Postanalytical external quality assessment of urine albumin in primary health care: an international survey.

Abstract:

BACKGROUND:Microalbuminuria (MA) is recognized as an important risk factor for cardiovascular and renal complications in diabetes. We sought to evaluate how screening for MA is conducted and how urine albumin (UA) results are interpreted in primary care internationally. METHODS:General practitioners (GPs) received a case history-based questionnaire depicting a male type 2 diabetes patient in whom UA testing had not been performed. Questions were related to type of urine sample used for UA testing, need for a repeat test, whether UA testing was performed in the office laboratory, and what changes in UA results were considered clinically important [critical difference (CD)]. Participants received national benchmarking feedback reports. RESULTS:We included 2078 GPs from 9 European countries. Spot urine samples were used most commonly for first time office-based testing, whereas timed collections were used to a larger extent for hospital-based repeat tests. Repeat tests were requested by 45%-77% of GPs if the first test was positive. Four different measurement units were used by 70% of participants in estimating clinically important changes in albumin values. Stated CDs varied considerably among GPs, with similar variations in each country. A median CD of 33% was considered clinically important for both improvement and deterioration in MA, corresponding to an achievable analytical imprecision of 14%, when UA is reported as an albumin/creatinine ratio. CONCLUSIONS:Guidelines on diagnosing MA are followed only partially, and should be made more practicable, addressing issues such as type of samples, measurement units, and repeat tests.

journal_name

Clin Chem

journal_title

Clinical chemistry

authors

Aakre KM,Thue G,Subramaniam-Haavik S,Bukve T,Morris H,Müller M,Lovrencic MV,Plum I,Kallion K,Aab A,Kutt M,Gillery P,Schneider N,Horvath AR,Onody R,Oosterhuis W,Ricos C,Perich C,Nordin G,Sandberg S

doi

10.1373/clinchem.2007.100917

subject

Has Abstract

pub_date

2008-10-01 00:00:00

pages

1630-6

issue

10

eissn

0009-9147

issn

1530-8561

pii

clinchem.2007.100917

journal_volume

54

pub_type

杂志文章
  • Estimating fat in feces by near-infrared reflectance spectroscopy.

    abstract::We describe use of near-infrared reflectance spectroscopy (NIRRS) to estimate the amount of fat in feces, for diagnosis of steatorrhea. After sample homogenization, the spectrum of the fecal homogenate is scanned over the near-infrared region. Assay of 94 samples of feces having a known concentration of fat showed the...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Koumantakis G,Radcliff FJ

    更新日期:1987-04-01 00:00:00

  • Chromogenic ionophore-based methods for spectrophotometric assay of sodium and potassium in serum and plasma.

    abstract::We report spectrophotometric methods for quantifying sodium and potassium in serum and plasma without sample pretreatment or solvent-extraction steps. The methods are based on novel chromogenic ionophores characterized by molecular structures highly preorganized for binding, which result in exceptionally high sensitiv...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kumar A,Chapoteau E,Czech BP,Gebauer CR,Chimenti MZ,Raimondo O

    更新日期:1988-09-01 00:00:00

  • Enzyme conversion immunoassay for determining total homocysteine in plasma or serum.

    abstract::A rapid and precise immunoassay for quantification of total homocysteine in blood samples is presented. The method avoids the use of radioisotopes and chromatographic separations and relies on enzymatic conversion of homocysteine to S-adenosyl-L-homocysteine, followed by quantification of S-adenosyl-L-homocysteine by ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Frantzen F,Faaren AL,Alfheim I,Nordhei AK

    更新日期:1998-02-01 00:00:00

  • Aluminum determined in plasma and urine by atomic absorption spectroscopy with a transversely heated graphite atomizer furnace.

    abstract::We compared a stabilized-temperature L'vov platform furnace containing an end-heated graphite atomizer (HGA) and transverse Zeeman background-correction system with a side-heated furnace system (transversely heated graphite atomizer; THGA) containing a longitudinal Zeeman background-correction system for the determina...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Bradley C,Leung FY

    更新日期:1994-03-01 00:00:00

  • Relative increase in creatine kinase MB isoenzyme during reperfusion after myocardial infarction is method dependent.

    abstract::We compared relative increases in creatine kinase (EC 2.7.3.2) MB isoenzyme (CK-MB) after reperfusion in myocardial infarction for four popular methods: electrophoresis, immunoinhibition, the "Magic Lite" (Ciba-Corning) system, and the Stratus (Dade). In a method comparison study, we confirmed that all four methods co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Christenson RH,Clemmensen P,Ohman EM,Toffaletti J,Silverman LM,Grande P,Vollmer RT,Wagner GS

    更新日期:1990-08-01 00:00:00

  • Gene probes: application to prenatal and postnatal diagnosis of genetic disease.

    abstract::Gene probes can now be used to detect a variety of mutations that produce single-gene disorders. In present clinical practice, restriction endonuclease analysis is used for the prenatal diagnosis of sickle cell anemia, alpha-thalassemia, and beta-thalassemia. Direct detection of the mutation is possible in alpha-thala...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kazazian HH Jr

    更新日期:1985-09-01 00:00:00

  • Performance of a single assay for both type III and type VI TMPRSS2:ERG fusions in noninvasive prediction of prostate biopsy outcome.

    abstract:BACKGROUND:TMPRSS2:ERG fusions are promising prostate cancer biomarkers. Because they can occur in multiple forms in a single cancer specimen, we developed a quantitative PCR test that detects both type III and type VI TMPRSS2:ERG fusions. The assay is quantified from a standard curve determined with a plasmid-cloned t...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.108845

    authors: Clark JP,Munson KW,Gu JW,Lamparska-Kupsik K,Chan KG,Yoshida JS,Kawachi MH,Crocitto LE,Wilson TG,Feng Z,Smith SS

    更新日期:2008-12-01 00:00:00

  • Energy-dispersive x-ray fluorescence spectroscopy and inductively coupled plasma emission spectrometry evaluated for multielement analysis in complex biological matrices.

    abstract::Energy-dispersive x-ray spectroscopy and inductively coupled plasma emission spectrometry were evaluated as methods for routine multielement analysis of biological material. Standard samples included Standard Reference Materials (National Bureau of Standards), compounded mixtures, and supplements that provided a wide ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Irons RD,Schenk EA,Giauque RD

    更新日期:1976-12-01 00:00:00

  • Multianalyte microspot immunoassay--microanalytical "compact disk" of the future.

    abstract::Throughout the 1970s, controversy centered both on immunoassay "sensitivity" per se and on the relative sensitivities of labeled antibody (Ab) and labeled analyte methods. Our theoretical studies revealed that RIA sensitivities could be surpassed only by the use of very high-specificity nonisotopic labels in "noncompe...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:

    authors: Ekins RP,Chu FW

    更新日期:1991-11-01 00:00:00

  • An interlaboratory study of measurement of aspartate aminotransferase activity with use of purified enzyme materials.

    abstract::The Center for Disease Control (CDC), the New York State Department of Health (NYSDH), the College of American Pathologists, and 23 manufacturers of diagnostic products participated in an interlaboratory study of aspartate aminotransferase (EC 2.6.1.1) methodologies. Six different lyophilized materials were prepared a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Burtis CA,Sampson EJ,Bayse DD,McKneally SS,Whitner VS

    更新日期:1978-06-01 00:00:00

  • Two-dimensional electrophoretic patterns of proteins of normal mucosa, polyps, and carcinomas of the large intestine.

    abstract::Two-dimensional protein maps of biopsies from normal mucosa, tubular adenomas (polyps), and colonic carcinomas in humans have been studied in order to obtain information on the possible precancerous role of intestinal polyps. The maps are complex and several hundred protein spots are seen after staining with Coomassie...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Thorsrud AK,Vatn MH,Jellum E

    更新日期:1982-04-01 00:00:00

  • Plasma microRNA-122 as a biomarker for viral-, alcohol-, and chemical-related hepatic diseases.

    abstract:BACKGROUND:The liver is frequently subject to insult because of viral infection, alcohol abuse, or toxic chemical exposure. Extensive research has been conducted to identify blood markers that can better discern liver damage, but little progress has been achieved in clinical practice. Recently, circulating microRNAs (m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2010.147850

    authors: Zhang Y,Jia Y,Zheng R,Guo Y,Wang Y,Guo H,Fei M,Sun S

    更新日期:2010-12-01 00:00:00

  • Direct solid-phase fluoroenzymeimmunoassay of 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide in urine.

    abstract::A competitive solid-phase fluoroenzymeimmunoassay has been developed for rapidly measuring 5 beta-pregnane-3 alpha, 20 alpha-diol-3 alpha-glucuronide (Pd-3G) directly in diluted specimens of pre-breakfast urine. The assay involves use of an antiserum to Pd-3G and enzyme-labeled antigen prepared by chemically linking g...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Shah H,Saranko AM,Härkönen M,Adlercreutz H

    更新日期:1984-02-01 00:00:00

  • Virus-coated layer-by-layer colloids as a multiplex suspension array for the detection and quantification of virus-specific antibodies.

    abstract:BACKGROUND:Suspension array technology has surpassed ELISA for automated, simultaneous detection and quantification of soluble biomarkers such as virus-specific antibodies. We describe assays in which antigens are attached to a lipid bilayer surrounding color-coded particles. METHODS:We used layer-by-layer technology ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.065789

    authors: Toellner L,Fischlechner M,Ferko B,Grabherr RM,Donath E

    更新日期:2006-08-01 00:00:00

  • Quadruplex genotyping of F5, F2, and MTHFR variants in a single closed tube by high-resolution amplicon melting.

    abstract:BACKGROUND:Multiplexed amplicon melting is a closed-tube method for genotyping that does not require probes, real-time analysis, asymmetric PCR, or allele-specific PCR; however, correct differentiation of homozygous mutant and wild-type samples by melting temperature (T(m)) analysis requires high-resolution melting ana...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2007.097121

    authors: Seipp MT,Pattison D,Durtschi JD,Jama M,Voelkerding KV,Wittwer CT

    更新日期:2008-01-01 00:00:00

  • Development of a proton nuclear magnetic resonance spectroscopic method for determining plasma lipoprotein concentrations and subspecies distributions from a single, rapid measurement.

    abstract::We are developing a method for quantifying plasma lipoproteins by proton nuclear magnetic resonance (NMR) spectroscopy that offers advantages over existing clinical methods. We showed that the major lipoproteins have distinct NMR properties sufficient to permit their concentrations to be extracted from a computer line...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Otvos JD,Jeyarajah EJ,Bennett DW,Krauss RM

    更新日期:1992-09-01 00:00:00

  • Data Normalization Strategies for MicroRNA Quantification.

    abstract:BACKGROUND:Different technologies, such as quantitative real-time PCR or microarrays, have been developed to measure microRNA (miRNA) expression levels. Quantification of miRNA transcripts implicates data normalization using endogenous and exogenous reference genes for data correction. However, there is no consensus ab...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,评审

    doi:10.1373/clinchem.2015.239459

    authors: Schwarzenbach H,da Silva AM,Calin G,Pantel K

    更新日期:2015-11-01 00:00:00

  • Delta and conjugated bilirubin as complementary markers of early rejection in liver-transplant recipients.

    abstract::For 51 liver allograft recipients, we evaluated whether serum profiles of delta (Bd) and conjugated bilirubins (Bc) could be used to diagnose rejection during the first 30-50 postoperative days, in comparison with histology as the "gold standard." Daily measurements of aspartate aminotransferase, alkaline phosphatase,...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Wu TW,Levy GA,Yiu S,Au JX,Greig PD,Strasberg SM,Ettles M,Abecassis M,Superina RA,Langer B

    更新日期:1990-01-01 00:00:00

  • Aspartate aminotransferase macroenzyme complex in serum identified and characterized.

    abstract::Macromolecular aspartate aminotransferase was found in the serum of an apparently healthy patient. This complex was composed of aspartate aminotransferase (AST; EC 2.6.1.1) and immunoglobulin. Electrophoresis of the patient's serum showed an abnormal band migrating between mitochondrial (m) and cytosolic (s) AST. The ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Stasia MJ,Surla A,Renversez JC,Pene F,Morel-Femelez A,Morel F

    更新日期:1994-07-01 00:00:00

  • New dual monoclonal ELISA for measuring plasma osteopontin as a biomarker associated with survival in prostate cancer: clinical validation and comparison of multiple ELISAs.

    abstract:BACKGROUND:A previously developed monoclonal/polyclonal ELISA (Mono/Poly) to detect plasma concentrations of osteopontin (OPN) was shown to provide prognostic information in breast, prostate, and other cancers. Here we describe the clinical validation of a new dual monoclonal (Dual Mono) assay. We compared both assays ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2008.117465

    authors: Anborgh PH,Wilson SM,Tuck AB,Winquist E,Schmidt N,Hart R,Kon S,Maeda M,Uede T,Stitt LW,Chambers AF

    更新日期:2009-05-01 00:00:00

  • Systematic Review and Metaanalysis Comparing the Bias and Accuracy of the Modification of Diet in Renal Disease and Chronic Kidney Disease Epidemiology Collaboration Equations in Community-Based Populations.

    abstract:BACKGROUND:The majority of patients with chronic kidney disease are diagnosed and monitored in primary care. Glomerular filtration rate (GFR) is a key marker of renal function, but direct measurement is invasive; in routine practice, equations are used for estimated GFR (eGFR) from serum creatinine. We systematically a...

    journal_title:Clinical chemistry

    pub_type: 杂志文章,meta分析

    doi:10.1373/clinchem.2017.276683

    authors: McFadden EC,Hirst JA,Verbakel JY,McLellan JH,Hobbs FDR,Stevens RJ,O'Callaghan CA,Lasserson DS

    更新日期:2018-03-01 00:00:00

  • Vitamin C and glycohemoglobin.

    abstract::Three groups of 10 age- and sex-matched nondiabetic volunteers took 0, 750, or 1500 mg of vitamin C each day for 12 weeks. Glycohemoglobin (GHb) was measured by HPLC, electrophoresis, affinity chromatography, and immunoassay at baseline (-4 weeks and -1 day), during supplementation (6 weeks and 12 weeks), and after su...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Weykamp CW,Penders TJ,Baadenhuijsen H,Muskiet FA,Martina W,van der Slik W

    更新日期:1995-05-01 00:00:00

  • Microcalorimetric determination of glucose in reference samples of serum.

    abstract::Ireport a detailed series of microcalorimetric measurement of glucose concentrations in five reference samples of serum. The method utilized (a) calibration in the actual medium of analysis and (b) a correction for interferences owing to the nonspecificity of the enzyme hexokinase. The microcalorimetric results are co...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Goldberg RN

    更新日期:1976-10-01 00:00:00

  • Novel, aberrantly truncated isoform of serum CD13 in a family with high serum aminopeptidase N (CD13) activity.

    abstract:BACKGROUND:We previously reported a family in which the propositus and both her father and paternal grandmother had high serum aminopeptidase N (CD13; EC 3.4.11.2) activity (autosomal dominant). The molecular mass of the serum CD13 polypeptide of the propositus was larger than that of normal CD13, suggesting either a m...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Kawai M,Hara Y,Miyazato I,Hosaki S

    更新日期:2001-02-01 00:00:00

  • Accuracy and comparability of long-term measurements of cholesterol.

    abstract::Laboratories of the Lipid Research Clinics Program (LRC) maintained the accuracy of their measurements of total cholesterol by using seven pooled serum calibrators supplied by the Centers for Disease Control (CDC). Over the 11-year life of the LRC, each calibrator was prepared in succession and a target value was assi...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Hainline A Jr,Karon JM,Winn CL,Gill JB

    更新日期:1986-04-01 00:00:00

  • Anaphylaxis in the mouse--a model for using two-dimensional electroimmunodiffusion to study pathological changes in multiple serum proteins simultaneously.

    abstract::Two-dimensional electroimmunodiffusion is rarely used in clinical chemistry, because its potentialities are not yet widely appreciated. Studying mouse anaphylaxis, we observed with this technique certain striking short- and long-term pathologic changes in several important serum antigens, which aptly demonstrate its u...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Quintero S,Crowle AJ

    更新日期:1979-05-01 00:00:00

  • Analysis for indole compounds in urine by high-performance liquid chromatography with fluorometric detection.

    abstract::We describe a chromatographic system involving a high-performance chemically-bonded reverse-phase column and fluorescence detection for measurement of indoles in urine. We controlled retention and selectivity by optimizing the methanol content and pH of the mobile phase. Six reference indoles were separated in less th...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Graffeo AP,Karger BL

    更新日期:1976-02-01 00:00:00

  • Falsely high high-density lipoprotein triglyceride values by the heparin-manganese precipitation method.

    abstract::Recent evidence indicates that high-density lipoprotein triglyceride (HDL-Tg) may be a predictor of coronary artery disease. We examined three methods for HDL-Tg measurement, comparing results obtained by measurement of Tg in the supernate after heparin-manganese chloride (heparin-Mn) precipitation of EDTA-treated pla...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Simo IE,Kiss Z,Ooi TC

    更新日期:1988-10-01 00:00:00

  • Serum concentrations of cross-linked N-telopeptides of type I collagen: new marker for bone resorption in hemodialysis patients.

    abstract:BACKGROUND:Urinary cross-linked N-telopeptide of type I collagen (NTX) is a reliable bone resorption marker in patients with metabolic bone disease. We assessed a clinically available serum NTX assay suitable for anuric patients on hemodialysis (HD). METHODS:Serum concentrations of NTX, C-terminal telopeptide of type ...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:10.1373/clinchem.2005.051524

    authors: Maeno Y,Inaba M,Okuno S,Yamakawa T,Ishimura E,Nishizawa Y

    更新日期:2005-12-01 00:00:00

  • Potentiometry of Na+ in undiluted serum and urine with use of an improved neutral carrier-based solvent polymeric membrane electrode.

    abstract::We present an improved Na+-selective liquid membrane electrode for measurement of Na+ concentrations in both undiluted serum and urine. The values for urinary Na+ obtained with the ion-selective electrode agree well with those obtained with the flame photometer. The correlation gives a standard residual deviation of +...

    journal_title:Clinical chemistry

    pub_type: 杂志文章

    doi:

    authors: Anker P,Jenny HB,Wuthier U,Asper R,Ammann D,Simon W

    更新日期:1983-08-01 00:00:00