Abstract:
:An electromagnetic-based tracking and navigation system was evaluated for interventional radiology. The electromagnetic tracking system (CAPPA IRAD EMT, CASinnovations, Erlangen, Germany) was used for real-time monitoring of punctures of the lumbar facet joints and intervertebral disks in a spine phantom, three pig cadavers and three anaesthesized pigs. Therefore, pre-interventional computed tomography (CT) datasets were transferred to the navigation system and puncture trajectories were planned. A coaxial needle was advanced along the trajectories while the position of the needle tip was monitored in real time. After puncture tracts were marked with pieces of wire another CT examination was performed and distances between wires and anatomical targets were measured. Performing punctures of the facet joints mean needle positioning errors were 0.4 +/- 0.8 mm in the spine phantom, 2.8 +/- 2.1 mm ex vivo and 3.0 +/- 2.0 mm in vivo with mean length of the puncture tract of 54.0 +/- 10.4 mm (phantom), 51.6 +/- 12.6 mm (ex vivo) and 50.9 +/- 17.6 mm (in vivo). At first attempt, intervertebral discs were successfully punctured in 15/15 in the phantom study, in 12/15 in the ex-vivo study and 14/15 in the in-vivo study, respectively. Immobilization of the patient and optimal positioning of the field generator are essential to achieve a high accuracy of needle placement in a clinical CT setting.
journal_name
Eur Radioljournal_title
European radiologyauthors
Bruners P,Penzkofer T,Nagel M,Elfring R,Gronloh N,Schmitz-Rode T,Günther RW,Mahnken AHdoi
10.1007/s00330-008-1227-zsubject
Has Abstractpub_date
2009-04-01 00:00:00pages
990-4issue
4eissn
0938-7994issn
1432-1084journal_volume
19pub_type
杂志文章abstract:OBJECTIVE:To evaluate the impact of magnetic resonance neurography (MRN) on diagnostic thinking and therapeutic choices in patients with suspected peripheral neuropathy. METHODS:IRB approval was obtained for this HIPAA-compliant study. Questionnaires were administered to six surgeons regarding the diagnosis and treatm...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3958-y
更新日期:2016-05-01 00:00:00
abstract::In this study 15 patients with clinical findings and positive cerebrospinal fluid analyses for tuberculous meningitis were evaluated with magnetic resonance imaging (MRI). Tuberculous meningitis was diagnosed in 11 cases when thick meningeal enhancement was present after intravenous injection of gadolinium diethylenet...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/BF00180618
更新日期:1996-01-01 00:00:00
abstract:OBJECTIVES:Given the frequency of abusive fractures among infants, and the lack of research and or evidence for the phases of fracture healing seen in this age group, this study aims to describe a timetable of radiological features of fracture healing among infants in the first months of life. METHODS:We completed a r...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4569-y
更新日期:2017-05-01 00:00:00
abstract:BACKGROUND:The prognosis of patients with non-small cell lung cancer (NSCLC) is important, as patients with resectable disease and poor prognostic variables might benefit from neoadjuvant therapy. The goal of this study is to evaluate SUVmax, SUVmax ratio, CT volume (CTvol), metabolic tumour volume (MTV) and total lesi...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3754-8
更新日期:2015-11-01 00:00:00
abstract::The aim of this study was to evaluate the potential of multislice CT angiography (CTA) in detecting hemodynamically significant (> or =70%) lesions of lower extremity inflow and runoff arteries. Fifty patients (42 men, 8 women; mean age 68 years) with peripheral arterial occlusive disease underwent multislice spiral C...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-004-2289-1
更新日期:2004-09-01 00:00:00
abstract:PURPOSE:The purpose of this study was to compare three different biopsy devices on false-negative and underestimation rates in MR-guided, vacuum-assisted breast biopsy (VABB) of MRI-only lesions. METHODS:This retrospective, single-center study was IRB-approved. Informed consent was waived. 467 consecutive patients und...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4267-9
更新日期:2016-11-01 00:00:00
abstract::We evaluated an algorithm for automatic selection of the cardiac phase with the least motion for image reconstruction at coronary computed tomography (CT) angiography (CCTA). We analyzed data of 100 patients (49 female, mean age 59 years) who had undergone retrospectively ECG-gated CCTA. Two experienced observers visu...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1368-8
更新日期:2009-08-01 00:00:00
abstract::Heterotropic mesenteric ossification is a rare entity. Only a few cases have been described in the literature. We report a case of heterotropic mesenteric ossification in a patient who underwent several laparotomies, after suffering from multiple gunshot wounds. We discuss the radiographic findings of this disease tha...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-004-2464-4
更新日期:2005-01-01 00:00:00
abstract:OBJECTIVE:To retrospectively compare semi-automated and manual volume measurements of malignant liver tumours and inter- and intra-observer variability using commercially available software. METHODS:This study was performed on 60 consecutive patients with untreated liver metastases (30) and HCCs (30), i.e. 92 lesions ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-2013-2
更新日期:2011-05-01 00:00:00
abstract::The purpose of our animal study was to evaluate a new computed tomography (CT) subtraction technique for visualization of perfusion defects within the lung parenchyma in subsegmental pulmonary embolism (PE). Seven healthy pigs were entered into a prospective trial. Acute PE was artificially induced by fresh clot mater...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-005-2718-9
更新日期:2005-07-01 00:00:00
abstract::To assess the practical feasibility and effectiveness of real-time magnetic resonance (MR) temperature monitoring for the radiofrequency (RF) ablation of liver tumours in a clinical setting, nine patients (aged 49-87 years, five men and four women) with one malignant tumour (14-50 mm, eight hepatocellular carcinomas a...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-009-1532-1
更新日期:2010-01-01 00:00:00
abstract:OBJECTIVES:To date, there is no approved second-line treatment for patients dismissing sorafenib or ineligible for this treatment, so it would be useful to find an effective alternative treatment option. The aim of our study was to evaluate safety, feasibility and effectiveness of transarterial chemoembolisation with d...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5692-8
更新日期:2019-03-01 00:00:00
abstract:OBJECTIVES:To verify the association between EGFR status and clinical response to microwave ablation (MWA) and survival. METHODS:NSCLC patients with known EGFR status and treated with MWA in combination with chemotherapy were retrospectively enrolled in the study. RESULTS:A total of 61 patients were recruited. EGFR m...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4474-4
更新日期:2017-04-01 00:00:00
abstract:OBJECTIVES:To assess the risk of lung cancer and specific mortality rate in patients with and without solitary pulmonary nodules (SPN) on chest radiograph and CT. METHODS:This prospective study included 16,078 patients ≥35 years old (893 of them had an SPN detected with either chest radiograph or CT) and 15,185 withou...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-015-3775-3
更新日期:2015-12-01 00:00:00
abstract::CT-guided procedures remain an important tool for diagnosis and tissue acquisition for primary diagnosis and molecular/tissue correlation. New imaging devices such as MDCT and PET/CT will improve diagnosis but percutaneous procedures will be needed to confirm and support new molecular and DNA treatments. Coagulopathic...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s10406-005-0130-9
更新日期:2005-11-01 00:00:00
abstract:OBJECTIVES:To evaluate whether post-contrast cone-beam breast CT (CBBCT) alone is comparable to the current standard of combined pre- and post-contrast CBBCT regarding diagnostic accuracy and superior regarding radiation exposure. MATERIAL AND METHODS:This study included 49 women (61 breasts) with median age 57.9 year...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5854-8
更新日期:2019-06-01 00:00:00
abstract::Metastases of the spine occur in the spinal cord, dura extramedullary, epidural space, and vertebral bodies. Imaging modalities can be used to evaluate patient symptoms, screen and detect lesions, assess localization and the compartments involved (extradural, epidural, subdural, and paraspinal), and suggest therapeuti...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s00330-004-2627-3
更新日期:2005-03-01 00:00:00
abstract::Increasing beam energies are well established as a radiation dose-reducing tool in diagnostic radiology. This has led to useful recommendations by the Commission of European Communities (CEC) for appropriate kVp values to be employed for a variety of examinations. The current work tests the hypothesis that kVp levels ...
journal_title:European radiology
pub_type: 临床试验,杂志文章,随机对照试验
doi:10.1007/s00330-002-1810-7
更新日期:2003-08-01 00:00:00
abstract::Small bowel obstruction is a leading cause of acute surgical admissions for abdominal pain. There is an increasing tendency for initial conservative management rather than immediate operative intervention, as a proportion of cases will resolve spontaneously. This has resulted in a growing reliance on radiological inve...
journal_title:European radiology
pub_type: 杂志文章,评审
doi:10.1007/s003300100882
更新日期:2001-01-01 00:00:00
abstract:OBJECTIVE:Quantification of tumour burden in oncology requires accurate and reproducible evaluation. The current standard is RECIST measurement with its inherent disadvantages. Volumetric analysis is an alternative for therapy monitoring. The aim of this study was to evaluate the feasibility of volumetric analysis of l...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1966-5
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVES:The purpose of this study was to retrospectively assess the incidence of bowel wall oedema on computed tomography (CT) in patients with renal cell carcinoma (RCC) treated with sunitinib, and to investigate its association with diarrhoea. METHODS:We conducted a retrospective analysis of all RCC patients trea...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-014-3389-1
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:To systematically review the literature on the Bosniak classification system in CT to determine its diagnostic performance to diagnose malignant cystic lesions and the prevalence of malignancy in Bosniak categories. METHODS:A predefined database search was performed from 1 January 1986 to 18 January 2016. Tw...
journal_title:European radiology
pub_type: 杂志文章,meta分析,评审
doi:10.1007/s00330-016-4631-9
更新日期:2017-06-01 00:00:00
abstract:OBJECTIVES:To evaluate the outcomes of re-exposure to low-osmolar iodinated contrast medium (LOCM) in patients with a history of moderate-to-severe hypersensitivity reaction (HSR). METHODS:We retrospectively evaluated a cohort comprising all subjects satisfying the following conditions at 11 centres: (1) experienced a...
journal_title:European radiology
pub_type: 杂志文章,多中心研究
doi:10.1007/s00330-016-4682-y
更新日期:2017-07-01 00:00:00
abstract::The aim of this study was to develop an endorectal MRI strategy for prostatic cancer. We evaluated the MR images from 44 consecutive prostatic cancer patients treated by radical prostatectomy. Each sequence from every examination was assessed separately with a specific tumor map drawn. Tumor localization, capsular pen...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300000598
更新日期:2001-01-01 00:00:00
abstract::The purpose of this article is to report four patients with massive pulmonary embolism treated with percutaneous catheter and guidewire fragmentation and local administration of recombinant tissue plasminogen activator (r-TPA). Four patients with massive pulmonary embolism initially underwent pulmonary angiography. Th...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050776
更新日期:1999-01-01 00:00:00
abstract::This paper evaluates the management of 31 patients with bile leaks identified over a 7-year period. Leaks complicated cholecystectomy in 19 patients (11 laparoscopic, 8 open), interventional procedures in 10 (including surgery in 1), trauma in one and was spontaneous in one case. Confirmation of the diagnosis typicall...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s003300050595
更新日期:1998-01-01 00:00:00
abstract:OBJECTIVE:Medical imaging acquired for clinical purposes can have several legitimate secondary uses in research projects and teaching libraries. No commonly accepted solution for anonymising these images exists because the amount of personal data that should be preserved varies case by case. Our objective is to provide...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-010-1745-3
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVES:To evaluate the safety and efficacy of balloon-occluded transcatheter arterial chemoembolization (B-TACE) for the treatment of HCC refractory to conventional TACE (C-TACE). METHODS:This single-center retrospective analysis included 60 consecutive patients who underwent B-TACE (mean age, 61.4 years; male:fem...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-020-06911-9
更新日期:2020-10-01 00:00:00
abstract:PURPOSE:To describe the normal linear measurements of the skull (bi-parietal diameter and occipito-frontal diameter) and intracranial volumes (ventricular volume, brain parenchymal volume, extra-axial volume and total intra-cranial volume) in normal fetuses. MATERIALS AND METHODS:We recruited pregnant women from low-r...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-018-5938-5
更新日期:2019-07-01 00:00:00
abstract:OBJECTIVES:To apply an easy-to-assemble phantom substitute for human prostates in T2-weighted magnetic resonance imaging (T2WI), diffusion-weighted imaging (DWI) and 3D magnetic resonance spectroscopy (MRS). METHODS:Kiwi fruit were fixed with gel hot and cold compress packs on two plastic nursery pots, separated by a ...
journal_title:European radiology
pub_type: 杂志文章
doi:10.1007/s00330-016-4706-7
更新日期:2017-08-01 00:00:00