Bone level changes at axial- and non-axial-positioned implants supporting fixed partial dentures. A 5-year retrospective longitudinal study.

Abstract:

AIM:The aim of this study was to retrospectively analyze the potential influence of implant inclination on marginal bone loss at freestanding, implant-supported, fixed partial dentures (FPDs) over a 5-year period of functional loading. MATERIAL AND METHODS:The material comprised 38 periodontally treated, partially dentate patients with a total of 42 free-standing FPDs supported by implants of the Astra Tech System. Mesio-distal inclination of the implants in relation to a vertical axis perpendicular to the occlusal plane was measured with a protractor on standardized photographs of the master cast. The two tail quartiles of the distribution of the implants with regard to the implant inclination were defined as axial-positioned (mean 2.4 degrees; range 0-4 degrees) and non-axial-positioned implants (mean 17.1 degrees; range 11-30 degrees), respectively. For FPDs supported by two implants, both the mesial-distal and buccal-lingual inter-implant inclination was measured. The primary outcome variable was change in peri-implant bone level from the time of FPD placement to the 5-year follow-up examination. Comparison between axial- and non-axial-positioned implants was performed by the use of a Mann-Whitney U-test. Spearman's correlation analysis was used to analyze relationships between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change on the FPD level. RESULTS:The 5-year mean bone level change amounted to 0.4 mm (SD 0.97) for the axial and 0.5 mm (0.95) for non-axial-positioned implants (P>0.05). For the FPDs supported by two implants, the mean inter-implant inclination was 9.2 degrees (1-36 degrees) in the mesial-distal direction and 6.7 degrees (0-24 degrees) in the buccal-lingual direction. Correlation analysis revealed lack of statistically significant correlation between inter-implant inclination (mesial-distal and buccal-lingual) and 5-year bone level change (r=-0.19 and r=-0.32, respectively). CONCLUSION:The study failed to support the hypothesis that implant inclination has an effect on peri-implant bone loss.

journal_name

Clin Oral Implants Res

authors

Koutouzis T,Wennström JL

doi

10.1111/j.1600-0501.2007.01386.x

subject

Has Abstract

pub_date

2007-10-01 00:00:00

pages

585-90

issue

5

eissn

0905-7161

issn

1600-0501

pii

CLR1386

journal_volume

18

pub_type

杂志文章
  • Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis.

    abstract::Bone anchored implants are now being used in dentistry for supporting intraoral and craniofacial prostheses. Although high success rates have been reported, a small number of implants may fail during the early healing phase or lateral in function. Currently available clinical methods to determine implant stability and...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1996.070308.x

    authors: Meredith N,Alleyne D,Cawley P

    更新日期:1996-09-01 00:00:00

  • Blood responses to titanium surface with TiO2 nano-mesh structure.

    abstract:OBJECTIVES:The goal of this study was to enhance the blood responses to titanium (Ti) surfaces used for dental implant application through the formation of a TiO2 nano-mesh surface layer produced by a fast electrochemical anodization treatment. MATERIAL AND METHODS:Electrochemical anodization treatments with different...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2010.02152.x

    authors: Huang HH,Chen JY,Lin MC,Wang YT,Lee TL,Chen LK

    更新日期:2012-03-01 00:00:00

  • The influence of stiffness of implant-abutment connection on load-deflection ratios of a screw-retained stiff cantilever beam. 3-D measurements in vitro.

    abstract:AIM:The purpose of this in vitro study was to investigate the influence of degree of stiffness of implant-abutment connection of a Brånemark implant system on load- deflection ratios in three dimensions of the beam-end of a screw-retained stiff cantilever beam when subjected to vertically directed loads. MATERIAL AND ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2012.02563.x

    authors: Cassel B,Lundgren D,Karlsson D

    更新日期:2013-11-01 00:00:00

  • A histomorphometric evaluation of screw-shaped implants each prepared with two surface roughnesses.

    abstract::Four different surface modifications were designed. Forty screw-shaped implants were divided into 4 groups, 10 screws in each. Every screw was prepared with 2 different surface topographies. The surface topography was measured with a confocal laser scanning profilometer and the surface roughness was characterized usin...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1998.090102.x

    authors: Wennerberg A,Hallgren C,Johansson C,Danelli S

    更新日期:1998-02-01 00:00:00

  • Spectrophotometric and visual evaluation of peri-implant soft tissue color.

    abstract:AIM:To spectrophotometrically and visually test whether the peri-implant mucosal color differs from the color of the natural gingiva. MATERIAL AND METHODS:Forty single implants in the incisor and premolar region of 40 patients were assessed 3-7 years after implant placement. The differences of the color components lig...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12781

    authors: Benic GI,Scherrer D,Sancho-Puchades M,Thoma DS,Hämmerle CH

    更新日期:2017-02-01 00:00:00

  • Immediate single implant restorations in mandibular molar extraction sockets: a controlled clinical trial.

    abstract:BACKGROUND:In the replacement of missing teeth, a paradigm shift is currently observed with immediate implant placement and/or restoration, particularly in the aesthetic zone. In molar sites, however, anatomical, occlusal and biomechanical considerations remain deterrent factors influencing the outcome of this treatmen...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2011.02415.x

    authors: Atieh MA,Alsabeeha NH,Duncan WJ,de Silva RK,Cullinan MP,Schwass D,Payne AG

    更新日期:2013-05-01 00:00:00

  • Remodelling of sinus bone grafts according to the distance from the native bone: A histomorphometric analysis.

    abstract:OBJECTIVES:To evaluate graft remodelling according to the distance from the native bone in maxillary sinuses grafted with anorganic bovine bone (ABB). MATERIAL AND METHODS:Bilateral sinus grafting was performed in twenty patients with residual bone height <5 mm before implant placement. After 8 months, biopsy samples ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13639

    authors: Pignaton TB,Spin-Neto R,Ferreira CEA,Martinelli CB,de Oliveira GJPL,Marcantonio E Jr

    更新日期:2020-10-01 00:00:00

  • Oblique lateral cephalometric radiographs of the mandible in implantology: usefulness and reproducibility of the technique in quantitative densitometric measurements of the mandible in vivo.

    abstract::In the literature intraoral periapical radiographs are commonly used for densitometric measurements of the mandible with implants. These films give detailed information of the implant and the surrounding bone. However, in extreme mandibular atrophy it can be difficult to obtain intraoral radiographs of adequate diagno...

    journal_title:Clinical oral implants research

    pub_type: 临床试验,杂志文章

    doi:10.1034/j.1600-0501.2000.011005476.x

    authors: Verhoeven JW,Ruijter J,Cune MS,Terlou M

    更新日期:2000-10-01 00:00:00

  • Early loading of sandblasted and acid-etched (SLA) implants: a prospective split-mouth comparative study.

    abstract::Sandblasted and acid-etched (SLA) implants were recently introduced to reduce the healing period between surgery and prosthesis. In this split-mouth study, SLA implants were compared to titanium plasma-sprayed (TPS) implants under loaded conditions one year after placement in 32 healthy patients, with comparable bilat...

    journal_title:Clinical oral implants research

    pub_type: 临床试验,杂志文章,随机对照试验

    doi:10.1034/j.1600-0501.2001.120604.x

    authors: Roccuzzo M,Bunino M,Prioglio F,Bianchi SD

    更新日期:2001-12-01 00:00:00

  • Sinus augmentation via transcrestal approach: a comparison between the balloon and osteotome technique in a cadaver study.

    abstract:BACKGROUND:The transcrestal approach with osteotomes is a commonly applied and predictable technique for maxillary sinus floor elevation. However, Schneiderian membrane perforation is a common and often inevitable intraoperative complication. Recently, the use of balloons has been proposed to reduce the risk of sinus m...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1600-0501.2012.02506.x

    authors: Chan HL,Oh TJ,Fu JH,Benavides E,Avila-Ortiz G,Wang HL

    更新日期:2013-09-01 00:00:00

  • Effect of absorbable membranes on sandwich bone augmentation.

    abstract:OBJECTIVES:This study was conducted to evaluate the effect of barrier membranes on sandwich bone augmentation (SBA) for the treatment of implant dehiscence defects. MATERIAL AND METHODS:Twenty-six implant-associated buccal dehiscence defects in 22 patients were treated according to the SBA concept - mineralized human ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/j.1600-0501.2007.01408.x

    authors: Park SH,Lee KW,Oh TJ,Misch CE,Shotwell J,Wang HL

    更新日期:2008-01-01 00:00:00

  • Two-year clinical outcomes following non-surgical mechanical therapy of peri-implantitis with adjunctive diode laser application.

    abstract:BACKGROUND:Non-surgical mechanical therapy of peri-implantitis (PI) with/without adjunctive measures yields limited clinical improvements. AIM:To evaluate the clinical outcomes following non-surgical mechanical therapy of PI with adjunctive application of a diode laser after an observation period ≥2 years. MATERIAL A...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12689

    authors: Mettraux GR,Sculean A,Bürgin WB,Salvi GE

    更新日期:2016-07-01 00:00:00

  • The influence of abutment macro-design on clinical and radiographic peri-implant tissue changes for guided, placed, and restored implants: A 1-year randomized controlled trial.

    abstract:OBJECTIVES:The aim was to evaluate the peri-implant tissue levels over a 1-year period for implants connected to either convex or concave final abutments at the time of implant placement. MATERIALS AND METHODS:In this randomized, double masked, controlled clinical study, twenty-eight patients with one missing maxillar...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.13493

    authors: Koutouzis T,Adeinat B,Ali A

    更新日期:2019-09-01 00:00:00

  • The influence of sinus membrane thickness upon membrane perforation during lateral window sinus augmentation.

    abstract:OBJECTIVES:To investigate: (1) sinus membrane thickness in patients receiving lateral window sinus augmentation via cone-beam computed tomography (CBCT) and (2) the influence of Schneiderian membrane thickness upon membrane perforation during lateral window approach. MATERIAL AND METHODS:A total of 73 subjects with 81...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12646

    authors: Lin YH,Yang YC,Wen SC,Wang HL

    更新日期:2016-05-01 00:00:00

  • Vertical augmentation of the posterior atrophic mandible by interpositional grafts in a split-mouth design: a human tomography evaluation pilot study.

    abstract:OBJECTIVE:Using computed tomography, to compare vertical and volumetric bone augmentation after interposition grafting with bovine bone mineral matrix (GEISTLICH BIO-OSS® ) or hydroxyapatite/tricalcium phosphate (STRAUMANN® BONECERAMIC) for atrophic posterior mandible reconstruction through segmental osteotomy. MATERI...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12985

    authors: Domingues EP,Ribeiro RF,Horta MCR,Manzi FR,Côsso MG,Zenóbio EG

    更新日期:2017-10-01 00:00:00

  • Simultaneous implant placement and bone regeneration around dental implants using tissue-engineered bone with fibrin glue, mesenchymal stem cells and platelet-rich plasma.

    abstract::This study was undertaken to evaluate the use of tissue-engineered bone as grafting material for alveolar augmentation with simultaneous implant placement. Twelve adult hybrid dogs were used in this study. One month after the extraction of teeth in the mandible region, bone defects on both sides of the mandible were i...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2006.01246.x

    authors: Ito K,Yamada Y,Naiki T,Ueda M

    更新日期:2006-10-01 00:00:00

  • Peri-implant bone organization surrounding zirconia-microgrooved surfaces circularly polarized light and confocal laser scanning microscopy study.

    abstract:OBJECTIVES:To study the peri-implant bone organization pattern of immediately loaded (IL) zirconia implants with microgrooved surfaces. MATERIALS AND METHODS:Forty-eight dental implants of 4 mm diameter and 10 mm length were inserted after two months postextraction healing in the edentulous mandible of six dogs. Three...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12461

    authors: Delgado-Ruiz RA,Abboud M,Romanos G,Aguilar-Salvatierra A,Gomez-Moreno G,Calvo-Guirado JL

    更新日期:2015-11-01 00:00:00

  • Direct loading of Nobel Direct and Nobel Perfect one-piece implants: a 1-year prospective clinical and radiographic study.

    abstract:OBJECTIVES:The aim of this prospective study was to evaluate the Nobel Direct and Nobel Perfect one-piece implants (OPIs) when used for immediate function. MATERIAL AND METHODS:Forty-eight patients were provided with 115 OPIs for loading with a provisional crown or a bridge within 24 h and followed for at least 12 mon...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2007.01346.x

    authors: Ostman PO,Hellman M,Albrektsson T,Sennerby L

    更新日期:2007-08-01 00:00:00

  • Positive effect of strontium-oxide layer on the osseointegration of moderately rough titanium surface in non-osteoporotic rabbits.

    abstract:OBJECTIVES:To evaluate the effect of strontium-oxide layer on new bone formation and osseointegration of sandblasted large-grit double-acid-etched (SLA) implant. MATERIAL AND METHODS:Strontium-oxide layer on the SLA surface was produced by hydrothermal treatment using a Sr-containing solution. The surface topographies...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12897

    authors: Fan YP,Chen XY,Chen Y,Yang GL,Wang HM,He FM

    更新日期:2017-08-01 00:00:00

  • Characterization of novel silane coatings on titanium implant surfaces.

    abstract:OBJECTIVES:This in vitro study describes and characterizes a developed novel method to produce coatings on Ti. Hydrophobic coatings on substrates are needed in prosthetic dentistry to promote durable adhesion between luting resin cements and coated Ti surfaces. In implant dentistry the hydrophobic coatings on a Ti impl...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2012.02504.x

    authors: Matinlinna JP,Tsoi JK,de Vries J,Busscher HJ

    更新日期:2013-06-01 00:00:00

  • Does bone mineral density influence the primary stability of dental implants? A systematic review.

    abstract:OBJECTIVE:The aim of this systematic review was to investigate the influence of bone mineral density on the primary stability of dental implants. MATERIAL AND METHODS:A search of health science databases (Cochrane Library, MEDLINE-PubMed, ISI Web of Knowledge, EMBASE, LILACS) and grey literature was performed, includi...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,评审

    doi:10.1111/j.1600-0501.2011.02228.x

    authors: Marquezan M,Osório A,Sant'Anna E,Souza MM,Maia L

    更新日期:2012-07-01 00:00:00

  • A new optical method to evaluate three-dimensional volume changes of alveolar contours: a methodological in vitro study.

    abstract:OBJECTIVES:The aim of this study was to evaluate the reproducibility and the accuracy of volumetric measurements of specimens imitating localized alveolar ridge defects using an optical three-dimensional (3D) system. MATERIAL AND METHODS:Eight pairs of specimens (five with a cuboid and three with a geometrically compl...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2007.01382.x

    authors: Windisch SI,Jung RE,Sailer I,Studer SP,Ender A,Hämmerle CH

    更新日期:2007-10-01 00:00:00

  • Immediately restored one-piece single-tooth implants with reduced diameter: one-year results of a multi-center study.

    abstract:OBJECTIVES:The aim of the present multi-center study was to evaluate the treatment outcome of immediately restored one-piece single-tooth implants with a diameter of 3 mm after 1 year. MATERIAL AND METHODS:A total of 57 one-piece implants (NobelDirect 3.0) were inserted in 47 patients (26 females, 21 males) with a mea...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,多中心研究

    doi:10.1111/j.1600-0501.2011.02174.x

    authors: Zembić A,Johannesen LH,Schou S,Malo P,Reichert T,Farella M,Hämmerle CH

    更新日期:2012-01-01 00:00:00

  • Immediate vs. conventional loading of palatal implants in humans.

    abstract:OBJECTIVES:To analyze the clinical performance and bone-to-implant contact (BIC) rate of two loading concepts on successfully healed and explanted palatal implants in humans. METHODS:From 2000 to 2006, two independent groups of patients, requiring maximum anchorage, were treated. Group 1 (n=36) was subjected to immedi...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2009.01732.x

    authors: Göllner P,Jung BA,Kunkel M,Liechti T,Wehrbein H

    更新日期:2009-08-01 00:00:00

  • The effect of titanium surface roughness on the adhesion of monocytes and their secretion of TNF-alpha and PGE2.

    abstract::Dental implant surfaces are important in determining the tissue/surface interaction. One of the first cells to adhere to the implant surface is the monocyte. This study examines the effect of surface roughness on monocyte adhesion and cytokine secretion. Monocyte adherence to titanium discs of 4 different degrees of s...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.2002.130111.x

    authors: Soskolne WA,Cohen S,Sennerby L,Wennerberg A,Shapira L

    更新日期:2002-02-01 00:00:00

  • Osteotome sinus floor elevation technique without grafting material: 3-year results of a prospective pilot study.

    abstract:OBJECTIVE:In a prospective pilot study, short< or =10 mm ITI-SLA implants were placed in the resorbed posterior maxilla by means of an osteotome sinus floor elevation (OSFE) procedure without grafting material. This paper presents 3-year data assessing bone-level changes around implants. MATERIAL AND METHODS:Twenty-fi...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2008.01696.x

    authors: Nedir R,Bischof M,Vazquez L,Nurdin N,Szmukler-Moncler S,Bernard JP

    更新日期:2009-07-01 00:00:00

  • Change in sinus membrane dimension following sinus floor elevation: a retrospective cohort study.

    abstract:OBJECTIVES:To investigate: (1) the effect of the lateral window technique for maxillary sinus augmentation on sinus membrane thickness, and (2) to identify factors associated with the mean postoperative surgical space. MATERIAL AND METHODS:This retrospective cohort study included 37 sinuses corresponding to 37 consecu...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2012.02520.x

    authors: Anduze-Acher G,Brochery B,Felizardo R,Valentini P,Katsahian S,Bouchard P

    更新日期:2013-10-01 00:00:00

  • Ceramic hydroxyapatite coating on titanium implants drives selective bone marrow stromal cell adhesion.

    abstract::The aim of this study was to determine the cell characteristics that regulate implant osseointegration. The heterogeneity of bone marrow stromal cells obtained from 11 donors was assessed by measuring the expression of a large panel of adhesion molecules. Large differences in expression of adhesion molecules were dete...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.2003.00949.x

    authors: Torensma R,ter Brugge PJ,Jansen JA,Figdor CG

    更新日期:2003-10-01 00:00:00

  • Peri-implant bleeding on probing: a cross-sectional multilevel analysis of associated factors.

    abstract:OBJECTIVES:The objective was to evaluate the association between peri-implant bleeding on probing (BoP) and probing depth. Other factors regarding patients, implants, and sites were taken into consideration. MATERIAL AND METHODS:Consecutive adult patients with ≥1 dental implant were eligible. Two calibrated operators ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13001

    authors: Merli M,Bernardelli F,Giulianelli E,Toselli I,Mariotti G,Nieri M

    更新日期:2017-11-01 00:00:00

  • Factors related to peri-implantitis - a retrospective study.

    abstract:OBJECTIVES:Retrospectively, we assessed the likelihood that peri-implantitis was associated with a history of systemic disease, periodontitis, and smoking habits. METHODS:Data on probing pocket depth (PPD), bleeding on probing (BOP), and radiographic bone levels were obtained from individuals with dental implants. Per...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12208

    authors: Renvert S,Aghazadeh A,Hallström H,Persson GR