Unified bundling and registration of brain white matter fibers.

Abstract:

:Magnetic resonance diffusion tensor imaging is being widely used to reconstruct brain white matter fiber tracts. To characterize structural properties of the tracts, reconstructed fibers are often grouped into bundles that correspond to coherent anatomic structures. For further group analysis of fiber bundles, it is desirable that corresponding bundles from different studies are coregistered. To address these needs simultaneously, a unified fiber bundling and registration (UFIBRE) framework is proposed in this work. The framework is based on maximizing a posteriori Bayesian probabilities using an expectation maximization algorithm. Given a set of segmented template bundles and a whole-brain target fiber set, the UFIBRE algorithm optimally bundles the target fibers and registers them with the template. The bundling component in the UFIBRE algorithm simplifies fiber-based registration into bundle-to-bundle registration, and the registration component in turn guides the bundling process to find bundles consistent with the template. Experiments with in vivo data demonstrate that the estimated bundles have an approximately 80% consistency with ground truth and the root mean square error between their bundle medial axes is less than one voxel. The proposed algorithm is highly efficient, offering potential routine use for group analysis of white matter fibers.

journal_name

IEEE Trans Med Imaging

authors

Xu Q,Anderson AW,Gore JC,Ding Z

doi

10.1109/TMI.2009.2016337

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

1399-411

issue

9

eissn

0278-0062

issn

1558-254X

journal_volume

28

pub_type

杂志文章
  • Spatially adaptive mixture modeling for analysis of FMRI time series.

    abstract::Within-subject analysis in fMRI essentially addresses two problems, the detection of brain regions eliciting evoked activity and the estimation of the underlying dynamics. In Makni et aL, 2005 and Makni et aL, 2008, a detection-estimation framework has been proposed to tackle these problems jointly, since they are con...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2010.2042064

    authors: Vincent T,Risser L,Ciuciu P

    更新日期:2010-04-01 00:00:00

  • Automated Chest X-Ray Screening: Can Lung Region Symmetry Help Detect Pulmonary Abnormalities?

    abstract::Our primary motivator is the need for screening HIV+ populations in resource-constrained regions for exposure to Tuberculosis, using posteroanterior chest radiographs (CXRs). The proposed method is motivated by the observation that radiological examinations routinely conduct bilateral comparisons of the lung field. In...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2775636

    authors: Santosh KC,Antani S

    更新日期:2018-05-01 00:00:00

  • Reducing the effects of scattered photons in X-ray projection imaging.

    abstract::An iterative algorithm is introduced which can compute and subtract the scatter bias. It is assumed that the scatter-free image is spatially bounded and anything outside the boundary is the result of recorded scattered photons. This information and the fact that the scatter distribution does not have appreciable high-...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.20362

    authors: Fahimi H,Macovski A

    更新日期:1989-01-01 00:00:00

  • Improved Low-Count Quantitative PET Reconstruction With an Iterative Neural Network.

    abstract::Image reconstruction in low-count PET is particularly challenging because gammas from natural radioactivity in Lu-based crystals cause high random fractions that lower the measurement signal-to-noise-ratio (SNR). In model-based image reconstruction (MBIR), using more iterations of an unregularized method may increase ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2020.2998480

    authors: Lim H,Chun IY,Dewaraja YK,Fessler JA

    更新日期:2020-11-01 00:00:00

  • Efficient Lattice Boltzmann Solver for Patient-Specific Radiofrequency Ablation of Hepatic Tumors.

    abstract::Radiofrequency ablation (RFA) is an established treatment for liver cancer when resection is not possible. Yet, its optimal delivery is challenged by the presence of large blood vessels and the time-varying thermal conductivity of biological tissue. Incomplete treatment and an increased risk of recurrence are therefor...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2406575

    authors: Audigier C,Mansi T,Delingette H,Rapaka S,Mihalef V,Carnegie D,Boctor E,Choti M,Kamen A,Ayache N,Comaniciu D

    更新日期:2015-07-01 00:00:00

  • Learning-based deformable registration of MR brain images.

    abstract::This paper presents a learning-based method for deformable registration of magnetic resonance (MR) brain images. There are two novelties in the proposed registration method. First, a set of best-scale geometric features are selected for each point in the brain, in order to facilitate correspondence detection during th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2006.879320

    authors: Wu G,Qi F,Shen D

    更新日期:2006-09-01 00:00:00

  • Image Registration Based on Low Rank Matrix: Rank-Regularized SSD.

    abstract::Similarity measure is a main core of image registration algorithms. Spatially varying intensity distortion is an important challenge, which affects the performance of similarity measures. Correlation among the pixels is the main characteristic of this distortion. Similarity measures such as sum-of-squared-differences ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2744663

    authors: Ghaffari A,Fatemizadeh E

    更新日期:2018-01-01 00:00:00

  • Robust Unmixing of Dynamic Sequences Using Regions of Interest.

    abstract::In dynamic planar imaging, extraction of signals specific to structures is complicated by structures superposition. Due to overlapping, signals extraction with classic regions of interest (ROIs) methods suffers from inaccuracy, as extracted signals are a mixture of targeted signals. Partial volume effect raises the sa...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2759661

    authors: Filippi M,Desvignes M,Moisan E

    更新日期:2018-01-01 00:00:00

  • Efficient Compressed Sensing SENSE pMRI Reconstruction With Joint Sparsity Promotion.

    abstract::The theory and techniques of compressed sensing (CS) have shown their potential as a breakthrough in accelerating k-space data acquisition for parallel magnetic resonance imaging (pMRI). However, the performance of CS reconstruction models in pMRI has not been fully maximized, and CS recovery guarantees for pMRI are l...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2474383

    authors: Chun IY,Adcock B,Talavage TM

    更新日期:2016-01-01 00:00:00

  • NMR velocity-selective excitation composites for flow and motion imaging and suppression of static tissue signal.

    abstract::We propose a technique aimed at increasing the sensitivity of magnetic resonance imaging (MRI) measurements to the signal from moving material. The technique is formulated within the framework of a velocity phase-encoding strategy. The salient new feature of the protocol is the application of an excitation pulse, foll...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.1987.4307814

    authors: Moran PR,Saloner D,Tsui BW

    更新日期:1987-01-01 00:00:00

  • Accelerated Parameter Mapping of Multiple-Echo Gradient-Echo Data Using Model-Based Iterative Reconstruction.

    abstract::A new reconstruction method, coined MIRAGE, is presented for accurate, fast, and robust parameter mapping of multiple-echo gradient-echo (MEGE) imaging, the basis sequence of novel quantitative magnetic resonance imaging techniques such as water content and susceptibility mapping. Assuming that the temporal signal can...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2017.2771504

    authors: Zimmermann M,Abbas Z,Dzieciol K,Shah NJ

    更新日期:2018-02-01 00:00:00

  • MRI Meets MPI: a bimodal MPI-MRI tomograph.

    abstract::While magnetic particle imaging (MPI) constitutes a novel biomedical imaging technique for tracking superparamagnetic nanoparticles in vivo, unlike magnetic resonance imaging (MRI), it cannot provide anatomical background information. Until now these two modalities have been performed in separate scanners and image co...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2327515

    authors: Vogel P,Lother S,Rückert MA,Kullmann WH,Jakob PM,Fidler F,Behr VC

    更新日期:2014-10-01 00:00:00

  • A Magnetic Resonance Imaging Surface Coil Transceiver Employing a Metasurface for 1.5T Applications.

    abstract::A capacitive impedance metasurface combined with a transceiver coil to improve the radio frequency magnetic field for 1.5T magnetic resonance imaging applications is presented. The novel transceiver provides localized enhancement in magnetic flux density when compared to a transceiver coil alone by incorporating an el...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2019.2942194

    authors: Issa I,Ford KL,Rao M,Wild JM

    更新日期:2020-04-01 00:00:00

  • Precise robot-assisted guide positioning for distal locking of intramedullary nails.

    abstract::This paper presents a novel image-guided robot-based system to assist orthopedic surgeons in performing distal locking of long bone intramedullary nails. The system consists of a bone-mounted miniature robot fitted with a drill guide that provides rigid mechanical guidance for hand-held drilling of the distal screws' ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.844922

    authors: Yaniv Z,Joskowicz L

    更新日期:2005-05-01 00:00:00

  • Hot spot detection based on feature space representation of visual search.

    abstract::This paper presents a new framework for capturing intrinsic visual search behavior of different observers in image understanding by analysing saccadic eye movements in feature space. The method is based on the information theory for identifying salient image features based on which visual search is performed. We demon...

    journal_title:IEEE transactions on medical imaging

    pub_type: 临床试验,杂志文章

    doi:10.1109/TMI.2003.816959

    authors: Hu XP,Dempere-Marco L,Yang GZ

    更新日期:2003-09-01 00:00:00

  • A Sparse Non-Negative Matrix Factorization Framework for Identifying Functional Units of Tongue Behavior From MRI.

    abstract::Muscle coordination patterns of lingual behaviors are synergies generated by deforming local muscle groups in a variety of ways. Functional units are functional muscle groups of local structural elements within the tongue that compress, expand, and move in a cohesive and consistent manner. Identifying the functional u...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2018.2870939

    authors: Jonghye Woo,Prince JL,Stone M,Fangxu Xing,Gomez AD,Green JR,Hartnick CJ,Brady TJ,Reese TG,Wedeen VJ,El Fakhri G

    更新日期:2019-03-01 00:00:00

  • An Inverse Problems Approach to MR-EPT Image Reconstruction.

    abstract::Magnetic Resonance-Electrical Properties Tomography (MR-EPT) is an imaging modality that maps the spatial distribution of the electrical conductivity and permittivity using standard MRI systems. The presence of a body within the scanner alters the RF field, and by mapping these alterations it is possible to recover th...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2466082

    authors: Borsic A,Perreard I,Mahara A,Halter RJ

    更新日期:2016-01-01 00:00:00

  • Analysis of noise properties of a class of exact methods of inverting the 2-D exponential radon transform [SPECT application].

    abstract::A general approach that the authors proposed elsewhere reveals the intrinsic relationship among methods for inversion of the 2-D exponential Radon transform described by Bellini et al. (1979), by Tretiak and Metz (1980), by Hawkins et al. (1988), and by Inouye et al. (1989). Moreover, the authors' approach provides an...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476107

    authors: Pan X,Metz CE

    更新日期:1995-01-01 00:00:00

  • Unification of the inverse radon transform in odd and even dimensions.

    abstract::It is well known that the inverse radon transform exists in two forms for odd and even dimension functions, respectively. This note shows that these formulas become zero when the dimension requirement is violated, which results in a simple unified formula for the inverse radon transform of arbitrary dimensions. ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.476117

    authors: Liang ZP

    更新日期:1995-01-01 00:00:00

  • Digital flashing tomosynthesis: a promising technique for angiocardiographic screening.

    abstract::A system for digital flashing tomosynthesis (DFTS) consists of four ECG-gated simultaneously flashed X-ray tubes, a 14-in image intensifier, a unit for digital subtraction angiography (DSA), a PC-hosted transputer network for three-dimensional (3-D) reconstruction as well as for quantitative coronary angiography and v...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.232261

    authors: Stiel GM,Stiel LG,Klotz E,Nienaber CA

    更新日期:1993-01-01 00:00:00

  • Motion estimation of skeletonized angiographic images using elastic registration.

    abstract::An approach for estimating the motion of arteries in digital angiographic image sequences is proposed. Binary skeleton images are registered using an elastic registration algorithm in order to estimate the motion of the corresponding arteries. This algorithm operates recursively on the skeleton images by considering a...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/42.310876

    authors: Tom BS,Efstratiadis SN,Katsaggelos AK

    更新日期:1994-01-01 00:00:00

  • Sparse patch-based label propagation for accurate prostate localization in CT images.

    abstract::In this paper, we propose a new prostate computed tomography (CT) segmentation method for image guided radiation therapy. The main contributions of our method lie in the following aspects. 1) Instead of using voxel intensity information alone, patch-based representation in the discriminative feature space with logisti...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2012.2230018

    authors: Liao S,Gao Y,Lian J,Shen D

    更新日期:2013-02-01 00:00:00

  • Accuracy of the morphology enabled dipole inversion (MEDI) algorithm for quantitative susceptibility mapping in MRI.

    abstract::Determining the susceptibility distribution from the magnetic field measured in a magnetic resonance (MR) scanner is an ill-posed inverse problem, because of the presence of zeroes in the convolution kernel in the forward problem. An algorithm called morphology enabled dipole inversion (MEDI), which incorporates spati...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2182523

    authors: Liu T,Xu W,Spincemaille P,Avestimehr AS,Wang Y

    更新日期:2012-03-01 00:00:00

  • Multi-channel microstrip transceiver arrays using harmonics for high field MR imaging in humans.

    abstract::Radio-frequency (RF) transceiver array design using primary and higher order harmonics for in vivo parallel magnetic resonance imaging imaging (MRI) and spectroscopic imaging is proposed. The improved electromagnetic decoupling performance, unique magnetic field distributions and high-frequency operation capabilities ...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2166273

    authors: Wu B,Wang C,Lu J,Pang Y,Nelson SJ,Vigneron DB,Zhang X

    更新日期:2012-02-01 00:00:00

  • Compressive Deconvolution in Medical Ultrasound Imaging.

    abstract::The interest of compressive sampling in ultrasound imaging has been recently extensively evaluated by several research teams. Following the different application setups, it has been shown that the RF data may be reconstructed from a small number of measurements and/or using a reduced number of ultrasound pulse emissio...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2015.2493241

    authors: Chen Z,Basarab A,Kouamé D

    更新日期:2016-03-01 00:00:00

  • Imaging of cardiac movement using ratiometric and nonratiometric optical mapping: effects of ischemia and 2, 3-butaneodione monoxime.

    abstract::Transmembrane voltage-sensitive fluorescent dyes are used to study electrical activity in hearts. Green and red fluorescence emissions from di-4-ANEPPS excited with 488 nm light indicate both transmembrane voltage changes and heart movement. We have previously shown that the ratio, green fluorescence divided by red fl...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2005.861019

    authors: Himel HD 4th,Knisley SB

    更新日期:2006-01-01 00:00:00

  • Total variation regularization for fMRI-based prediction of behavior.

    abstract::While medical imaging typically provides massive amounts of data, the extraction of relevant information for predictive diagnosis remains a difficult challenge. Functional magnetic resonance imaging (fMRI) data, that provide an indirect measure of task-related or spontaneous neuronal activity, are classically analyzed...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2011.2113378

    authors: Michel V,Gramfort A,Varoquaux G,Eger E,Thirion B

    更新日期:2011-07-01 00:00:00

  • Improved watershed transform for medical image segmentation using prior information.

    abstract::The watershed transform has interesting properties that make it useful for many different image segmentation applications: it is simple and intuitive, can be parallelized, and always produces a complete division of the image. However, when applied to medical image analysis, it has important drawbacks (oversegmentation...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2004.824224

    authors: Grau V,Mewes AU,Alcañiz M,Kikinis R,Warfield SK

    更新日期:2004-04-01 00:00:00

  • Multi-dimensional tumor detection in automated whole breast ultrasound using topographic watershed.

    abstract::Automated whole breast ultrasound (ABUS) is becoming a popular screening modality for whole breast examination. Compared to conventional handheld ultrasound, ABUS achieves operator-independent and is feasible for mass screening. However, reviewing hundreds of slices in an ABUS image volume is time-consuming. A compute...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/TMI.2014.2315206

    authors: Lo CM,Chen RT,Chang YC,Yang YW,Hung MJ,Huang CS,Chang RF

    更新日期:2014-07-01 00:00:00

  • The hypervolume under the ROC hypersurface of "near-guessing" and "near-perfect" observers in N-class classification tasks.

    abstract::We express the performance of the N-class "guessing" observer in terms of the N2-N conditional probabilities which make up an N-class receiver operating characteristic (ROC) space, in a formulation in which sensitivities are eliminated in constructing the ROC space (equivalent to using false-negative fraction and fals...

    journal_title:IEEE transactions on medical imaging

    pub_type: 杂志文章

    doi:10.1109/tmi.2004.841227

    authors: Edwards DC,Metz CE,Nishikawa RM

    更新日期:2005-03-01 00:00:00