Abstract:
:We have attempted to list all the clinical applications of capnography described to date and classify them into categories. From an extensive Pubmed search 46 clinical applications of capnography were listed. To classify these we used six categories- Airway, Breathing, Circulation, Anesthetic Delivery Apparatus, Homeostasis and Non-perioperative. This list collates the described uses of capnography and this system of classification provides an aide-de-memoir in anesthesia education and simulation.
journal_name
J Clin Monit Computjournal_title
Journal of clinical monitoring and computingauthors
Eipe N,Tarshis Jdoi
10.1007/s10877-007-9094-8subject
Has Abstractpub_date
2007-12-01 00:00:00pages
341-4issue
6eissn
1387-1307issn
1573-2614journal_volume
21pub_type
杂志文章abstract::The test of the inner tube integrity is an important checklist prior to the safe use of Bain's breathing system. This is because the major concern with the use of Bain's circuit is the potential malfunctioning of the circuit due to avulsion of the inner fresh gas delivery tube at the machine end which will turn the ou...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9212-x
更新日期:2010-02-01 00:00:00
abstract::Mathematical models can be deployed to simulate physiological processes of the human organism. Exploiting these simulations, reactions of a patient to changes in the therapy regime can be predicted. Based on these predictions, medical decision support systems (MDSS) can help in optimizing medical therapy. An MDSS desi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9502-1
更新日期:2014-12-01 00:00:00
abstract::The purpose of this concept study was to investigate the possibility of automatic mean arterial pressure (MAP) regulation in a porcine heart-beating brain death (BD) model. Hemodynamic stability of BD donors is necessary for maintaining acceptable quality of donated organs for transplantation. Manual stabilization is ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-017-0033-z
更新日期:2018-06-01 00:00:00
abstract::To evaluate a compact and easily interpretable 4-parameter model describing the shape of the volumetric capnogram, and the resulting estimates of anatomical dead space (VDAW) and Phase III (alveolar plateau) slope (SIII). Data from of 8 mildly-endotoxemic pre-acute respiratory distress syndrome sheep were fitted to th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00451-4
更新日期:2020-12-01 00:00:00
abstract::Auditory steady state responses (ASSR) may offer an alternative to brainstem auditory evoked potentials for monitoring of the auditory nerve during surgical procedures. In the current study, we evaluated the influence of noise on ASSR characteristics in total intravenous anesthesia (TIVA). Simulated ASSR in real noise...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9837-5
更新日期:2017-02-01 00:00:00
abstract::We know that a 10 cm departure from the reference level of pressure transducer position is equal to a 7.5 mmHg change of invasive hemodynamic pressure monitoring in a fluid-filled system. However, the relationship between the site level of a variable arterial pressure transducer and the pulse contour-derived parameter...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9756-x
更新日期:2016-10-01 00:00:00
abstract::Hypotension subsequent to spinal anesthesia occurs in a significant number of parturients undergoing lower segment caesarian section. Currently available methods to predict the incidence of hypotension, its severity and the outcome are sub-optimal. Many workers have used basal heart rate as one of the predictors. But ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-016-9906-9
更新日期:2017-08-01 00:00:00
abstract::One of the main goals of hemodynamic support is to preserve tissue perfusion. However issue perfusion is related more to microvascular perfusion than aortic blood flow. Monitoring the microcirculation has long been difficult. Recent technologic advances have made feasible monitoring of the microcirculation at bedside ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-012-9383-8
更新日期:2012-10-01 00:00:00
abstract::Audible pulse tones, based on a variable-pitch frequency scale, allow the anesthesiologist to determine the patient's oxygen saturation without constant visual examination of the monitor display. The ability to reliably detect oxygen saturation levels based on audible pulse tones may be compromised when multiple pulse...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1023/b:jocm.0000032698.47717.06
更新日期:2004-04-01 00:00:00
abstract::Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO2) based on the absorption spectra of oxygenated and deoxygenated hemoglobin, and the translucency of biological tissue, in the near-infrared band. There is increasing evidence that optimising cerebral oxygenation, guided by ScO2, is associated wi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-014-9642-y
更新日期:2015-10-01 00:00:00
abstract::The utility of capnography to detect early respiratory compromise in surgical patients after anesthesia is unclear due to limited prospective data. The purpose of this trial was to determine the frequency and duration of capnography-detected respiratory adverse events in the post-anesthesia care unit (PACU). In this p...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00333-9
更新日期:2020-06-01 00:00:00
abstract::In mechanical ventilation, a careful setting of the ventilation parameters in accordance with the current individual state of the lung is crucial to minimize ventilator induced lung injury. Positive end-expiratory pressure (PEEP) has to be set to prevent collapse of the alveoli, however at the same time overdistension...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,多中心研究
doi:10.1007/s10877-014-9562-x
更新日期:2014-12-01 00:00:00
abstract::Recently a novel pain recognition indicator derived from electroencephalogram(EEG) signals, pain threshold index(PTI) has been developed. The aim of this study was to determine whether PTI can be used for prediction of postoperative acute pain while surgical pleth index(SPI) applied as control. Eighty patients undergo...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00604-w
更新日期:2020-10-12 00:00:00
abstract::To assess the feasibility, stability and predictability of pCO2 measurement (PETCO2) using a main stream capnograph in a high frequency oscillatory ventilation circuit. A commercially available capnograph was mounted into a high frequency oscillatory ventilator patient circuit, adjustable CO2 flow was introduced into ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9495-9
更新日期:2014-02-01 00:00:00
abstract::To develop and validate a mathematical model for predicting intracranial pressure (ICP) noninvasively using phase-contrast cine MRI (PC-MRI). We performed a retrospective analysis of PC-MRI from patients with communicating hydrocephalus (n = 138). The patients were recruited from Shenzhen Second People's Hospital betw...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00598-5
更新日期:2020-10-01 00:00:00
abstract::Studies reveal that the false alarm rate (FAR) demonstrated by intensive care unit (ICU) vital signs monitors ranges from 0.72 to 0.99. We applied machine learning (ML) to ICU multi-sensor information to imitate a medical specialist in diagnosing patient condition. We hypothesized that applying this data-driven approa...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00307-x
更新日期:2020-04-01 00:00:00
abstract:OBJECTIVE:To demonstrate the usefulness of rectus femoris muscle MEPs monitoring in a paraparetic neuromuscular scoliosis case. METHODS:Multiple monitoring modalities including SEPs, MEPs and EMG were performed for an anterior and posterior correction surgery for a neuromuscular scoliosis patient with no motor and sen...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-011-9325-x
更新日期:2012-02-01 00:00:00
abstract::Continual vital sign assessment on the general care, medical-surgical floor is expected to provide early indication of patient deterioration and increase the effectiveness of rapid response teams. However, there is concern that continual, multi-parameter vital sign monitoring will produce alarm fatigue. The objective ...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9790-8
更新日期:2016-12-01 00:00:00
abstract::FloTrac/Vigileo™ system is based on arterial pressure waveform analysis arterial pressure-based CO (APCO). Therefore, systemic vascular resistance (SVR) can influence the accuracy of APCO. The purpose of this study is to evaluate the relationship between SVR and the accuracy of APCO. We managed 50 consecutive patients...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-013-9481-2
更新日期:2013-12-01 00:00:00
abstract::The use of processed electroencephalography (EEG) using a simple frontal lead system has been made available for assessing the impact of anesthetic medications during surgery. This review discusses the basic principles behind these devices. The foundations of anesthesia monitoring rest on the observations of Guedel wi...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,评审
doi:10.1007/s10877-006-9044-x
更新日期:2006-12-01 00:00:00
abstract::Electrical impedance tomography (EIT) is used in lung physiology monitoring. There is evidence that EIT is linearly associated with global tidal volume (VT) in clinically healthy patients where no positive end-expiratory pressure (PEEP) is applied. This linearity has not been challenged by altering lung conditions. Th...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-021-00651-x
更新日期:2021-01-25 00:00:00
abstract::The goal of the study was to evaluate the effectiveness of analgesia nociception index (ANI) monitoring during intraoperative period for patients with thoracic paravertebral block (TPVB) undergoing breast surgery under general anesthesia. This prospective randomized trial was performed after receiving ethics committee...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章,随机对照试验
doi:10.1007/s10877-017-0036-9
更新日期:2018-06-01 00:00:00
abstract::Recent progress in genomics and experimental biology has brought exponential growth of the biological information available for computational analysis in public genomics databases. However, applying the potentially enormous scientific value of this information to the understanding of biological systems requires comput...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-3463-y
更新日期:2005-10-01 00:00:00
abstract:OBJECTIVE:Serious accidents during hemodialysis such as a large amount of blood loss are often caused by venous needle dislodgement. To develop a bleeding sensor based on a photo sensor for monitoring the needle sites, we studied effects of liquids and porcine blood on light transmission through a thin gauze pad with a...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-009-9206-8
更新日期:2010-02-01 00:00:00
abstract::Cerebrovascular autoregulation (CA) is often impaired following traumatic brain injury. Established technologies and metrics used to assess CA are invasive and conducive for measurement, but not for continuous monitoring. We developed a trans-ocular brain impedance (TOBI) method that may provide non-invasive and conti...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-020-00556-1
更新日期:2020-07-14 00:00:00
abstract::Loss of endotracheal cuff pressure can lead to airway compromise and loss of volume delivery in mechanical ventilation requiring immediate intervention. A 40 years old male posted for bilateral interpositional arthroplasty was intubated nasally with 7.5 mm flexometallic endotracheal tube. In the intraoperative period ...
journal_title:Journal of clinical monitoring and computing
pub_type: 信件
doi:10.1007/s10877-020-00607-7
更新日期:2020-10-23 00:00:00
abstract::Incident dark field imaging (IDF) is a new generation handheld microscope for bedside visualization and quantification of microcirculatory alterations. IDF is the technical successor of sidestream dark field imaging (SDF), currently the most used device for microcirculatory measurements. In (pre)term neonates the redu...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-015-9708-5
更新日期:2015-10-01 00:00:00
abstract::Real time information of Hb concentration can guide a tailored patient blood management. The study investigates the accuracy, precision and trending ability of the Pulse CO-Oximeter (SpHb) and blood gas analyzer in measuring the Hb concentration, compared to hematological analysis, in surgery at high risk of hemorrhag...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-019-00337-5
更新日期:2020-06-01 00:00:00
abstract:OBJECTIVES:To determine if wavelet analysis techniques can be used to reliably identify individual breaths from the photoplethysmogram (PPG). METHODS:Photoplethysmograms were obtained from 22 healthy adult volunteers timing their respiration rate in synchronisation with a metronome. A secondary timing signal was obtai...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-2697-z
更新日期:2004-12-01 00:00:00
abstract::Changes in expired nitric oxide (NO) occur in airway inflammation and have proved to be important in the monitoring of inflammatory disease processes such as asthma. We set out to develop a novel hand-held NO-analyzer with a performance comparable to the present more costly and complex chemiluminescence instruments. T...
journal_title:Journal of clinical monitoring and computing
pub_type: 杂志文章
doi:10.1007/s10877-005-1158-z
更新日期:2004-12-01 00:00:00