Implant-tooth-supported fixed partial prostheses: correlations between in vivo occlusal bite forces and marginal bone reactions.

Abstract:

PURPOSE:To evaluate maximal occlusal bite forces (MOF) and marginal bone level (MBL) changes in patients with implant-tooth-supported fixed partial prostheses (FPP). MATERIAL AND METHODS:Twenty nine partially edentulous patients consecutively who received 34 three-occlusal unit FPP with terminal implant and tooth support were subjected to quantification of MOFs using a sub-miniature load cell connected to a data acquisition system and measurement of the MBL changes around implants in digitalized periapical radiographs obtained at prostheses delivery and 24-month follow-up. RESULTS:MOFs for implant support (mean: 353.61 N) significantly differed from tooth support (mean: 275.48 N) (P < 0.05), while gender did not influence MOFs (P > 0.05). MBL changes at mesial and distal sites of the implants at 24 months of functional loading were 0.28 and 0.097 mm respectively. CONCLUSION:Although MOFs under functional loading might indicate an increase in load participation for supporting implant, the rigid connection between implant and natural tooth via three-occlusal unit FPP does not jeopardize the time-dependent MBL stability of the implant under functional loads.

journal_name

Clin Oral Implants Res

authors

Akça K,Uysal S,Cehreli MC

doi

10.1111/j.1600-0501.2005.01169.x

subject

Has Abstract

pub_date

2006-06-01 00:00:00

pages

331-6

issue

3

eissn

0905-7161

issn

1600-0501

pii

CLR1169

journal_volume

17

pub_type

杂志文章
  • Early loading of mandibular full-arch bridges screw retained after 1 week to four to five Monotype® implants: 3-year results from a prospective multicentre study.

    abstract:OBJECTIVES:This prospective multicentre study provides clinical experience up to 3 years to support a simplified treatment for mandibular edentulism within 1 week by using one-stage implant surgery and a screw-retained full-arch bridge. METHODS:Two hundred and fifty ITI Monotype® implants were installed in 62 patients...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2008.01540.x-i2

    authors: Arvidson K,Esselin O,Felle-Persson E,Jonsson G,Smedberg JI,Soderstrom U

    更新日期:2008-07-01 00:00:00

  • Oral health-related quality of life and esthetic outcome in single anterior maxillary implants.

    abstract:OBJECTIVES:The aim of this study is twofold: to assess the esthetic outcome of single dental implant restorations in the anterior maxillary area after up to 3 years of function, and to evaluate the relationship between the esthetic outcome and oral health-related quality of life. MATERIALS AND METHODS:Twenty patients ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12922

    authors: Angkaew C,Serichetaphongse P,Krisdapong S,Dart MM,Pimkhaokham A

    更新日期:2017-09-01 00:00:00

  • Biomechanical aspects of initial intraosseous stability and implant design: a quantitative micro-morphometric analysis.

    abstract:PURPOSE:The objective of this biomechanical study was to explore the effect of bone micro-morphology on initial intraosseous stability of implants with different designs. MATERIAL AND METHODS:Straumann and Astra Tech dental implants were placed into anterior and posterior regions of completely edentulous maxilla and m...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2006.01265.x

    authors: Akça K,Chang TL,Tekdemir I,Fanuscu MI

    更新日期:2006-08-01 00:00:00

  • The influence of the masticatory mucosa on the peri-implant soft tissue condition.

    abstract::The aim of this study was to evaluate the soft tissue conditions at osseo-integrated oral implants in relation to the width of masticatory mucosa. Thirty-nine patients who had received a full-arch fixed bridge reconstruction > or = 10 years ago or a partial reconstruction > or = 5 years ago on a total of 171 implants ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1994.050101.x

    authors: Wennström JL,Bengazi F,Lekholm U

    更新日期:1994-03-01 00:00:00

  • Clinical outcome of 103 consecutive zygomatic implants: a 6-48 months follow-up study.

    abstract::The purpose of this study was to evaluate retrospectively, after a period of 6-48 months follow-up of prosthetic loading, the survival rate of 103 zygomatic implants inserted in 55 totally edentulous severely resorbed upper jaws. Fifty-five consecutive patients, 41 females and 14 males, with severe maxillary bone reso...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1046/j.1600-0501.2003.00985.x

    authors: Malevez C,Abarca M,Durdu F,Daelemans P

    更新日期:2004-02-01 00:00:00

  • The immediate rehabilitation by means of a ready-made final fixed prosthesis in the edentulous mandible: a 1-year follow-up study on 50 consecutive patients.

    abstract::Although a two-stage procedure with symphyseal oral implants can lead to a long-term (15 years) 99% cumulative survival rate, a one-stage approach with immediate loading via prefabricated elements seems to offer a short-term acceptable outcome with significantly lower costs. A series of 50 consecutive patients, not el...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2004.01069.x

    authors: van Steenberghe D,Molly L,Jacobs R,Vandekerckhove B,Quirynen M,Naert I

    更新日期:2004-06-01 00:00:00

  • The effect of hyperbaric oxygen treatment on bone tissue reactions to c.p. titanium implants placed in free autogenous bone grafts. A histomorphometric study in the rabbit mandible.

    abstract::This study aimed to investigate the effect of hyperbaric oxygen (HBO) therapy on the tissue reactions to commercially pure (c.p.) titanium implants placed in free autogenous bone graft by a 1-stage procedure. Eighty c.p. titanium implants were placed in the bone grafted from iliac crest to bilateral mandible of 40 Jap...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1996.090604.x

    authors: Sawai T,Niimi A,Johansson CB,Sennerby L,Ozeki K,Takahashi H,Albrektsson T,Ueda M

    更新日期:1998-12-01 00:00:00

  • Computer-guided implant therapy and soft- and hard-tissue aspects. The Third EAO Consensus Conference 2012.

    abstract:INTRODUCTION:The objectives of this working group were to update the existing knowledge base in computer-guided implant treatment (accuracy and clinical advantages), to search for scientific evidence on the need for keratinized tissue around implants, and to review recent literature in the search for new insights into ...

    journal_title:Clinical oral implants research

    pub_type: 共识发展会议,杂志文章,评审

    doi:10.1111/j.1600-0501.2012.02553.x

    authors: Sicilia A,Botticelli D,Working Group 3.

    更新日期:2012-10-01 00:00:00

  • Early colonization of non-submerged dental implants in patients with a history of advanced aggressive periodontitis.

    abstract::The aim of the study was to evaluate the early colonization of non-submerged implants over a 6-month period in partially edentulous patients treated for advanced aggressive periodontal disease. In 22 patients treated for advanced aggressive periodontitis and in a supportive maintenance program for a period between 12 ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2005.01175.x

    authors: De Boever AL,De Boever JA

    更新日期:2006-02-01 00:00:00

  • A 10-year prospective clinical and radiographic study of one-stage dental implants.

    abstract:OBJECTIVE:The purpose of this prospective study was to evaluate one-stage dental implants clinically and radiographically after 10 years in function. MATERIAL AND METHODS:Twenty-five patients with a total of 68 implants [46 hollow screws (HS) and 22 hollow cylinders (HC)] who previously participated in 5-year prospect...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2007.01479.x

    authors: Kim DM,Badovinac RL,Lorenz RL,Fiorellini JP,Weber HP

    更新日期:2008-03-01 00:00:00

  • Fracture resistance of inter-joined zirconia abutment of dental implant system with injection molding technique.

    abstract:OBJECTIVES:Zirconia powder in nanometers can be fabricated into inter-joined abutment of dental implant system with the injection shaping technique. This study was to detect the resistance of inter-joined zirconia abutment with different angle loading for clinical applications. MATERIALS AND METHODS:The inter-joined a...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2012.02539.x

    authors: Yang J,Wang K,Liu G,Wang D

    更新日期:2013-11-01 00:00:00

  • Implant surface roughness alterations induced by different prophylactic procedures: an in vitro study.

    abstract:AIM:To evaluate surface roughness alterations at the smooth neck of dental implants after the use of eight different prophylactic procedures. MATERIALS AND METHODS:50 tissue level implants (Institut Straumann AG, Basel, Switzerland) were used for the present investigation. The smooth collar of each implant was divided...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12849

    authors: Cafiero C,Aglietta M,Iorio-Siciliano V,Salvi GE,Blasi A,Matarasso S

    更新日期:2017-07-01 00:00:00

  • Two-year clinical outcomes following non-surgical mechanical therapy of peri-implantitis with adjunctive diode laser application.

    abstract:BACKGROUND:Non-surgical mechanical therapy of peri-implantitis (PI) with/without adjunctive measures yields limited clinical improvements. AIM:To evaluate the clinical outcomes following non-surgical mechanical therapy of PI with adjunctive application of a diode laser after an observation period ≥2 years. MATERIAL A...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12689

    authors: Mettraux GR,Sculean A,Bürgin WB,Salvi GE

    更新日期:2016-07-01 00:00:00

  • Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog.

    abstract:OBJECTIVE:The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. MATERIAL AND METHODS:Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2009.01832.x

    authors: Koch FP,Weng D,Krämer S,Biesterfeld S,Jahn-Eimermacher A,Wagner W

    更新日期:2010-03-01 00:00:00

  • CBCT device dependency on the transfer accuracy from computer-aided implantology procedures.

    abstract:OBJECTIVES:To evaluate the potential influence of different cone-beam computed tomography (CBCT) devices on the transfer accuracy of an open-source system for computer-aided implantology (CAI). MATERIAL AND METHODS:A total of 108 implants in 18 partially edentulous patient-equivalent models were planned and fully guid...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2011.02272.x

    authors: Dreiseidler T,Tandon D,Kreppel M,Neugebauer J,Mischkowski RA,Zinser MJ,Zöller JE

    更新日期:2012-09-01 00:00:00

  • Influence of barrier occlusiveness on guided bone augmentation. An experimental study in the rat.

    abstract::The present study was designed to test perforated and non-perforated barriers for their ability to promote augmentation of bone tissue. More specifically, 1 totally occlusive barrier and 6 barriers with perforation sizes of about 10, 25, 50, 75, 100, and 300 microns and 1 group with no barriers placed (open test chamb...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1998.090406.x

    authors: Lundgren A,Lundgren D,Taylor A

    更新日期:1998-08-01 00:00:00

  • Is the use of digital technologies for the fabrication of implant-supported reconstructions more efficient and/or more effective than conventional techniques: A systematic review.

    abstract:OBJECTIVE:To identify clinical studies evaluating efficiency and/or effectiveness of digital technologies as compared to conventional manufacturing procedures for the fabrication of implant-supported reconstructions. MATERIALS AND METHODS:A systematic search from 1990 through July 2017 was performed using the online d...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13300

    authors: Mühlemann S,Kraus RD,Hämmerle CHF,Thoma DS

    更新日期:2018-10-01 00:00:00

  • Immediate functional loading of Brånemark single tooth implants. An 18 months' clinical pilot follow-up study.

    abstract::A clinical and radiographical study was performed to evaluate the treatment outcome of single tooth replacements with artificial crowns retained to implants installed according to a 1-stage surgical procedure and immediate loading (Experimental Group = EG) in comparison to the original 2-stage concept (Control Group =...

    journal_title:Clinical oral implants research

    pub_type: 临床试验,杂志文章

    doi:10.1034/j.1600-0501.2000.011001026.x

    authors: Ericsson I,Nilson H,Lindh T,Nilner K,Randow K

    更新日期:2000-02-01 00:00:00

  • Fixture design and overload influence marginal bone loss and fixture success in the Brånemark system.

    abstract::It has been documented that the long-term clinical outcome of the Brånemark system is very favourable. However, failures do occur before and after loading. This study examined the differences in marginal bone loss between standard and self-tapping fixtures and attempted to explain excessive marginal bone loss or loss ...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1992.030302.x

    authors: Quirynen M,Naert I,van Steenberghe D

    更新日期:1992-09-01 00:00:00

  • Histological and histomorphometrical evaluation of tissue reactions adjacent to endosteal implants in monkeys.

    abstract::A qualitative and quantitative histological study of the initial healing response adjacent to 24 submerged and non-submerged implants placed in the lower jaws of 6 monkeys is presented. The histomorphometric analysis showed no significant differences in mineralized bone-implant contact length between submerged and non...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1034/j.1600-0501.1991.020104.x

    authors: Gotfredsen K,Rostrup E,Hjörting-Hansen E,Stoltze K,Budtz-Jörgensen E

    更新日期:1991-01-01 00:00:00

  • Esthetic, clinical and patient-centered outcomes of immediately placed implants (Type 1) and early placed implants (Type 2): preliminary 3-month results of an ongoing randomized controlled clinical trial.

    abstract:AIM:The objective of the study was to compare (i) esthetic, (ii) clinical and (iii) patient-centered outcomes following immediate (Type 1) and early implant placement (Type 2). MATERIAL AND METHODS:Thirty-eight subjects needing a single extraction (premolar to premolar) were randomly allocated to Type 1 or Type 2 impl...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.12577

    authors: Huynh-Ba G,Meister DJ,Hoders AB,Mealey BL,Mills MP,Oates TW,Cochran DL,Prihoda TJ,McMahan CA

    更新日期:2016-02-01 00:00:00

  • Radiologic comparative analysis between saline and platelet-rich fibrin filling after hydraulic transcrestal sinus lifting without adjunctive bone graft: A randomized controlled trial.

    abstract:OBJECTIVES:To evaluate implant survival rate, any complications, and changes in residual alveolar bone height (RABH) using saline or platelet-rich fibrin (PRF) filling after hydraulic transcrestal sinus lifting. METHODS:Dental implants were placed after hydraulic transcrestal sinus lifting and the filling of saline (2...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.13655

    authors: Cho YS,Hwang KG,Jun SH,Tallarico M,Kwon AM,Park CJ

    更新日期:2020-11-01 00:00:00

  • Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits.

    abstract::In the present study, the influence of initial instability on the healing of titanium implants was studied in 9 lop-eared rabbits. Titanium implants (Brånemark System) were inserted in the tibiae, a location with cortical bone only, in such a way that they were either stable (control), rotation-mobile, or totally mobi...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:

    authors: Ivanoff CJ,Sennerby L,Lekholm U

    更新日期:1996-06-01 00:00:00

  • Retraction.

    abstract::Ramírez-Fernández MP, Calvo-Guirado JL, Arcesio Delgado-Ruiz R, Maté-Sánchez del Val JE, Gómez-Moreno G, Guardia J. Experimental model of bone response to xenografts of bovine origin (Endobon® ): a radiological and histomorphometric study. Clin Oral Impl Res. 2011;22: 727-734. The above article, published online on 29...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,撤回出版物

    doi:10.1111/clr.13085

    authors:

    更新日期:2018-06-01 00:00:00

  • A five-year life-table analysis on wide neck ITI implants with prosthetic evaluation and radiographic analysis: results from a private practice.

    abstract::This paper reports a 5-year life-table analysis on wide neck (WN) ITI implants placed in a private practice. In 212 patients, 263 implants were placed in the posterior region; 97% rehabilitated the molar area. Implants in the mandible and in the maxilla were 61.2% and 38.8%, respectively; the mean implant length was 9...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/j.1600-0501.2006.01271.x

    authors: Bischof M,Nedir R,Abi Najm S,Szmukler-Moncler S,Samson J

    更新日期:2006-10-01 00:00:00

  • The effect of implant macro-thread design on implant stability in the early post-operative period: a randomized, controlled pilot study.

    abstract:INTRODUCTION:Available literature suggests there is a transient drop in implant stability from approximately week 0 to week 3-4 as a result of peri-implant bone remodeling as it transitions from a primary, mechanical stability to a secondary, biological stability. Research investigating the influence of macro-thread de...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.12945

    authors: McCullough JJ,Klokkevold PR

    更新日期:2017-10-01 00:00:00

  • An in vitro evaluation of fracture load of implant-supported zirconia-based prostheses fabricated with different veneer materials.

    abstract:OBJECTIVES:The purpose of this in vitro study was to evaluate fracture loads of implant-supported zirconia-based prostheses fabricated with different veneer materials (resin-based material and lithium disilicate ceramics). MATERIAL AND METHODS:Forty-four zirconia-based molar prostheses were fabricated on dental implan...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.13135

    authors: Takata H,Komine F,Honda J,Blatz MB,Matsumura H

    更新日期:2018-04-01 00:00:00

  • Rotating titanium brush for plaque removal from rough titanium surfaces--an in vitro study.

    abstract:OBJECTIVES:The purpose of this study was the evaluation of the effectiveness of plaque removing of a new rotating brush made of titanium in comparison with the cleaning procedure with steel curettes. MATERIALS AND METHODS:Plaque was collected by six volunteers for 48 h. A total of 60 samples were randomly designated t...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12147

    authors: John G,Becker J,Schwarz F

    更新日期:2014-07-01 00:00:00

  • Prospective randomized controlled clinical study comparing two types of two-piece dental implants supporting fixed reconstructions - results at 1 year of loading.

    abstract:OBJECTIVES:To analyze clinical, esthetic, radiographic, and prosthetic outcomes of implants and implant-supported reconstructions using two types of dental implants with non-matching implant abutment junctions. MATERIALS AND METHODS:A total of 64 patients in need of dental implant therapy with fixed reconstructions we...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章,随机对照试验

    doi:10.1111/clr.12721

    authors: Ebler S,Ioannidis A,Jung RE,Hämmerle CH,Thoma DS

    更新日期:2016-09-01 00:00:00

  • Comparative maxillary bone-defect healing by calcium-sulphate or deproteinized bovine bone particles and extra cellular matrix membranes in a guided bone regeneration setting: an experimental study in rabbits.

    abstract:OBJECTIVES:The aim of this study was to histologically compare the dynamics of bone healing response between calcium sulphate (CaS) and deproteinized bovine bone mineral (DBBM) particles in guided bone regeneration utilizing an extracellular matrix membrane (ECM) as barrier. MATERIALS AND METHODS:Eighteen rabbits were...

    journal_title:Clinical oral implants research

    pub_type: 杂志文章

    doi:10.1111/clr.12425

    authors: Turri A,Dahlin C

    更新日期:2015-05-01 00:00:00