Wavelet optimization for content-based image retrieval in medical databases.

Abstract:

:We propose in this article a content-based image retrieval (CBIR) method for diagnosis aid in medical fields. In the proposed system, images are indexed in a generic fashion, without extracting domain-specific features: a signature is built for each image from its wavelet transform. These image signatures characterize the distribution of wavelet coefficients in each subband of the decomposition. A distance measure is then defined to compare two image signatures and thus retrieve the most similar images in a database when a query image is submitted by a physician. To retrieve relevant images from a medical database, the signatures and the distance measure must be related to the medical interpretation of images. As a consequence, we introduce several degrees of freedom in the system so that it can be tuned to any pathology and image modality. In particular, we propose to adapt the wavelet basis, within the lifting scheme framework, and to use a custom decomposition scheme. Weights are also introduced between subbands. All these parameters are tuned by an optimization procedure, using the medical grading of each image in the database to define a performance measure. The system is assessed on two medical image databases: one for diabetic retinopathy follow up and one for screening mammography, as well as a general purpose database. Results are promising: a mean precision of 56.50%, 70.91% and 96.10% is achieved for these three databases, when five images are returned by the system.

journal_name

Med Image Anal

journal_title

Medical image analysis

authors

Quellec G,Lamard M,Cazuguel G,Cochener B,Roux C

doi

10.1016/j.media.2009.11.004

subject

Has Abstract

pub_date

2010-04-01 00:00:00

pages

227-41

issue

2

eissn

1361-8415

issn

1361-8423

pii

S1361-8415(09)00141-8

journal_volume

14

pub_type

杂志文章
  • Bayesian principal geodesic analysis for estimating intrinsic diffeomorphic image variability.

    abstract::In this paper, we present a generative Bayesian approach for estimating the low-dimensional latent space of diffeomorphic shape variability in a population of images. We develop a latent variable model for principal geodesic analysis (PGA) that provides a probabilistic framework for factor analysis in the space of dif...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.04.009

    authors: Zhang M,Fletcher PT

    更新日期:2015-10-01 00:00:00

  • A novel deformation method for fast simulation of biological tissue formed by fibers and fluid.

    abstract::This paper presents a new approach to the simulation of soft tissues deformation suitable for real time computation, particularly intriguing for medical applications. The approach implements a quasi-static solution for elastic global deformations of objects filled with fluid and fibers, which can be a good approximati...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.04.002

    authors: Costa IF

    更新日期:2012-07-01 00:00:00

  • SDAE-GAN: Enable high-dimensional pathological images in liver cancer survival prediction with a policy gradient based data augmentation method.

    abstract::High-dimensional pathological images produced by Immunohistochemistry (IHC) methods consist of many pathological indexes, which play critical roles in cancer treatment planning. However, these indexes currently cannot be utilized in survival prediction because joining them with patients' clinicopathological features (...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101640

    authors: Wu H,Gao R,Sheng YP,Chen B,Li S

    更新日期:2020-05-01 00:00:00

  • Intensity inhomogeneity correction of SD-OCT data using macular flatspace.

    abstract::Images of the retina acquired using optical coherence tomography (OCT) often suffer from intensity inhomogeneity problems that degrade both the quality of the images and the performance of automated algorithms utilized to measure structural changes. This intensity variation has many causes, including off-axis acquisit...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2017.09.008

    authors: Lang A,Carass A,Jedynak BM,Solomon SD,Calabresi PA,Prince JL

    更新日期:2018-01-01 00:00:00

  • RMDL: Recalibrated multi-instance deep learning for whole slide gastric image classification.

    abstract::The whole slide histopathology images (WSIs) play a critical role in gastric cancer diagnosis. However, due to the large scale of WSIs and various sizes of the abnormal area, how to select informative regions and analyze them are quite challenging during the automatic diagnosis process. The multi-instance learning bas...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101549

    authors: Wang S,Zhu Y,Yu L,Chen H,Lin H,Wan X,Fan X,Heng PA

    更新日期:2019-12-01 00:00:00

  • Ultrasonic and elasticity imaging to model disease-induced changes in soft-tissue structure.

    abstract::Ultrasonic techniques are presented for the study of soft biological tissue structure and function. Changes in echo waveforms caused by microscopic variations in the mechanical properties of tissue can reveal disease mechanism, in vivo. On a larger scale, elasticity imaging describes the macroscopic mechanical propert...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/s1361-8415(98)80014-5

    authors: Chaturvedi P,Insana MF,Hall TJ

    更新日期:1998-12-01 00:00:00

  • SNR enhancement of highly-accelerated real-time cardiac MRI acquisitions based on non-local means algorithm.

    abstract::Real-time cardiac MRI appears as a promising technique to evaluate the mechanical function of the heart. However, ultra-fast MRI acquisitions come with an important signal-to-noise ratio (SNR) penalty, which drastically reduces the image quality. Hence, a real-time denoising approach would be desirable for SNR amelior...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2009.05.006

    authors: Naegel B,Cernicanu A,Hyacinthe JN,Tognolini M,Vallée JP

    更新日期:2009-08-01 00:00:00

  • Development and comparison of new hybrid motion tracking for bronchoscopic navigation.

    abstract::This paper presents a new hybrid camera motion tracking method for bronchoscopic navigation combining SIFT, epipolar geometry analysis, Kalman filtering, and image registration. In a thorough evaluation, we compare it to state-of-the-art tracking methods. Our hybrid algorithm for predicting bronchoscope motion uses SI...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.11.001

    authors: Luó X,Feuerstein M,Deguchi D,Kitasaka T,Takabatake H,Mori K

    更新日期:2012-04-01 00:00:00

  • Towards cross-modal organ translation and segmentation: A cycle- and shape-consistent generative adversarial network.

    abstract::Synthesized medical images have several important applications. For instance, they can be used as an intermedium in cross-modality image registration or used as augmented training samples to boost the generalization capability of a classifier. In this work, we propose a generic cross-modality synthesis approach with t...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.12.002

    authors: Cai J,Zhang Z,Cui L,Zheng Y,Yang L

    更新日期:2019-02-01 00:00:00

  • Local spatio-temporal encoding of raw perfusion MRI for the prediction of final lesion in stroke.

    abstract::We address the medical image analysis issue of predicting the final lesion in stroke from early perfusion magnetic resonance imaging. The classical processing approach for the dynamical perfusion images consists in a temporal deconvolution to improve the temporal signals associated with each voxel before performing pr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.08.008

    authors: Giacalone M,Rasti P,Debs N,Frindel C,Cho TH,Grenier E,Rousseau D

    更新日期:2018-12-01 00:00:00

  • A subject-specific technique for respiratory motion correction in image-guided cardiac catheterisation procedures.

    abstract::We describe a system for respiratory motion correction of MRI-derived roadmaps for use in X-ray guided cardiac catheterisation procedures. The technique uses a subject-specific affine motion model that is quickly constructed from a short pre-procedure MRI scan. We test a dynamic MRI sequence that acquires a small numb...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2009.01.003

    authors: King AP,Boubertakh R,Rhode KS,Ma YL,Chinchapatnam P,Gao G,Tangcharoen T,Ginks M,Cooklin M,Gill JS,Hawkes DJ,Razavi RS,Schaeffter T

    更新日期:2009-06-01 00:00:00

  • Segmentation of 4D cardiac MR images using a probabilistic atlas and the EM algorithm.

    abstract::In this paper an automatic atlas-based segmentation algorithm for 4D cardiac MR images is proposed. The algorithm is based on the 4D extension of the expectation maximisation (EM) algorithm. The EM algorithm uses a 4D probabilistic cardiac atlas to estimate the initial model parameters and to integrate a priori inform...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2004.06.005

    authors: Lorenzo-Valdés M,Sanchez-Ortiz GI,Elkington AG,Mohiaddin RH,Rueckert D

    更新日期:2004-09-01 00:00:00

  • Sensorless freehand 3D ultrasound in real tissue: speckle decorrelation without fully developed speckle.

    abstract::It has previously been demonstrated that freehand 3D ultrasound can be acquired without a position sensor by measuring the elevational speckle decorrelation from frame to frame. However, this requires that the B-scans contain significant amounts of fully developed speckle. In this paper, we show that this condition is...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2005.08.001

    authors: Gee AH,James Housden R,Hassenpflug P,Treece GM,Prager RW

    更新日期:2006-04-01 00:00:00

  • Automated annotation and quantitative description of ultrasound videos of the fetal heart.

    abstract::Interpretation of ultrasound videos of the fetal heart is crucial for the antenatal diagnosis of congenital heart disease (CHD). We believe that automated image analysis techniques could make an important contribution towards improving CHD detection rates. However, to our knowledge, no previous work has been done in t...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2016.11.006

    authors: Bridge CP,Ioannou C,Noble JA

    更新日期:2017-02-01 00:00:00

  • Computer aided diagnosis of thyroid nodules based on the devised small-datasets multi-view ensemble learning.

    abstract::With the development of deep learning, its application in diagnosis of benign and malignant thyroid nodules has been widely concerned. However, it is difficult to obtain medical images, resulting in insufficient number of data, which contradicts the large amount of data required for acquiring effective deep learning d...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101819

    authors: Chen Y,Li D,Zhang X,Jin J,Shen Y

    更新日期:2021-01-01 00:00:00

  • Exudate detection in color retinal images for mass screening of diabetic retinopathy.

    abstract::The automatic detection of exudates in color eye fundus images is an important task in applications such as diabetic retinopathy screening. The presented work has been undertaken in the framework of the TeleOphta project, whose main objective is to automatically detect normal exams in a tele-ophthalmology network, thu...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.05.004

    authors: Zhang X,Thibault G,Decencière E,Marcotegui B,Laÿ B,Danno R,Cazuguel G,Quellec G,Lamard M,Massin P,Chabouis A,Victor Z,Erginay A

    更新日期:2014-10-01 00:00:00

  • Quantitative analysis of retinal OCT.

    abstract::Clinical acceptance of 3-D OCT retinal imaging brought rapid development of quantitative 3-D analysis of retinal layers, vasculature, retinal lesions as well as facilitated new research in retinal diseases. One of the cornerstones of many such analyses is segmentation and thickness quantification of retinal layers and...

    journal_title:Medical image analysis

    pub_type: 社论

    doi:10.1016/j.media.2016.06.001

    authors: Sonka M,Abràmoff MD

    更新日期:2016-10-01 00:00:00

  • Shape regression machine and efficient segmentation of left ventricle endocardium from 2D B-mode echocardiogram.

    abstract::We present a machine learning approach called shape regression machine (SRM) for efficient segmentation of an anatomic structure that exhibits a deformable shape in a medical image, e.g., left ventricle endocardial wall in an echocardiogram. The SRM achieves efficient segmentation via statistical learning of the inter...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.04.002

    authors: Zhou SK

    更新日期:2010-08-01 00:00:00

  • Predicting the progression of mild cognitive impairment using machine learning: A systematic, quantitative and critical review.

    abstract::We performed a systematic review of studies focusing on the automatic prediction of the progression of mild cognitive impairment to Alzheimer's disease (AD) dementia, and a quantitative analysis of the methodological choices impacting performance. This review included 172 articles, from which 234 experiments were extr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2020.101848

    authors: Ansart M,Epelbaum S,Bassignana G,Bône A,Bottani S,Cattai T,Couronné R,Faouzi J,Koval I,Louis M,Thibeau-Sutre E,Wen J,Wild A,Burgos N,Dormont D,Colliot O,Durrleman S

    更新日期:2021-01-01 00:00:00

  • Multiple hypothesis template tracking of small 3D vessel structures.

    abstract::A multiple hypothesis tracking approach to the segmentation of small 3D vessel structures is presented. By simultaneously tracking multiple hypothetical vessel trajectories, low contrast passages can be traversed, leading to an improved tracking performance in areas of low contrast. This work also contributes a novel ...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2009.12.003

    authors: Friman O,Hindennach M,Kühnel C,Peitgen HO

    更新日期:2010-04-01 00:00:00

  • Quantification of the detailed cardiac left ventricular trabecular morphogenesis in the mouse embryo.

    abstract::During embryogenesis, a mammalian heart develops from a simple tubular shape into a complex 4-chamber organ, going through four distinct phases: early primitive tubular heart, emergence of trabeculations, trabecular remodeling and development of the compact myocardium. In this paper we propose a framework for standard...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.08.001

    authors: Paun B,Bijnens B,Cook AC,Mohun TJ,Butakoff C

    更新日期:2018-10-01 00:00:00

  • Real-time image-based rigid registration of three-dimensional ultrasound.

    abstract::Registration of three-dimensional ultrasound (3DUS) volumes is necessary in several applications, such as when stitching volumes to expand the field of view or when stabilizing a temporal sequence of volumes to cancel out motion of the probe or anatomy. Current systems that register 3DUS volumes either use external tr...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2011.10.004

    authors: Schneider RJ,Perrin DP,Vasilyev NV,Marx GR,Del Nido PJ,Howe RD

    更新日期:2012-02-01 00:00:00

  • Unmixing dynamic PET images with variable specific binding kinetics.

    abstract::To analyze dynamic positron emission tomography (PET) images, various generic multivariate data analysis techniques have been considered in the literature, such as principal component analysis (PCA), independent component analysis (ICA), factor analysis and nonnegative matrix factorization (NMF). Nevertheless, these c...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.07.011

    authors: Cavalcanti YC,Oberlin T,Dobigeon N,Stute S,Ribeiro M,Tauber C

    更新日期:2018-10-01 00:00:00

  • Concurrent tumor segmentation and registration with uncertainty-based sparse non-uniform graphs.

    abstract::In this paper, we present a graph-based concurrent brain tumor segmentation and atlas to diseased patient registration framework. Both segmentation and registration problems are modeled using a unified pairwise discrete Markov Random Field model on a sparse grid superimposed to the image domain. Segmentation is addres...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2014.02.006

    authors: Parisot S,Wells W 3rd,Chemouny S,Duffau H,Paragios N

    更新日期:2014-05-01 00:00:00

  • IDRiD: Diabetic Retinopathy - Segmentation and Grading Challenge.

    abstract::Diabetic Retinopathy (DR) is the most common cause of avoidable vision loss, predominantly affecting the working-age population across the globe. Screening for DR, coupled with timely consultation and treatment, is a globally trusted policy to avoid vision loss. However, implementation of DR screening programs is chal...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2019.101561

    authors: Porwal P,Pachade S,Kokare M,Deshmukh G,Son J,Bae W,Liu L,Wang J,Liu X,Gao L,Wu T,Xiao J,Wang F,Yin B,Wang Y,Danala G,He L,Choi YH,Lee YC,Jung SH,Li Z,Sui X,Wu J,Li X,Zhou T,Toth J,Baran A,Kori A,Ch

    更新日期:2020-01-01 00:00:00

  • 4D hyperspherical harmonic (HyperSPHARM) representation of surface anatomy: a holistic treatment of multiple disconnected anatomical structures.

    abstract::Image-based parcellation of the brain often leads to multiple disconnected anatomical structures, which pose significant challenges for analyses of morphological shapes. Existing shape models, such as the widely used spherical harmonic (SPHARM) representation, assume topological invariance, so are unable to simultaneo...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2015.02.004

    authors: Pasha Hosseinbor A,Chung MK,Koay CG,Schaefer SM,van Reekum CM,Schmitz LP,Sutterer M,Alexander AL,Davidson RJ

    更新日期:2015-05-01 00:00:00

  • Comparison of atlas-based techniques for whole-body bone segmentation.

    abstract::We evaluate the accuracy of whole-body bone extraction from whole-body MR images using a number of atlas-based segmentation methods. The motivation behind this work is to find the most promising approach for the purpose of MRI-guided derivation of PET attenuation maps in whole-body PET/MRI. To this end, a variety of a...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2016.11.003

    authors: Arabi H,Zaidi H

    更新日期:2017-02-01 00:00:00

  • Tongue contour tracking in dynamic ultrasound via higher-order MRFs and efficient fusion moves.

    abstract::Analyses of the human tongue motion as captured from 2D dynamic ultrasound data often requires segmentation of the mid-sagittal tongue contours. However, semi-automatic extraction of the tongue shape presents practical challenges. We approach this segmentation problem by proposing a novel higher-order Markov random fi...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2012.07.001

    authors: Tang L,Bressmann T,Hamarneh G

    更新日期:2012-12-01 00:00:00

  • A work flow to build and validate patient specific left atrium electrophysiology models from catheter measurements.

    abstract::Biophysical models of the atrium provide a physically constrained framework for describing the current state of an atrium and allow predictions of how that atrium will respond to therapy. We propose a work flow to simulate patient specific electrophysiological heterogeneity from clinical data and validate the resultin...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2018.04.005

    authors: Corrado C,Williams S,Karim R,Plank G,O'Neill M,Niederer S

    更新日期:2018-07-01 00:00:00

  • Independent component analysis using prior information for signal detection in a functional imaging system of the retina.

    abstract::Independent component analysis (ICA) is a statistical technique that estimates a set of sources mixed by an unknown mixing matrix using only a set of observations. For this purpose, the only assumption is that the sources are statistically independent. In many applications, some information about the nature of the unk...

    journal_title:Medical image analysis

    pub_type: 杂志文章

    doi:10.1016/j.media.2010.06.009

    authors: Barriga ES,Pattichis M,Ts'o D,Abramoff M,Kardon R,Kwon Y,Soliz P

    更新日期:2011-02-01 00:00:00