Successful coronary stent retrieval from a pedal artery.

Abstract:

:The purpose of this article is to report complications from a coronary drug-eluting stent lost in the peripheral circulation. We report the case of successful retrieval of a sirolimus coronary stent from a pedal artery in a young patient who underwent coronary angiography for previous anterior myocardial infarction. Recognition of stent embolization requires adequate removal of the device to avoid unwelcome clinical sequelae.

authors

Mariano E,Versaci F,Gandini R,Simonetti G,Di Vito L,Romeo F

doi

10.1007/s00270-007-9151-1

subject

Has Abstract

pub_date

2008-05-01 00:00:00

pages

655-8

issue

3

eissn

0174-1551

issn

1432-086X

journal_volume

31

pub_type

杂志文章
  • Catheter-malposition-induced cardiac tamponade via contrast media leakage during computed tomography study.

    abstract::We present a rare case of a central venous catheter-malposition-induced life-threatening cardiac tamponade as a result of computed tomography (CT) with contrast enhancement in an infant with a ventricular septal defect and pulmonary atresia after a modified Blalock-Taussig shunt. The diagnosis was confirmed by chest r...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0340-x

    authors: Liang CD,Ko SF,Huang CF,Chien SJ,Tiao MM

    更新日期:2005-11-01 00:00:00

  • Fatal intraventricular hemorrhage after the extracranial carotid artery angioplasty and stent placement.

    abstract::We report on a 72-year-old female with an unusual intracranial bleeding complication after an extracranial carotid artery stenting procedure performed for a tight left ICA stenosis associated with contralateral carotid occlusion. Two hours after the procedure, the initial signs of intracranial bleeding appeared that l...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0155-9

    authors: Krajickova D,Krajina A,Nova M,Raupach J

    更新日期:2005-07-01 00:00:00

  • Wireless blood pressure monitoring with a novel implantable device: long-term in vivo results.

    abstract:PURPOSE:Devices constantly tracking the blood pressure (BP) of hypertensive patients are highly desired to facilitate effective patient management and to reduce hospitalization. We report on experiences gathered in a pilot study that was designed to evaluate the prototype of a newly developed, minimally invasive implan...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0842-0

    authors: Cleven NJ,Isfort P,Penzkofer T,Woitok A,Hermanns-Sachweh B,Steinseifer U,Schmitz-Rode T

    更新日期:2014-12-01 00:00:00

  • Percutaneous minimally invasive treatment of malignant biliary strictures: current status.

    abstract::The concept of percutaneous management of malignant biliary obstruction has not significantly changed in the last two decades and is based on the successful drainage of bile toward the duodenum, which normalizes liver function and prevents the development of cholangitis and sepsis. However, patient survival has change...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-013-0693-0

    authors: Krokidis M,Hatzidakis A

    更新日期:2014-04-01 00:00:00

  • Congenital intrahepatic portosystemic shunt.

    abstract::The authors report a congenital intrahepatic portosystemic shunt detected by angiography in a young patient with acute onset of hyperammoniemia and hepatic encephalopathy. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 评论,杂志文章,评审

    doi:10.1007/s002709900291

    authors: Florio F,Nardella M,Balzano S,Giacobbe A,Perri F

    更新日期:1998-09-01 00:00:00

  • Vascular Closure Devices in Interventional Radiology Practice.

    abstract::Manual compression (MC) is a well-established technique for haemostasis following percutaneous arterial intervention. However, MC is labour and time intensive with potential limitations, particularly for patients who are coagulopathic, unable to comply with bed rest or obese and when large sheaths or anti-coagulants a...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,评审

    doi:10.1007/s00270-015-1116-1

    authors: Patel R,Muller-Hulsbeck S,Morgan R,Uberoi R

    更新日期:2015-08-01 00:00:00

  • Diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy of solitary pulmonary nodules.

    abstract:OBJECTIVE:The purpose of our study was to evaluate the diagnostic accuracy of MRI-guided percutaneous transthoracic needle biopsy (PTNB) of solitary pulmonary nodules (SPNs). METHODS:Retrospective review of 69 patients who underwent MR-guided PTNB of SPNs was performed. Each case was reviewed for complications. The fi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-014-0915-0

    authors: Liu S,Li C,Yu X,Liu M,Fan T,Chen D,Zhang P,Ren R

    更新日期:2015-04-01 00:00:00

  • Complication rates and patency of radiologically guided mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy: a review of 250 procedures.

    abstract:PURPOSE:To compare complication rates and tube performance of percutaneous mushroom gastrostomy, balloon gastrostomy, and gastrojejunostomy. METHODS:Between September 9, 1999 and April 23, 2001, 203 patients underwent 250 radiologically guided percutaneous gastrostomy and gastrojejunostomy procedures. Follow-up was co...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-003-0108-8

    authors: Yip D,Vanasco M,Funaki B

    更新日期:2004-01-01 00:00:00

  • Diameters of pulmonary veins in normal children--an angiocardiographic study.

    abstract::The diameters of the pulmonary veins at their atrial junction were measured from cineangiocardiographic films in 27 children (mean height 128.5 cm) without heart disease. Right upper pulmonary veins and right lower pulmonary veins were measured in all 27 films. The left upper pulmonary veins could be measured in 23 ch...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575426

    authors: Robida A

    更新日期:1989-11-01 00:00:00

  • Percutaneous cryotherapy of vascular malformation: initial experience.

    abstract::The present report describes a case of percutaneous cryotherapy in a 36-year-old woman with a large and painful pectoral venous malformation. Cryoablation was performed in a single session for this 9-cm mass with 24 h hospitalisation. At 2- and 6-month follow-up, the pain had completely disappeared, and magnetic reson...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0434-9

    authors: Cornelis F,Neuville A,Labrèze C,Kind M,Bui B,Midy D,Palussière J,Grenier N

    更新日期:2013-06-01 00:00:00

  • Comparison of digital with conventional ventriculography for quantitative right ventricular studies.

    abstract::To assess the feasibility of quantitative central venous digital angiocardiography, right ventricular spatial orientation, size, and shape were compared with measurements based on conventional angiocardiography, both obtained during routine cardiac catheterization in 21 children with various congenital heart defects. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577015

    authors: Lange PE,Radtke W,Fellows KE,Onnasch DG,Heintzen PH

    更新日期:1988-01-01 00:00:00

  • Adjunctive inferior vena cava filter placement for acute pulmonary embolism.

    abstract::Inferior vena cava (IVC) filters are sometimes placed as an adjunct to full anticoagulation in patients with significant pulmonary embolism (PE). We aimed to determine the prevalence of adjunctive IVC filter placement in individuals diagnosed with PE, as well as the effect of adjunctive filter placement on mortality i...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-010-9905-z

    authors: Jha VM,Lee-Llacer J,Williams J,Ubaissi H,Gutierrez G

    更新日期:2010-08-01 00:00:00

  • Lifesaving embolization of coronary artery perforation.

    abstract::Coronary artery perforation remains one of the most fearsome complications during cardiac catheterization procedures. Although emergent bypass surgery is the preferred treatment for cases with uncontrollable perforation, endovascular vessel sealing and arrest of bleeding with a combination of balloons, covered stents,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9657-9

    authors: Katsanos K,Patel S,Dourado R,Sabharwal T

    更新日期:2009-09-01 00:00:00

  • Retinal embolization during carotid angioplasty and stenting: periprocedural data and follow-up.

    abstract::The purpose of this study was to prospectively evaluate the incidence of retinal emboli during carotid angioplasty and stenting (CAS) and to correlate emboli with clinical findings and transcranial Doppler (TCD)-detected cerebral embolic load. Between 2001 and 2005, 33 CAS procedures in 32 patients (23 [72%] male, 19 ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9775-4

    authors: Vos JA,van Werkum MH,Bistervels JH,Ackerstaff RG,Tromp SC,van den Berg JC

    更新日期:2010-08-01 00:00:00

  • Applicability of liquid radiopaque polyurethane for transcatheter embolization.

    abstract::Polyurethane Bayer was tested as an occlusive agent for experimental embolization in postmortem and postnephrectomy kidneys which served as a tumor model. Coaxial and balloon catheters were used for the embolization. To make polyurethane radiopaque, the material was labeled with different water-soluble, oily and solid...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02552764

    authors: Novak D,Wieners H,Rueckner R

    更新日期:1983-01-01 00:00:00

  • Stenting of the superior mesenteric artery as a preoperative treatment for total pancreatectomy.

    abstract::The patient was 58-year-old male with mucinous cyst adenocarcinoma of the pancreas. Prior to total pancreatectomy, preoperative CT and angiography showed a high-grade arteriosclerotic stenosis of about 1.0 cm in length in the ostium of the superior mesenteric artery (SMA), as well as the development of collateral vess...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-004-0036-2

    authors: Tanigawa N,Kariya S,Komemushi A,Satoi S,Kamiyama Y,Sawada S,Kojima H,Sougawa M,Takai Y

    更新日期:2004-09-01 00:00:00

  • Development of a new hanging-type esophageal stent for preventing migration: a preliminary study in an animal model of esophagotracheal fistula.

    abstract:PURPOSE:Covered, self-expandable metallic stents (SEMS) have been enthusiastically adopted for the treatment of esophagotracheal fistula, but problems with stent migration have yet to be resolved. To overcome this problem, we have developed a new hanging-type esophageal stent designed to prevent migration, and we condu...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-011-0240-9

    authors: Endo M,Kaminou T,Ohuchi Y,Sugiura K,Yata S,Adachi A,Kawai T,Takasugi S,Yamamoto S,Matsumoto K,Hashimoto M,Ihaya T,Ogawa T

    更新日期:2012-10-01 00:00:00

  • Radiation Dose and Risk Estimates of CT-Guided Percutaneous Liver Ablations and Factors Associated with Dose Reduction.

    abstract:PURPOSE:To determine the radiation dose associated with CT-guided percutaneous liver ablations and identify potential risk factors that result in higher radiation doses. MATERIALS AND METHODS:Between June 2011 and June 2015, 245 consecutive patients underwent 304 CT-guided liver ablation treatments. Patient demographi...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-018-2066-1

    authors: McCarthy CJ,Kilcoyne A,Li X,Cahalane AM,Liu B,Arellano RS,Uppot RN,Gee MS

    更新日期:2018-12-01 00:00:00

  • Freehand two-step CT-guided brain tumor biopsy: a fast and effective interventional procedure in selected patients.

    abstract:PURPOSE:To evaluate the efficacy and safety of CT-guided needle biopsy of brain lesions without a stereotactic device, and to determine the best possible indications for this technique. METHODS:From February 2001 to February 2004, 20 patients (12 men, 8 women; age 61-82 years) underwent CT-guided brain lesion biopsy. ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-005-0015-2

    authors: Thanos L,Mylona S,Galani P,Kalioras V,Pomoni M,Batakis N

    更新日期:2006-03-01 00:00:00

  • Curved Needles in CT-Guided Fine Needle Biopsies of Abdominal and Retroperitoneal Small Lesions.

    abstract:PURPOSE:To demonstrate the advantages of using curved needles in fine needle aspiration (FNA) with CT-guided, for analyzing abdominal and/or retroperitoneal small lesions which are impossible to reach with conventional non-surgical biopsy techniques, particularly in cases in which the cytology sample was not possible t...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-015-1107-2

    authors: De Filippo M,Saba L,Rossi E,Nizzoli R,Tiseo M,Pedrazzi G,Brunese L,Rotondo A,Rossi C

    更新日期:2015-12-01 00:00:00

  • Transhepatic approach for percutaneous computed-tomography-guided radiofrequency ablation of renal cell carcinoma.

    abstract::We performed percutaneously radiofrequency (RF) ablation of 5 renal cell carcinomas (mean diameter 26 +/- 15 mm) with computed-tomography (CT) fluoroscopic guidance using the transhepatic route. The RF electrode was successfully advanced into all tumors. RF ablation caused one minor complication (small asymptomatic pe...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-007-9037-2

    authors: Iguchi T,Hiraki T,Gobara H,Mukai T,Hase S,Fujiwara H,Tajiri N,Sakurai J,Mimura H,Saika T,Kumon H,Kanazawa S

    更新日期:2007-07-01 00:00:00

  • Broken esophageal stent successfully treated by interventional radiology technique.

    abstract::Esophageal stent fractures occur quite rarely. A 61-year-old male patient was previously treated for rupture of benign stenosis, occurring after dilatation, by implanting an esophageal stent. However, a year after implantation, the patient suffered from dysphagia caused by the broken esophageal stent. He was treated w...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9648-x

    authors: Zelenák K,Mistuna D,Lúcan J,Polácek H

    更新日期:2010-06-01 00:00:00

  • Günter tulip filter retrieval experience: predictors of successful retrieval.

    abstract::We report our experience with Günter Tulip filter placement indications, retrievals, and procedural problems, with emphasis on alternative retrieval techniques. We have identified 92 consecutive patients in whom a Günter Tulip filter was placed and filter removal attempted. We recorded patient demographic information,...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-009-9684-6

    authors: Turba UC,Arslan B,Meuse M,Sabri S,Macik BG,Hagspiel KD,Matsumoto AH,Angle JF

    更新日期:2010-08-01 00:00:00

  • Use of digital video coronary arteriography in the performance of percutaneous transluminal coronary angioplasty.

    abstract::Digital video coronary arteriography (DVCA) was used in 59 cases of percutaneous transluminal coronary angioplasty (PTCA) and found to be useful for display of imagery to facilitate choice of approach to a stenotic lesion; providing a "road map," simplifying guide wire manipulation and selective catheterization of ves...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02577966

    authors: Boxt LM,Meyerovitz MF,Taus RH,Harrington DP,Ganz P,Friedman PL,Levin DC

    更新日期:1987-01-01 00:00:00

  • Stent-induced esophageal perforation: treatment by means of placing a second stent after removal of the original stent.

    abstract::A case of esophageal perforation caused by a retrievable covered stent is presented. The distal end of the stent was protruding into the mediastinum, which made it impossible to negotiate a guidewire through the stent into the distal esophagus. The stent was successfully removed with use of a stent retrieval set, and ...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-008-9303-y

    authors: Jung GS,Park SD,Cho YD

    更新日期:2008-05-01 00:00:00

  • Triple catheter aortoiliac angioplasty in a patient with a horseshoe kidney: technical note.

    abstract::A method is described for protecting a nonstenotic anomalous artery to the left-lower pole of a horseshoe kidney that originated from a stenotic left common iliac artery. Using a triple catheter technique, injury to this anomalous renal artery was prevented while using "kissing balloons" to dilate bilateral proximal c...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/BF02575433

    authors: Matsumoto AH,Baum PA,Barth KH,Teitelbaum GP

    更新日期:1989-11-01 00:00:00

  • Percutaneous Vertebroplasty is no Risk Factor for New Vertebral Fractures and Protects Against Further Height Loss (VERTOS IV).

    abstract:BACKGROUND:Percutaneous vertebroplasty (PV) is an alternative option to treat pain after an osteoporotic vertebral compression fracture (OVCF). Controversy exists as to whether PV increases the risk of new OVCFs or prevents further vertebral height loss in treated levels. We assessed both during 1-year follow-up in pat...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章,多中心研究,随机对照试验

    doi:10.1007/s00270-019-02205-w

    authors: Firanescu CE,de Vries J,Lodder P,Schoemaker MC,Smeets AJ,Donga E,Juttmann JR,Klazen CAH,Elgersma OEH,Jansen FH,van der Horst I,Blonk M,Venmans A,Lohle PNM

    更新日期:2019-07-01 00:00:00

  • Relief of mesenteric ischemia by Z-stent placement into the superior mesenteric artery compressed by the false lumen of an aortic dissection.

    abstract::In a 58-year-old man acute aortic dissection compromised the origin of the superior mesenteric artery (SMA), resulting in mesenteric ischemia. After failed balloon angioplasty a Gianturco Z-stent was placed. The stenosis improved immediately, followed by resolution of the clinical signs of mesenteric ischemia. SMA flo...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s002709900214

    authors: Yamakado K,Takeda K,Nomura Y,Kato N,Hirano T,Matsumura K,Nakagawa T,Yuasa H,Yada I

    更新日期:1998-01-01 00:00:00

  • The optimal dose of nicardipine for enhancement of indirect portography.

    abstract:PURPOSE:To determine the optimal dose of nicardipine (NCR) for enhancement of indirect portography. METHODS:Forty-eight patients underwent conventional film indirect portography via the superior mesenteric artery (SMA) first without and then with preinjection of 1/64-2 mg of NCR into the SMA. RESULTS:NCR (1/8-2 mg) s...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1007/s002709900204

    authors: Inoue Y,Nakamura H,Akaji H

    更新日期:1998-01-01 00:00:00

  • Short-term effects of Ankaferd hemostat for renal artery embolization: an experimental study.

    abstract:PURPOSE:Renal artery embolization (RAE) is a minimally invasive therapeutic technique that is utilized in a number of disorders. Ankaferd is a novel hemostatic agent with a new mechanism of action independent of clotting factors. We used Ankaferd for RAE in a sheep model. METHODS:Seven adult female sheep were included...

    journal_title:Cardiovascular and interventional radiology

    pub_type: 杂志文章

    doi:10.1007/s00270-012-0419-8

    authors: Ozbek O,Acar K,Koc O,Saritas K,Toy H,Solak Y,Ozbek S,Kucukapan A,Guler I,Gaipov A,Turk S,Haznedaroglu IC

    更新日期:2013-04-01 00:00:00