Primary anterior chamber intraocular lens for the treatment of severe crystalline lens subluxation.

Abstract:

:Subluxated cataractous and clear lenses are commonly treated by limbal or pars plana lensectomy followed by primary or secondary intraocular lens (IOL) implantation. Adjunctive capsular prosthetic devices have facilitated lens removal and IOL centration in these challenging cases but have also added complexity and potential complications to the procedure. Although crystalline lens extraction may be required to clear the visual axis in mild to moderate lens subluxations, we propose insertion of a primary anterior chamber IOL without lens extraction in severe subluxations when the eye is optically aphakic or can be made functionally aphakic following neodymium:YAG laser zonulysis. Two cases demonstrating this approach are presented.

authors

Hoffman RS,Fine IH,Packer M

doi

10.1016/j.jcrs.2009.05.019

subject

Has Abstract

pub_date

2009-10-01 00:00:00

pages

1821-5

issue

10

eissn

0886-3350

issn

1873-4502

pii

S0886-3350(09)00591-4

journal_volume

35

pub_type

杂志文章
  • Keratitis complicated by endophthalmitis 3 years after astigmatic keratotomy.

    abstract::Endophthalmitis after keratotomy is rare and usually occurs soon after surgery. A 56-year-old woman with mild dry-eye symptoms developed keratitis complicated by endophthalmitis 3 years after astigmatic keratotomy (AK). The keratitis lasted for less than 1 day in the upper keratotomy incision. Corneal cultures yielded...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80029-1

    authors: Erkin EF,Durak I,Ferliel S,Maden A

    更新日期:1998-09-01 00:00:00

  • Early postoperative safety and surgical outcomes after implantation of a suprachoroidal micro-stent for the treatment of open-angle glaucoma concomitant with cataract surgery.

    abstract:PURPOSE:To evaluate the safety of a new suprachoroidal device, the Cypass micro-stent, for the surgical treatment of open-angle glaucoma (OAG) implanted in conjunction with cataract surgery. SETTING:Multicenter clinical study. DESIGN:Prospective interventional case series. METHODS:This is an interim report of an ong...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2012.10.040

    authors: Hoeh H,Ahmed II,Grisanti S,Grisanti S,Grabner G,Nguyen QH,Rau M,Yoo S,Ianchulev T

    更新日期:2013-03-01 00:00:00

  • Implantation of 2 trabecular microbypass stents in a patient with primary open-angle glaucoma refractory to previous glaucoma-filtering surgeries.

    abstract:UNLABELLED:A 77-year-old woman with primary open-angle glaucoma was referred for surgical evaluation after failing to achieve target intraocular pressure (IOP) despite previous combined phacotrabeculectomy and Ahmed valve implantations. The IOP prior to surgery was 28 mm Hg on topical dorzolamide-timolol, latanoprost, ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2014.06.017

    authors: Roelofs K,Arora S,Dorey MW

    更新日期:2014-08-01 00:00:00

  • 200 Hz flying-spot technology of the LaserSight LSX excimer laser in the treatment of myopic astigmatism: six and 12 month outcomes of laser in situ keratomileusis and photorefractive keratectomy.

    abstract:PURPOSE:To evaluate safety, efficacy, predictability, and stability in the treatment of myopic astigmatism with laser in situ keratomileusis (LASIK) and photorefractive keratectomy (PRK) using the 200 Hz flying-spot technology of the LaserSight LSX excimer laser. SETTING:SynsLaser Clinic, Tromsø, Norway. METHODS:This...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)00996-8

    authors: Stojanovic A,Nitter TA

    更新日期:2001-08-01 00:00:00

  • Laser in situ keratomileusis for consecutive hyperopia after myopic LASIK and radial keratotomy.

    abstract:PURPOSE:To evaluate and compare the efficacy, predictability, and safety of hyperopic laser in situ keratomileusis (H-LASIK) for the correction of consecutive hyperopia after myopic-LASIK (M-LASIK) and radial keratotomy (RK). SETTING:The Eye Institute of Utah, Salt Lake City, Utah, USA. METHODS:Seventy-seven eyes of ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(03)00051-8

    authors: Lyle WA,Jin GJ

    更新日期:2003-05-01 00:00:00

  • Refractive change in pediatric pseudophakia: 6-year follow-up.

    abstract:PURPOSE:To evaluate the long-term evolution of refractive error changes in eyes of children who have primary intraocular lens (IOL) implantation to allow more accurate prediction of what IOL power should be implanted at a given age. SETTING:Department of Ophthalmology, Indiana University School of Medicine, Indianapol...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01156-7

    authors: Plager DA,Kipfer H,Sprunger DT,Sondhi N,Neely DE

    更新日期:2002-05-01 00:00:00

  • Inhibition of posterior capsule opacification with an immunotoxin specific for lens epithelial cells: 24 month clinical results.

    abstract:PURPOSE:To assess the safety and effectiveness of an immunotoxin, MDX-RA, designed to inhibit posterior capsule opacification (PCO). SETTING:Eleven private practices in the United States. METHODS:This study comprised 63 eyes of 63 patients having extracapsular cataract extraction by phacoemulsification; these patient...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章,多中心研究,随机对照试验

    doi:10.1016/s0886-3350(98)80352-0

    authors: Clark DS,Emery JM,Munsell MF

    更新日期:1998-12-01 00:00:00

  • Accommodation measurements in a prepresbyopic and presbyopic population.

    abstract:PURPOSE:To study the efficacy of several subjective and objective methods of accommodation measurement in normal prepresbyopic and presbyopic populations to identify appropriate methods for measuring the outcome of accommodative restorative procedures. SETTING:University of Houston, College of Optometry, Houston, Texa...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2003.12.045

    authors: Ostrin LA,Glasser A

    更新日期:2004-07-01 00:00:00

  • Imaging corneal crosslinking by autofluorescence 2-photon microscopy, second harmonic generation, and fluorescence lifetime measurements.

    abstract:PURPOSE:To evaluate the use of 2-photon microscopy (TPM), which excites tissue autofluorescence, in detecting and calculating the grade of collagen corneal crosslinks, which are not visible through the slitlamp and in vivo confocal microscopy. SETTING:Departments of Ophthalmology, University of Lübeck, Lübeck, and Uni...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.06.068

    authors: Steven P,Hovakimyan M,Guthoff RF,Hüttmann G,Stachs O

    更新日期:2010-12-01 00:00:00

  • Toxic endothelial cell destruction syndrome after intraocular lens repositioning with intracameral epinephrine.

    abstract::A 66-year-old Chinese man developed corneal endothelial decompensation after intraocular lens (IOL) repositioning using intracameral epinephrine was performed. The presentation was compatible with toxic endothelial cell destruction syndrome, which is caused by prolonged, direct exposure of the corneal endothelium to r...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2008.05.059

    authors: Pong JC,Tang WW,Lai JS

    更新日期:2008-11-01 00:00:00

  • Implantation of an Artisan iris-fixated phakic intraocular lens for the correction of hyperopia, a 15 year follow-up.

    abstract:PURPOSE:To assess the predictability, efficacy, stability and safety of implantation of an Artisan (Ophtec BV, the Netherlands) iris-fixated phakic intraocular lens (IF-pIOL) for the correction of hyperopia with a follow-up of up to 15 years. SETTING:Leiden University Medical Center, The Netherlands METHODS:: Patients...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1097/j.jcrs.0000000000000532

    authors: van Rijn GA,Gaurisankar ZS,Saxena R,Gibbes D,Jongman HP,Haasnoot GW,Cheng YYY,Beenakker JM,Luyten GPM

    更新日期:2020-11-27 00:00:00

  • Fluorescence-guided laser removal of chemically damaged cornea.

    abstract:PURPOSE:To correlate the observed fluorescence spectrum with the depth of ablation during 193 nm argon-fluoride excimer laser ablation of chemically damaged corneas. SETTING:Laser facility, Cedars-Sinai Medical Center, Los Angeles, California, USA. METHODS:Three cadaver New Zealand white rabbit corneas were exposed t...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01361-5

    authors: Chuck RS,Arnoldussen ME,Behrens A,Sweet PM,Bearman GH,Grundfest WS

    更新日期:2002-10-01 00:00:00

  • Smoothness assessment of corneal stromal surfaces.

    abstract:PURPOSE:To assess the accuracy of the scanning electron microscopy (SEM) and present alternative approaches to quantify surface roughness based on numerical analysis. SETTING:Department of Ophthalmology, Maisonneuve-Rosemont Hospital, University of Montreal, Montreal, Quebec, Canada. DESIGN:Experimental study. METHO...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2012.08.050

    authors: Marian A,Nada O,Légaré F,Meunier J,Vidal F,Roy S,Brunette I,Costantino S

    更新日期:2013-01-01 00:00:00

  • Accuracy and predictability of intraocular lens power calculation after photorefractive keratectomy.

    abstract:PURPOSE:To investigate the accuracy and predictability of intraocular lens (IOL) power calculation in postoperative photorefractive keratectomy (PRK) eyes. SETTING:Gimbel Eye Centre, Calgary, Alberta, Canada. METHODS:The results in 5 cataract surgery eyes that had had PRK were analyzed retrospectively. Target refract...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00480-6

    authors: Gimbel HV,Sun R,Furlong MT,van Westenbrugge JA,Kassab J

    更新日期:2000-08-01 00:00:00

  • Model of anesthesia care that combines anesthesiologists and registered nurses during cataract surgery.

    abstract:PURPOSE:To determine the safety and practicality of a combined anesthesiologist and registered nurse model of anesthesia care in cataract surgery. SETTING:Mayo Clinic, Rochester, Minnesota, USA. DESIGN:Case series. METHODS:This retrospective review comprised consecutive patients having phacoemulsification cataract s...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.09.021

    authors: Erie AJ,McHugh R,Warner M,Erie JC

    更新日期:2011-03-01 00:00:00

  • Excimer ablation design and elliptical transition zones.

    abstract:PURPOSE:To describe the rationale behind elliptical and other transition designs used with the excimer laser. SETTING:Casey Eye Institute, Oregon Health Sciences University, Portland, Oregon, USA. METHODS:Ablation zone designs were analyzed for the number of transition points for myopia and hyperopia. The advantages ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00144-3

    authors: MacRae S

    更新日期:1999-09-01 00:00:00

  • Comparison of 2 monocular pupillometers and an autorefractor for measurement of the dark-adapted pupil diameter.

    abstract:PURPOSE:To compare the performance of the Marco Nidek ARK-530A autorefractor pupillometer function and the Keeler PupilScan II pupillometer (study pupillometer) against the clinical standard NeurOptics PLR-200 pupillometer (standard pupillometer) for measurement of the dark-adapted pupil diameter. SETTING:Department o...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2010.10.059

    authors: Brown SM,Bradley JC

    更新日期:2011-04-01 00:00:00

  • Refractive surgery in the HIV-positive U.S. Military Natural History Study Cohort: complications and risk factors.

    abstract:PURPOSE:This study sought to assess the frequency of refractive surgery complications in HIV+ individuals and related risk factors. SETTINGS:Multiple centers in the United States. DESIGN:Prospective observational cohort study. METHODS:The U.S. Military HIV Natural History Study is a prospective observational cohort ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章,多中心研究

    doi:10.1016/j.jcrs.2019.06.017

    authors: Tisdale CS,Justin GA,Wang X,Chu X,Carlton DK,Okulicz JF,Schofield C,Maves RC,Agan BK,Legault GL,Infectious Disease Clinical Research Program HIV Working Group.

    更新日期:2019-11-01 00:00:00

  • Refractive Surgery Survey 2001.

    abstract::In February 2001, a questionnaire on the practice of refractive surgery was sent worldwide to all 8196 members of the American Society of Cataract and Refractive Surgery; 1511 responses (18.4%) were received. Although laser in situ keratomileusis (LASIK) was the most common refractive procedure reported, phakic intrao...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(01)01318-9

    authors: Solomon KD,Holzer MP,Sandoval HP,Vargas LG,Werner L,Vroman DT,Kasper TJ,Apple DJ

    更新日期:2002-02-01 00:00:00

  • Two-year follow-up of the Artisan/Verisyse iris-supported phakic intraocular lens for the correction of high myopia.

    abstract:PURPOSE:To evaluate the implantation of Artisan/Verisyse phakic intraocular lenses (pIOLs) (Advanced Medical Optics) as an effective and safe method for the correction of high myopia. SETTING:Department of Ophthalmology, John A. Moran Eye Center, University of Utah Medical Center, Salt Lake City, Utah, USA. METHODS:T...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2007.04.009

    authors: Moshirfar M,Holz HA,Davis DK

    更新日期:2007-08-01 00:00:00

  • Visualizing vitreous using Kenalog suspension.

    abstract::We developed and evaluated a method of visualizing vitreous gel in the anterior segment. In this study, 0.2 mL of injectable triamcinolone (Kenalog) 40 mg/mL was captured in a 5 microm filter and rinsed with 2 mL of balanced salt solution (BSS). It was then resuspended in 5 mL of BSS and recaptured to thoroughly remov...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 临床试验,杂志文章

    doi:10.1016/s0886-3350(03)00016-6

    authors: Burk SE,Da Mata AP,Snyder ME,Schneider S,Osher RH,Cionni RJ

    更新日期:2003-04-01 00:00:00

  • Long-term visual outcome after cataract surgery: comparison of healthy eyes and eyes with age-related macular degeneration.

    abstract:PURPOSE:To compare the long-term longitudinal visual acuity outcomes after cataract surgery in eyes with age-related macular degeneration (AMD) at surgery and eyes without comorbidity. SETTING:University-based eye clinic. DESIGN:Longitudinal cohort study. METHODS:Patients having cataract surgery were evaluated over ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2011.09.041

    authors: Mönestam E,Lundqvist B

    更新日期:2012-03-01 00:00:00

  • The 45 degree tilt: improvement in surgical ergonomics.

    abstract::The ergonomics of ocular surgery has received little attention even though the usual positioning of the patient and surgeon during traditional cataract surgery places the surgeon at risk for back, neck, and arm strain. The recent development of the temporal cataract incision allows the operating microscope to be tilte...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)80122-9

    authors: Wallace RB 3rd

    更新日期:1999-02-01 00:00:00

  • Localized liquefied after-cataract.

    abstract::We report 2 cases with a new type of after-cataract. In both, a milky white substance accumulated in a semicircular, closed chamber formed by the intraocular lens optic and the posterior lens capsule. Unlike in previous reports, the closed chamber did not cover the entire capsule but was based on residual lens remnant...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(02)01423-2

    authors: Namiki I,Miyake K,Ota I,Miyake S

    更新日期:2003-01-01 00:00:00

  • Collagen copolymer toric posterior chamber phakic intraocular lens in eyes with keratoconus.

    abstract:PURPOSE:To assess the safety, efficacy, stability, and predictability of collagen copolymer toric phakic intraocular lens (pIOL) implantation to correct myopia and astigmatism in eyes with keratoconus. SETTING:Fernández-Vega Ophthalmological Institute, Oviedo, Spain. METHODS:This prospective study comprised keratocon...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2009.11.032

    authors: Alfonso JF,Fernández-Vega L,Lisa C,Fernandes P,González-Méijome JM,Montés-Micó R

    更新日期:2010-06-01 00:00:00

  • Intraocular lens opacification after nonpenetrating glaucoma surgery with mitomycin-C.

    abstract::A 58-year-old woman had successful phacoemulsification with intraocular lens (IOL) implantation in January 2001. Two years later, nonpenetrating glaucoma surgery with mitomycin-C (MMC) 0.02% was performed for uncontrolled glaucoma. Two months later, opacification of the anterior IOL surface was observed. The IOL was r...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2006.07.038

    authors: Moreno-Montañés J,Palop JA,García-Gómez P,Heras H,Cristóbal JA

    更新日期:2007-01-01 00:00:00

  • Blue-light filtering intraocular lens in patients with diabetes: contrast sensitivity and chromatic discrimination.

    abstract:PURPOSE:To evaluate potential changes in contrast sensitivity and color discrimination in diabetic patients who had cataract surgery and implantation of the blue-light filtering AcrySof Natural (SN60AT) intraocular lens (IOL) compared with an ultraviolet-only filtering (AcrySof SA60AT) IOL. SETTING:Refractive Surgery ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/j.jcrs.2005.04.029

    authors: Rodríguez-Galietero A,Montés-Micó R,Muñoz G,Albarrán-Diego C

    更新日期:2005-11-01 00:00:00

  • Photorefractive keratectomy in keratoconus suspects.

    abstract:PURPOSE:To compare the refractive outcome after photorefractive keratectomy (PRK) in keratoconus-suspect patients with that in patients with normal corneal topography. SETTING:Gimbel Eye Centre, Calgary, Alberta, Canada. METHOD:In a retrospective study, 3 patients (5 eyes) with unusually shaped corneal topography bef...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(99)00234-5

    authors: Sun R,Gimbel HV,Kaye GB

    更新日期:1999-11-01 00:00:00

  • Price graft-over-host technique to manage positive pressure during penetrating keratoplasty.

    abstract::Intraoperative positive pressure with resulting iris and lens prolapse can pose a difficult scenario during penetrating keratoplasty. In the Price graft-over-host technique, the graft is sutured across the trephinated host cornea, which maintains a formed anterior chamber and thus avoids intraoperative complications. ...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(98)80123-5

    authors: Loden JC,Price FW Jr

    更新日期:1998-06-01 00:00:00

  • Effect of poly(ethylene glycol) graft polymerization of poly(methyl methacrylate) on cell adhesion. In vitro and in vivo study.

    abstract:PURPOSE:To investigate the effect of surface modification of poly(methyl methacrylate) (PMMA) by poly(ethylene glycol) (PEG) grafting on cell adhesion. SETTING:Department of Ophthalmology, Seoul National University Hospital, Seoul, Korea. METHODS:The PMMA surface was oxidized with ozone, and PEG acrylate was then gra...

    journal_title:Journal of cataract and refractive surgery

    pub_type: 杂志文章

    doi:10.1016/s0886-3350(00)00701-x

    authors: Kim MK,Park IS,Park HD,Wee WR,Lee JH,Park KD,Kim SH,Kim YH

    更新日期:2001-05-01 00:00:00