The reproducibility of deep-inspiration breath-hold (18)F-FDG PET/CT technique in diagnosing various cancers affected by respiratory motion.

Abstract:

BACKGROUND:The deep-inspiration breath-hold PET/CT (DIBH PET/CT) technique improves the limitations of diagnosing a lesion located in an area influenced by respiratory motion that results in spatial misregistrations caused by respiration between PET and CT. However, its reproducibility with regard to calculating the maximal standardized uptake value (SUV(max)) and metabolic volume (MV) in DIBH PET/CT has not been elucidated. OBJECTIVE:The purpose of this study was to investigate the reproducibility of the DIBH PET/CT technique including calculating the SUV(max) and the MV. METHODS:Sixty patients with various cancers were enrolled. The subjects had 47 abdominal lesions and 28 chest lesions. All patients demonstrated a misregistered image in the early whole-body image taken 50 min after FDG intravenous infusions. We added the delayed spot images 40 min after the first image. On the delayed image, we performed both conventional techniques with non-breath-hold (NBH) and the DIBH technique. In the four times DIBH technique, we obtained the coefficient of variance (CV) in calculating these indices for evaluating reproducibility. RESULTS:The SUV(max) value with DIBH showed an increase of 16.1-60.1% compared with that measured by NBH. The mean value of CV was 5.5 in thoracic lesions and 6.3 in abdominal lesions. The values of MV with DIBH showed a decrease of 14.0-20.1% compared with those measured by NBH. Regarding reproducibility, mean value of CV was 7.1 in thoracic lesions and 11.9 in abdominal lesions. CONCLUSION:The DIBH technique improves the inaccurate quantification of both SUV(max) and MV. Although the CV value of SUV(max) with DIBH technique is better in thoracic lesions compared with that in abdominal lesions, the reproducibility was acceptable.

journal_name

Ann Nucl Med

authors

Nagamachi S,Wakamatsu H,Kiyohara S,Fujita S,Futami S,Arita H,Tamura S,Kawai K

doi

10.1007/s12149-010-0352-3

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

171-8

issue

3

eissn

0914-7187

issn

1864-6433

journal_volume

24

pub_type

杂志文章
  • I-131 biokinetics of remnant normal thyroid tissue and residual thyroid cancer in patients with differentiated thyroid cancer: comparison between recombinant human TSH administration and thyroid hormone withdrawal.

    abstract:OBJECTIVE:The aim of this study was to assess I-131 biokinetics in thyroid cancer and remnant tissue in patients with differentiated thyroid cancer using whole-body scan (WBS) and SPECT images acquired after I-131 therapy. The influence of thyroid stimulating hormone (TSH) stimulation method on the kinetics was also ev...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-017-1188-x

    authors: Hong CM,Kim CY,Son SH,Jung JH,Lee CH,Jeong JH,Jeong SY,Lee SW,Lee J,Ahn BC

    更新日期:2017-10-01 00:00:00

  • Evaluation of diagnostic abilities of Ga-SPECT for head and neck lesions.

    abstract:OBJECTIVE:Single-photon emission computed tomography (SPECT) using gallium (Ga) has been frequently used for diagnosing head and neck tumors in patients. Although the usefulness of Ga-SPECT is well known, the degree of the increase in diagnostic ability with Ga-SPECT for head and neck tumors has not been reported. We c...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0116-x

    authors: Kotani J,Kawabe J,Higashiyama S,Kawamura E,Oe A,Hayashi T,Kurooka H,Tsumoto C,Kusuki M,Yamane H,Shiomi S

    更新日期:2008-05-01 00:00:00

  • Assessment of technetium-99m Technegas scintigraphy for ventilatory impairment in pulmonary emphysema: comparison of planar and SPECT images.

    abstract::Pulmonary emphysema can be diagnosed easily by X-ray CT (CT) as a low attenuation area. Recently Tc-99m-Technegas (Technegas) has been used for ventilation scintigraphy. The present study was undertaken to assess the usefulness of planar and SPECT images by using Technegas scintigraphy in patients with pulmonary emphy...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164818

    authors: Satoh K,Tanabe M,Takahashi K,Kobayashi T,Nishiyama Y,Yamamoto Y,Honjo N,Sasaki M,Ohkawa M,Fujita J,Okada H

    更新日期:1997-05-01 00:00:00

  • Performance assessment of the ALBIRA II pre-clinical SPECT S102 system for 99mTc imaging.

    abstract:OBJECTIVE:The performance characteristics of the SPECT sub-system S102 of the ALBIRA II PET/SPECT/CT are analyzed for the 80 mm field of view (FOV) to evaluate the potential in-vivo imaging in rats, based on measurements of the system response for the commonly used Technetium-99 m (99mTc) in small animal imaging. METH...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01547-7

    authors: Attarwala AA,Hardiansyah D,Romanó C,Jiménez-Franco LD,Roscher M,Wängler B,Glatting G

    更新日期:2021-01-01 00:00:00

  • Assessment of myocardial viability in patients with myocardial infarction using twenty-four hour thallium-201 late redistribution imaging.

    abstract:BACKGROUND:Rest thallium-201 (201Tl) myocardial perfusion imaging has been widely used for evaluation of myocardial ischemia/viability after myocardial infarction, but the ideal timing for imaging after injection to maximally estimate viability is not well established. METHODS:Thirty-six patients with myocardial infar...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF02985586

    authors: Yang XJ,He YM,Zhang B,Wu YW,Hui J,Jiang TB,Song JP,Liu ZH,Jiang WP

    更新日期:2006-01-01 00:00:00

  • Comparison of integrated whole-body PET/MR and PET/CT: Is PET/MR alternative to PET/CT in routine clinical oncology?

    abstract:PURPOSE:To compare the diagnostic accuracy of whole-body PET/CT and integrated PET/MR in relation to the total scan time durations. METHODS:One hundred and twenty-three (123) patients (40 males and 83 females; mean age 59.6 years; range 20-83 years) with confirmed primary cancer and clinical suspicion of metastatic di...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-1050-y

    authors: Ishii S,Shimao D,Hara T,Miyajima M,Kikuchi K,Takawa M,Kumamoto K,Ito H,Shishido F

    更新日期:2016-04-01 00:00:00

  • Synthesis and evaluation of radioiodinated phenoxyquinazoline and benzylaminoquinazoline derivatives as new EGF receptor tyrosine kinase imaging ligands for tumor diagnosis using SPECT.

    abstract:OBJECTIVE:Epidermal growth factor receptor tyrosine kinase (EGFR-TK) represents an attractive target for tumor diagnosis agents. Previously, the radioiodinated 4-(3-iodoanilino)-6,7-diethoxyquinazoline ([(125)I]m-IPQ) has been reported to possess good characteristics as a tumor imaging agent; however, it was also found...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-012-0583-6

    authors: Hirata M,Kanai Y,Naka S,Matsumuro K,Kagawa S,Yoshimoto M,Ohmomo Y

    更新日期:2012-06-01 00:00:00

  • Causes of false negatives in technetium-99 m methoxyisobutylisonitrile scintigraphy for hyperparathyroidism: influence of size and cysts in parathyroid lesions.

    abstract:OBJECTIVE:The aim of this study was to elucidate the causes of false-negative cases of technetium-99 m methoxyisobutylisonitrile scintigraphy (MIBI) for hyperparathyroidism. METHODS:Consecutive MIBI examinations performed in 154 patients between April 2011 and March 2017 were retrospectively reviewed. Sensitivities of...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01520-4

    authors: Ishii S,Sugawara S,Yaginuma Y,Kobiyama H,Hiruta M,Watanabe H,Yamakuni R,Hakozaki M,Fujimaki H,Ito H

    更新日期:2020-12-01 00:00:00

  • An animal PET scanner using flat-panel position-sensitive PMTs.

    abstract:OBJECTIVE:To design, build, and evaluate an animal PET scanner, which can be used with non-human primates under conscious condition, incorporating flat-panel position-sensitive photomultiplier tubes (PS-PMTs). METHODS:The system contains 30 detector modules, each having two PS-PMTs and 16×18 lutetium–yttrium oxyortho-...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0772-y

    authors: Okamoto T,Ote K,Sakai K,Noda A,Shimizu K,Masuda K,Ohmura T,Watanabe M

    更新日期:2014-01-01 00:00:00

  • Prediction of all-cause death using (11)C-hydroxyephedrine positron emission tomography in Japanese patients with left ventricular dysfunction.

    abstract:OBJECTIVES:The aim of this study was to determine whether (11)C-hydroxyephedrine ((11)C-HED) can predict adverse events including all-cause death in Japanese patients with left ventricular (LV) dysfunction. BACKGROUND:Although (11)C-HED PET has been used to assess cardiac sympathetic innervation in various disease con...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-016-1081-z

    authors: Fujita W,Matsunari I,Aoki H,Nekolla SG,Kajinami K

    更新日期:2016-08-01 00:00:00

  • Association of tau accumulation and atrophy in mild cognitive impairment: a longitudinal study.

    abstract:OBJECTIVE:To examine the patterns of longitudinal tau accumulation and cortical atrophy and their association in subjects with mild cognitive impairment (MCI). METHODS:We collected 23 participants (60-89 years old, 11 males/12 females) with MCI from the Alzheimer's Disease Neuroimaging Initiative database. All partici...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01506-2

    authors: Xu G,Zheng S,Zhu Z,Yu X,Jiang J,Jiang J,Chu Z,Alzheimer’s Disease Neuroimaging Initiative.

    更新日期:2020-11-01 00:00:00

  • Quantification evaluation of 99mTc-MDP concentration in the lumbar spine with SPECT/CT: compare with bone mineral density.

    abstract:BACKGROUND:Despite recent technological advances allowing for quantitative single-photon emission computed tomography (SPECT), quantitative SPECT has not been widely used in the clinical practice of osteoporosis. The aim of this study is to evaluate the feasibility of quantitative bone SPECT/CT for measuring lumbar sta...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01425-x

    authors: Huang K,Feng Y,Liu D,Liang W,Li L

    更新日期:2020-02-01 00:00:00

  • Choline PET/CT for imaging prostate cancer: an update.

    abstract::Whole-body positron emission tomography/computed tomography (PET/CT) with [(11)C]- and [(18)F]-labeled choline derivates has emerged as a promising molecular imaging modality for the evaluation of prostate cancer. (11)C- and (18)F-choline PET/CT are used successfully for restaging prostate cancer in patients with bioc...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/s12149-013-0731-7

    authors: Kitajima K,Murphy RC,Nathan MA

    更新日期:2013-08-01 00:00:00

  • The search for consistency in the manufacture of PET radiopharmaceuticals.

    abstract::Nuclear Medicine is the specialty of medical imaging, which utilizes a variety of radionuclides incorporated into specific compounds for diagnostic imaging and therapeutic applications. During recent years, research efforts in this discipline have concentrated on the decay characteristics of particular radionuclides a...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章,评审

    doi:10.1007/BF03164930

    authors: Finn RD

    更新日期:1999-12-01 00:00:00

  • Synthesis and evaluation of vesamicol analog (-)-O-[11C]methylvesamicol as a PET ligand for vesicular acetylcholine transporter.

    abstract::(-)-O-Methylvesamicol ((-)-OMV) exhibited in vitro a high affinity for vesicular acetylcholine transporter (VAChT) (Ki, 6.7 nM) and a relatively low affinity for sigmal receptor (Ki, 33.7 nM). We prepared (-)-[11C]OMV by a palladium-promoted cross-coupling reaction using [11C]methyl iodide, in a radiochemical yield of...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03027377

    authors: Kawamura K,Shiba K,Tsukada H,Nishiyama S,Mori H,Ishiwata K

    更新日期:2006-07-01 00:00:00

  • High metabolic tumor volume and total lesion glycolysis are associated with lateral lymph node metastasis in patients with incidentally detected thyroid carcinoma.

    abstract:OBJECTIVE:The objective of this study was to investigate whether total lesion glycolysis (TLG) and metabolic tumor volume (MTV) measured by ¹⁸F-fluorodeoxyglucose ((18)F-FDG) positron emission tomography/computed tomography (PET/CT) could predict the aggressiveness and lymph node metastasis (LNM) in patients with incid...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-015-0994-2

    authors: Kim BH,Kim SJ,Kim K,Kim H,Kim SJ,Kim WJ,Jeon YK,Kim SS,Kim YK,Kim IJ

    更新日期:2015-10-01 00:00:00

  • (99m)Tc-DTPA dynamic SPECT and CT volumetry for measuring split renal function in live kidney donors.

    abstract:OBJECTIVES:Split renal function (SRF) estimated from the posterior view of (99m)Tc-diethylenetriaminepentaacetic acid planar scintigraphy (DTPA/P) is not sufficiently accurate even after correction for kidney depth by computed tomography (CT). To obtain more accurate SRF using (99m)Tc-DTPA, dynamic SPECT method was car...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0349-y

    authors: Miyazaki C,Harada H,Shuke N,Okizaki A,Miura M,Hirano T

    更新日期:2010-04-01 00:00:00

  • Assessment of lung toxicity caused by bleomycin and amiodarone by Tc-99m HMPAO lung scintigraphy in rats.

    abstract:AIM:The purpose of the study was to determine the lung toxicity caused by amiodarone (AD) and bleomycin (BLM) in rats, by means of Tc-99m HMPAO lung scintigraphy. METHODS:Thirty albino rats were randomly divided into five groups. After AD or BLM was dissolved with isotonic saline (SF), a 0.5 ml solution was applied to...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-013-0722-8

    authors: Gumuser G,Vural K,Varol T,Parlak Y,Tuglu I,Topal G,Sayit E

    更新日期:2013-08-01 00:00:00

  • Relationships among regional diastolic impairment, elongation of global time to peak filling rate, and global diastolic function using ECG-gated myocardial perfusion SPECT in heart failure.

    abstract:OBJECTIVE:The relationships among regional diastolic impairment, the elongation of global time to peak filling rate (g-TPF), and global diastolic function were examined by a novel program using electrocardiography-gated myocardial perfusion single-photon emission computed tomography (SPECT) (GMPS) in heart failure (HF)...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-007-0046-7

    authors: Yamamoto A,Takahashi N,Munakata K,Abe K,Kobayashi Y,Tamai J,Shiiba M,Okuyama T,Kaneshiro T,Tsuruta H,Takama T,Satou M

    更新日期:2007-10-01 00:00:00

  • No delayed imaging or CCK administration is needed in most cases when bowel excretion does not occur but gallbladder fills promptly.

    abstract:OBJECTIVE:On hepatobiliary scintigraphy, "preferential gallbladder (GB) filling without tracer excretion into the small bowel (SB) [p-GB-no-SB]" is occasionally seen on images obtained up to an hour. In such cases, many practitioners administer cholecystokinin (CCK) (even when the measurement of GB ejection fraction is...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-019-01384-3

    authors: Choi HJ,Jacene H,Kim CK

    更新日期:2019-10-01 00:00:00

  • Introduction of the targeted alpha therapy (with Radium-223) into clinical practice in Japan: learnings and implementation.

    abstract::Radium-223 dichloride (Ra-223) is the first targeted alpha therapy approved for the treatment of patients with castration-resistant prostate cancer (CRPC) with bone metastasis. Ra-223 improved overall survival in the international Phase III ALSYMPCA (ALpharadin in SYMPtomatic Prostate Cancer) study. Ra-223 was also de...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-018-1317-1

    authors: Hosono M,Ikebuchi H,Nakamura Y,Yanagida S,Kinuya S

    更新日期:2019-03-01 00:00:00

  • Morphine-augmented cholescintigraphy enhances duodenogastric reflux.

    abstract::Morphine intervention in cholescintigraphy decreases imaging time to diagnose acute cholecystitis. Not infrequently we observe duodenogastric reflux during scintigraphy with and without morphine intervention. To evaluate occurrence of duodenogastric reflux related to morphine, we reviewed 55 patients who underwent cho...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03168405

    authors: Shih WJ,Lee JK,Magoun S,Wierzbinski B,Ryo UY

    更新日期:1995-11-01 00:00:00

  • [99mTc]3PRGD2 for integrin receptor imaging of esophageal cancer: a comparative study with [18F]FDG PET/CT.

    abstract:OBJECTIVES:This study was designed to investigate the efficacy of 99mtechnetium-three polyethylene glycol spacers-arginine-glycine-aspartic acid ([99mTc]3PRGD2) in the evaluation of patients with esophageal cancer. METHODS:Twenty-nine patients with a suspected esophageal lesion and for whom definite pathological diagn...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/s12149-018-1315-3

    authors: Zheng S,Chen Z,Huang C,Chen Y,Miao W

    更新日期:2019-02-01 00:00:00

  • Study on the primary visual cortex of visually impaired subjects by means of 123I-IMP SPECT and MRI.

    abstract::We conducted a study of rCBF in the primary visual cortex of visually impaired subjects who have not been subjected to external stimulation for a long period, by means of 123I-IMP SPECT and MRI. The four subjects had lost their sight due to brain tumors (n = 2), glaucoma (n = 1) and trauma (n = 1). 123I-IMP SPECT show...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03164976

    authors: Ishikawa N,Nishijo K,Satou M,Takeda T,Itai Y

    更新日期:1995-05-01 00:00:00

  • Derivation of attenuation map for attenuation correction of PET data in the presence of nanoparticulate contrast agents using spectral CT imaging.

    abstract:OBJECTIVE:Uptake value in quantitative PET imaging is biased due to the presence of CT contrast agents when using CT-based attenuation correction. Our aim was to examine spectral CT imaging to suppress inaccuracy of 511 keV attenuation map in the presence of multiple nanoparticulate contrast agents. METHODS:Using a si...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-014-0846-5

    authors: Ghadiri H,Shiran MB,Soltanian-Zadeh H,Rahmim A,Zaidi H,Ay MR

    更新日期:2014-07-01 00:00:00

  • The value of Bayesian penalized likelihood reconstruction for improving lesion conspicuity of malignant lung tumors on 18F-FDG PET/CT: comparison with ordered subset expectation maximization reconstruction incorporating time-of-flight model and point spre

    abstract:OBJECTIVE:To evaluate the value of Bayesian penalized likelihood (BPL) reconstruction for improving lesion conspicuity of malignant lung tumors on 18F-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography computed tomography (PET/CT) as compared with the ordered subset expectation maximization (OSEM) reconstructi...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-020-01446-x

    authors: Kurita Y,Ichikawa Y,Nakanishi T,Tomita Y,Hasegawa D,Murashima S,Hirano T,Sakuma H

    更新日期:2020-04-01 00:00:00

  • Thallium-201 brain SPECT to diagnose aggressiveness of meningiomas.

    abstract::This investigation was conducted to determine the ability of 201Tl brain SPECT with respect to preoperative prediction of lesional aggressiveness of meningioma. Fifty-nine lesions in 42 patients were examined. Early (15 min) and late (3 h) SPECT were obtained. Early uptake ratio (ER; lesion to normal brain average cou...

    journal_title:Annals of nuclear medicine

    pub_type: 临床试验,杂志文章

    doi:10.1007/BF03006435

    authors: Kinuya K,Ohashi M,Itoh S,Sakai S,Yamamoto K,Kakuda K,Nobata K,Terahata S,Taki S,Kinuya S

    更新日期:2003-09-01 00:00:00

  • A brain uptake study of [1-(11)C]hexanoate in the mouse: the effect of hypoxia, starvation and substrate competition.

    abstract::We evaluated the potential of sodium [1-(11)C]hexanoate (11C-HA) as a radiopharmaceutical with which to assess oxidative metabolism of the brain by PET. 11C-HA, sodium [1-(14)C]acetate and [3H]deoxyglucose were simultaneously injected into mice under control, hypoxic and starving conditions. In the control, the brain ...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF03165404

    authors: Ishiwata K,Ishii K,Ogawa K,Nozaki T,Senda M

    更新日期:1996-05-01 00:00:00

  • Transient seizure activity demonstrated by Tc-99m HMPAO SPECT and diffusion-weighted MR imaging.

    abstract::Cerebral perfusion single photon emission computed tomography (SPECT) has been used to confirm the localization of the epileptic focus and the evaluation of seizure. Recently, diffusion-weighted MR imaging (DWI) has been recognized for evaluation of seizure activity. We describe a case of transient seizure activity de...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/BF02987844

    authors: Sagiuchi T,Ishii K,Asano Y,Aoki Y,Woodhams R,Yanaihara H,Kan S,Hayakawa K

    更新日期:2001-06-01 00:00:00

  • Omission of [(15)O]CO scan for PET CMRO(2) examination using (15)O-labelled compounds.

    abstract:OBJECTIVE:CBF, OEF and CMRO(2) provide us important clinical indices and are used for assessing ischemic degree in cerebrovascular disorders. These quantitative images can be measured by PET using (15)O-labelled tracers such as C(15)O, C(15)O(2) and (15)O(2). To reduce the time of scan, one possibility is to omit the u...

    journal_title:Annals of nuclear medicine

    pub_type: 杂志文章

    doi:10.1007/s12149-010-0438-y

    authors: Sasakawa Y,Kudomi N,Yamamoto Y,Monden T,Kawai N,Nishiyama Y

    更新日期:2011-04-01 00:00:00