Temperature distribution in selective laser-tissue interaction.

Abstract:

:Selective photothermal interaction using dye enhancement has proven to be effective in minimizing surrounding tissue damage and delivering energy to target tissue. During laser irradiation, the process of photon absorption and thermal energy diffusion in the target tissue and its surrounding tissue are crucial. Such information allows the selection of proper operating parameters such as dye concentrations, laser power, and exposure time for optimal therapeutic effect. Combining the Monte Carlo method for energy absorption and the finite difference method for heat diffusion, the temperature distributions in target tissue and surrounding tissue in dye enhanced laser photothermal interaction are obtained. Different tissue configurations and dye enhancement are used in the simulation, and different incident beam sizes are also used to determine optimum beam sizes for various tissue configurations. Our results show that the algorithm developed in this study could predict the thermal outcome of laser irradiation. Our simulation indicates that with appropriate absorption enhancement of the target tissue, the temperature in the target tissue and in the surrounding tissue can be effectively controlled. This method can be used for optimization of lesion treatment using laser photothermal interactions. It may also provide guidance for laser immunotherapy in cancer treatment, since the immunological responses are believed to be related to tissue temperature changes.

journal_name

J Biomed Opt

authors

Crochet JJ,Gnyawali SC,Chen Y,Lemley EC,Wang LV,Chen WR

doi

10.1117/1.2204615

subject

Has Abstract

pub_date

2006-05-01 00:00:00

pages

34031

issue

3

eissn

1083-3668

issn

1560-2281

journal_volume

11

pub_type

杂志文章
  • Perspective review on applications of optics in spinal surgery.

    abstract::Optical technologies may be applied to multiple facets of spinal surgery from diagnostics to intraoperative image guidance to therapeutics. In diagnostics, the current standard remains cross-sectional static imaging. Optical surface scanning tools may have an important role; however, significant work is required to cl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章,评审

    doi:10.1117/1.JBO.23.6.060601

    authors: Guha D,Yang VXD

    更新日期:2018-06-01 00:00:00

  • Vector extrapolation methods for accelerating iterative reconstruction methods in limited-data photoacoustic tomography.

    abstract::As limited data photoacoustic tomographic image reconstruction problem is known to be ill-posed, the iterative reconstruction methods were proven to be effective in terms of providing good quality initial pressure distribution. Often, these iterative methods require a large number of iterations to converge to a soluti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.7.071204

    authors: Awasthi N,Kalva SK,Pramanik M,Yalavarthy PK

    更新日期:2018-02-01 00:00:00

  • Effects of lipid composition on photothermal optical coherence tomography signals.

    abstract:SIGNIFICANCE:Photothermal optical coherence tomography (PT-OCT) has the promise to offer structural images coregistered with chemical composition information, which can offer a significant impact in early detection of diseases such as atherosclerosis. AIM:We take the first step in understanding the relation between PT...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.25.12.120501

    authors: Salimi M,Villiger M,Tabatabaei N

    更新日期:2020-12-01 00:00:00

  • Modulation transfer function measurement of scanning reflectance microscopes.

    abstract::Real-time medical imaging systems such as reflectance confocal microscopes and optical coherence microscopes are being tested in multiple-patient and multiple-center clinical trials. The modulation transfer function (MTF) of these systems at any given time influences the image information content and can affect the in...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.2779352

    authors: Wang Z,Glazowski CE,Zavislan JM

    更新日期:2007-09-01 00:00:00

  • In vivo super-resolution retinal imaging through virtually structured detection.

    abstract::High resolution is important for sensitive detection of subtle distortions of retinal morphology at an early stage of eye diseases. We demonstrate virtually structured detection (VSD) as a feasible method to achieve in vivo super-resolution ophthalmoscopy. A line-scanning strategy was employed to achieve a super-resol...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.12.120502

    authors: Liu C,Zhi Y,Wang B,Thapa D,Chen Y,Alam M,Lu Y,Yao X

    更新日期:2016-12-01 00:00:00

  • Optical fiber Bragg grating-instrumented silicone liner for interface pressure measurement within prosthetic sockets of lower-limb amputees.

    abstract::This paper presents a fiber Bragg grating (FBG)-instrumented prosthetic silicone liner that provides cushioning for the residual limb and can successfully measure interface pressures inside prosthetic sockets of lower-limb amputees in a simple and practical means of sensing. The liner is made of two silicone layers be...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.8.087001

    authors: Al-Fakih E,Arifin N,Pirouzi G,Mahamd Adikan FR,Shasmin HN,Abu Osman NA

    更新日期:2017-08-01 00:00:00

  • Angiography with a multifunctional line scanning ophthalmoscope.

    abstract::A multifunctional line scanning ophthalmoscope (mLSO) was designed, constructed, and tested on human subjects. The mLSO could sequentially acquire wide-field, confocal, near-infrared reflectance, fluorescein angiography (FA), and indocyanine green angiography (ICGA) retinal images. The system also included a retinal t...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.2.026008

    authors: Hammer DX,Ferguson RD,Patel AH,Vazquez V,Husain D

    更新日期:2012-02-01 00:00:00

  • Theory and practical recommendations for autocorrelation-based image correlation spectroscopy.

    abstract::Image correlation spectroscopy (ICS) is a powerful technique for detecting arrangement of fluorophores in images. This tutorial gives background into the mathematical underpinnings of ICS, specifically image autocorrelation. The effects of various artifacts and image processing steps, including background subtraction,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.080801

    authors: Robertson C,George SC

    更新日期:2012-08-01 00:00:00

  • Surface plasmon-based infrared spectroscopy for cell biosensing.

    abstract::Cell morphology is often used as a valuable indicator of the physical condition and general status of living cells. We demonstrate a noninvasive method for morphological characterization of adherent cells. We measure infrared reflectivity spectrum at oblique angle from living cells cultured on thin Au film, and utiliz...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.17.8.081409

    authors: Yashunsky V,Lirtsman V,Zilbershtein A,Bein A,Schwartz B,Aroeti B,Golosovsky M,Davidov D

    更新日期:2012-08-01 00:00:00

  • In vivo spectral imaging of different cell types in the small intestine by two-photon excited autofluorescence.

    abstract::Spectrally resolved two-photon excited autofluorescence imaging is used to distinguish different cell types and functional areas during dynamic processes in the living gut. Excitation and emission spectra of mucosal tissue and tissue components are correlated to spectra of endogenous chromophores. We show that selecti...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3655587

    authors: Orzekowsky-Schroeder R,Klinger A,Martensen B,Blessenohl M,Gebert A,Vogel A,Hüttmann G

    更新日期:2011-11-01 00:00:00

  • Pediatric Vision Screener 2: pilot study in adults.

    abstract::Amblyopia is a form of visual impairment caused by ocular misalignment (strabismus) or defocus in an otherwise healthy eye. If detected early, the condition can be fully treated, yet over half of all children with amblyopia under age 5 escape detection. We developed a Pediatric Vision Screener (PVS) to detect amblyopi...

    journal_title:Journal of biomedical optics

    pub_type: 临床试验,杂志文章

    doi:10.1117/1.1805561

    authors: Nassif DS,Piskun NV,Gramatikov BI,Guyton DL,Hunter DG

    更新日期:2004-11-01 00:00:00

  • Band analysis of hydrated human skin stratum corneum attenuated total reflectance fourier transform infrared spectra in vivo.

    abstract::Water content is an important factor for skin condition. The determination of the hydration state of the skin is necessary to obtain basic knowledge about the penetration and loss of water in the skin stratum corneum. Attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy is used to measure hy...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429890

    authors: Lucassen GW,van Veen GN,Jansen JA

    更新日期:1998-07-01 00:00:00

  • Resolution in the ApoTome and the confocal laser scanning microscope: comparison.

    abstract::The essential feature of the confocal laser scanning microscope (cLSM) is the generation of optical sections by the removal of out-of-focus light. About ten years ago, structured illumination microscopy (SIM) was introduced as an alternative method for obtaining optical sections from biological specimens. Here we comp...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3083439

    authors: Weigel A,Schild D,Zeug A

    更新日期:2009-01-01 00:00:00

  • Integration of a Raman spectroscopy system to a robotic-assisted surgical system for real-time tissue characterization during radical prostatectomy procedures.

    abstract::Surgical excision of the whole prostate through a radical prostatectomy procedure is part of the standard of care for prostate cancer. Positive surgical margins (cancer cells having spread into surrounding nonresected tissue) occur in as many as 1 in 5 cases and strongly correlate with disease recurrence and the requi...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.24.2.025001

    authors: Pinto M,Zorn KC,Tremblay JP,Desroches J,Dallaire F,Aubertin K,Marple E,Kent C,Leblond F,Trudel D,Lesage F

    更新日期:2019-02-01 00:00:00

  • Design of synchrotron light source and its beamline dedicated to dual-energy x-ray computed tomography.

    abstract::A synchrotron light source dedicated to medical applications has been designed at National Institute of Radiological Sciences. The storage ring, with circumference of 80 m, is designed for acceleration of 2.3 GeV and a stored current of 420 mA. It is equipped with two multipole wigglers to produce sufficient photon fl...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1383062

    authors: Torikoshi M,Tsunoo T,Endo M,Noda K,Kumada M,Yamada S,Soga F,Hyodo K

    更新日期:2001-07-01 00:00:00

  • Contrasting properties of gold nanoshells and titanium dioxide nanoparticles for optical coherence tomography imaging of skin: Monte Carlo simulations and in vivo study.

    abstract::The effect of silica/gold nanoshells and titanium dioxide nanoparticles on the optical properties of skin is studied. By implementing in vivo measurements and Monte Carlo simulations, we analyze the efficiency of using these nanoparticles as contrasting agents for optical coherence tomography (OCT) imaging of skin. In...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3122373

    authors: Kirillin M,Shirmanova M,Sirotkina M,Bugrova M,Khlebtsov B,Zagaynova E

    更新日期:2009-03-01 00:00:00

  • Laser trap ionization for identification of human erythrocytes with variable hemoglobin quantitation.

    abstract::An approach to an established technique that is potentially applicable for a more comprehensive understanding of the electrical properties of red blood cells (RBCs) is presented. Using a high-intensity gradient laser trap, RBCs can be singly trapped and consequentially ionized. The subsequent dynamics of the ionized c...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.5.055005

    authors: Kelley M,Cooper J,Devito D,Mushi R,Aguinaga MDP,Erenso DB

    更新日期:2018-05-01 00:00:00

  • Closure of skin incisions by laser-welding with a combination of two near-infrared diode lasers: preliminary study for determination of optimal parameters.

    abstract::Laser welding has the potential to become an effective method for wound closure and healing without sutures. Closure of skin incisions by laser welding with a combination of two near-infrared lasers (980 and 1064 nm), was performed for the first time in this study. One centimeter long, full-thickness incisions were ma...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3552648

    authors: Hu L,Lu Z,Wang B,Cao J,Ma X,Tian Z,Gao Z,Qin L,Wu X,Liu Y,Wang L

    更新日期:2011-03-01 00:00:00

  • Volume holographic imaging endoscopic design and construction techniques.

    abstract::A reflectance volume holographic imaging (VHI) endoscope has been designed for simultaneous in vivo imaging of surface and subsurface tissue structures. Prior utilization of VHI systems has been limited to ex vivo tissue imaging. The VHI system presented in this work is designed for laparoscopic use. It consists of a ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.22.5.056010

    authors: Howlett ID,Han W,Gordon M,Rice P,Barton JK,Kostuk RK

    更新日期:2017-05-01 00:00:00

  • Application of functional data analysis in classification and clustering of functional near-infrared spectroscopy signal in response to noxious stimuli.

    abstract::We introduce the application of functional data analysis (fDA) on functional near-infrared spectroscopy (fNIRS) signals for the development of an accurate and clinically practical assessment method of pain perception. We used the cold pressor test to induce different levels of pain in healthy subjects while the fNIRS ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.10.101411

    authors: Pourshoghi A,Zakeri I,Pourrezaei K

    更新日期:2016-10-01 00:00:00

  • Photonic approach to the selective inactivation of viruses with a near-infrared subpicosecond fiber laser.

    abstract::We report a photonic approach for selective inactivation of viruses with a near-infrared subpicosecond laser. We demonstrate that this method can selectively inactivate viral particles ranging from nonpathogenic viruses such as the M13 bacteriophage and the tobacco mosaic virus to pathogenic viruses such as the human ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3275477

    authors: Tsen KT,Tsen SW,Fu Q,Lindsay SM,Kibler K,Jacobs B,Wu TC,Karanam B,Jagu S,Roden RB,Hung CF,Sankey OF,Ramakrishna B,Kiang JG

    更新日期:2009-11-01 00:00:00

  • Navigation of a robot-integrated fluorescence laparoscope in preoperative SPECT/CT and intraoperative freehand SPECT imaging data: a phantom study.

    abstract::Robot-assisted laparoscopic surgery is becoming an established technique for prostatectomy and is increasingly being explored for other types of cancer. Linking intraoperative imaging techniques, such as fluorescence guidance, with the three-dimensional insights provided by preoperative imaging remains a challenge. Na...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.21.8.086008

    authors: van Oosterom MN,Engelen MA,van den Berg NS,KleinJan GH,van der Poel HG,Wendler T,van de Velde CJ,Navab N,van Leeuwen FW

    更新日期:2016-08-01 00:00:00

  • Image reconstruction in photoacoustic tomography with variable speed of sound using a higher-order geometrical acoustics approximation.

    abstract::Previous research correcting for variable speed of sound in photoacoustic tomography (PAT) based on a generalized radon transform (GRT) model assumes first-order geometrical acoustics (GA) approximation. In the GRT model, the pressure is related to the optical absorption, in an acoustically inhomogeneous medium, throu...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3333550

    authors: Modgil D,Anastasio MA,La Rivière PJ

    更新日期:2010-03-01 00:00:00

  • Photon pathlength determination based on spatially resolved diffuse reflectance.

    abstract::A method for the prediction of the average photon pathlength in turbid media has been developed. The method is based on spatially resolved diffuse reflectance with discrete source detector distances up to 2 mm. Light reflectance was simulated using a Monte Carlo technique with a one-layer model utilizing a wide range ...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.1482378

    authors: Nilsson H,Larsson M,Nilsson GE,Strömberg T

    更新日期:2002-07-01 00:00:00

  • Experimental measurement of time-dependent photon scatter for diffuse optical tomography.

    abstract::Time-resolved measurement of early arriving photons through diffusive media has been shown to effectively reduce the high degree of light scatter in biological tissue. However, the experimentally achievable reduction in photon scatter and the impact of time-gated detection on instrument noise performance is not well u...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.3523371

    authors: Valim N,Brock J,Niedre M

    更新日期:2010-11-01 00:00:00

  • Noninvasive measurement of glucose concentration on human fingertip by optical coherence tomography.

    abstract::A method is proposed for determining the glucose concentration on the human fingertip by extracting two optical parameters, namely the optical rotation angle and the depolarization index, using a Mueller optical coherence tomography technique and a genetic algorithm. The feasibility of the proposed method is demonstra...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.23.4.047001

    authors: Chen TL,Lo YL,Liao CC,Phan QH

    更新日期:2018-04-01 00:00:00

  • Photon migration through fetal head in utero using continuous wave, near-infrared spectroscopy: development and evaluation of experimental and numerical models.

    abstract::In this work experimental tissue phantoms and numerical models were developed to estimate photon migration through the fetal head in utero. The tissue phantoms incorporate a fetal head within an amniotic fluid sac surrounded by a maternal tissue layer. A continuous wave, dual-wavelength (lambda = 760 and 850 nm) spect...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.429983

    authors: Vishnoi G,Hielscher AH,Ramanujam N,Chance B

    更新日期:2000-04-01 00:00:00

  • Performance assessment of time-domain optical brain imagers, part 2: nEUROPt protocol.

    abstract::The nEUROPt protocol is one of two new protocols developed within the European project nEUROPt to characterize the performances of time-domain systems for optical imaging of the brain. It was applied in joint measurement campaigns to compare the various instruments and to assess the impact of technical improvements. T...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.19.8.086012

    authors: Wabnitz H,Jelzow A,Mazurenka M,Steinkellner O,Macdonald R,Milej D,Żołek N,Kacprzak M,Sawosz P,Maniewski R,Liebert A,Magazov S,Hebden J,Martelli F,Di Ninni P,Zaccanti G,Torricelli A,Contini D,Re R,Zucchelli L,Spine

    更新日期:2014-08-01 00:00:00

  • Study of the influence of over-the-counter vitamin supplement intake on urine fluorescence to optimize cancer detection by fluorescence cystoscopy.

    abstract::Fluorescence cystoscopy (FC) efficiently enhances the detection and improves the therapeutic management of early bladder cancer. During an FC, about 150 ml of water is needed to inflate the bladder. The water is quickly diluted by urine which can be fluorescent. If this bladder washout fluid (BWF) becomes fluorescent,...

    journal_title:Journal of biomedical optics

    pub_type: 杂志文章

    doi:10.1117/1.JBO.20.6.066011

    authors: Zellweger M,Martoccia C,Mengin M,Iselin C,van den Bergh H,Wagnières G

    更新日期:2015-06-01 00:00:00

  • Ultrasonic standing wave preparation of a liquid cell for glucose measurements in urine by midinfrared spectroscopy and potential application to smart toilets.

    abstract::Smart toilets could be used to monitor different components of urine in daily life for early detection of lifestyle-related diseases and prompt provision of treatment. For analysis of biological samples such as urine by midinfrared spectroscopy, thin-film samples like liquid cells are needed because of the strong abso...

    journal_title:Journal of biomedical optics

    pub_type: 信件

    doi:10.1117/1.JBO.23.5.050503

    authors: Yamamoto N,Kawashima N,Kitazaki T,Mori K,Kang H,Nishiyama A,Wada K,Ishimaru I

    更新日期:2018-05-01 00:00:00