10 aged, female white alpi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200501000-00005

    authors: Goldhahn J,Jenet A,Schneider E,Lill CA

    更新日期:2005-01-01 00:00:00

  • Getting organized in your job.

    abstract::The benefits of being organized when starting one's career are countless and worth the time and effort in developing an effective and efficient practice. Established protocols, good habits, and methodical communication that include all members of the team will help create a system that keeps all components of one's pr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a52344

    authors: Siegel J

    更新日期:2013-10-01 00:00:00

  • Does malrotation following MIPO treatment of distal tibia metaphyseal fractures effect the functional results of the ankle and knee joints?

    abstract:OBJECTIVES:To investigate whether rotational malalignment of tibia, after fracture management with minimally invasive plate osteosynthesis technique (MIPO), leads to impaired results in knee and ankle joint functional scores. DESIGN:Prospectively collected data was retrospectively analyzed for this study. SETTING:Lev...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000002053

    authors: Çepni Ş,Yaman F,Veizi E,Fırat A,ÇayAssoc N,Tecimel O

    更新日期:2020-12-31 00:00:00

  • The PFNA proximal femur nail in treatment of unstable proximal femur fractures--3 cases of postoperative perforation of the helical blade into the hip joint.

    abstract::The proximal femur nail antirotation represents a new generation of intramedullary nailing devices for fixation of stable and unstable trochanteric fractures of the proximal femur. We report 3 cases of postoperative perforation of the helical blade through the femoral head into the hip joint without any signs of rotat...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181893b1b

    authors: Brunner A,Jöckel JA,Babst R

    更新日期:2008-11-01 00:00:00

  • A prospective clinical study of proximal humerus fractures treated with a locking proximal humerus plate.

    abstract:OBJECTIVES:The purpose of this prospective study was to evaluate the safety, efficacy, and functional outcome of the locked proximal humerus plate (LPHP) to treat proximal humerus fractures. DESIGN:Prospective clinical trial. SETTING:University orthopedic center. PATIENTS:Over a 25-month period, 64 consecutive patie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 临床试验,杂志文章

    doi:10.1097/BOT.0b013e3181d2d04c

    authors: Yang H,Li Z,Zhou F,Wang D,Zhong B

    更新日期:2011-01-01 00:00:00

  • Ipsilateral combination Monteggia and Galeazzi injuries in an adult patient: a case report.

    abstract::Monteggia fractures represent approximately 1 to 2 percent of forearm fractures, whereas Galeazzi fractures represent 3 to 6 percent. The combination of these injuries in the same extremity is an exceedingly rare occurrence. We report a case of ipsilateral combination Monteggia and Galeazzi fractures in an adult patie...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200202000-00011

    authors: Clare DJ,Corley FG,Wirth MA

    更新日期:2002-02-01 00:00:00

  • Economic Impact of Nonmodifiable Risk Factors in Orthopaedic Fracture Care: Is Bundled Payment Feasible?

    abstract:OBJECTIVES:To determine whether bundled payments are feasible in the orthopaedic fracture setting, and the potential economic implications of this reimbursement structure. DESIGN:Prospective. SETTING:Multicenter. PATIENTS/PARTICIPANTS:Between 2004 and 2014, a total of 23,643 operatively treated patients with fractur...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000742

    authors: Mahure SA,Hutzler L,Yoon RS,Bosco JA

    更新日期:2017-03-01 00:00:00

  • Ninety-Five Degree Angled Blade Plate Fixation of High-Energy Unstable Proximal Femur Fractures Results in High Rates of Union and Minimal Complications.

    abstract:OBJECTIVES:To describe the surgical technique and clinical outcomes of high-energy proximal femur fractures treated with a 95-degree angled blade plate. DESIGN:Retrospective case series. SETTING:Single academic Level I trauma center. PATIENT/PARTICIPANTS:Forty-five consecutive patients from March 2012 to April 2017 ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001505

    authors: Berkes MB,Schottel PC,Weldon M,Hansen DH,Achor TS

    更新日期:2019-07-01 00:00:00

  • In vitro toxicity and activity of Dakin's solution, mafenide acetate, and amphotericin B on filamentous fungi and human cells.

    abstract:OBJECTIVES:Posttraumatic invasive fungal infections threaten critically injured combat-related injuries and require a combination of extensive surgery and systemic antifungal therapy, along with topical antimicrobials used adjunctively to control the infection. We evaluated the in vitro activity of topical agents in va...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182830bf9

    authors: Barsoumian A,Sanchez CJ,Mende K,Tully CC,Beckius ML,Akers KS,Wenke JC,Murray CK

    更新日期:2013-08-01 00:00:00

  • The use of a biodegradable, load-bearing scaffold as a carrier for antibiotics in an infected open fracture model.

    abstract:OBJECTIVES:Open fractures with bone loss are common, disabling injuries. Biodegradable, load-bearing scaffolds able to carry high concentrations of local antibiotics are an emerging technology to address these injuries. This study investigates the use of such scaffolds with gentamicin (along with bone morphogenetic pro...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181ed1349

    authors: Stewart RL,Cox JT,Volgas D,Stannard J,Duffy L,Waites KB,Chu TM

    更新日期:2010-09-01 00:00:00

  • Regional anesthesia improves outcome after distal radius fracture fixation over general anesthesia.

    abstract:OBJECTIVE:To compare the efficacy of anesthetic type on clinical outcomes after operative treatment of distal radius fractures. DESIGN:Retrospective review of prospectively collected data. SETTING:Academic medical center. PATIENTS:One hundred eighty-seven patients with a distal radius fracture (OTA type 23) were ide...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318238becb

    authors: Egol KA,Soojian MG,Walsh M,Katz J,Rosenberg AD,Paksima N

    更新日期:2012-09-01 00:00:00

  • Bundled Care for Hip Fractures: A Machine-Learning Approach to an Untenable Patient-Specific Payment Model.

    abstract:OBJECTIVES:With the transition to a value-based model of care delivery, bundled payment models have been implemented with demonstrated success in elective lower extremity joint arthroplasty. Yet, hip fracture outcomes are dependent on patient-level factors that may not be optimized preoperatively due to acuity of care....

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001454

    authors: Karnuta JM,Navarro SM,Haeberle HS,Billow DG,Krebs VE,Ramkumar PN

    更新日期:2019-07-01 00:00:00

  • Calcaneal Avulsion Fractures: A Multicenter Analysis of Soft-Tissue Compromise and Early Fixation Failure.

    abstract:OBJECTIVE:To characterize the presentation and outcomes of calcaneal avulsion fractures. DESIGN:Case series. SETTING:Two ACS Level I trauma centers. PATIENTS/PARTICIPANTS:Forty-seven calcaneal avulsion fractures isolated from a cohort of 1365 calcaneus fractures treated over a 17-year period. MAIN OUTCOME MEASUREME...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000001582

    authors: Mitchell PM,OʼNeill DE,Branch E,Mir HR,Sanders RW,Collinge CA

    更新日期:2019-11-01 00:00:00

  • The Effect of Implant Failure After Symphyseal Plating on Functional Outcome and General Health.

    abstract:OBJECTIVES:To relate the incidence of implant failure after internal anterior fixation of the pelvic ring to functional outcome and the health-related quality of life in patients. DESIGN:Retrospective chart and radiographic review. SETTING:Level I Trauma center. METHODS:We retrospectively identified all patients who...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000501

    authors: Frietman B,Verbeek J,Biert J,Frölke JP

    更新日期:2016-06-01 00:00:00

  • Mechanical failure after locking plate fixation of unstable intertrochanteric femur fractures.

    abstract:OBJECTIVES:The aim of this study was analyze modes of mechanical failure in a consecutive cohort of patients and establish possible risk factors. DESIGN:This was a retrospective cohort study. SETTING:The study was conducted at an academic level-1 trauma center. PATIENTS:Twenty-nine patients (mean age 56 years, range...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e318251930d

    authors: Streubel PN,Moustoukas MJ,Obremskey WT

    更新日期:2013-01-01 00:00:00

  • The anterior intra-pelvic (modified rives-stoppa) approach for fixation of acetabular fractures.

    abstract:OBJECTIVES:Report the technical aspects, radiographic results, and complications after minimum 1-year follow up of the anterior intra-pelvic (AIP or modified Rives-Stoppa) approach as an alternative to the ilioinguinal approach for the treatment of acetabular fractures. DESIGN:Retrospective review. SETTING:Level I tr...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3181dd0b84

    authors: Sagi HC,Afsari A,Dziadosz D

    更新日期:2010-05-01 00:00:00

  • Regeneration of diaphyseal bone defects using resorbable poly(L/DL-lactide) and poly(D-lactide) membranes in the Yucatan pig model.

    abstract:OBJECTIVES:To determine the effects of tubular resorbable polymer membranes on the healing of a segmental diaphyseal bone defect. DESIGN:A randomized prospective study using the minipig model. Animals were evaluated with in vivo roentgenograms on a biweekly basis until explanted at twelve weeks. SETTING:After surgery...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199711000-00002

    authors: Meinig RP,Buesing CM,Helm J,Gogolewski S

    更新日期:1997-11-01 00:00:00

  • Evidence gaps in the global decade of road traffic safety.

    abstract::Road traffic accidents are a leading cause of global mortality. In March 2010, the United Nations General Assembly and the World Health Organization (WHO) officially proclaimed 2011-2020 as the "Decade of Action for Road Safety." Researchers must focus on vulnerable road users and low- and middle-income countries (LMI...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000103

    authors: Evaniew N,Godin K,Schemitsch EH,Bhandari M

    更新日期:2014-01-01 00:00:00

  • Biomechanical Assessment of Locked Plating for the Fixation of Patella Fractures.

    abstract:OBJECTIVE:To analyze the mechanical stability of locked plating in comparison with tension-band wiring for the fixation of fractures of the patella. METHODS:Biomechanical tests were performed on artificial foam patella specimens comparing an angular stable plate and monocortical screws with tension-band wiring. Tests ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000000309

    authors: Wurm S,Augat P,Bühren V

    更新日期:2015-09-01 00:00:00

  • Biomechanics of Ender rods, compression screw, and Zickel nail in the fixation of stable subtrochanteric femur osteotomies.

    abstract::Compression screws, Ender rods, and Zickel nails were evaluated mechanically to determine their resulting stability in the fixation of experimental subtrochanteric femur osteotomies. Twenty-five pairs of human cadaver femurs were used. Experimental osteotomies were created and a random member of each pair was fixed wi...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-199003000-00010

    authors: Wainer RA,Wright PH,Gilbert JA,Taylor DF

    更新日期:1990-01-01 00:00:00

  • Modern Results of Functional Bracing of Humeral Shaft Fractures: A Multicenter Retrospective Analysis.

    abstract:OBJECTIVES:To evaluate the rate of, and reasons for, conversion of closed treatment of humeral shaft fractures using a fracture brace, to surgical intervention. DESIGN:Multicenter, retrospective analysis. SETTING:Nine Level 1 trauma centers across the United States. PATIENTS:A total of 1182 patients with a closed hu...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001666

    authors: Serrano R,Mir HR,Sagi HC,Horwitz DS,Borade A,Ketz JP,Kistler BJ,Quade JH,Beebe MJ,Au BK,Sanders RW,Shah AR

    更新日期:2020-04-01 00:00:00

  • Anteroinferior 2.7-mm versus 3.5-mm plating for AO/OTA type B clavicle fractures: a comparative cohort clinical outcomes study.

    abstract:OBJECTIVES:To compare the Disability of the Arm, Shoulder, and Hand (DASH) and Constant scores, time to union, rate of union, patient cosmetic satisfaction rate, and the need for secondary procedures between 2.7- and 3.5-mm anteroinferior plating for Arbeitsgemeinschaft für Osteosynthesefragen (AO)/Orthopaedic Trauma A...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182693f32

    authors: Galdi B,Yoon RS,Choung EW,Reilly MC,Sirkin M,Smith WR,Liporace FA

    更新日期:2013-03-01 00:00:00

  • Ultrasound-Guided Nerve Blocks as Analgesia for Nonoperative Management of Distal Radius Fractures-Two Consecutive Randomized Controlled Trials.

    abstract:OBJECTIVES:To investigate whether a conventional fracture hematoma block (FHB) or an ultrasound-guided peripheral nerve block has more superior analgesic effect during nonoperative management of distal radius fractures in an emergency department setting. Two peripheral nerve block types were investigated, one at the le...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,随机对照试验

    doi:10.1097/BOT.0000000000001388

    authors: Siebelt M,Hartholt KA,van Winden DFM,Boot F,Papathanasiou D,Verdouw BC,de Vries MR,Mathijssen NM,Kraan GA

    更新日期:2019-04-01 00:00:00

  • Induced Membrane Technique: Pearls and Pitfalls.

    abstract::The induced membrane technique for reconstruction of bone defects has proved its effectiveness and is now widely accepted. The 2 stages procedure, implying a cement spacer in the first stage and a huge bone graft in the second stage, responds to rigorous technical details involving each phase of the procedure. Prerequ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000979

    authors: Masquelet AC

    更新日期:2017-10-01 00:00:00

  • Intramedullary plate fixation of a distal humerus fracture: a case report.

    abstract::A case of a complex distal humeral fracture is presented. The patient lacked sufficient bony architecture to allow for conventional reconstruction. A technique is described using an intramedullary plate to obtain bony stabilization and permit early range of motion exercises. ...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/00005131-200205000-00011

    authors: Russell GV Jr,Pearsall AW

    更新日期:2002-05-01 00:00:00

  • Periprosthetic femur fractures.

    abstract::Successful treatment of periprosthetic femur fractures, like all fractures, requires careful attention to understand the fracture pattern nuances, identifying and executing a rational treatment approach, and providing an appropriate postoperative recovery protocol. Unlike most other fractures, modification of standard...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,评审

    doi:10.1097/BOT.0000000000000282

    authors: Ricci WM

    更新日期:2015-03-01 00:00:00

  • Does Value Matter in Orthopaedic Trauma?: A Survey of Orthopaedic Trauma Association Members.

    abstract:OBJECTIVES:With value-based payment models on the horizon, this study was designed to examine the perceptions of value-based care among orthopaedic traumatologists and how they influence their practice. DESIGN:Systems-based survey study. SETTING:Orthopaedic Trauma Association (OTA) research surveys. PARTICIPANTS:OTA...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0000000000001622

    authors: Gorman TL,S Albersheim M,Parikh HR,Flagstad IR,Okelana AB,Vang S,Johal H,Cunningham BP

    更新日期:2019-11-01 00:00:00

  • Character, Incidence, and Predictors of Knee Pain and Activity After Infrapatellar Intramedullary Nailing of an Isolated Tibia Fracture.

    abstract:OBJECTIVE:To study the activity and incidence of knee pain after sustaining an isolated tibia fracture treated with an infrapatellar intramedullary nail at 1 year. DESIGN:Retrospective review of prospective cohort. SETTING:Multicenter Academic and Community hospitals. PATIENTS:Four hundred thirty-seven patients with...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章,多中心研究

    doi:10.1097/BOT.0000000000000475

    authors: Obremskey W,Agel J,Archer K,To P,Tornetta P 3rd,SPRINT Investigators.

    更新日期:2016-03-01 00:00:00

  • Do locking screws work in plates bent at holes?

    abstract:OBJECTIVES:To assess whether plate bending at a hole significantly changes the biomechanical properties of a locked screw. METHODS:Coronal plane bends of 5-, 15-, or 45-degree angles were placed in 3.5-mm locking compression plates with the apex at a locking hole. An additional 45-degree angle test group was created i...

    journal_title:Journal of orthopaedic trauma

    pub_type: 杂志文章

    doi:10.1097/BOT.0b013e3182a73a77

    authors: Boulton CL,Kim H,Shah SB,Ryan SP,Metzger TA,Hsieh AH,O'Toole RV